Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safeguards Technology Development Program 1st Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Safeguards Technology Development Program 3rd Quarter FY 2018 Report

LLNL will evaluate the performance of a stilbene-based scintillation detector array for IAEA neutron multiplicity counting (NMC) applications. This effort will combine newly developed modeling methodologies and recently acquired high-efficiency stilbene detector units to quantitatively compare the prototype system performance with the conventional He-3 counters and liquid scintillator alternatives.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Memorandum of Understanding for the 2010 Meson Test Beam Program T-995: Muon Detector / Tail Catcher R&D

This is a memorandum of understanding between the Fermi National Accelerator Laboratory and experimenters from Fermilab, Indiana University, Northern Illinois University, University of Notre Dame, Wayne State University, INFN (Trieste / Udine, Roma I, Padova, Ferrara) who have committed to participate in beam tests to be carried out during the 2010 MTBF pro gram. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties. However, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate amendments to this memorandum which will reflect such required adjustments. The test objectives are to continue the development of extruded scintillator-based muon counters begun in T-956 with emphasis on the use of Si Pixelated Photon Detectors (PPDs). The R&D program outlined here continues the T-956 studies using particle beams to test long strip counters, up to 6m, and new prototype TB4 electronics developed at Fermilab which the experimenters expect will lead to the assembly of future large-scale integrated systems that may be the subject for a future proposal. For the purpose of this work, T-995 will require limited space and resources which may be compatible with other users' equipment in the testing area. The T-995 experimenters may not always require control of the beam. The T-995 experimenters will use some of the same apparatus that is to be used by the experimenters who will study total absorption dual readout calorimetry at MTest (experiment T-1004). The T-995 and T-I004 experimenters both use newly designed Fermilab electronics to digitize the shape of the PPD pulse corresponding to the scintillator output. Both projects will share most of the data acquisition software and typically they will share the same beam instrumentation (beam defining counters and coincidence circuits). Both sets of experimenters will share some of the same counting house logic and analysis software for on-line data analysis. Some of the T-995 and T-I004 manpower available to the two projects will work on both projects although many of the studies will not run concurrently.

43 PARTICLE ACCELERATORS↗

Direct thermal neutron detection by the 2D semiconductor 6 LiInP 2 Se 6

Highly efficient neutron detectors are critical in many sectors, including national security, medicine, crystallography and astronomy. The main neutron detection technologies currently used involve 3 He-gas-filled proportional counters and light scintillators for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as 6 Li, 10 B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP 2 Se 6 and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an 241 Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP 2 Se 6 detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using 6 Li-enriched (95 per cent) LiInP 2 Se 6 detectors with full-peak resolution. Here, we anticipate that these results will spark interest in this field and enable the replacement of 3 He counters by semiconductor-based neutron detectors.

36 MATERIALS SCIENCE↗

Radiation Characteristics of the FN-II Dense Plasma Focus Device

The Fuego Nuevo II (FN-II) dense plasma focus device is a small machine (4.6 kJ), operating at the Instituto de Ciencias Nucleares, UNAM, in which neutrons, as well as soft and hard X rays have been studied with a number of diagnostics. Neutrons are studied with silver activation counters, and scintillator-photomultiplier detectors, while their angular distribution inside and outside the discharge chamber have been studied with CR-39 plastic track detectors. The soft X rays are studied with a multiple-pin-hole camera and PIN diodes, while the hard X-rays are observed with the scintillator-photomultiplier detectors mentioned above. When a needle is inserted on the inner electrode, a bright spot of hard x-rays can be concentrated, and used for the production of high-contrast radiography. Dosimetric measurements have been made for X-rays crossing a 300 micron aluminum window, through the axis of the machine, showing an average dose of 0.11{+-}0.01 mGy per shot. In contrast, the average dose with a hollow cathode is 0.077{+-}0.006 mGy per shot.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3 He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3 He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron ( 10 B) and enriched lithium ( 6 Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (t g ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10 -24 cm 2 ), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A balloon-borne ionization spectrometer with very large aperture for the detection of high energy cosmic rays

A balloon experiment which was used to determine the chemical composition of very high-energy cosmic rays up to and beyond 100 GeV/nucleon is described. The detector had a geometric factor of 1 sq m sr and a total weight on the balloon of 2100 kg. The apparatus consisted of an ionization spectrometer, spark chambers, and plastic scintillation and Cherenkov counters. It was calibrated at CERN up to 24 GeV/c protons and at DESY up to 7 GeV/c electrons. In October 1972 it was flown successfully on a stratospheric balloon.

Atallah, K.↗

X-ray spectrometer experiment aboard the ISEE-C /Heliocentric/ spacecraft

This experiment is designed to provide continuous coverage of solar flare X-ray bursts and transient cosmic gamma-ray bursts. A proportional counter and a scintillation detector together cover the energy range from 5 to 228 keV with good sensitivity, large dynamic range, and high temporal resolution. This experiment provides data storage capability and good absolute timing so that in conjunction with similar experiments on other spacecraft, accurate source locations can be obtained for cosmic gamma-ray bursts.

Anderson, K. A.↗

Comparative energy spectra of z equals 3-8 nuclei in the energy range 200 MeV/nuc to 3 GeV/nuc

The energy spectra and charge ratios of Li, Be, B, C, N, and O nuclei in the energy range 200 MeV/nuc to 3 GeV/nuc are examined with measurements obtained during a 50 hour balloon flight in 1977 from a telescope containing several scintillation and Cerenkov counters. The ratios Li/C, Be/C, and B/C are compared with predictions based on the leaky box interstellar propagation model showing that the ratios steadily increase in the apparent interstellar matter path length down to energies of about 400 to 600 MeV/nuc, where it is between 6.5 and 7.5 g/square cm. The effects of solar modulation upon the ratios are considered for energies less than about 1 GeV/nuc as well as for a modulation parameters of phi not less than 400 MV. By examining the ratios Li/Be, Li/B, and Be/B as a function of energy, it is shown that the Li/Be ratio is most sensitive to the solar modulation effects, and that the observed changes in this ratio with energy can be explained by a relatively large modulation consistent with a phi equal to 400 MV in 1977.

Webber, W. R.↗

High resolution determination of elemental abundances for Z equals 8-28 at 1.2-2.4 GeV/n

Results are reported from a series of high-altitude balloon flights of a combination scintillator-double Cerenkov counter telescope to obtain abundances for the nuclei oxygen through nickel corrected to the top of the atmosphere. Over this charge range unambiguous element separation, including the rare element cobalt, has been achieved. Final results are presented of an analysis giving relative abundances over this charge and energy range and compared with other recent experiments.

Dwyer, R.↗

11-year cycle solar modulation of cosmic ray intensity inferred from C-14 content variation in dated tree rings

A liquid scintillation-photomultiplier tube counter system was used to measure the Delta-C-14 values of 60 tree rings, dating from 1866 to 1925, that were taken from a white spruce grown in Canada at 68 deg N, 130 deg W. A 10-percent variation is found which is anticorrelated with sunspot numbers, although the amplitude of the variation is 2-3 times higher than expected in trees grown at lower latitudes. A large dip in the data at about 1875 suggests an anomalously large modulation of cosmic ray intensity during the 1867-1878 AD solar cycle, which was the most active of the 19th century.

Fan, C. Y.↗

Cosmic-ray elemental abundances from 1 to 10 GeV per amu for boron through nickel

The relative abundances of cosmic-ray nuclei in the charge range boron through nickel over the energy range 1-10 GeV per amu were measured with a balloon-borne detector. The instrument consists of a scintillation and Cerenkov counter telescope with a multiwire proportional chamber hodoscope and has been flown in four high-altitude balloon flights. Good charge resolution (sigma = 0.2 charge units at iron) and high statistical accuracy have been achieved. These data are used to derive the energy dependence of the leakage path length using the leaky box model of propagation and confinement in the galaxy. This energy dependence is found to be best fit by lambda = E(tot) exp -n, where n = 0.49 + or - 0.06 over 1-10 GeV per amu. Relative abundances at the source are consistent with an energy-independent composition.

Dwyer, Robert↗

Neutron Stars and Black Holes Seen with the Rossi X-Ray Timing Explorer (RXTE)

Astrophysical X-rays bring information about location, energy, time, and polarization. X-rays from compact objects were seen in the first explorations to vary in time. Eclipses and pulsations have simple explanations that identified the importance of X-ray binaries and magnetic neutron stars in the first decade of X-ray astronomy. The dynamics of accretion onto stellar and supermassive black holes and onto neutron stars with relatively low magnetic fields shows up as more complex variations, quasi-periodic oscillations, noise with characteristic frequency spectra, broad-band changes in the energy spectra. To study these variations, RXTE instruments needed to have large area and operational flexibility to find transient activity and observe when it was present. Proportional counters and Phoswich scintillators provided it in a modest mission that has made textbook level contributions to understanding of compact objects. The first seen, and the brightest known, X-ray binary, Sco X-1 is one of a class of neutron stars with low mass companions. Before RXTE, none of these had been seen to show pulsations, though they were hypothesized to be the precursors of radio pulsars with millisecond periods and low magnetic fields. RXTE's large area led to identifying coherent millisecond pulsars in a subset which are relatively faint transients. It also led to identifying short episodes of pulsation during thermonuclear bursts, in sources where a steady signal is not seen. The X-ray stage verifies the evolution that produces millisecond radio pulsars.Masses and radii of neutron stars are being determined by various techniques, constraining the equation of state of matter at nuclear densities. Accretion should lead to a range of neutron star masses. An early stage of superstrong magnetic field neutron stars is now known to produce X-ray and gamma-ray bursts in crust quakes and magnetic field reconnection releases of energy. Soft Gamma Repeaters, Anomolous X-ray Pulsars, and high magnetic field rotation-powered pulsars are all now called magnetars, because they have pulse periods indicating they are slowing down as they would with magnetic dipole radiation for a surface field above 5x1013 gauss. The accretion disk has been connected to the launching of radio jets from black holes, and even from neutron stars. Estimates of the angular momenta of black holes are being made from different approaches, modelling a high frequency oscillation that may be related to how close the inner part of the accretion disk is to the black hole, modelling the continua spectra of the X-ray emission, and modeling the emission of red-shifted iron that may be emitted from the accretion disk. These investigations require early discovery of the black hole transient with the All Sky Monitor on RXTE or other monitoring information, frequent extended observations, and coordinated observations with missions that give higher energy resolution, or radio and infrared information.

Swank, Jean↗

The Energetic Trans-Iron Nuclei Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)" which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.3 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of ~20 m2sr. Measurements made in space for a period of 3 years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized heavy elements (Pu and Cm), what the age of that component is, and test the model of the OB association origin of galactic cosmic rays. Additionally, it will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas.

Binns, W. R.↗