Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Long-Term Results for Trigeminal Schwannomas Treated With Gamma Knife Surgery

Purpose: Surgical resection is considered the desirable curative treatment for trigeminal schwannomas. However, complete resection without any complications remains challenging. During the last several decades, stereotactic radiosurgery (SRS) has emerged as a minimally invasive treatment modality. Information regarding long-term outcomes of SRS for patients harboring trigeminal schwannomas is limited because of the rarity of this tumor. The aim of this study was to evaluate long-term tumor control and functional outcomes in patients harboring trigeminal schwannomas treated with SRS, specifically with gamma knife surgery (GKS). Methods and Materials: Fifty-three patients harboring trigeminal schwannomas treated with GKS were evaluated. Of these, 2 patients (4%) had partial irradiation of the tumor, and 34 patients (64%) underwent GKS as the initial treatment. The median tumor volume was 6.0 cm{sup 3}. The median maximum and marginal doses were 28 Gy and 14 Gy, respectively. Results: The median follow-up period was 98 months. On the last follow-up image, 7 patients (13%) had tumor enlargement, including the 2 patients who had partial treatment. Excluding the 2 patients who had partial treatment, the actuarial 5- and 10-year progression-free survival (PFS) rates were 90% and 82%, respectively. Patients with tumors compressing the brainstem with deviation of the fourth ventricle had significantly lower PFS rates. If those patients with tumors compressing the brainstem with deviation of the fourth ventricle are excluded, the actuarial 5- and 10-year PFS rates increased to 95% and 90%, respectively. Ten percent of patients had worsened facial numbness or pain in spite of no tumor progression, indicating adverse radiation effect. Conclusions: GKS can be an acceptable alternative to surgical resection in patients with trigeminal schwannomas. However, large tumors that compress the brainstem with deviation of the fourth ventricle should be surgically removed first and then treated with GKS when necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Erlotinib Versus Radiation Therapy for Brain Metastases in Patients With EGFR-Mutant Lung Adenocarcinoma

Purpose/Objectives: Radiation therapy (RT) is the principal modality in the treatment of patients with brain metastases (BM). However, given the activity of EGFR tyrosine kinase inhibitors in the central nervous system, it is uncertain whether upfront brain RT is necessary for patients with EGFR-mutant lung adenocarcinoma with BM. Methods and Materials: Patients with EGFR-mutant lung adenocarcinoma and newly diagnosed BM were identified. Results: 222 patients were identified. Exclusion criteria included prior erlotinib use, presence of a de novo erlotinib resistance mutation, or incomplete data. Of the remaining 110 patients, 63 were treated with erlotinib, 32 with whole brain RT (WBRT), and 15 with stereotactic radiosurgery (SRS). The median overall survival (OS) for the whole cohort was 33 months. There was no significant difference in OS between the WBRT and erlotinib groups (median, 35 vs 26 months; P=.62), whereas patients treated with SRS had a longer OS than did those in the erlotinib group (median, 64 months; P=.004). The median time to intracranial progression was 17 months. There was a longer time to intracranial progression in patients who received WBRT than in those who received erlotinib upfront (median, 24 vs 16 months, P=.04). Patients in the erlotinib or SRS group were more likely to experience intracranial failure as a component of first failure, whereas WBRT patients were more likely to experience failure outside the brain (P=.004). Conclusions: The survival of patients with EGFR-mutant adenocarcinoma with BM is notably long, whether they receive upfront erlotinib or brain RT. We observed longer intracranial control with WBRT, even though the WBRT patients had a higher burden of intracranial disease. Despite the equivalent survival between the WBRT and erlotinib group, this study underscores the role of WBRT in producing durable intracranial control in comparison with a targeted biologic agent with known central nervous system activity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association Between Radiation Necrosis and Tumor Biology After Stereotactic Radiosurgery for Brain Metastasis

Background: The primary dose-limiting toxicity of stereotactic radiosurgery (SRS) is radiation necrosis (RN), which occurs after approximately 5% to 10% of treatments. This adverse event may worsen neurologic deficits, increase the frequency and cost of imaging, and necessitate prolonged treatment with steroids or antiangiogenic agents. Previous investigations have primarily identified lesion size and dosimetric constraints as risk factors for RN in small populations. We hypothesized that disease histology, receptor status, and mutational status are associated with RN. Methods and Materials: All patients presenting with brain metastasis between 1997 and 2015 who underwent SRS and subsequent radiographic follow-up at a single tertiary-care institution were eligible for inclusion. The primary outcome was the cumulative incidence of radiographic RN. Multivariate competing risks regression was used to identify biological risk factors for RN. Results: 1939 patients (5747 lesions) were eligible for inclusion; 285 patients (15%) experienced radiographic RN after the treatment of 427 (7%) lesions. After SRS, the median time to RN was 7.6 months. After multivariate analysis, graded prognostic assessment, renal pathology, lesion diameter, and the heterogeneity index remained independently predictive of RN in the pooled cohort. In subset analyses of individual pathologies, HER2-amplified status (hazard ratio [HR] 2.05, P=.02), BRAF V600+ mutational status (HR 0.33, P=.04), lung adenocarcinoma histology (HR 1.89, P=.04), and ALK rearrangement (HR 6.36, P<.01) were also associated with RN. Conclusions: In the present investigation constituting the largest series of RN, several novel risk factors were identified, including renal histology, lung adenocarcinoma histology, HER2 amplification, and ALK/BRAF mutational status. These risk factors may be used to guide clinical trial design incorporating biological risk stratification or dose escalation. Future studies determining the optimal timing of targeted therapies are warranted to further define the risk of RN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Radiosurgery for Resected Brain Metastases: The PROPS-BM Multicenter Cohort Study

Preoperative radiosurgery (SRS) is a feasible alternative to postoperative SRS, with potential benefits in adverse radiation effect (ARE) and leptomeningeal disease (LMD) relapse. However, previous studies are limited by small patient numbers and single-institution designs. Our aim was to evaluate preoperative SRS outcomes and prognostic factors from a large multicenter cohort (Preoperative Radiosurgery for Brain Metastases [PROPS-BM]).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicted cumulative dose to firefighters and the offsite public from natural and anthropogenic radionuclides in smoke from wildland fires at the Savannah River Site, South Carolina USA

The contaminated ground surface at Savannah River Site (SRS) is a result of the decades of work that has been performed maintaining the country's nuclear stockpile and performing research and development on nuclear materials. The volatilization of radionuclides during wildfire results in airborne particles that are dispersed within the smoke plume and may result in doses to downwind firefighters and the public. To better understand the risk that these smoke plumes present, we have characterized four regions at SRS in terms of their fuel characteristics and radiological contamination on the ground. Combined with general meteorological conditions describing typical and extreme burn conditions, we have simulated potential fires in these regions and predicted the potential radiological dose that could be received by firefighting personnel and the public surrounding the SRS. In all cases, the predicted cumulative dose was a small percent of the US Department of Energy regulatory limit (0.25 mSv). These predictions were conservative and assumed that firefighters would be exposed for the duration of their shift and the public would be exposed for the entire day over the duration of the burn. Realistically, firefighters routinely rotate off the firefront during their shift and the public would likely remain indoors much of the day. However, we show that even under worst-case conditions the regulatory limits are not exceeded. In conclusion, we can infer that the risks associated with wildfires would not be expected to cause cumulative doses above the level of concern to either responding personnel or the offsite public.

54 ENVIRONMENTAL SCIENCES↗

Strain rate sensitivity, microstructure variations, and stress-assisted β → α" phase transformation investigation on the mechanical behavior of dual-phase titanium alloys

In this study, the microstructures of three widely used dual-phase titanium alloys: Ti-6Al-4V, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-2Sn-4Zr-6Mo are characterized using backscatter electron imaging and the deformation behaviors in their individual α and β phases are investigated using in situ high-energy X-ray diffraction during uniaxial tension experiments. This is accompanied by calculation of the strain rate sensitivity (SRS) in these alloys, as a function of applied loading. The results of the calculated SRS and the mechanical response (in terms of lattice strains and hardening behaviors) are rationalized based on the local microstructure, composition, and texture of the alloy. A stress-induced β (BCC) to α" (orthorhombic) phase transformation is observed during the in-situ diffraction experiment, which permitted analysis of the lattice strain evolution during the phase transformation. Results from this study provide insights into the relationship between microstructure, composition, applied loading, and the deformation behavior, including effects on loading with time holds. Specifically, the results show that the microstructure, and not necessarily the chemical composition (Mo content), along with the applied loading have a dominant role in the observed SRS variation in titanium alloys. Further, the evolution of the α" (orthorhombic) phase is observed for the first time during deformation of an industrially relevant titanium alloy, Ti-6246.

36 MATERIALS SCIENCE↗

Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy

To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination and verification of a 2D pencil-beam kernel for a radiosurgery system with cones

The quality and correctness of dosimetric data of small fields in stereotactic radiosurgery (SRS) depends significantly on the election of the detector employed in the measurements. This work provides an independent method of verification of these data through the determination of a polyenergetic 2-dimensional pencil-beam kernel for a BrainLAB SRS system with cones, employing the deconvolution/convolution of a reference experimental off-axis ratio (OAR) profile (cone diameter c{sub 0} = 35 mm). The kernel in real space k{sub c{sub 0}}(r,z{sub 0}) is convolved with the ideal fluence Φ for the cones 7.5 to 35 mm in diameter to obtain the OAR profiles, and the total scatter factors, S{sub t}, which are compared with experimental values of the same quantities. The experimental OARs and S{sub t} factors are measured in water with a PTW 60003 diamond detector. Additionally, the reference OAR is corrected for beam divergence and spectral fluence fluctuations defining a function of boundary correction factors (BF). The BF and Φ functions are transformed to the conjugate space with the zeroth-order Hankel transform, appropriated to the radial symmetry of the cones. Therefore, the kernel in real space k{sub c{sub 0}}(r,z{sub 0}) is the inverse Hankel transform of the ratio of the Hankel transforms of BF and Φ. Finally, an uncertainty analysis according to the Guide to the Expression of Uncertainty in Measurement is carried out for 3 different values of k{sub c{sub 0}}(r,z{sub 0}). Calculated and measured OARs agree within the dose/distance-to-agreement criteria of 2%/0.12 mm; while, S{sub t} factors agree within 2%. This procedure supplies an independent method to validate the dosimetric data necessary to feed treatment planning systems for SRS with cones.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal technique of linear accelerator–based stereotactic radiosurgery for tumors adjacent to brainstem

Stereotactic radiosurgery (SRS) is a well-established technique that is replacing whole-brain irradiation in the treatment of intracranial lesions, which leads to better preservation of brain functions, and therefore a better quality of life for the patient. There are several available forms of linear accelerator (LINAC)–based SRS, and the goal of the present study is to identify which of these techniques is best (as evaluated by dosimetric outcomes statistically) when the target is located adjacent to brainstem. We collected the records of 17 patients with lesions close to the brainstem who had previously been treated with single-fraction radiosurgery. In all, 5 different lesion catalogs were collected, and the patients were divided into 2 distance groups—1 consisting of 7 patients with a target-to-brainstem distance of less than 0.5 cm, and the other of 10 patients with a target-to-brainstem distance of ≥ 0.5 and < 1 cm. Comparison was then made among the following 3 types of LINAC-based radiosurgery: dynamic conformal arcs (DCA), intensity-modulated radiosurgery (IMRS), and volumetric modulated arc radiotherapy (VMAT). All techniques included multiple noncoplanar beams or arcs with or without intensity-modulated delivery. The volume of gross tumor volume (GTV) ranged from 0.2 cm{sup 3} to 21.9 cm{sup 3}. Regarding the dose homogeneity index (HI{sub ICRU}) and conformity index (CI{sub ICRU}) were without significant difference between techniques statistically. However, the average CI{sub ICRU} = 1.09 ± 0.56 achieved by VMAT was the best of the 3 techniques. Moreover, notable improvement in gradient index (GI) was observed when VMAT was used (0.74 ± 0.13), and this result was significantly better than those achieved by the 2 other techniques (p < 0.05). For V{sub 4} {sub Gy} of brainstem, both VMAT (2.5%) and IMRS (2.7%) were significantly lower than DCA (4.9%), both at the p < 0.05 level. Regarding V{sub 2} {sub Gy} of normal brain, VMAT plans had attained 6.4 ± 5%; this was significantly better (p < 0.05) than either DCA or IMRS plans, at 9.2 ± 7% and 8.2 ± 6%, respectively. Owing to the multiple arc or beam planning designs of IMRS and VMAT, both of these techniques required higher MU delivery than DCA, with the averages being twice as high (p < 0.05). If linear accelerator is only 1 modality can to establish for SRS treatment. Based on statistical evidence retrospectively, we recommend VMAT as the optimal technique for delivering treatment to tumors adjacent to brainstem.

61 RADIATION PROTECTION AND DOSIMETRY↗

An isothermal forming process with multi-stage variable speed for magnesium component assisted by sensitivity analysis

We have developed a multi-stage variable speed (MSV) isothermal forming process based on strain rate sensitivity (SRS) analysis, and successfully produced a large size of rib-web component of magnesium alloy from a cylindrical billet. The obtained rib-web component has been processed into parts for mechanical properties examination and the examination results met the standard of being safely used in aircrafts. The process parameters of the forming technology and microstructure change were explicitly linked by the SRS coefficient. The finite element (FE) simulation and SRS distribution were implemented to identify the relationship among process parameters, shaping characteristics, and microstructure development. The MSV speed process was employed for reducing the forming load, refining grain sizes and increasing the strength of the component. With the selected process parameters the maximum forming load was reduced to be less than 20 MN, which is 55.3% lower than that used in the same process with the initial constant speed unchanged. Fine dynamic recrystallization (DRX) were observed from all parts of the forged cover plate including the convex, ribs, and web region. It was also found that higher strain resulted in more uniform distribution of fine ß-Mg17Al12 precipitates and larger DRX volume fraction. Importantly the developed isothermal forming process with severe plastic deformation can be applied for obtaining grain refinement so improving the mechanical properties of Mg products.

Magnesium alloy, Isothermal forming, Multi-stage v↗

Stimulated Raman Scattering Microscopy: Real-Time In-Situ Physical and Chemical Characterization of Reverse Osmosis Desalination Membrane Scaling

We introduce a stimulated Raman scattering (SRS) methodology designed for rapid, real-time, and in situ monitoring of RO membrane scaling adapted for bench-scale desalination flow cells. The methodology can provide new insights into membrane scaling dynamics by offering time-resolved reflection imaging of inorganic crystal growth, coupled with chemical identification from Raman spectral data. These capabilities allow for direct local measurement of the membrane surface area covered by different scalants as well as an approximation of the scalant volume using three-dimensional, integrated Raman intensity. The 2D and 3D SRS results obtained from CaSO 4 scaling experiments are compared to and are in reasonable agreement with those provided by confocal microscopy. The real-time physical and chemical characterization capabilities presented here could be extended to study combinations of inorganic, organic, and biological fouling. Overall, the SRS methodology represents an advancement in real-time sensing of membrane fouling that offers the potential for improved operation, lower cost, and more resilient RO membrane systems for sustainable water management.

42 ENGINEERING↗

Impact of natural organic matter on plutonium vadose zone migration from an NH4Pu(V)O2CO3(s) source

Large amounts of plutonium produced at the Savannah River Site (SRS) in the latter half of the last century led to the release of plutonium to the subsurface. Low-level waste containing plutonium has also been disposed of in the SRS vadose zone. The mobility and risk posed by these plutonium sources is not well understood, in part, because of unknown interactions of the various mobile plutonium species with natural organic matter (NOM). This study investigated the influence of NOM on the behavior of plutonium(V) in the vadose zone through a combination of field lysimeter and laboratory studies. Well-defined solid sources of NH4PuVO2CO3(s) placed in 5-L lysimeters containing vadose zone soils NOM-amended or unamended were exposed to natural SRS meteorological conditions for three years. These lysimeters were removed from the field and analyzed using wet chemistry methods and X-ray absorption spectroscopy (XAS). Plutonium desorption from soils recovered from the lysimeters and laboratory batch sorption experiments using Pu-free soils both indicated that surface mediated reduction of Pu(V) to Pu(IV) was influencing Pu sorption behavior. For both lysimeters (amended and unamended with NOM), Pu migrated slowly through the lysimeter core, with > 95% of the Pu remaining within 2 cm of the source. However, without the NOM amendments, Pu was transported significantly farther than in the presence of NOM. Thus, the presence of NOM appeared to decrease the mobility. Working hypotheses to explain this behavior are that 1) formation of ternary surface-NOM-Pu complexes enhanced Pu sorption affinity causing less mobility and/or 2) formation of these ternary surface-NOM-Pu complexes prevented reoxidaiton of Pu(IV) to more mobile Pu(V) in the pore water.

plutonium, organic matter↗

Suppression of stimulated Raman scattering of a laser in a rippled density plasma

The effect of a stationary electron density ripple on stimulated Raman scattering (SRS) of a laser in a plasma is studied. The density ripple couples with the primary Langmuir wave, generated in the Raman process, to produce a secondary Langmuir wave of larger wave number that is strongly Landau damped on the electrons. As a consequence, the growth rate of the Raman process is suppressed. In a special case of density ripple produced by two counterpropagating lasers of intensity {approx}10{sup 15} W/cm{sup 2} at 1 {mu}m wavelength in a 6% critical density plasma of 1 keV temperature, the reduction in growth rate is substantial. The effect of density ripple wavelength on SRS is studied at different plasma temperatures. Up to {approx}70% suppression in SRS is observed for different plasma temperatures at different ripple wavelengths. However, for higher temperatures we also get {approx}10% of suppression for the other ripple wavelength values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of the stimulated Raman scattering instability in two-dimensional particle-in-cell simulations

In the following work, we analyze one-dimensional (1D) and two-dimensional (2D) full particle-in-cell simulations of stimulated Raman scattering (SRS) and study the evolution of Langmuir waves (LWs) in the kinetic regime. It is found that SRS reflectivity becomes random due to a nonlinear frequency shift and that the transverse modulations of LWs are induced by (i) the Weibel instability due to the current of trapped particles and (ii) the trapped particle modulational instability (TPMI) [H. Rose, Phys. Plasmas 12, 12318 (2005)]. Comparisons between 1D and 2D cases indicate that the nonlinear frequency shift is responsible for the first saturation of SRS. After this transient interval of first saturation, 2D effects become important: a strong side-scattering of the light, caused by these transverse modulations of the LW and the presence of a nonlinear frequency shift, is observed together with a strong transverse diffusion. This leads to an increase of the Landau damping rate of the LW, contributing to the limiting of Raman backscattering. A model is developed that reproduces the transverse evolution of the magnetic field due to trapped particles. Based on a simple 1D hydrodynamic model, the growth rate for the Weibel instability of the transverse electrostatic mode and magnetic field is estimated and found to be close to the TPMI growth rate [H. Rose et al., Phys. Plasmas 15, 042311 (2008)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of laser-induced plasma in supercritical water and vibrational spectroscopic study of accompanying stimulated Raman scattering

We have formed a laser-induced plasma (LIP) in supercritical water (SCW) and studied associated molecular vibrations using spectroscopic methods. The accompanying forward and backward stimulated Raman scattering (SRS) of water molecules showed anisotropic behavior at supercritical conditions (>647 K and >22.1 MPa). The Raman shift of the backward SRS indicated that attractive interactions between water molecules and excess electrons generated by the LIP were dominant in the SCW. The backward SRS spectrum provided a microscopic view of the hydration environment around an excess electron, which is useful for controlling electron-driven chemical reactions and materials processing in SCW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗