Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Swirl-can combustor segment

Combustor produces uniform circumferential and radial combustor exit temperature profiles and high combustion efficiency at high temperature loads. Absence of diluent air entry ports eliminates stress concentration points, low pressure fuel alleviates nozzle fouling, and abundant air at all burning stages reduces smoke.

Jones, R.↗

Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

Source record↗

Pyrotechnic hazards classification and evaluation program. Phase 2, segment 1: Records and experience analysis

A comprehensive search review and analysis was made of various technical documents relating to both pyrotechnics and high explosives testing, handling, storage, manufacturing, physical and chemical characteristics and accidents and incidents. Of approximately 5000 technical abstracts reviewed, 300 applicable documents were analyzed in detail. These 300 documents were then converted to a subject matrix so that they may be readily referenced for application to the current programs. It was generally concluded that information in several important categories was lacking. Two of the more important categories were in pyrotechnics sensitivity testing and TNT equivalency testing. A general recommendation resulting from this study was that this activity continue and a comprehensive data bank be generated that would allow immediate access to a large volume of pertinent information in a relatively short period of time.

Source record↗

Pyrotechnic hazards classification and evaluation program. Phase 2, segment 3: Test plan for determining hazards associated with pyrotechnic manufacturing processes

A comprehensive test plan for determining the hazards associated with pyrotechnic manufacturing processes is presented. The rationale for each test is based on a systematic analysis of historical accounts of accidents and a detailed study of the characteristics of each manufacturing process. The most hazardous manufacturing operations have been determined to be pressing, mixing, reaming, and filling. The hazard potential of a given situation is evaluated in terms of the probabilities of initiation, communication, and transition to detonation (ICT). The characteristics which affect the ICT probabilities include the ignition mechanisms which are present either in normal or abnormal operation, the condition and properties of the pyrotechnic material, and the configuration of the processing equipment. Analytic expressions are derived which describe the physical conditions of the system, thus permitting a variety of processes to be evaluated in terms of a small number of experiments.

Source record↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

Spontaneous ignition in afterburner segment tests at an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM jet-A fuel

A brief testing program was undertaken to determine if spontaneous ignition and stable combustion could be obtained in a jet engine afterburning operating with an inlet temperature of 1240 K and a pressure of 1 atmosphere with ASTM Jet-A fuel. Spontaneous ignition with 100-percent combustion efficiency and stable burning was obtained using water-cooled fuel spraybars as flameholders.

Schultz, D. F.↗

Selective data segment monitoring system

High speed data monitoring apparatus is described for displaying the bit pattern of a selected portion of a block of transmitted data comprising a shift register for receiving the transmitted data and for temporarily containing the consecutive data bits. A programmable sync detector for monitoring the contents of the shift register and for generating a sync signal when the shift register contains a predetermined sync code is included. A counter is described for counting the data bits input to the shift register after the sync signal is generated and for generating a count complete signal when a selected number of data bits have been input to the register. A data storage device is used for storing the contents of the shift register at the time the count complete signal is generated.

Wirth, M. N.↗

The lumbosacral segment as a vulnerable region in various postures

The lumbosacral region in man is exposed to special static and dynamic load. In a supine position, the disc size increases because of the absence of axial load. In a standing position, with physiological posture of the spine, strain discomfort occurs which is increased even more in the sitting position due to the curvature of the lumbar region of the spine and the irregular distribution of pressure in the discs as a result of this. This special problem of sitting posture can be confirmed by examinations.

Rosemeyer, B.↗