Mapping alteration in the Goldfield Mining District, Nevada, with the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Analysis of the data acquired by the Airborne Visible/IR Imaging Spectrometer over the Goldfield Mining District, Nevada, demonstrates the unique capabilities of high resolution imaging spectrometers for alteration mapping and identification of mineralogy. The study focuses on the 2-2.45 micron window, as alteration minerals of interest have their distinctive spectral reflectance features in this region. An attempt was made to map the spatial distribution of the individual minerals and produce a mixture maps showing their relative abundance on a pixel-by-pixel basis, focussing on selected subareas. Software and SNR performances limited success in detailed mapping.

Carrere, Veronique↗

Fiber-coupled high resolution infrared array spectrometer for the Kuiper Airborne Observatory

A novel cryogenic grating spectrometer (FCAS) is being designed for observations of volatiles in cometary and planetary atmospheres, and in newly forming planetary systems. The instrument features two-dimensional detector arrays coupled to a high-dispersion echelle by infrared fibers, and will achieve a spectral resolving power of about 40,000. The primary observational platform for this instrument will be the Kuiper Airborne Observatory, but it will also be configured for use at ground-based observatories. Initially, the spectrometer will use a 58 x 62, 1- to 5-micron InSb array. Larger-format IR arrays and arrays of different composition, will later be incorporated as they become available. The instrument will be used in two modes. The first uses a large format IR array in the spectral image plane for the customary one-dimensional spectral-one-dimensional spatial coverage. In the second mode, a massive, coherent bundle of infrared transmitting ZrF4 fibers will be installed after the dispersive element, to reformat the two-dimensional array into an elongated one-dimensional array for wide spectral coverage, allowing multiple lines to be measured in a single integration with high sensitivity. The overall instrument design is discussed, and the system sensitivity is estimated.

Glenar, D. A.↗

Miniaturized, 9-12 micron heterodyne spectrometer with space qualifiable design features

A demonstration-prototype CO2-laser heterodyne spectrometer operating at 9-12 microns and suitable for long-term space missions is described and illustrated with extensive diagrams, drawings, photographs, and graphs of test performance data. The spectrometer has total volume 0.63 cu m, mass 30 kg, and power requirement 60-70 W, compatible with miniature-class Space Shuttle experiment payload specifications. It comprises three modules: (1) an optical front end with reflecting optics, a 2-GHz BW HgCdTe photomixer, and a 0-2-GHz 40-dB RF preamplifier; (2) a local oscillator with an RF-excited waveguide CO2 laser, a 75-percent-efficiency RF amplifier, a stepper-driven grating mode selector, and an etalon stabilized for over 30,000 h of use; and (3) an RF-filter-bank spectral-line receiver with a 25-MHz RF channel, 1.6-GHz IF spectral coverage, onboard instrument control, a serial link to the host computer, and highly integrated design.

Glenar, D. A.↗

The Moderate Resolution Imaging Spectrometer-tilt (MODIS-T)

There will be several state-of-the-art spectrometers in operation on the NASA Polar Oribting Platform (NPOP-1) as part of the Earth Observing System. The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir-viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The MODIS-T instrument is required to cover the wavelength range of 400 to 880 nm in approximately 15 steps, have less than 2.3 percent instrument-induced polarization, be calibrated to an absolute radiometric accuracy of at least 5 percent over the full dynamic range of the instrument, have a 1.1 kilometer square instantaneous field of view at nadir, and be capable of + or - 50-deg along-track tilt.

Magner, Thomas J.↗

Tunable far infrared laser spectrometers

The state of the art in far infrared (FIR) spectroscopy is reviewed. The development of tunable, coherent FIR radiation sources is discussed. Applications of tunable FIR laser spectrometers for measurement of rotational spectra and dipole moments of molecular ions and free radicals, vibration-rotation-tunneling spectra of weakly bound complexes, and vibration-rotation spectra of linear carbon clusters are presented. A detailed description of the Berkeley tunable FIR laser spectrometers is presented.

Blake, G. A.↗

The Voyager ultraviolet spectrometers - Astrophysical observations from the outer solar system

The main characteristics of the ultraviolet spectrometers on board the Voyager 1 and 2 spacecraft and the astrophysical experiments being currently conducted are reviewed. The spectrometers are sensitive over the wavelength range of 50 to 170 nm, which is observable only from space. The experiments include a program of stellar and nonstellar observations, monitoring of the ultraviolet flux from the sun, and studies of the interstellar wind entering the solar system. Several specific observations of particular interest are discussed.

Linick, S. H.↗

Combined Backscatter Moessbauer Spectrometer and X Ray Fluorescence analyzer (BaMS/XRF) for planetary surface materials

A backscatter Moessbauer spectrometer (BaMS) with included x ray fluorescence (XRF) capability for the Mars Environment Survey (MESUR) Mission, which has been proposed by NASA for 1998, is being developed. The instrument will also be suitable for other planetary missions such as those to the Moon, asteroids, and other solid solar-system objects. The BaMS would be unique for MESUR in providing information about iron mineralogy in rocks, clays, and other surface materials, including relative proportions of iron-bearing minerals. It requires no sample preparation and can identify all the normal oxidation states of iron (3+, 2+, 0). Thus, BaMS is diagnostic for weathering and other soil-forming processes. Backscatter design allows the addition of XRF elemental analysis with little or no modification. The BaMS/XRF instrument complements the thermal analyzer with evolved gas analyzer (TA-EGA) and the alpha-proton x-ray spectrometer (APXS) proposed (along with BaMS) for geochemical analysis on MESUR.

Agresti, D. G.↗

The rotating spectrometer: Biotechnology for cell separations

An instrument for biochemical studies, called the rotating spectrometer, separates previously inseparable cell cultures. The rotating spectrometer is intended for use in pharmacological studies which require fractional splitting of heterogeneous cell cultures based on cell morphology and swimming behavior. As a method to separate and concentrate cells in free solution, the rotating method requires active organism participation and can effectively split the large class of organisms known to form spontaneous patterns. Examples include the biochemical star, an organism called Tetrahymena pyriformis. Following focusing in a rotating frame, the separation is accomplished using different radial dependencies of concentrated algal and protozoan species. The focusing itself appears as concentric rings and arises from the coupling between swimming direction and Coriolis forces. A dense cut is taken at varying radii, and extraction is replenished at an inlet. Unlike standard separation and concentrating techniques such as filtration or centrifugation, the instrument is able to separate motile from immotile fractions. For a single pass, typical split efficiencies can reach 200 to 300 percent compared to the inlet concentration.

Noever, David A.↗

Sensitivity of LDEF foil analyses using ultra-low background germanium versus large NaI(T1) multidimensional spectrometers

Cobalt samples were analyzed for cosmic ray induced Co-60 with both an ultralow background germanium gamma ray spectrometer and with a large NaI(T1) multidimensional spectrometer using electronic anticoincidence shielding. Aluminum samples were analyzed for Na-22. The results are presented along with the relative sensitivities and precision afforded by the two methods.

Reeves, James H.↗

A spectrometer for studies of diffuse emission in the 900-1200 A band

A rich assortment of emission processes from the interstellar medium should generate complex spectra in the 900-1200-A regime. However, the detection of these lines is a difficult instrumental task since geocoronal and interplanetary airglow lines form an unwanted background requiring rejection by at least six orders of magnitudes. The design and performance are described of an imaging spectrometer. This spectrometer is designed for 2.5-A spectral resolution, low instrumental scattering, and a high sensitivity to diffuse emission.

Edelstein, J.↗

Improved Limb Atmospheric Spectrometer (ILAS) for polar stratospheric trace gas measurements

The Improved Limb Atmospheric Spectrometer (ILAS) is a grating spectrometer designed to measure vertical profiles of high latitude stratospheric constituents in a solar occultation mode. ILAS measurement gases are ozone (03), methane (CH4), nitrous oxide (N2O), nitric acid (HNO3), water vapor (H2O), nitrogen dioxide (NO2), and CFC-11 using an IR channel. Temperature, pressure, and aerosol are also measured using a visible channel. The IR channel consists of 44 detector elements which cover the spectral range 6.2 to 11.8 microns, and the visible channel is composed of 1024 pixels that cover 753 to 784 nm. ILAS will be installed on the Advanced Earth Observing Satellite (ADEOS) which will be launched in 1995. Instrument design data are outlined.

Yokota, Tatsuya↗

The application of high spectral and spatial resolution imaging spectrometers for locating downed aircraft

The utility of high-resolution imaging spectrometer data is examined as an aid in locating downed aircraft by using a unique spectral signature while not requiring the extremely high spatial resolution needed to identify an aircraft by shape. Ground spectral measurements of several airplane wings, overflight spectral measurements of aircraft scenes, and the rationale for the chosen spectral signature are presented. It is concluded that imaging spectrometers which can detect and spatially locate a narrow-band spectral signature filling only a few pixels appear to have a utility for search and rescue aircraft or satellite systems as a aid in locating small downed aircraft. This spectral feature would have to be added to the surface coatings applied to aircraft. Proposed for use as such a spectral signature is a significant negative reflectance slope, in the 520 to 580 nm interval.

Gatlin, James A.↗

The AXAF CCD imaging spectrometer

The current status of the instrument design and the status of the CCDs being fabricated for the AXAF CCD Imaging Spectrometer (ACIS) are summarized. The instrument consists of an image recording array of CCDs and a linear arrangement of CCDs to record the spectra formed by the objective grating spectrometer. Both arrays employ CCDs with pixel dimensions which correspond to about 0.5 arcsec samples of the image. The CCDs provide moderate spectral resolution and good detection efficiency over the energy range 0.5 to 10 keV. Spectral resolution of 200 or more is achievable using the objective grating with the grating array. Radiation damage effects are shown to degrade the energy resolution of CCDs. Specially designed CCD pixel architecture is employed together with shielding and low temperature operation to slow the effects of radiation damage.

Garmire, G. P.↗

The Galileo and Pioneer Venus ultraviolet spectrometer experiments - Solar Lyman-alpha latitude variation at solar maximum from interplanetary Lyman-alpha observations

Solar Ly-alpha latitude variation at solar maximum is examined on the basis of interplanetary Ly-alpha observations made during the Galileo and Pioneer Venus UV spectrometer experiments. A comparison is made of the latitude variation of the interplanetary (IP) Ly-alpha signal in 1986 at solar minimum from Pioneer Venus and in 1990 at solar maximum from Galileo. The Galileo EUV spectrometer shows that a large enhancement of the IP Ly-alpha emission occurred over the intervening four years near the solar equator. An IP Ly-alpha model is developed which considers the latitude variation of the solar Ly-alpha flux. The model fit to the data shows a 25-percent decrease of the full disk solar Ly-alpha flux from solar equator to solar pole in 1990. A detailed study of the Galileo IP Ly-alpha observations on day-of-year 190, 193, 197, and 200 in 1990 reveals that large variations occur in response to the 27-d solar variation. Analysis of these data shows that a maximum variation of 20 percent can be expected in the IP Ly-alpha upwind intensity over this 27-d period.

Pryor, W. R.↗

The Composite Infrared Spectrometer

The Composite Infrared Spectrometer (CIRS) is a remote sensing instrument to be flown on the Cassini orbiter. It contains two Fourier transform spectrometers covering wavelengths of 7-1000 microns. The instrument is expected to have higher spectral resolution, smaller field of view, and better signal-to-noise performance than its counterpart, IRIS, on the Voyager missions. These improvements allow the study of the variability of the composition and temperature of the atmospheres of both Saturn and Titan with latitude, longitude and height, as well as allowing the possibility of discovery of previously undetected chemical species in these atmospheres. The long wavelengths accessible to CIRS allow sounding deeper into both atmospheres than was possible with IRIS.

Calcutt, Simon↗

Light-trap design using multiple reflections and solid-angle attenuation - Application to a spaceborne electron spectrometer

The design and performance of a new light trap for a spaceborne electron spectrometer are described. The light trap has a measured photon-rejection ratio of 2 x 10 exp -11, allowing only one in 5 x 10 exp 10 incident photons to reach the sensitive area of the instrument. This rejection is more than sufficient because the ambient UV in earth orbit requires a rejection no better than 10 exp -8 to maintain the photon interference to less than 10 count/s. The light trap uses triple reflections to keep most of the light passing through the entrance slit away from the sensitive area of the spectrometer. It is shown that the average reflectance of all the internal surfaces must be less than 0.006, which is consistent with the data on the black coating applied to all surfaces. The analysis makes it possible to compare the photon contributions of each of the internal reflecting areas and to estimate the effective scattering width of the metallic electrode edge.

Herrero, Federico A.↗

Compact Raman Spectrometers Would Detect Hydrogen

Compact Raman spectrometers developed to measure concentrations of hydrogen as low as hundreds of parts per million in air, nitrogen, or other carrier gases. Advantages include speed, dynamic range, and ease of calibration. Design concept incorporates Raman-scattering apparatus into compact instrument of hydrogen leaking into stream of gas or into gas enclosed in small space. Should hydrogen-fueled cars and trucks come into widespread use, instruments used to detect leaks from vehicles and supply equipment, to help prevent explosions. Similar spectrometers developed to detect other gases emitting characteristic Raman spectra.

Helms, William R.↗