Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STANDARDIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The role of space data systems interface standards

This paper will discuss data systems interface standards including the goals and benefits in their application to space flight programs. Recent trends toward increased international cooperation in space research and applications missions have resulted in a greater emphasis on compatible interface standards among the participating agencies. The discussion will highlight the Consultative Committee for Space Data Systems (CCSDS), a consortium of 19 space agencies formed in 1982 in order to provide a technical forum for developing guidelines for compatible data systems standards among cooperating space agencies worldwide. CCSDS effort is seen as contributing significantly to the objectives of the IAF's Symposium on Space Exploration.

Stephens, R.↗

Wavelength dependence of position angle in polarization standards

Eleven of the 15 stars on Serkowski's (1974) list of 'Standard Stars with Large Interstellar Polarization' were investigated to determine whether the orientation of the plane of their linear polarization showed any dependence on wavelength. Nine of the eleven stars exhibited a statistically significant wavelength dependence of position angle when measured with an accuracy of about 0.1 deg standard deviation. For the majority of these stars, the effect is caused primarily by intrinsic polarization. The calibration of polarimeter position angles in a celestial coordinate frame must evidently be done at the 0.1 deg level of accuracy by using only carefully selected standard stars or by using other astronomical or laboratory methods.

Dolan, J. F.↗

Standards for the user interface - Developing a user consensus

The user support environment (USE) which is a set of software tools for a flexible standard interactive user interface to the Space Station systems, platforms, and payloads is described in detail. Included in the USE concept are a user interface language, a run time environment and user interface management system, support tools, and standards for human interaction methods. The goals and challenges of the USE are discussed as well as a methodology based on prototype demonstrations for involving users in the process of validating the USE concepts. By prototyping the key concepts and salient features of the proposed user interface standards, the user's ability to respond is greatly enhanced.

Moe, Karen L.↗

Atomic frequency standards for ultra-high-frequency stability

The general features of the Hg-199(+) trapped-ion frequency standard are outlined and compared to other atomic frequency standards, especially the hydrogen maser. The points discussed are those which make the trapped Hg-199(+) standard attractive: high line Q, reduced sensitivity to external magnetic fields, and simplicity of state selection, among others.

Maleki, L.↗

The JPL trapped mercury ion frequency standard

In order to provide frequency standards for the Deep Space Network (DSN) which are more stable than present-day hydrogen masers, a research task was established under the Advanced Systems Program of the TDA to develop a Hg-199(+) trapped ion frequency standard. The first closed-loop operation of this kind is described. Mercury-199 ions are confined in an RF trap and are state-selected through the use of optical pumping with 194 nm UV light from a Hg-202 discharge lamp. Absorption of microwave radiation at the hyperfine frequency (40.5 GHz) is signaled by atomic fluorescence of the UV light. The frequency of a 40.5 GHz oscillator is locked to a 1.6 Hz wide atomic absorption line of the trapped ions. The measured Allan variance of this locked oscillator is currently gamma sub y (pi) = 4.4 x 10 to the minus 12th/square root of pi for 20 is less than pi is less than 320 seconds, which is better stability than the best commercial cesium standards by almost a factor of 2. This initial result was achieved without magnetic shielding and without regulation of ion number.

Prestage, J. D.↗

Evaluation of the characteristics of a field emission cathode for use in a Mercury ion trap frequency standard

The performance is reported of a field emission array characterized for the purpose of replacing the filament in a trapped ion frequency standard. This dark electron emitter eliminates the need for the interference filter currently used in the trapped ion standard. While reducing the filament's unwanted light, this filter causes a significant reduction in the signal. The magnetic field associated with the filament is also eliminated, thus potentially improving the present stability of the trapped ion standard. The operation of the filament in the present system is described, as well as the associated concerns. The cathode considered for the filament's replacement is then described along with the experimental system. Experimental results, observations, and conclusions are presented.

Christman, J. M.↗

A reference standard for bidirectional reflection distribution function and bidirectional transmission distribution function measurement

A Lambertian reference standard for uniformly scattering a beam of light is constructed of a plate having a planar surface with a layer of glue disposed on the surface. An evenly packed layer of monodisperse spheres is set in the layer, and when the standard is used for bi-directional (BRDF) measurements, the spheres are coated with a layer of highly relective substance, such as gold or silver. When the standard is used for bi-directional transmittance distribution function (BTDF) measurements, the spheres are of a transparent material and are provided with a roughened surface, as by acid etching. In this case, the layer of glue is an optical cement, and the plate is of glass, with the spheres, the layer, and the plate all possessing a similar refractive index.

Witherow, William K.↗

USL/DBMS NASA/PC R and D project C programming standards

A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

Dominick, Wayne D.↗

NASA standard: Trend analysis techniques

This Standard presents descriptive and analytical techniques for NASA trend analysis applications. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. Use of this Standard is not mandatory; however, it should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend Analysis is neither a precise term nor a circumscribed methodology, but rather connotes, generally, quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this Standard. The document presents the basic ideas needed for qualitative and quantitative assessment of trends, together with relevant examples. A list of references provides additional sources of information.

Source record↗

Standard surface-reflectance model and illuminant estimation

A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.

Tominaga, Shoji↗

Executive overview and introduction to the SMAP information system life-cycle and documentation standards

An overview of the five volume set of Information System Life-Cycle and Documentation Standards is provided with information on its use. The overview covers description, objectives, key definitions, structure and application of the standards, and document structure decisions. These standards were created to provide consistent NASA-wide structures for coordinating, controlling, and documenting the engineering of an information system (hardware, software, and operational procedures components) phase by phase.

Source record↗

The next 40 years in space standards

Methods used in producing, introducing, and using standards for civilian space research are examined, with special consideration given to the recommendations of the Consultative Committee for Space Data Systems (CCSDS) as an example of a set of standards best coordinated through the International Standard Organization (ISO). The paper uses an example of earth-observation data as a CCSDS application for an international coordination effort within the ISO and describes progress in achieving this objective. Lists of CCDSD member agencies and CCSDS observer agencies are included.

Sheetz, H. J.↗

Lithium in halo stars from standard stellar evolution

A grid has been constructed of theoretical evolution sequences of models for low-metallicity stars from the premain-sequence to the giant branch phases. The grid is used to study the history of surface Li abundance during standard stellar evolution. The Li-7 observations of halo stars by Spite and Spite (1982) and subsequent observations are synthesized to separate the halo stars by age. The theory of surface Li abundance is illustrated by following the evolution of a reference halo star model from the contracting fully convective premain sequence to the giant branch phase. The theoretical models are compared with observed Li abundances. The results show that the halo star lithium abundances can be explained in the context of standard stellar evolution theory using completely standard assumptions and physics.

Deliyannis, Constantine P.↗

The classical microwave frequency standards

Some key problems are presented encountered in the classical microwave frequency standards which are still not solved today. The point of view expressed benefits from the experience gained both in the industry and in the research lab, on the following classical microwave frequency standards: active and passive H, conventional and laser pumped Cs beam tube, small conventional and laser pumped Rubidium. The accent is put on the Rubidium standard.

Busca, Giovanni↗

GPS Block 2R Time Standard Assembly (TSA) architecture

The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

Baker, Anthony P.↗

The physics of the environmental sensitivity of rubidium gas cell atomic frequency standards

Environmental sensitivity is often the most significant limitation to the practical stability of rubidium frequency standards (RFS). For example, temperature sensitivity can cause a rapid frequency change of several parts in 10(exp 10) for a tactical RFS that has an aging of only 1 times 10(exp -11)/month. Other important environmental factors are barometric pressure, vibration, magnetic field, and nuclear radiation. The physical mechanisms that lie behind these environmental sensitivities are considered. These physical mechanisms are related to the performance of actual rubidium frequency standards. For the user of these devices, a better knowledge of the causes for Rb clock instability will aid in their testing and proper application. For the time frequency specialist, a review of these factors may prove useful toward improving RFS design. Some of the RFS environmental sensitivities are due to simple physical mechanisms like the effect of dc magnetic field on the Rb hyperfine resonance frequency. For these, an analysis can be based on physical principles and straightforward design factors. Other environment factors, like temperature sensitivity, are more complex combinations of many effects, both physical and practical, and the analysis often takes the form of an error budget with large unit-to-unit variations. Today's rubidium frequency standards span a wide performance range from small, inexpensive units with pp 10(exp 10) error budgets to larger, higher performance versions offering pp 10(exp 10) stabilities. For both extremes, however, environmental sensitivity can be the most significant performance limitation. Why this is the case and how to make improvements are discussed.

Riley, William J.↗

Nitrogen abundances from UV lines of HgMn and standard late-B stars

A recent survey by Roby (1987) discovered that the relatively weak high excitation lines of N 1 near 7468 and 8680 A were undetectable in the majority of HgMn stars, leading to upper limits on the N abundance of roughly ten times below that of the solar N abundance. Standard stars with similar temperatures (10,000 to 13,000 K) did exhibit these same N lines and were found to have roughly solar N abundances. The N abundances were redetermined in two HgMn stars and four standard stars using the strong, low excitation lines of N 1 found in the ultraviolet. The observational data consisted of high quality, high resolution, co-added International Ultraviolet Explorer spectra which was previously collected and reduced. Examination of the spectra plus considerations of signal/noise and severe line blending led to the choice of three promising N 1 lines located at 1742.7, 1745.3 and 1411.9 A. The atomic data for these lines were previously calculated using the best laboratory measurements found in a search of the relevant literature. The chosen N lines turned out to be blended significantly with Fe 2 lines. To obtain the abundances for N synthetic spectra were computed to match the observed spectra. The synthetic spectra were calculated using lie-blanketed model atmospheres, stellar parameters, and abundances for the other elements based upon previous work by S. Adelman. The N abundance was then adjusted to give the best fit of the observed line profiles. In the 2 HgMn stars, the N lines were again found to be undetectable, but the stronger intrinsic strength of the new lines yield more stringent upper limits than those obtained previously. Model atmosphere and abundances were updated in two stars where new results were reported. An additional N 1 line and an additional standard star were added to the program. A line opacity model was developed for a missing feature adjacent to the N 1 line at 1745.2 A, leading to a 25 percent improvement in the determined from this line.

Roby, Scott W.↗

The Small Explorer Data System - A data system based on standard interfaces

The Small Explorer Data System was developed by NASA Goddard Space Flight Center using a 'standard interfaces' approach. Standard interfaces make it adaptable to a wide variety of missions. The paper describes the Small Explorer Data System with particular emphasis on the standard interfaces incorporated in both the hardware and software.

Smith, Brian S.↗