Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Long-term evaluation of air sensor technology under ambient conditions in Denver, Colorado

Air pollution sensors are quickly proliferating for use in a wide variety of applications, with a low price point that supports use in high-density networks, citizen science, and individual consumer use. This emerging technology motivates the assessment under real-world conditions, including varying pollution levels and environmental conditions. A seven-month, systematic field evaluation of low-cost air pollution sensors was performed in Denver, Colorado, over 2015–2016; the location was chosen to evaluate the sensors in a high-altitude, cool, and dry climate. A suite of particulate matter (PM), ozone (O 3 ), and nitrogen dioxide (NO 2 ) sensors were deployed in triplicate and were collocated with federal equivalent method (FEM) monitors at an urban regulatory site. Sensors were evaluated for their data completeness, correlation with reference monitors, and ability to reproduce trends in pollution data, such as daily concentration values and wind-direction patterns. Most sensors showed high data completeness when dataloggers were functioning properly. The sensors displayed a range of correlations with reference instruments, from poor to very high (e.g., hourly-average PM Pearson correlations with reference measurements varied from 0.01 to 0.86). Some sensors showed a change in response to laboratory audits/testing from before the sampling campaign to afterwards, such as Aeroqual, where the O 3 response slope changed from about 1.2 to 0.6. Some PM sensors measured wind-direction and time-of-day trends similar to those measured by reference monitors, while others did not. This study showed different results for sensor performance than previous studies performed by the U.S. EPA and others, which could be due to different geographic location, meteorology, and aerosol properties. These results imply that continued field testing is necessary to understand emerging air sensing technology.

54 ENVIRONMENTAL SCIENCES↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

Validation of Scale-Derived Ages in Wild Juvenile and Adult Steelhead Using Parental-Based Tagging

Abstract Accurate age information is a critical component in fisheries monitoring, management, and research. The ability to assign accurate ages to fish by using nonlethal structures is vital in calculating cohort productivity for fish species with low abundances and variable life histories. A common nonlethal method to assign ages is by interpretation of patterns in scales. Validation of ages is not easily obtained for free-ranging fishes; however, the development of genetic “tags” has expanded age validation opportunities. In this study, we used parental-based genetic tagging to validate ages determined from scales collected from juvenile and adult steelhead Oncorhynchus mykiss in two streams within the Snake River basin. Juvenile scale ages were in agreement with 93% of the known ages. Adult scale ages were in agreement with 89% of the known ages. Although overall bias in juvenile ages was very low, we saw a slight positive bias in younger fish (young of the year and age 1) and a small negative bias in older juveniles (ages 2–4). A small negative bias in ages of adults was a consequence of errors in freshwater age. The errors observed did not significantly bias age compositions because the 90% confidence intervals about the age proportions based on scales contained the known proportions; therefore, scale analysis is an acceptable method for assigning ages to Snake River steelhead. We discuss the value of validated known-age scales as a reference collection, and as an illustrative use, we constructed a circulus count guide to aid technicians in identifying missing annuli and distinguishing true from false annuli. To demonstrate the use of the circulus guidelines, we reanalyzed samples with age discrepancies, applying the circulus count data and the known age to identify mistakes.

Reinhardt, Leslie↗

Indentation size effect in tungsten: Quantification of geometrically necessary dislocations underneath the indentations using HR-EBSD

Highlights: • Revealed the dislocation structure below nanoindentations via ECCI and HR-EBSD. • Experimentally quantification of GND densities, with higher GND densities at lower depths. • Qualitative validation of the Nix-Gao model on the indentation size effect. - Abstract: During indentation testing of the low defect density crystalline materials, higher hardness values are found at lower indentation depths, which is referred to as an indentation size effect. The depth-dependence of hardness can be described by the Nix-Gao model, which is based on the concept of Geometrically Necessary Dislocations (GNDs). The underlying dislocation mechanism remains, however, unclear and requires independent measurement of GND density below the indentation. In the present work, the depth-dependency of the GND density is quantified underneath the Berkovich indentations in tungsten via high-resolution electron backscatter diffraction. There a higher GND density is found for lower indentation depths, resulting in a higher Taylor hardness for measured GND density.

36 MATERIALS SCIENCE↗

Influence of compensator thickness, field size, and off-axis distance on the effective attenuation coefficient of a cerrobend compensator for intensity-modulated radiation therapy

Intensity-modulated radiation therapy (IMRT) can be performed by using compensators. To make a compensator for an IMRT practice, it is required to calculate the effective attenuation coefficient (μ{sub eff}) of its material, which is affected by various factors. We studied the effect of the variation of the most important factors on the calculation of the μ{sub eff} of the cerrobend compensator for 6-MV photon beams, including the field size, compensator thickness, and off-axis distance. Experimental measurements were carried out at 100 cm source-to-surface distance and 10 cm depth for the 6-MV photon beams of an Elekta linac using various field size, compensator thickness, and off-axis settings. The field sizes investigated ranged from 4 × 4 to 25 × 25 cm{sup 2} and the cerrobend compensator thicknesses from 0.5–6 cm. For a fixed compensator thickness, variation of the μ{sub eff} with the field size ranged from 3.7–6.8%, with the highest value attributed to the largest compensator thickness. At the reference field size of 10 × 10 cm{sup 2}, the μ{sub eff} varied by 16.5% when the compensator thickness was increased from 0.5–6 cm. However, the variation of the μ{sub eff} with the off-axis distance was only 0.99% at this field size, whereas for the largest field size, it was more significant. Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of the compensator μ{sub eff} for the 6-MV photon beam. Therefore, it is recommended to consider these parameters when calculating the compensator thickness for an IMRT practice designed for these beams. The off-axis distance had a significant effect on the calculation of the μ{sub eff} only for the largest field size. Hence, it is recommended to consider the effect of this parameter only for field sizes larger than 25 × 25 cm{sup 2}.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Data Sheets for A=242

Here, detailed level schemes, decay schemes, band structure, and the experimental data on which they are based are presented for all nuclei with mass number A=242. The experimental data are evaluated and adopted values are given for level and radiation properties. For references on theory refer to the NSR file at the web site given below under Cutoff Date:. This evaluation replaces the A=242 publication by Y. A. Akovali in Nuclear Data Sheets 96, 177 (2002) (2002Ak06).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Estimation of Hybrid Quantum Mechanical Molecular Mechanical Polarization Energies for Small Molecules Using Polarizable Force-Field Approaches

Here in this work, we report two polarizable molecular mechanics (polMM) force field models for estimating the polarization energy in hybrid quantum mechanical molecular mechanical (QM/MM) calculations. These two models, named the potential of atomic charges (PAC) and potential of atomic dipoles (PAD), are formulated from the ab initio quantum mechanical (QM) response kernels for the prediction of the QM density response to an external molecular mechanical (MM) environment (as described by external point charges). The PAC model is similar to fluctuating charge (FQ) models because the energy depends on external electrostatic potential values at QM atomic sites; the PAD energy depends on external electrostatic field values at QM atomic sites, resembling induced dipole (ID) models. To demonstrate their uses, we apply the PAC and PAD models to 12 small molecules, which are solvated by TIP3P water. The PAC model reproduces the QM/MM polarization energy with a R 2 value of 0.71 for aniline (in 10,000 TIP3P water configurations) and 0.87 or higher for other eleven solute molecules, while the PAD model has a much better performance with R 2 values of 0.98 or higher. The PAC model reproduces reference QM/MM hydration free energies for 12 solute molecules with a RMSD of 0.59 kcal/mol. The PAD model is even more accurate, with a much smaller RMSD of 0.12 kcal/mol, with respect to the reference. Lastly, this suggests that polarization effects, including both local charge distortion and intramolecular charge transfer, can be well captured by induced dipole type models with proper parametrization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BiasMDP: Carrier lifetime characterization technique with applied bias voltage

A characterization method is presented, which determines fixed charge and interface defect densities in passivation layers. This method bases on a bias voltage applied to an electrode on top of the passivation layer. During a voltage sweep, the effective carrier lifetime is measured by means of microwave detected photoconductivity. When the external voltage compensates the electric field of the fixed charges, the lifetime drops to a minimum value. This minimum value correlates to the flat band voltage determined in reference impedance measurements. This correlation is measured on p-type silicon passivated by Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}/HfO{sub 2} stacks with different fixed charge densities and layer thicknesses. Negative fixed charges with densities of 3.8 × 10{sup 12 }cm{sup −2} and 0.7 × 10{sup 12 }cm{sup −2} are determined for Al{sub 2}O{sub 3} layers without and with an ultra-thin HfO{sub 2} interface, respectively. The voltage and illumination dependencies of the effective carrier lifetime are simulated with Shockley Read Hall surface recombination at continuous defects with parabolic capture cross section distributions for electrons and holes. The best match with the measured data is achieved with a very low interface defect density of 1 × 10{sup 10 }eV{sup −1} cm{sup −2} for the Al{sub 2}O{sub 3} sample with HfO{sub 2} interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dissociation curves of diatomic molecules: A DC-DFT study

We investigate dissociation of diatomic molecules using standard density functional theory (DFT) and density-corrected density functional theory (DC-DFT) compared with CCSD(T) results as reference. The results show the difference between the HOMO values of dissociated atomic species often can be used as an indicator whether DFT would predict the correct dissociation limit. DFT predicts incorrect dissociation limits and charge distribution in molecules or molecular ions when the fragments have large HOMO differences, while DC-DFT and CCSD(T) do not. The criteria for large HOMO difference is about 2 ∼ 4 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-similar Reynolds-averaged mechanical–scalar turbulence models for Rayleigh–Taylor mixing induced by power-law accelerations in the small Atwood number limit

Analytical self-similar solutions to two-, three-, and four-equation Reynolds-averaged mechanical–scalar turbulence models describing turbulent Rayleigh–Taylor mixing driven by a temporal power-law acceleration are derived in the small Atwood number (Boussinesq) limit. The solutions generalize those previously derived for constant acceleration Rayleigh–Taylor mixing for models based on the turbulent kinetic energy K and its dissipation rate ε, together with the scalar variance S and its dissipation rate χ [O. Schilling, “Self-similar Reynolds-averaged mechanical–scalar turbulence models for Rayleigh–Taylor, Richtmyer–Meshkov, and Kelvin–Helmholtz instability-induced mixing in the small Atwood number limit,” Phys. Fluids 33, 085129 (2021)]. The turbulent fields are expressed in terms of the model coefficients and power-law exponent, with their temporal power-law scalings obtained by requiring that the self-similar equations are explicitly time-independent. Mixing layer growth parameters and other physical observables are obtained explicitly as functions of the model coefficients and parameterized by the exponent of the power-law acceleration. Values for physical observables in the constant acceleration case are used to calibrate the two-, three-, and four-equation models, such that the self-similar solutions are consistent with experimental and numerical simulation data corresponding to a canonical (i.e., constant acceleration) Rayleigh–Taylor turbulent flow. The calibrated four-equation model is then used to numerically reconstruct the mean and turbulent fields, and turbulent equation budgets across the mixing layer for several values of the power-law exponent. Finally, the reference solutions derived here can be used to understand the model predictions for strongly accelerated or decelerated Rayleigh–Taylor mixing in the large Reynolds number limit.

42 ENGINEERING↗

Post-Irradiation Evaluation of Eurofer97 Fracture Toughness Using Miniature Multinotch Bend Bar Specimens

In this study, we performed fracture toughness characterization of ten neutron-irradiated Eurofer97 variants using precracked miniature multi-notch bend bar (M4CVN) specimens based on the Master Curve method in the ASTM E1921 standard. The neutron irradiation was performed in the flux trap position of the High Flux Isotope Reactor (HFIR) of the Oak Ridge National Laboratory (ORNL) with the nominal irradiation temperature of 300°C and irradiation dose of 2.5 displacements per atom (dpa). Depending on the irradiation temperature and materials, we observed different degrees of irradiation hardening and embrittlement for ten Eurofer97 variants. The upper shift in the Master Curve reference temperature T0Q vs. the increase in Vickers microhardness values showed a liner relationship for only a few materials indicating different irradiation responses of the Eurofer97 variants.

Chen, Xiang↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiautomatic segmentation of liver metastases on volumetric CT images

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

60 APPLIED LIFE SCIENCES↗

Optical Properties of Epitaxial Al{sub x}In{sub 1-x}Sb Alloy Layers

Optical studies of unstrained narrow-gap Al{sub x}In{sub 1-x}Sb semiconductor alloy layers are carried out. The layers are grown by molecular-beam epitaxy on semi-insulating GaAs substrates with an AlSb buffer. The composition of the alloys is varied within the range of x = 0-0.52 and monitored by electron probe microanalysis. The band gap E{sub g} is determined from the fundamental absorption edge with consideration for the nonparabolicity of the conduction band. The refined bowing parameter in the experimental dependence E{sub g}(x) for the Al{sub x}In{sub 1-x}Sb alloys is 0.32 eV. This value is by 0.11 eV smaller than the commonly referred one.

36 MATERIALS SCIENCE↗

Magnetic and Elastic Vibrations in Manganese–Zinc Spinel Crystals as the Functions of Anisotropy Constant

The amplitudes of magnetic and elastic vibrations for Mn{sub 0.61}Zn{sub 0.35}Fe{sub 2.04}O{sub 4} spinel crystalline slab are calculated by solving the equations describing the magnetic and elastic dynamics. The anisotropy constants, magnetization, second-order elastic constants and magnetoelastic coupling constants for a studied crystal are expressed as the functions of temperature. The magnetization vector and elastic shear components are found as the functions of the first magnetic anisotropy constant at different values of an external constant magnetic field greater than a saturation field. The procession patterns for normally and tangentially magnetized slabs are displayed for two values of the first anisotropy constant. High absolute values of the first anisotropy constant are shown to refer to reorientation of the magnetization vector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mapping Peptidergic Cells in Drosophila : Where DIMM Fits In

The bHLH transcription factor DIMMED has been associated with the differentiation of peptidergic cells in Drosophila. However, whether all Drosophila peptidergic cells express DIMM, and the extent to which all DIMM cells are peptidergic, have not been determined. To address these issues, we have mapped DIMM expression in the central nervous system (CNS) and periphery in the late larval stage Drosophila. At 100 hr after egg-laying, DIMM immunosignals are largely congruent with a dimm-promoter reporter (c929-GAL4) and they present a stereotyped pattern of 306 CNS cells and 52 peripheral cells. We assigned positional values for all DIMM CNS cells with respect to reference gene expression patterns, or to patterns of secondary neuroblast lineages. We could assign provisional peptide identities to 68% of DIMM-expressing CNS cells (207/ 306) and to 73% of DIMM-expressing peripheral cells (38/52) using a panel of 24 markers for Drosophila neuropeptide genes. Furthermore, we found that DIMM co-expression was a prevalent feature within single neuropeptide marker expression patterns. Of the 24 CNS neuropeptide gene patterns we studied, six patterns are .90% DIMM-positive, while 16 of 22 patterns are >40% DIMM-positive. Thus most or all DIMM cells in Drosophila appear to be peptidergic, and many but not all peptidergic cells express DIMM. The co-incidence of DIMM-expression among peptidergic cells is best explained by a hypothesis that DIMM promotes a specific neurosecretory phenotype we term LEAP. LEAP denotes Large cells that display Episodic release of Amidated Peptides.

59 BASIC BIOLOGICAL SCIENCES↗

Site-Representative Biota Concentration Guides at Los Alamos

Biota dose assessment at Los Alamos National Laboratory, LANL, follows the guidance of the DOE Standard, DOE-STD-1153-2002. As described in Section 2, general screening is performed using Biota Concentration Guides, BCGs, which are defined as "the limiting concentration of a radionuclide in soil, water, or sediment that would not lead to exceeding dose limits for the protection of biota in the environment." For the general screening, the maximum concentrations in water, sediment, and soil are compared with each radionuclide-specific BCG (DOE-STD-1153-2002 Table 2.1) and the sum of the fractions is calculated (DOE-STD-1153-2002 page M1-25.) The DOE Standard encourages each site to establish site-specific or site-representative BCGs (DOE-STD-1153-2002 Module 1 pages 10, 24-26, 43, 45-47, 50, 59, 61-64, 79, 81-86; Module 2 pages 31, 41, 49, 50, 53; and Module 3 page 29). The purpose of this paper is to establish site-representative BCGs for cesium-137 and strontium-90 in water, sediment, and soil. Sections 4.1 and 7.1.3.2 of DOE-STD-1153-2002 recommend the use of site-specific "lumped parameter values." The important lumped parameter is the bioaccumulation factor referred to in the DOE Standard as Biv. It is also commonly called the wet-weight concentration ratio C r ; see Module 3 Section 3.1 (page M3-19) of DOE-STD-1153-2002.

54 ENVIRONMENTAL SCIENCES↗

Building America Best Practices Series: Volume 17 - Energy Renovations-Insulation: A Guide for Contractors to Share With Homeowners

This guide will help contractors and homeowners identify ways to make their homes more comfortable, more energy efficient, and healthier to live in. It also identifies the steps to take, with the help of a qualified home performance contractor, to increase their home’s insulation, ensure healthy levels of ventilation, and prevent moisture problems. Contractors can use this document to explain the value of these insulation measures to their customers. The references in this document provide further explanation of insulation techniques and technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗