Evaluation of Life Testing Schemes
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This presentation describes a battery optimization and trade-off analysis for Li-ion batteries used in EVs and PHEVs to extend their life and/or reduce cost.
Objectives are to enable development and implementation of codes and standards for H{sub 2} containment components: (1) Evaluate data on mechanical properties of materials in H{sub 2} gas - Technical Reference on Hydrogen Compatibility of Materials; (2) Generate new benchmark data on high-priority materials - Pressure vessel steels, stainless steels; and (3) Establish procedures for reliable materials testing - Sustained-load cracking, fatigue crack propagation. Summary of this presentation are: (1) Completed measurement of cracking thresholds (K{sub TH}) for Ni-Cr-Mo pressure vessel steels in high-pressure H{sub 2} gas - K{sub TH} measurements required in ASME Article KD-10 (2) Crack arrest test methods appear to yield non-conservative results compared to crack initiation test methods - (a) Proposal to insert crack initiation test methods in Article KD-10 will be presented to ASME Project Team on Hydrogen Tanks, and (b) Crack initiation methods require test apparatus designed for dynamic loading of specimens in H{sub 2} gas; and (3) Demonstrated ability to measure fatigue crack growth of pressure vessel steels in high-pressure H{sub 2} gas - (a) Fatigue crack growth data in H{sub 2} required in ASME Article KD-10, and (b) Test apparatus is one of few in U.S. or abroad for measuring fatigue crack growth in >100 MPa H{sub 2} gas.
Description and history of the IEC 61215 qualification test, what it accomplishes, and what it does not accomplish that would be useful to the community.
Pseudorapidity gap distributions in proton-proton collisions at {radical}s = 7 {approx} TeV are studied using a minimum bias data sample with an integrated luminosity of 7.1 {micro}b{sup -1}. Cross sections are measured differentially in terms of {Delta}{eta}{sup F}, the larger of the pseudorapidity regions extending to the limits of the ATLAS sensitivity, at {eta} = {+-}4.9, in which no final state particles are produced above a transverse momentum threshold p{sub T}{sup cut}. The measurements span the region 0 < {Delta}{eta}{sup F} < 8 for 200 {approx} MeV < p{sub T}{sup cut} < 800 {approx} MeV. At small {Delta}{eta}{sup F}, the data test the reliability of hadronization models in describing rapidity and transverse momentum fluctuations in final state particle production. The measurements at larger gap sizes are dominated by contributions from the single diffractive dissociation process (pp {yields} Xp), enhanced by double dissociation (pp {yields} XY) where the invariant mass of the lighter of the two dissociation systems satisfies M{sub Y} {approx}< 7 GeV. The resulting cross section is d{sigma}/d{Delta}{eta}{sup F} {approx}1 mb for {Delta}{eta}{sup F} {approx}>3. The large rapidity gap data are used to constrain the value of the Pomeron intercept appropriate to triple Regge models of soft diffraction. The cross section integrated over all gap sizes is compared with other LHC inelastic cross section measurements.
In the nondestructive assay of special nuclear materials, isotopic determination based on the analysis of high-purity Ge high-resolution gamma-ray spectra plays a pivotal role. The isotopic results, which are based on a relative measurement of peak intensities, are used to interpret data acquired using quantitative (mass) nondestructive assay methods. In the case of plutonium measurements, this includes both passive and active neutron techniques, and also calorimetry (heat). Historically, precision estimates on the Pu- isotopic composition have been generated, on a case-by-case basis, by least squares fitting algorithms embedded in the analysis codes, but all other sources of uncertainty have generally been estimated using a top-down approach by item category. A largely neglected consideration is the covariance between the reported abundances and derived quantities – notably Pu-239-effective mass, Pu-240-effective mass and specific thermal power. In this work we study the covariance structure by statistically evaluating repeat spectrum measurements of two known low burn-up heavily filtered Pu items reduced using the spectrum analysis code FRAM 5.2 and alternate standard parameter sets. For routine measurements, however, only a single spectrum from an item will typically be acquired. We therefore discuss how to generate the sought after covariance information from an individual spectrum by spectrum re-sampling, an approach which could be added to provide item specific reports, and compare the two approaches to test its reliability.
Abstract – NFPA 70E mandates that "overcurrent devices shall be maintained in accordance with the manufacturer's instructions or industry consensus standards". At our laboratory this mandate is law, because 10 CFR 851 requires adherence to NFPA 70 and 70E. This begs the question, exactly what are those manufacturer's instructions, and what do the industry consensus standards require? In particular with Molded Case Circuit Breakers (MCCB's), how does one meet these requirements and still apply a balanced approach in a maintenance program when the facilities range from brand new construction to over fifty years old, and where circuit breakers exist that have been made by virtually every major manufacturer? This paper examines the instructions given by the various manufacturers, and examines the standards that exist, along with major guides and white paper recommendations. Both the consistencies and the inconsistencies are examined, recommendations are compared, and a general consensus of recommendations emerges. The various maintenance particulars are examined, from cycling of breakers and thermography to inverse thermal and instantaneous primary injection trip testing. The results of an FMEA (Failure Modes and Effects Analysis) was conducted at our facility; the results of that FMEA and the recommendations of that FMEA for maintenance of MCCB’s are presented. In this paper, we have examined the recommendations of manufacturers, standards, and guides that provide the guidelines for maintenance of molded case circuit breakers. Although many conflicts exist, a consensus of nearly universal recommendations emerges. A balanced approach to maintenance that provides the maximum safety benefit within the bounds of economic feasibility can be developed. We provide a condensation of the existing literature with references, a visual summary of that literature and propose a recommended maintenance approach.
The lab is responding to the coronavirus crisis by imaging disease-related biomolecules, developing standards for reliable coronavirus testing and enabling other essential research.
This chapter reviews the magnitude and spatial distribution of mercury emissions from coal combustion in China. Due to the large quantities of coal burned and the relatively low level of technology, particularly in industry, emissions are high. Emissions were stable at about 200-210 Mg during the period 1995-2000, but because of rapid economic growth starting in 2001, mercury emissions grew quickly to a value of 334 Mg in 2005. The annual average growth rate for the period 1995-2005 was 5.1%. The uncertainty in emission estimates is about {+-}35% (95% confidence intervals). Emissions are concentrated in those provinces with high concentrations of mercury in coal (like Guizhou Province) and provinces in which a lot of coal is burned (like Shanxi Province). Because significant amounts of coal are burned in homes and small industrial facilities, without any kind of emission control at all, emissions of particulate mercury are higher in China than in the developed world; the speciation profile nationwide is: 64% Hg{sup II}, 19% Hg{sup p}, and 17% Hg{sup 0}. In the future, growth in mercury emissions is expected to be limited by the application of FGD for SO{sub 2} control and other advanced technologies. Estimates of emissions are hampered by the lack of comprehensive and reliable emissions testing programs in China.
The National Laboratory of the Rockies (NLR) has a long history of studying the outdoor reliability of electrical connectivity components, including connectors, cables, wire harnesses, and fuses.
No abstract prepared.
Ceramic column grid array (CCGA) packages have been used increasingly in logic and microprocessor functions, telecommunications, flight avionics boards, payload electronics boards, engineering navigational and science cameras, electronic assemblies, and other applications, because of their inherent advantages such as high electrical interconnect density, very good thermal and electrical performance, and compatibility with standard surface-mount technology (SMT) packaging assembly processes. Because these advanced electronic packages tend to have less solder-joint strain-relief than do leaded flat-pack electronic packages, the reliability of CCGA packages in challenging thermal environments is a very important consideration for their short- and long-term use in JPL-NASA space missions. In this study, we assembled daisy chains of polyimide printed wiring boards from CCGA-interconnect packages, inspected the boards nondestructively, and then subjected them to thermal cycling to assess their reliability in thermal environments from +125°C to -40°C±25°C. The test hardware consists of a CCGA 1752 package (CN version). The package was divided into four daisy-chained sections that were electrically monitored for their continuity during thermal cycling. The CCGA 1752 package is roughly 45 mm × 45 mm with a 42-mm × 42-mm array of 80%/20% Pb/Sn columns on a 1.00-mm pitch. The resistance of the daisy-chained CCGA interconnects was continuously monitored during thermal cycling in a gaseous nitrogen environment. Electrical continuity resistance measurements as a function of thermal cycling are reported here; tests to date have shown significant change to an open circuit in daisy-chain resistance as a function of thermal cycling. The change in interconnect resistance becomes increasingly noticeable with increasing number of thermal cycles. This paper describes the experimental thermal-cycling test results of CCGA 1752 package reliability testing under an extremely wide temperature range. The first failure was observed at 1479th thermal cycle. We report the thermal-cycle reliability test data for ~2500 thermal cycles.
This paper presents the results of NREL's Gearbox Reliability Collaborative comparison of dynamometer tests conducted on a 750-kW gearbox to field testing.
This document reports the status of the NEPP Double Data Rate (DDR) Device Reliability effort for FY2013. The task targeted general reliability of > 100 DDR2 devices from Hynix, Samsung, and Micron. Detailed characterization of some devices when stressed by several data storage patterns was studied, targeting ability of the data cells to store the different data patterns without refresh, highlighting the weakest bits. DDR2, Reliability, Data Retention, Temperature Stress, Test System Evaluation, General Reliability, IDD measurements, electronic parts, parts testing, microcircuits
Accurate and reliable prediction of noise emitted from turbofan aircraft engines is an ongoing challenge. For continued progress, it is necessary to assess the performance of the most recent prediction methods in the NASA Aircraft NOise Prediction Program (ANOPP), and to examine the effects of flight condition on fan noise. The assessment is based on an extensive acoustic dataset acquired as part of the Propulsion Airframe Aeroacoustics and Aircraft System Noise (PAA&ASN) Flight Test conducted on a Boeing 787-10 aircraft. Engine operating condition was varied to study the characteristics of fan noise in flight. In a subset of the flight test matrix, the influence of the aft duct acoustic liner was studied by covering the lined area with aluminum tape to simulate a hardwall duct. The combination of test data at different flight conditions, along with rigorous predictions of jet noise, is used in this paper to extract fan noise from the measured total aircraft noise levels. The measured fan noise levels are compared with those predicted using the latest methods for fan source noise, liner attenuation, and PAA effect prediction. Detailed analyses are undertaken to understand agreement between data and various aspects of the prediction models, including spectral shape, directivity, and response to throttle setting. An additional investigation was undertaken to study the effect of aircraft speed on fan noise, as current models do not directly account for this parameter.
Even with radical restriction of range, reliability coefficients from 10 studies gave an average interstudy value of .74, suggesting constancy of reliability over diverse experiments. A value from a new test can help index reliability of tests not previously studied.
The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.
A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.