Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

On the design of random metasurface based devices

Metasurfaces are generally designed by placing scatterers in periodic or pseudo-periodic grids. We propose and discuss design rules for functional metasurfaces with randomly placed anisotropic elements that randomly sample a well-defined phase function. By analyzing the focusing performance of random metasurface lenses as a function of their density and the density of the phase-maps used to design them, we find that the performance of 1D metasurfaces is mostly governed by their density while 2D metasurfaces strongly depend on both the density and the near-field coupling configuration of the surface. The proposed approach is used to design all-polarization random metalenses at near infrared frequencies. Challenges, as well as opportunities of random metasurfaces compared to periodic ones are discussed. Our results pave the way to new approaches in the design of nanophotonic structures and devices from lenses to solar energy concentrators.

14 SOLAR ENERGY↗

Hyperdimensional scanning transmission electron microscopy and examinations and related systems, methods, and devices

A material identification system includes one or more data interfaces configured to receive first sensor data generated by a first sensor responsive to a material sample, and receive second sensor data generated by a second sensor responsive to the material sample. The material identification system also includes one or more processors configured to generate a set of predictions of an identification of the material sample and a corresponding set of certainty information.

Aguiar, Jeffery A.↗

Measuring Concentrations of Particulate 140 La in the Air

Air sampling systems were deployed to measure the concentration of radioactive material in the air during the Full-Scale Radiological Dispersal Device experiments. The air samplers were positioned 100-600 meters downwind of the release point. The filters were collected immediately and analyzed in the field. Quantities for total activity collected on the air filters are reported along with additional information to compute the average or integrated air concentrations.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-209-04: 3D Light Sheet Luminescence Imaging with Cherenkov Radiation

Purpose: To recover a three-dimensional density distribution of luminescent molecular probes located several centimeters deep within a highly scattering tissue. Methods: We developed a novel sheet beam Cherenkov-excited luminescence scanned imaging (CELSI) methodology. The sample was irradiated by a horizontally oriented, vertically scanned 6 MV X-ray sheet beam (200mm × 5mm, 0.2mm vertical step) from a radiotherapy linear accelerator. The resulting Cherenkov light emission – and thus luminescent probe excitation – occurred exclusively along the irradiation plane due to a short diffusion path of secondary particles and Cherenkov photons. Cherenkov-excited luminescence was detected orthogonally to the sheet beam by gated, intensified charge coupled device camera. Analogously to light sheet microscopy, a series of luminescence images was taken for varied axial positions (depths) of the Cherenkov light sheet in sample. Knowledge of the excitation plane position allowed a 3D image stack deconvolution and depth-variant attenuation correction. The 3D image post-processing yielded a true spatial density distribution of luminescent molecules in highly scattering tissue. Results: We recovered a three-dimensional shape and position of 400 µL lesion-mimicking phantom tubes containing 25 µM solution of PtG4 molecular probe from 3 centimeter deep tissue-like media. The high sensitivity of CELSI also allowed resolving 100 micron capillaries of test solution. Functional information of partial oxygen pressure at the site of PtG4 molecular probe was recovered from luminescence lifetime CELSI. Finally, in-vivo sheet beam CELSI localized milimeter-sized PtG4-labelled tumor phantoms in multiple biological objects (hairless mice) from single scan. Conclusion: Presented sheet beam CELSI technique greatly extended the useful depth range of luminescence molecular imaging. More importantly, the light sheet microscopy approach was successfully adapted to CELSI, providing means to recover a completely attenuation-corrected 3D image of luminescent probe distribution. Gated CELSI acquisition yielded functional information of a spatially resolved oxygen concentration map of deep lying targets. This work was supported by NIH research grant R01CA109558 and R21EB017559, as well as by Pilot Grant Funds from the Norris Cotton Cancer Center.

60 APPLIED LIFE SCIENCES↗

Sensitivity Enhancement in Photoconductive Light Field Sampling

Abstract The emerging field of lightwave electronics is driving optoelectronic information processing beyond current classical limitations and has the potential to eventually reach petahertz frequencies. One of the major obstacles in reaching not only higher switching frequencies but also higher repetition rates with low‐power light sources is the efficiency of related devices. A device is presented based on a multilayered material that shows a 13‐fold enhancement in terms of converting light to electric current compared to bulk solids. Furthermore, the device exhibits an almost flat intensity response within its working range. The outstanding properties of engineered multilayered devices promise to push technology for lightwave electronics applications.

47 OTHER INSTRUMENTATION↗

Electrical suppression of all nonradiative recombination pathways in monolayer semiconductors

Defects in conventional semiconductors substantially lower the photoluminescence (PL) quantum yield (QY), a key metric of optoelectronic performance that directly dictates the maximum device efficiency. Here, two-dimensional transition-metal dichalcogenides (TMDCs), such as monolayer MoS 2 , often exhibit low PL QY for as-processed samples, which has typically been attributed to a large native defect density. We show that the PL QY of as-processed MoS 2 and WS 2 monolayers reaches near-unity when they are made intrinsic through electrostatic doping, without any chemical passivation. Surprisingly, neutral exciton recombination is entirely radiative even in the presence of a high native defect density. This finding enables TMDC monolayers for optoelectronic device applications as the stringent requirement of low defect density is eased.

36 MATERIALS SCIENCE↗

Compact electrically detected magnetic resonance setup

Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

36 MATERIALS SCIENCE↗

Microchannel gel electrophoretic separation systems and methods for preparing and using

A micro-analytical platform for performing electrophoresis-based immunoassays was developed by integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device. The microfluidic immunoassays are performed by gel electrophoretic separation and quantifying analyte concentration based upon conventional polyacrylamide gel electrophoresis (PAGE). To retain biological activity of proteins and maintain intact immune complexes, native PAGE conditions were employed. Both direct (non-competitive) and competitive immunoassay formats are demonstrated in microchips for detecting toxins and biomarkers (cytokines, c-reactive protein) in bodily fluids (serum, saliva, oral fluids). Further, a description of gradient gels fabrication is included, in an effort to describe methods we have developed for further optimization of on-chip PAGE immunoassays. The described chip-based PAGE immunoassay method enables immunoassays that are fast (minutes) and require very small amounts of sample (less than a few microliters). Use of microfabricated chips as a platform enables integration, parallel assays, automation and development of portable devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital Autoradiography as a novel complementary technique for the investigation of radioactive contamination in nuclear facilities under dismantlement

The detection (location and quantification) of nuclear facilities to be dismantled possible contamination with low-range particles emitters ({sup 3}H, other low-energy β emitters, a emitters) remains a tedious and expensive task. Indeed, usual remote counters show a too low sensitivity to these non-penetrating radiations, while conventional wipe tests are irrelevant for fixed radioactivity evaluation. The only method to accurately measure activity levels consists in sampling and running advanced laboratory analyses (spectroscopy, liquid scintillation counting, pyrolysis...). Such measurements generally induce sample preparation, waste production (destructive analyses, solvents), nuclear material transportation, long durations, and significant labor mobilization. Therefore, the search for the limitation of their number and cost easily conflicts with the necessity to perform a dense screening for sampling (to maximize the representativeness of the samples), in installations of thousands of square meters (floors, wells, ceilings), plus furniture, pipes, and other wastes. To overcome this contradiction, Digital Autoradiography (D. A.) was re-routed from bio molecular research to radiological mapping of nuclear installations under dismantling and to waste and sample analysis. After in-situ exposure to the possibly-contaminated areas to investigate, commercial reusable radiosensitive phosphor screens (of a few 100 cm{sup 2}) were scanned in the proper laboratory device and sharp quantitative images of the radioactivity could be obtained. The implementation of geostatistical tools in the data processing software enabled the exhaustive characterization of concrete floors at a rate of 2 weeks / 100 m{sup 2}, at lowest costs. Various samples such as drilled cores, or tank and wood pieces, were also successfully evaluated with this method, for decisive results. Thanks to the accurate location of potential contamination spots, this approach ensures relevant and representative sampling for further laboratory analyses and should be inserted in the range of common tools used in dismantling. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Visualization and Manipulation of Tunable Quantum Well State in Semiconducting Nb 2 SiTe 4

We report quantum well states (QWSs) can form at the surface or interfaces of materials with confinement potential. They have broad applications in electronic and optical devices such as high mobility electron transistor, photodetector, and quantum well laser. The properties of the QWSs are usually the key factors for the performance of the devices. However, direct visualization and manipulation of such states are, in general, challenging. In this work, by using angle-resolved photoemission spectroscopy (ARPES) and scanning tunneling microscopy/spectroscopy (STM/STS), we directly probe the QWSs generated on the vacuum interface of a narrow band gap semiconductor Nb 2 SiTe 4 . Interestingly, the position and splitting of QWSs could be easily manipulated via potassium (K) dosage onto the sample surface. Our results suggest Nb 2 SiTe 4 to be an intriguing semiconductor system to study and engineer the QWSs, which has great potential in device applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled removal of hydrogen atoms from H-terminated silicon surfaces

The controlled formation of dangling bond structures on a H-terminated silicon surface is the first step in an atomically precise method of fabrication of silicon quantum electronic devices. An ultrahigh vacuum scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from a Si(100)-2x1:H surface by injecting electrons with the sample held at a positive bias voltage. The authors propose a lithography method that allows the STM to operate under negative bias imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative bias voltage to deliver the required energy for hydrogen removal. The resulting current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM’s feedback control loop. The authors show that the chance of tip-sample crash during the lithography process is reduced by employing this method. They also demonstrate that this approach offers a significant potential for controlled and precise removal of H atoms from a H-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

42 ENGINEERING↗

Quantum advantages for Pauli channel estimation

We show that entangled measurements provide an exponential advantage in sample complexity for Pauli channel estimation, which is both a fundamental problem and a practically important subroutine for benchmarking near-term quantum devices. The specific task we consider is to simultaneously learn all the eigenvalues of an n-qubit Pauli channel to ±ε precision. We give an estimation protocol with an n-qubit ancilla that succeeds with high probability using only O(n/ε 2 ) copies of the Pauli channel, while proving that any ancilla-free protocol (possibly with adaptive control and channel concatenation) would need at least Ω(2 n/3 ) rounds of measurement. We further study the advantages provided by a small number of ancillas. For the case that a k-qubit ancilla (k≤n) is available, we obtain a sample complexity lower bound of Ω(2 (n-k)/3 ) for any nonconcatenating protocol, and a stronger lower bound of Ω(n 2n-k ) for any nonadaptive, nonconcatenating protocol, which is shown to be tight. We also show how to apply the ancilla-assisted estimation protocol to a practical quantum benchmarking task in a noise-resilient and sample-efficient manner, given reasonable noise assumptions. Our results provide a practically interesting example for quantum advantages in learning and also bring insights for quantum benchmarking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sequential Bayesian inference of transition rates in the hidden Markov model for multi-state system degradation

The more easily available system performance data and advances in data analytics have provided us with opportunities to optimize maintenance programs for engineered systems, for example nuclear power plants. One key task in maintenance optimization is to obtain an accurate model for system degradation. Here, in this research, we propose a Bayesian method to address this problem. Noting that systems usually exhibit multiple states and that the actual state of a system usually is not directly observable, in the method we first model the system degradation process and the observation process based on a hidden Markov model. Then we develop a sequential Bayesian inference algorithm based on importance sampling and the forward algorithm to infer the posterior distributions of the transition rates in the hidden Markov model based on available observations. The proposed Bayesian method allows us to take advantage of evidence from multiple sources, and also allows us to perform Bayesian inference sequentially, without the need to use the entire history of observations every time new observations are collected. We demonstrate the proposed method using both synthetic data for a nuclear power plant feedwater pump and realistic data for a nuclear power plant chemistry analytical device.

42 ENGINEERING↗

Theory of Electron Imaging in Small Devices

The research in this program involved theoretical investigations of the transport of charge in graphene and small heterostructure devices. There is an important trend toward imaging electronic systems in real space, with the goal of understanding the specifics of individual samples rather than settling for ensemble and statistical descriptions. For example one of our goals has been the understanding of scanning probe microscopy (SPM) imaging of systems in which the motion of the carriers is restricted to two degrees of freedom, such as in grapheme and the two dimensional electron (and hole) gas (2DEGs and 2DHGs) in GaAs/AlGaAs heterostructures, or when the motion is restricted to one degree of freedom as in nanowires. SPM imaging uses the tip of a movable charged probe to alter the electrons locally, depleting or alternatively increasing the amount of charges in the electron gas just below the tip results in a change to the flow pattern of the charge. The focus of this research was on understanding how the tunable tip affects functional aspects of the device that can be used to understand electronic and transport properties. For instance, scanning over the device while measuring the conductance results in conductance maps, an imaging of the charge transport. This imaging is often semi-direct and requires theory and interpretation to extract all that can be deduced about the underlying physical quantities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Generic Sacrificial Layer for Wide-Range Freestanding Oxides with Modulated Magnetic Anisotropy

Freestanding oxide nanomembranes have promising applications because of their novel electronic states and flexible crystalline structures. Several materials have been developed as sacrificial layers to exfoliate thin films from substrates via wet-etching. However, these materials face great challenges in terms of either complicated crystalline structures or corrosive solutions. Herein, a new sacrificial material, SrCoO 2.5 , is presented, which can be coherently grown with wide-range strains and crystalline orientations and is also soluble in eco-friendly solutions such as acetic acid, vinegar, and even carbonated drinks. With SrCoO 2.5 as the sacrificial layer, high-quality freestanding ferromagnetic SrRuO 3 membranes are achieved from wide-range epitaxial strains and different crystalline orientations. By investigating the evolution of the magnetic properties of these samples, it is discovered that epitaxial strain causes a distinct modification of the magnetic anisotropy of (001) pc -oriented SrRuO 3 samples, while its influence on the (110) pc and (111) pc samples is insignificant. This study not only demonstrates the freestanding SrRuO 3 as a promising material for flexible spintronic devices, but also offers a great opportunity to engineer a wide range of strained and oriented complex oxides for novel freestanding electronics using this newly developed sacrificial material.

36 MATERIALS SCIENCE↗

Detection of a multi–disease biomarker in saliva with graphene field effect transistors

Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes, and Sjogren’s syndrome. However, the lack of a rapid, cheap, accurate, and easy-to-use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label-free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G-FETs) as a transducer and specific RNA aptamers as a probe. The binding of CA1 with aptamers resulted in a positive shift in Dirac voltage V D of the G-FETs, the magnitude of which depended on target concentration. These aptameric G-FET biosensors showed the binding affinity (K D ) of ~2.3 ng/ml (70 pM), which is four orders lower than that reported using a gel shift assay. This lower value of K D enabled us to achieve a detection range (10 pg/ml - 100 ng/ml) which is well in line with the clinically relevant range. These highly sensitive devices allowed us to further prove their clinical relevance by successfully detecting the presence of CA1 in human saliva samples. In conclusion, the utilization of this label-free biosensor could facilitate the early stage identification of various diseases associated with changes in concentration of CAs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

“The development of a through-plane reactive excitation technique for detection of pinholes in membrane-containing MEA sub-assemblies”

As markets for polymer-electrolyte-membrane fuel cells (PEMFC) expand, there continues to be a need for the development and implementation of in-line quality inspection techniques to enable high-volume manufacturing methods for membrane-electrode assemblies (MEAs). These techniques mitigate the potential impact of poor quality on the cost of MEA components by real-time identification of process-induced irregularities, which can result from the manufacturing process or subsequent handling of the material during assembly into a full MEA. A particular type of irregularity known to impact MEA lifetime is loss of membrane integrity, e.g. via a pinhole. In this work, we focus on development of a technique to detect pinholes in membrane-containing MEA sub-assemblies - as opposed to in just the membrane - using a reactive excitation strategy coupled with infrared thermography for detection. A specialized device is introduced and, using various MEA sub-assemblies, is shown to enable detection of pinholes in stationary samples. Multi-physics modeling is utilized to understand and predict the impact of various design and operational parameters of this technique. The feasibility of the technique is demonstrated through both modeling and in-situ results. For example, a detectable (≥1 degree C) thermal response for a membrane pinhole of approximately 90 um in diameter is measured in a fraction of a second. The observed detection time is considered to be appropriate for further exploration of the technique in an in-line configuration.

30 DIRECT ENERGY CONVERSION↗

Facile and low cost oxidative conversion of MoS{sub 2} in α-MoO{sub 3}: Synthesis, characterization and application

This study describes a facile low cost route to synthesize the α-MoO{sub 3} through a conversion of the precursor MoS{sub 2} in oxidant media. The structure and morphology of the α-MoO{sub 3} were studied by high resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. The results show that α-MoO{sub 3} was obtained with reduced size, high purity, strongly-preferred orientation and structural defects, which ensures versatility and multifunctionality to this sample. For the purpose of applications, α-MoO{sub 3} was successfully employed in inverted organic solar cells devices as a possible alternative to the PEDOT:PSS in the hole transportation layer. - Graphical abstract: Synthesis process based on low cost oxidative conversion of MoS{sub 2} in α-MoO{sub 3} Display Omitted - Highlights: • A facile route to obtain α-MoO{sub 3} by refluxing the MoS{sub 2} precursor in oxidant media. • High purity and strongly-preferred orientation. • Belt-shaped material. • Enhanced conversion efficiency (PCE) when compared with conventional PEDOT:PSS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗