Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Methane, ethane, and propane production in Greenland ice core samples and a first isotopic characterization of excess methane

Air trapped in polar ice provides unique records of the past atmospheric composition ranging from key greenhouse gases such as methane (CH 4 ) to short-lived trace gases like ethane (C 2 H 6 ) and propane (C 3 H 8 ). Recently, the comparison of CH 4 records obtained using different extraction methods revealed disagreements in the CH 4 concentration for the last glacial in Greenland ice. Elevated methane levels were detected in dust-rich ice core sections measured discretely, pointing to a process sensitive to the melt extraction technique. To shed light on the underlying mechanism, we performed targeted experiments and analyzed samples for methane and the short-chain alkanes ethane and propane covering the time interval from 12 to 42 kyr. Here, we report our findings of these elevated alkane concentrations, which scale linearly with the amount of mineral dust within the ice samples. The alkane production happens during the melt extraction step of the classic wet-extraction technique and reaches 14 to 91 ppb of CH 4 excess in dusty ice samples. We document for the first time a co-production of excess methane, ethane, and propane, with the observed concentrations for ethane and propane exceeding their past atmospheric background at least by a factor of 10. Independent of the produced amounts, excess alkanes were produced in a fixed molar ratio of approximately 14 : 2 : 1, indicating a shared origin. The measured carbon isotopic signature of excess methane is (-47.0 ± 2.9) ‰ and its deuterium isotopic signature is (-326 ± 57) ‰. With the co-production ratios of excess alkanes and the isotopic composition of excess methane we established a fingerprint that allows us to constrain potential formation processes. This fingerprint is not in line with a microbial origin. Moreover, an adsorption–desorption process of thermogenic gas on dust particles transported to Greenland does not appear very likely. Instead, the alkane pattern appears to be indicative of abiotic decomposition of organic matter as found in soils and plant leaves.

54 ENVIRONMENTAL SCIENCES↗

A globally sampled high-resolution hand-labeled validation dataset for evaluating surface water extent maps

Effective monitoring of global water resources is increasingly critical due to climate change and population growth. Advancements in remote sensing technology, specifically in spatial, spectral, and temporal resolutions, are revolutionizing water resource monitoring, leading to more frequent and high-quality surface water extent maps using various techniques such as traditional image processing and machine learning algorithms. However, satellite imagery datasets contain trade-offs that result in inconsistencies in performance, such as disparities in measurement principles between optical (e.g., Sentinel-2) and radar (e.g., Sentinel-1) sensors and differences in spatial and spectral resolutions among optical sensors. Therefore, developing accurate and robust surface water mapping solutions requires independent validations from multiple datasets to identify potential biases within the imagery and algorithms. However, high-quality validation datasets are expensive to build, and few contain information on water resources. For this purpose, we introduce a globally sampled, high-spatial-resolution dataset labeled using 3 m PlanetScope imagery. Our surface water extent dataset comprises 100 images, each with a size of 1024×1024 pixels, which were sampled using a stratified random sampling strategy covering all 14 biomes. We highlighted urban and rural regions, lakes, and rivers, including braided rivers and coastal regions. We evaluated two surface water extent mapping methods using our dataset – Dynamic World, based on Sentinel-2, and the NASA IMPACT model, based on Sentinel-1. Dynamic World achieved a mean intersection over union (IoU) of 72.16 % and F1 score of 79.70 %, while the NASA IMPACT model had a mean IoU of 57.61 % and F1 score of 65.79 %. Performance varied substantially across biomes, highlighting the importance of evaluating models on diverse landscapes to assess their generalizability and robustness. Our dataset can be used to analyze satellite products and methods, providing insights into their advantages and drawbacks. Our dataset offers a unique tool for analyzing satellite products, aiding the development of more accurate and robust surface water monitoring solutions. The dataset can be accessed via https://doi.org/10.25739/03nt-4f29.

54 ENVIRONMENTAL SCIENCES↗

Sample analysis systems and methods of use thereof

The invention generally relates to sample analysis systems and methods of use thereof. In certain aspects, the invention provides a system for analyzing a sample that includes an ion generator configured to generate ions from a sample. The system additionally includes an ion separator configured to separate at or above atmospheric pressure the ions received from the ion generator without use of laminar flowing gas, and a detector that receives and detects the separated ions.

42 ENGINEERING↗

Electrothermal vaporization as a new method for pre-inspection check samples

The use of electrothermal vaporization (ETV) has not been readily applied to nuclear safeguards or pre inspection check (PIC) sample analysis, even though the technique is ideally suited for low level (pg) isotopic quantification due to its high analyte transport efficiency. Here demonstrate the ETV method for PIC safeguard analysis. The ETV system is an automated, commercial of the shelf (COTS) technology, with the capability to introduce solid samples to a mass spectrometer platform. The system has been shown to simultaneously determine uranium assay, and the major isotopic ratios for uranium and plutonium. The ETV unit has demonstrated analysis up to 50 samples a day autonomously. The utilization of this ETV methodology provide a secondary option to the current PIC analysis and offers high throughput, enhanced sensitivity, and broader isotopic detection platform.

Hexel, Cole↗

Dark Energy Survey Year 6 Results: MagLim++ Lens Sample Selection and Measurements of Galaxy Clustering

Galaxy clustering is a sensitive probe of the expansion history and growth of structure of the universe, and key degeneracies can be broken by combining these data with measurements of cosmic shear and galaxy-galaxy lensing (a so-called 3$\times$2pt analysis). The largest and least biased statistical samples of galaxies for use in clustering analyses can be collected photometrically through large imaging surveys. However, selecting clean photometric subsamples for cosmology are crucial for avoiding contamination that can bias cosmological constraints. Here we present the MagLim++ galaxy sample, selected to optimize for cosmological constraining power and incorporating an array of novel quality cuts to identify and remove residual contamination. This sample comes from the full six years of observations from the Dark Energy Survey. We present measurements of the two-point angular clustering ($w(θ)$) of 9,186,205 galaxies distributed over 4031 sq. degrees and in six tomographic redshift bins centered at $\bar{z}\approx$ [0.31, 0.44, 0.62, 0.78, 0.90, 1.01]. These measurements are used as part of the 3$\times$2pt and other DES Y6 legacy cosmological analyses in companion works. We describe the battery of null tests and mitigation schemes implemented to address observational, astrophysical, and methodological systematics in the analysis. The resulting $w(θ)$ measurements have a S/N = 149 (90.2 for linear scales only), which we use to place galaxy-clustering-only constraints on the matter density of the Universe, $Ω_m=0.311^{+0.023}_{-0.035}$, and amplitude of galaxy clustering in each redshift bin, $b_iσ_8=[1.16^{+0.04}_{-0.06},\ 1.40^{+0.04}_{-0.06},\ 1.57^{+0.04}_{-0.06},\ 1.59^{+0.04}_{-0.05},\ 1.50^{+0.04}_{-0.05},\ 1.74^{+0.06}_{-0.08}]$.

Weaverdyck, N. [BCCP, Berkeley; UC, Berkeley; LBL,↗

The OSIRIS-REx Sample Return Capsule re-entry: A coordinated seismo-acoustic observational campaign for the study of meteor phenomena

Objects entering Earth’s atmosphere at hypersonic velocities may generate powerful acoustic waves. Depending on atmospheric conditions and acoustic propagation paths, they may be captured using ground or balloon-borne microbarometers and microphones. Impacts into the Earth’s atmosphere by asteroids in a meter-size range are sporadic and unannounced, and thus, well-documented scientific observations of asteroids are rare and generally happen by chance. Arriving from interplanetary space at hypervelocity, spacecraft are considered analogues for low velocity meteoroids and asteroids impacting the Earth’s atmosphere, and as such provide unprecedented and unique opportunity to carry out planned observational campaigns and perform detailed studies of meteor phenomena. However, since the end of the Apollo era, only four instances of a hypersonic re-entry of an artificial body from interplanetary space with an incident speed of 11-12 km/s have been observed and studied. These were the Sample Return Capsules (SRCs) that brought physical samples of extraterrestrial material back to Earth (Genesis, Stardust, Hayabusa 1, Hayabusa 2). These re-entries were also detected by infrasound and/or seismic sensors. The next opportunity to observe an artificial meteor will be on 24 September 2023 with the re-entry of NASA’s OSIRIS-REx SRC that will bring samples of the carbonaceous near-Earth asteroid Bennu. The re-entry consists of several flight phases, including hypersonic and supersonic, providing a unique opportunity to observe these by infrasound and seismic sensors. We will discuss observational campaign efforts aimed to capture geophysical signals generated by the OSIRIS-REx SRC re-entry. This campaign utilizes an unparalleled number of instruments, both ground and airborne, strategically positioned in the immediate and extended region around the projected re-entry trajectory to maximize the scientific output.

47 - OTHER INSTRUMENTATION↗

Flow cell and sampling probe

The present disclosure is directed to optical flow cells and sampling probes, and, more specifically, to optical flow cells and sampling probes useful for in-line sampling and optical measurements of particles in industrial fluids and combustion flue gas.

Axelbaum, Richard↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Broadband Photoconductive Sampling in Gallium Phosphide

Abstract Direct measurements of the electric field of light enable new observations of light–matter interactions. In the near‐infrared and visible spectral ranges, this typically relies on techniques that exploit nonlinearities in gases or solids, which limits their sensitivity. Here, a method for the detection of broadband near‐infrared fields spanning more than one octave from 110 to 220 THz based on linear absorption in a semiconductor is demonstrated. This technique, which avoids complex vacuum setups and works under ambient conditions, employs linear photoconductive sampling (LPS) in gallium phosphide. Simulations reveal that the response function of LPS is concerned with the intensity envelope of the gate field, in contrast to electro‐optic sampling, relaxing the stringent temporal requirements on the gate pulse.

36 MATERIALS SCIENCE↗

HHL algorithm with mapping function and enhanced sampling for model predictive control in microgrids

Here, this paper presents a refined quantum Harrow Hassidim Lloyd (HHL) algorithm for microgrid control. The first novelty of the developed method is that a mapping shift function enables the original HHL algorithm to handle general linear equations with non-singular and indefinite matrix. Second, a method of Matrix Extension for Amplifying Sampling Probabilities of Intended Solution (ME-ASPI) is proposed to design the reformulated linear algebraic equations, allowing for improved sampling efficiency of the quantum tomography in the refined HHL algorithm. Then, we applied the method to solve the model predictive control (MPC) problem in nonlinear dynamical microgrids. Specifically, with the ME-ASPI method, the refined HHL algorithm can effectively obtain the intended partial optimal control inputs for MPC. The optimization of quadratic programming problem in each time step of MPC is transformed into a linear system problem, which is addressed by the proposed quantum solver through using only partial information, with the time complexity improved from $\mathscr{O}(\mathscr{N}^{2.37286})$ classically to $\mathscr{O}(\mathscr{N}^{2} log \mathscr{N}$ x $p$ log $p)$ in quantum. Numerical examples have validated the effectiveness of the refined HHL algorithm with the proposed mapping function and the ME-ASPI method. By leveraging quantum properties, the proposed method provides a hybrid quantum–classical framework for microgrid control. This generic method can also potentially tackle many other challenges in analyzing and controlling general complex engineered systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing stream temperature prediction with a generalizable large-sample framework across CONUS river reaches

Accurately predicting stream temperature in ungauged basins remains a critical challenge for water resource management, thermoelectric power plant cooling, and ecosystem conservation. Large-sample machine learning models trained on hundreds of well-monitored river basins have shown remarkable performance; however, such models have yet to be developed solely using forcing data that can be readily extracted to simulate stream temperatures anywhere in the contiguous United States (CONUS). In this study, we present a scalable, large-sample deep learning framework using Long Short-Term Memory (LSTM) networks to simulate daily stream temperatures in ungauged basins across the CONUS. The framework leverages both modeled reanalysis of meteorological and streamflow inputs as well as static attributes available for all 2.7 million CONUS river reaches in the National Hydrography Dataset Plus (NHDPlusV2). By generating dynamical inputs from predefined thermally relevant upstream contributing areas, rather than the entire upstream basin, the model also offers improvements in very large basins where full-basin averaging can dilute the most important influences on stream temperature. Evaluated across 300 basins, the model achieves a median Mean Absolute Error (MAE) of 1.1 °C and a Nash-Sutcliffe Efficiency (NSE) of 0.95 on temporally and spatially distinct test folds—comparable to models trained exclusively using meteorological and streamflow observational data. The flexible, high-performing framework generalizes to any unmonitored river reach without significant regulation or unnatural thermal input immediately upstream, substantially expanding predictive capabilities in data-scarce regions.

Hydrology↗

Conditional Point Sampling: A Monte Carlo Method for Radiation Transport in Stochastic Media.

Current methods for stochastic media transport are either computationally expensive or, by nature, approximate. Moreover, none of the well-developed, benchmarked approximate methods can compute the variance caused by the stochastic mixing, a quantity especially important to safety calculations. Therefore, we derive and apply a new conditional probability function (CPF) for use in the recently developed stochastic media transport algorithm Conditional Point Sampling (CoPS), which 1) leverages the full intra-particle memory of CoPS to yield errorless computation of stochastic media outputs in 1D, binary, Markovian-mixed media, and 2) leverages the full inter-particle memory of CoPS and the recently developed Embedded Variance Deconvolution method to yield computation of the variance in transport outputs caused by stochastic material mixing. Numerical results demonstrate errorless stochastic media transport as compared to reference benchmark solutions with the new CPF for this class of stochastic mixing as well as the ability to compute the variance caused by the stochastic mixing via CoPS. Using previously derived, non-errorless CPFs, CoPS is further found to be more accurate than the atomic mix approximation, Chord Length Sampling (CLS), and most of memory-enhanced versions of CLS surveyed. In addition, we study the compounding behavior of CPF error as a function of cohort size (where a cohort is a group of histories that share intra-particle memory) and recommend that small cohorts be used when computing the variance in transport outputs caused by stochastic mixing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aggregated nanoparticles: Sample preparation and analysis by atom probe tomography

Atom probe tomography (APT) allows measurement of the three-dimensional structure and composition of materials, but specific sample preparation procedures are required for challenging materials such as aggregates of nanoparticles. Indeed, the presence of porosity within the specimen affects both the stability of the sample and the accuracy of the data. In this work, aggregates of nanoparticles were transferred onto a micromanipulator tip and embedded via electron-beam-assisted deposition of Pt. Successive FIB-millings and Pt-depositions are needed to create suitable APT tips. The 3D reconstruction reveals the presence of 15–20 nm nanoparticles, and massspectral analysis shows the absence of trace elements within the catalyst, thus serving as quality control for the synthesis of nanoparticles with specific compositions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra-Microtome for the Preparation of TEM Samples from Battery Cathodes

An ultra-microtome method is developed for the preparation of transmission electron microscopy (TEM) specimens from the cathodes of Li-ion battery. Results indicate that the samples prepared with the ultra-microtome method yield atomic resolution imaging from the core area of particles of hundreds to thousands of nanometers. Analysis of the TEM samples prepared with ultra-microtome indicates that no observable structural damage, such as microcracking, is introduced during the cutting process, and the cathodes cut by ultra-microtome exhibit unchanged micro-morphologies compared with the uncut ones. These results demonstrate that ultra-microtome is a promising method for the preparation of TEM specimens and revealing in-depth microstructures of fragile materials such as battery cathodes.

transmission electron microscopy, Sample Preparati↗

Accelerated Nano-Optical Imaging through Sparse Sampling

The integration time and signal-to-noise ratio are inextricably linked when performing scanning probe microscopy based on raster scanning. This often yields a large lower bound on the measurement time, for example, in nano-optical imaging experiments performed using a scanning near-field optical microscope (SNOM). Here, in this study, we utilize sparse scanning augmented with Gaussian process regression to bypass the time constraint. We apply this approach to image charge-transfer polaritons in graphene residing on ruthenium trichloride (α-RuCl 3 ) and obtain key features such as polariton damping and dispersion. Critically, nano-optical SNOM imaging data obtained via sparse sampling are in good agreement with those extracted from traditional raster scans but require 11 times fewer sampled points. As a result, Gaussian process-aided sparse spiral scans offer a major decrease in scanning time.

36 MATERIALS SCIENCE↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Derivative-free stochastic optimization via adaptive sampling strategies

In this paper, we present a novel derivative-free framework for solving unconstrained stochastic optimization problems. Many problems in fields ranging from simulation optimization to reinforcement learning to quantum computing involve settings where only stochastic function values are obtained via a zeroth-order oracle, which has no available gradient information and necessitates the usage of derivative-free optimization methodologies. Our approach includes estimating gradients using stochastic function evaluations and integrating adaptive sampling techniques to control the accuracy in these stochastic approximations. Our framework encapsulates several gradient estimation techniques, including standard finite-difference, Gaussian smoothing, sphere smoothing, randomized coordinate finite-difference, and randomized subspace finite-difference methods. We provide theoretical convergence guarantees for our framework and analyze the worst-case iteration and sample complexities associated with each gradient estimation method. Finally, we demonstrate the empirical performance of the methods on logistic regression and nonlinear least squares problems.

Adaptive sampling↗