Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Navigation for space shuttle approach and landing using an inertial navigation system augmented by data from a precision ranging system or a microwave scan beam landing guidance system

A preliminary study has been made of the navigation performance which might be achieved for the high cross-range space shuttle orbiter during final approach and landing by using an optimally augmented inertial navigation system. Computed navigation accuracies are presented for an on-board inertial navigation system augmented (by means of an optimal filter algorithm) with data from two different ground navigation aids; a precision ranging system and a microwave scanning beam landing guidance system. These results show that augmentation with either type of ground navigation aid is capable of providing a navigation performance at touchdown which should be adequate for the space shuttle. In addition, adequate navigation performance for space shuttle landing is obtainable from the precision ranging system even with a complete dropout of precision range measurements as much as 100 seconds before touchdown.

Mcgee, L. A.↗

Capabilities of a single scan TV-radiographic system for digital data acquisition.

A single scan TV-radiography system capable of providing analogue signals ready for A-D conversion for input to a computer has been investigated. Modulation transfer functions of both horizontal and vertical resolution have been obtained. The capability for gray scale reproduction was also investigated. The output data rate of the system is 16 KHz thereby providing compatibility to A-D converters generally available for most computers. In general, the capability of the system was found to exceed the input capabilities of available image-amplifiers and is therefore acceptable for quantitative fluoroscopic applications.

Baily, N. A.↗

Endolithic algae and micrite envelope formation in Bahamian oolites as revealed by scanning electron microscopy.

Examination of Holocene Bahamian ooelites by scanning electron and light microscopy has revealed the morphology and orientation of aragonite crystals in the lamellar ooelitic envelope, and their modification by the boring activities of endolithic algae. The voids produced by these algae are found in progressive stages of being lined and filled with precipitated microcrystalline aragonite, which is similar to the process of micrite envelope formation in molluscan and other skeletal carbonate grains.

Margolis, S.↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Interval scanning photomicrography of microbial cell populations.

A single reproducible area of the preparation in a fixed focal plane is photographically scanned at intervals during incubation. The procedure can be used for evaluating the aerobic or anaerobic growth of many microbial cells simultaneously within a population. In addition, the microscope is not restricted to the viewing of any one microculture preparation, since the slide cultures are incubated separately from the microscope.

Casida, L. E., Jr.↗

Scanning mirror for infrared sensors

A high resolution, long life angle-encoded scanning mirror, built for application in an infrared attitude sensor, is described. The mirror uses a Moire' fringe type optical encoder and unique torsion bar suspension together with a magnetic drive to meet stringent operational and environmental requirements at a minimum weight and with minimum power consumption. Details of the specifications, design, and construction are presented with an analysis of the mirror suspension that allows accurate prediction of performance. The emphasis is on mechanical design considerations, and brief discussions are included on the encoder and magnetic drive to provide a complete view of the mirror system and its capabilities.

Anderson, R. H.↗

A scan processor as an aid to program documentation

Program documentation was separated into two catagories: documentation for program use and documentation for program analysis, modification, or extension. The symbol scanner, flow chart production subsystem, decision table subsystem, and scan processor are also described.

Oliver, P.↗

Uneven drive rates of the scanning telescope: Apollo 16 mission

An investigation was made into the cause or causes of uneven drive rates during operation of the Apollo 16 scanning telescope. It was suggested that such erratic behavior was caused by either changes in the characteristics noise level of the optics counter on the panels or the repositioning process by the computer or zero optics mode. Test results show the anomaly was not caused by either of the above suggestions, instead they were caused by a broken socket spring in the telescope harness. New harnesses will be manufactured for future flights.

Source record↗

A silicon vidicon camera for slow scan operation

A silicon vidicon camera was designed, built, and tested to determine its potential for use aboard future Mariner spacecraft. Slow scan operation is made possible by cooling the vidicon to -40 C. Cooling is achieved by a simple thermal condition path between the vidicon and a radiator mounted on top of the camera head. The camera was successfully operated under simulated space flight conditions and has survived vibration designed to simulate the launch of a Mariner spacecraft. A description of the camera and its operation along with the results of the testing is presented.

Potter, W. M.↗

Electrically scanning microwave radiometer for Nimbus E

An electronically scanning microwave radiometer system has been designed, developed, and tested for measurement of meteorological, geomorphological and oceanographic parameters from NASA/GSFC's Nimbus E satellite. The system is a completely integrated radiometer designed to measure the microwave brightness temperature of the earth and its atmosphere at a microwave frequency of 19.35 GHz. Calibration and environmental testing of the system have successfully demonstrated its ability to perform accurate measurements in a satellite environment. The successful launch and data acquisition of the Nimbus 5 (formerly Nimbus E) gives further demonstration to its achievement.

Source record↗

Measurement of dihedral angles by scanning electron microscopy.

The extension of Hoover's (1971) technique to the case of dihedral-angle measurement is described. Dihedral angles are often determined by interferometry on thermally grooved grain boundaries to obtain information on relative interfacial energies. In the technique considered the measured angles approach the true angles as the tilt angle approaches 90 deg. It is pointed out that the scanning electron microscopy method provides a means of seeing the real root of a groove at a lateral magnification which is higher than that obtainable with interferometry.

Achutaramayya, G.↗

Study of fretting wear in titanium, Monel-400, and cobalt-25 percent molybdenum using scanning electron microscopy.

Damage scar volume measurements taken from like metal fretting pairs, combined with scanning electron microscopy observations, showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt-25% molybdenum. Initially, adhesion and plastic deformation on the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism, producing spall-like pits in the damage scar. Finally, an oxidation-related mechanism became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

Bill, R. C.↗

Photon counting with a self-scanned diode array.

A self-scanned diode array may be used as temporary storage for individual photons if enough gain is provided by an image intensifier or electron multiplier to provide a detectable signal from each input event.

Mcnall, J. F.↗

Effect of radiometric errors on accuracy of temperature-profile measurement by the spectral-scanning method.

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators and radiometers outside of the gas stream, and there is no interference with the flow. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, the strength of line absorption, and the absorption coefficient and its temperature coefficient. These influence the choice of wavelengths for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two wavelength measurement on a family of profiles that may be expected in a practical case of H2 - O2 combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗

Infrared scanning radiometer

The Apollo 17 infrared scanning radiometer (ISR) experiment for mapping lunar surface thermal emission is reported. The instrument, lunar surface coverage, and the data obtained are discussed.

Low, F. J.↗

Dynamic-scanning-electron-microscope study of friction and wear

A friction and wear apparatus was built into a real time scanning electron microscope (SEM). The apparatus and SEM comprise a system which provides the capability of performing dynamic friction and wear experiments in situ. When the system is used in conjunction with dispersive X-ray analysis, a wide range of information on the wearing process can be obtained. The type of wear and variation with speed, load, and time can be investigated. The source, size, and distribution of wear particles can be determined and metallic transferal observed. Some typical results obtained with aluminum, copper, and iron specimens are given.

Brainard, W. A.↗