Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Study on avalanche photodiode influence on heterodyne laser interferometer linearity

In the paper we analyze factors reducing the possible accuracy of the heterodyne laser interferometers. The analysis is performed for the avalanche-photodiode input stages but is in main points valid also for stages with other type of photodetectors. Instrumental error originating from optical, electronic and digital signal processing factors is taken into consideration. We stress factors which are critical and those which can be neglected at certain accuracy requirements. In the work we prove that it is possible to reduce errors of the laser instrument below 1 nm point for multiaxial APD based interferometers by precise control of incident optical power and the temperature of the photodiode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semantic embedding for quantum algorithms

The study of classical algorithms is supported by an immense understructure, founded in logic, type, and category theory, that allows an algorithmist to reason about the sequential manipulation of data irrespective of a computation’s realizing dynamics. As quantum computing matures, a similar need has developed for an assurance of the correctness of high-level quantum algorithmic reasoning. Parallel to this need, many quantum algorithms have been unified and improved using quantum signal processing (QSP) and quantum singular value transformation (QSVT), which characterize the ability, by alternating circuit ansätze, to transform the singular values of sub-blocks of unitary matrices by polynomial functions. However, while the algebraic manipulation of polynomials is simple (e.g., compositions and products), the QSP/QSVT circuits realizing analogous manipulations of their embedded polynomials are non-obvious. This work constructs and characterizes the runtime and expressivity of QSP/QSVT protocols where circuit manipulation maps naturally to the algebraic manipulation of functional transforms (termed semantic embedding). In this way, QSP/QSVT can be treated and combined modularly, purely in terms of the functional transforms they embed, with key guarantees on the computability and modularity of the realizing circuits. We also identify existing quantum algorithms whose use of semantic embedding is implicit, spanning from distributed search to proofs of soundness in quantum cryptography. The methods used, based in category theory, establish a theory of semantically embeddable quantum algorithms, and provide a new role for QSP/QSVT in reducing sophisticated algorithmic problems to simpler algebraic ones.

Physics↗

Cryogenic hybrid magnonic circuits based on spalled YIG thin films

Yttrium iron garnet (YIG) magnonics has garnered significant research interest because of the unique properties of magnons (quasiparticles of collective spin excitation) for signal processing. In particular, hybrid systems based on YIG magnonics show great promise for quantum information science due to their broad frequency tunability and strong compatibility with other platforms. However, their broad applications have been severely constrained by substantial microwave loss in the gadolinium gallium garnet (GGG) substrate at cryogenic temperatures. In this study, we demonstrate that YIG thin films can be spalled from YIG/GGG samples. Our approach is validated by measuring hybrid devices comprising superconducting resonators and spalled YIG films, which exhibit anti-crossing features that indicate strong coupling between magnons and microwave photons. Such new capability of separating YIG thin films from GGG substrates via spalling and the integrated superconductor-YIG devices represent a significant advancement for integrated magnonic devices, paving the way for advanced magnon-based coherent information processing.

36 MATERIALS SCIENCE↗

Evidence for long-term potentiation in phospholipid membranes

Biological supramolecular assemblies, such as phospholipid bilayer membranes, have been used to demonstrate signal processing via short-term synaptic plasticity (STP) in the form of paired pulse facilitation and depression, emulating the brain’s efficiency and flexible cognitive capabilities. However, STP memory in lipid bilayers is volatile and cannot be stored or accessed over relevant periods of time, a key requirement for learning. Using droplet interface bilayers (DIBs) composed of lipids, water and hexadecane, and an electrical stimulation training protocol featuring repetitive sinusoidal voltage cycling, we show that DIBs displaying memcapacitive properties can also exhibit persistent synaptic plasticity in the form of long-term potentiation (LTP) associated with capacitive energy storage in the phospholipid bilayer. The time scales for the physical changes associated with the LTP range between minutes and hours, and are substantially longer than previous STP studies, where stored energy dissipated after only a few seconds. STP behavior is the result of reversible changes in bilayer area and thickness. On the other hand, LTP is the result of additional molecular and structural changes to the zwitterionic lipid headgroups and the dielectric properties of the lipid bilayer that result from the buildup of an increasingly asymmetric charge distribution at the bilayer interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Sparse adaptive basis set methods for solution of the time dependent Schrodinger equation

Scalable numerical solutions to the time dependent Schrodinger equation remain an outstanding goal in theoretical chemistry. Here we present a method which utilises recent breakthroughs in signal processing to consistently adapt a dictionary of basis functions to the dynamics of the system. Further, we show that for two low-dimensional model problems the size of the basis set does not grow quickly with time and appears only weakly dependent on dimensionality. The generality of this finding remains to be seen. The method primarily uses energies and gradients of the potential, opening the possibility for its use in on-the-fly ab initio quantum wavepacket dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

AMiBA WIDEBAND ANALOG CORRELATOR

A wideband analog correlator has been constructed for the Yuan-Tseh Lee Array for Microwave Background Anisotropy. Lag correlators using analog multipliers provide large bandwidth and moderate frequency resolution. Broadband intermediate frequency distribution, back-end signal processing, and control are described. Operating conditions for optimum sensitivity and linearity are discussed. From observations, a large effective bandwidth of around 10 GHz has been shown to provide sufficient sensitivity for detecting cosmic microwave background variations.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanometer-thick ultraflat cantilever resonators

Nanomechanical devices made from ultrathin materials are transforming diverse fields, including sensing, signal processing, and quantum technologies. However, as these materials become thinner, their low bending rigidity poses significant fabrication challenges, and achieving nanometer-thick flat cantilevers with consistent and predictable mechanical responses has remained elusive despite decades of research. Here we present nanometer-thick, ultraflat cantilever resonators fabricated using atomic layer deposition. By effectively mitigating the effects of uncontrollable built-in strain and geometric disorder, the ultraflat nanocantilevers exhibit resonance frequencies closely aligned with thin-plate theory predictions and display low sample-to-sample variability. These cantilevers maintain mechanical stability in both vacuum and air environments, even at large length-to-thickness ratios of up to 3000. The ultraflat nanocantilevers are approaching the thickness limit, beyond which thermal fluctuations at room temperature can spontaneously induce random ripples in otherwise flat films.

nanofabrication↗

Frequency-domain computing using nonlinear acoustic-wave device on lithium niobate

Abstract Multiply-accumulation are crucial computing operations in signal processing, numerical simulations, and machine learning. In recent years, optical analog approaches have demonstrated higher computing performance and better power efficiency than their digital counterparts. However, analog computing chips usually need large areas and complex structures for parallel computing, as a single device element only executes one computing operation at a single time. Here, we demonstrate frequency-domain computing using the nonlinear acoustic-wave devices on lithium niobate, featuring a normalized external second-harmonic generation conversion efficiency of ~ 5.7 × 10-4 W-1. The second-order sum-frequency nonlinear process of lithium niobate enables multiplication of inputs encoded in the frequency domain. Compared to the analog schemes, our device features a notably simpler design, and nanofabrication requires only one lift-off. Using a single acoustic-wave device within an area of 0.03 mm2, we can simultaneously conduct over 130,000 multiply-accumulation operations. Our acoustic-wave device shows applications in real and complex vector convolutions and image processing. This demonstration sets the stage for experimental realizations into frequency-domain integrated nonlinear acoustic computing systems, potentially shaping future developments in acoustic neural networks and quantum computing.

chai, mingzhao (ORCID:0009000466226341)↗

Integration of conductivity probe with optical and x-ray imaging systems for local air–water two-phase flow measurement

Various techniques have been developed in the past to measure different parameters in two-phase flow. Among them, the multi-sensor conductivity probe is one of the most commonly used techniques because of its good overall performance. Recently, more advanced techniques such as high speed optical imaging and fast X-ray densitometry become mature and easily accessible. The main objective of this work is to compare and integrate these different techniques, to achieve a more accurate and complete measurement of two-phase flow. In this study, a double-sensor conductivity probe is used to measure the local time-averaged parameters along the radial direction of a 2.54 cm ID round pipe. An X-ray densitometry system is used to measure the chordal averaged void fraction and gas velocity. A high speed camera system is employed to provide the visualization of the two-phase flow structure and obtain the line-averaged gas velocity. The unique advantages and main uncertainties of these three techniques are analyzed by considering their measuring principles and possible issues in practical measurements. From this, a method is developed to integrate the data obtained by the optical and X-ray systems into the probe signal processing. Finally, a better accuracy could be achieved using this method for various local two-phase flow parameters including void fraction, bubble velocity and superficial gas velocity, compared to the original probe measurements.

42 ENGINEERING↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Roadmap on semiconductor–cell biointerfaces

This roadmap outlines the role semiconductor-based materials play in understanding the complex biophysical dynamics at multiple length scales, as well as the design and implementation of next-generation electronic, optoelectronic, and mechanical devices for biointerfaces. The roadmap emphasizes the advantages of semiconductor building blocks in interfacing, monitoring, and manipulating the activity of biological components, and discusses the possibility of using active semiconductor-cell interfaces for discovering new signaling processes in the biological world.

59 BASIC BIOLOGICAL SCIENCES↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Longitudinal bunch monitoring at the Fermilab Tevatron and Main Injector synchrotrons

The measurement of the longitudinal behavior of the accelerated particle beams at Fermilab is crucial to the optimization and control of the beam and the maximizing of the integrated luminosity for the particle physics experiments. Longitudinal measurements in the Tevatron and Main Injector synchrotrons are based on the analysis of signals from resistive wall current monitors. This study describes the signal processing performed by a 2 GHz-bandwidth oscilloscope together with a computer running a LabVIEW program which calculates the longitudinal beam parameters.

43 PARTICLE ACCELERATORS↗

Roadmap on transformation optics

Transformation optics asks, using Maxwell's equations, what kind of electromagnetic medium recreates some smooth deformation of space? The guiding principle is Einstein's principle of covariance: that any physical theory must take the same form in any coordinate system. This requirement fixes very precisely the required electromagnetic medium. The impact of this insight cannot be overestimated. Many practitioners were used to thinking that only a few analytic solutions to Maxwell's equations existed, such as the monochromatic plane wave in a homogeneous, isotropic medium. At a stroke, transformation optics increases that landscape from 'few' to 'infinity', and to each of the infinitude of analytic solutions dreamt up by the researcher, there corresponds an electromagnetic medium capable of reproducing that solution precisely. The most striking example is the electromagnetic cloak, thought to be an unreachable dream of science fiction writers, but realised in the laboratory a few months after the papers proposing the possibility were published. But the practical challenges are considerable, requiring meta-media that are at once electrically and magnetically inhomogeneous and anisotropic. How far have we come since the first demonstrations over a decade ago? And what does the future hold? If the wizardry of perfect macroscopic optical invisibility still eludes us in practice, then what compromises still enable us to create interesting, useful, devices? While three-dimensional (3D) cloaking remains a significant technical challenge, much progress has been made in two dimensions. Carpet cloaking, wherein an object is hidden under a surface that appears optically flat, relaxes the constraints of extreme electromagnetic parameters. Surface wave cloaking guides sub-wavelength surface waves, making uneven surfaces appear flat. Two dimensions is also the setting in which conformal and complex coordinate transformations are realisable, and the possibilities in this restricted domain do not appear to have been exhausted yet. Beyond cloaking, the enhanced electromagnetic landscape provided by transformation optics has shown how fully analytic solutions can be found to a number of physical scenarios such as plasmonic systems used in electron energy loss spectroscopy and cathodoluminescence. Are there further fields to be enriched? A new twist to transformation optics was the extension to the spacetime domain. By applying transformations to spacetime, rather than just space, it was shown that events rather than objects could be hidden from view; transformation optics had provided a means of effectively redacting events from history. The hype quickly settled into serious nonlinear optical experiments that demonstrated the soundness of the idea, and it is now possible to consider the practical implications, particularly in optical signal processing, of having an 'interrupt-without-interrupt' facility that the so-called temporal cloak provides. Inevitable issues of dispersion in actual systems have only begun to be addressed. Now that time is included in the programme of transformation optics, it is natural to ask what role ideas from general relativity can play in shaping the future of transformation optics. Indeed, one of the earliest papers on transformation optics was provocatively titled 'General Relativity in Electrical Engineering'. The answer that curvature does not enter directly into transformation optics merely encourages us to speculate on the role of transformation optics in defining laboratory analogues. Quite why Maxwell's theory defines a 'perfect' transformation theory, while other areas of physics such as acoustics are not apparently quite so amenable, is a deep question whose precise, mathematical answer will help inform us of the extent to which similar ideas can be extended to other fields. Here, the contributors to this Roadmap, who are all renowned practitioners or inventors of transformation optics, will give their perspectives into the field's status and future development.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast infrared plasmon switching in aligned carbon-nanotube optical resonators

Reconfigurable plasmonic materials are crucial components in active photonic devices for optical communication, signal processing, and sensing applications. Certain candidates including transparent conducting oxides, small-bandgap semiconductors (i.e. Ge, InSb), and conducting polymers can exhibit switchable free carrier concentrations triggered by optical, electrical or thermal excitations. Here, we show that aligned films of single-walled carbon nanotubes (SWCNTs) can serve as all-optically tunable plasmonic material in the mid-infrared range, thereby adding them to the library of switchable plasmonic materials. Interband optical pumping with femtosecond laser pulses results in the photoexcitation of free charge carriers, which transiently blueshifts the plasmon resonances of patterned, periodic SWCNT nano-resonators spanning the mid-infrared spectral range from 1700 to 2700 cm -1 . Furthermore. the ultrafast plasmon modulation exhibits a nearly single-picosecond decay time, attributed to interband carrier relaxation and inter-tube charge transfer. Given that aligned films of SWCNTs have high thermal stability, excellent photostability, epsilon-near-zero property, and extremely large optical anisotropy, their dynamic tunability represents a promising pathway towards active optical devices in the technologically important mid-infrared range.

single-walled carbon nanotubes↗

Smart pixel sensors: towards on-sensor filtering of pixel clusters with deep learning

Highly granular pixel detectors allow for increasingly precise measurements of charged particle tracks. Next-generation detectors require that pixel sizes will be further reduced, leading to unprecedented data rates exceeding those foreseen at the High- Luminosity Large Hadron Collider. Signal processing that handles data incoming at a rate of $\mathcal{O}$(40 MHz) and intelligently reduces the data within the pixelated region of the detector at rate will enhance physics performance at high luminosity and enable physics analyses that are not currently possible. Using the shape of charge clusters deposited in an array of small pixels, the physical properties of the traversing particle can be extracted with locally customized neural networks. In this first demonstration, we present a neural network that can be embedded into the on-sensor readout and filter out hits from low momentum tracks, reducing the detector's data volume by 57.1%–75.7%. The network is designed and simulated as a custom readout integrated circuit with 28 nm CMOS technology and is expected to operate at less than 300 μW with an area of less than 0.2 mm 2 . The temporal development of charge clusters is investigated to demonstrate possible future performance gains, and there is also a discussion of future algorithmic and technological improvements that could enhance efficiency, data reduction, and power per area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A review of non-cognitive applications for neuromorphic computing

Abstract Though neuromorphic computers have typically targeted applications in machine learning and neuroscience (‘cognitive’ applications), they have many computational characteristics that are attractive for a wide variety of computational problems. In this work, we review the current state-of-the-art for non-cognitive applications on neuromorphic computers, including simple computational kernels for composition, graph algorithms, constrained optimization, and signal processing. We discuss the advantages of using neuromorphic computers for these different applications, as well as the challenges that still remain. The ultimate goal of this work is to bring awareness to this class of problems for neuromorphic systems to the broader community, particularly to encourage further work in this area and to make sure that these applications are considered in the design of future neuromorphic systems.

97 MATHEMATICS AND COMPUTING↗