3D track reconstruction of low-energy electrons in the MIGDAL low pressure optical time projection chamber

Here, we demonstrate three-dimensional track reconstruction of electrons in a low pressure (50 Torr) optical TPC consisting of two glass GEMs with an ITO strip readout in CF 4 and CF 4 /Ar mixtures. The reconstructed tracks show a variety of event topologies, including short tracks from photoelectrons induced by 55 Fe 5.9 keV X-rays and long tracks from gamma ray interactions and beta decays. Algorithms for event identification and track ridge detection are discussed as well as multiple methods for integrating information from the camera image and ITO waveforms with the goal of full 3D reconstruction of the track.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and Performance of New Silicon Stripixel Detector for the PHENIX Experiment at RHIC: Beta Source, Cosmic-rays and Proton Beam at 120 GeV

We are constructing a Silicon Vertex Tracker detector (VTX) for the PHENIX experiment at RHIC. Our main motivation is to enable measurements of heavy flavor production (charm and beauty) in p+p, p+d and A+A collisions. Such data will illuminate the properties of the matter created in high-energy heavy-ion collisions. The measurements also will reveal the distribution of gluons in protons from p+p collisions. The VTX detector consists of four layers of barrel detectors and covers |{eta}|<1.2, and almost a 2{pi} in azimuth. The inner two silicon barrels consist of silicon pixel sensors; their technology accords with that of the ALICE1LHCB sensor-readout hybrid. The outer two barrels are silicon stripixel detectors with a new 'spiral' design, and a single-sided sensor with 2-dimensional (X, U) readout. In this paper, we describe the silicon stripixel detector and discuss its performance, including its response to electrons from a beta source ({sup 90}Sr), muons from cosmic-rays, and a 120 GeV proton beam. The results from the proton beam demonstrate that the principle of two-dimensional position sensitivity based on charge sharing works; the signal-to-noise value is 10.4, the position resolution is 33.6 {micro}m for X-stripixel (35.2 {micro}m for U-stripixel), and the tracking efficiencies in the X- and U-stripixels are, over 98.9 {+-} 0.2%. The stripixel detector within the VTX project is in the pre-production phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies of BONuS12 Radial GEM Detector and TCS Beam Spin Asymmetry in CLAS12

The Barely Offshell Nucleon Structure (BONuS12) experiment adopted the concept of spectator tagging technique to study the nearly-free neutron structure function Fn2 in the CLAS12 of Jefferson Lab. A novel Radial Time Projection Chamber (RTPC) detector was built, tested and integrated into the CLAS12 system to detect a back-moving low momentum tagged proton in d(e,ep)X deep-inelastic scattering. It was a 40 cm long gaseous detector consisting of 3 layers of cylindrical GEM foils for the charge amplification, with the data readout directly from the surrounding padboard. The RTPC detected the recoiling spectator proton, in coincidence with the scattered electron in the CLAS12. Nucleon structure functions are directly related to the partonic functions, quarks momentum distribution in one dimension. A Generalized Parton Distribution (GPD) came to the lime-light as it encodes the information of both longitudinal momentum and transverse position of partons inside the nucleons. Factorization of hard process such as DVCS allows to access GPDs. Timelike Compton Scattering (TCS), ?p ? ??p, is another process that allows to access the GPDs. TCS is studied experimentally in the CLAS12 of Jefferson lab using the quasi-real photoproduction of time-like photon which eventually decays to lepton pair. This dissertation presents the concept of spectator tagging in BONuS12, and the research and development efforts during the BONuS12 preparation leading up to the successful data-taking during spring and summer 2020. In addition, analysis framework to extract the beam spin asymmetry of TCS events through the CLAS12 Run group A data is presented.

Poudel, Jiwan↗

A depth-of-interaction PET detector using mutual gain-equalized silicon photomultiplier

We developed a prototype high resolution, high efficiency depth-encoding detector for PET applications based on dual-ended readout of LYSO array with two silicon photomultipliers (SiPMs). Flood images, energy resolution, and depth-of-interaction (DOI) resolution were measured for a LYSO array - 0.7 mm in crystal pitch and 10 mm in thickness - with four unpolished parallel sides. Flood images were obtained such that individual crystal element in the array is resolved. The energy resolution of the entire array was measured to be 33%, while individual crystal pixel elements utilizing the signal from both sides ranged from 23.3% to 27%. By applying a mutual-gain equalization method, a DOI resolution of 2 mm for the crystal array was obtained in the experiments while simulations indicate {approx}1 mm DOI resolution could possibly be achieved. The experimental DOI resolution can be further improved by obtaining revised detector supporting electronics with better energy resolutions. This study provides a detailed detector calibration and DOI response characterization of the dual-ended readout SiPM-based PET detectors, which will be important in the design and calibration of a PET scanner in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pilot tone as a key to improving the spatial resolution of eBPMs

At Elettra, the Italian synchrotron light source, an internal project has been started to develop an electron beam position monitor capable of achieving sub-micron resolution with a self-compensation feature. In order to fulfil these requirements, a novel RF front end has been designed. A high isolation coupler combines the input signals with a known pilot tone which is generated by the readout system. This allows the parameters of the four channels to be continuously calibrated, by compensating the different responses of each channel. A similar technique is already known, but for the first time experimental results have shown the improvement in resolution due to this method. The RF chain was coupled with a 4-channel digitizer based on 160 MHz, 16 bits ADCs and an Altera Stratix FPGA. At first, no additional processing was done in the FPGA, collecting only the raw data from the ADCs; the position was calculated through the FFT of each signal. A simulation was also performed to verify the analytic relation between spatial resolution and signal-to-noise ratio; this was very useful to better understand the behaviour of the system with different sources of noise (aperture jitter, thermal noise, etc.). The experimental data were compared with the simulation, showing indeed a perfect agreement with the latter and confirming the capability of the system to reach sub-micrometric accuracy. Therefore, the use of the pilot tone greatly improves the quality of the system, correcting the drifts and increasing the spatial resolution by a factor of 4 in a time window of 24 hours.

43 PARTICLE ACCELERATORS↗

Improvement of {gamma}-ray energy resolution of LaBr{sub 3}:Ce{sup 3+} scintillation detectors by Sr{sup 2+} and Ca{sup 2+} co-doping

Commercially available LaBr{sub 3}:5% Ce{sup 3+} scintillators show with photomultiplier tube readout about 2.7% energy resolution for the detection of 662 keV {gamma}-rays. Here we will show that by co-doping LaBr{sub 3}:Ce{sup 3+} with Sr{sup 2+} or Ca{sup 2+} the resolution is improved to 2.0%. Such an improvement is attributed to a strong reduction of the scintillation light losses that are due to radiationless recombination of free electrons and holes during the earliest stages (1-10 ps) inside the high free charge carrier density parts of the ionization track.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Franck-Condon Tuning of Optical Cycling Centers by Organic Functionalization

Laser induced electronic excitations that spontaneously emit photons and decay directly to the initial ground state (“optical cycling transitions”) are used in quantum information and precision measurement for state initialization and readout. To extend this primarily atomic technique to large, organic compounds, we theoretically investigate optical cycling of alkaline earth phenoxides and their functionalized derivatives. We find that optical cycle leakage due to wave function mismatch is low in these species, and can be further suppressed by using chemical substitution to boost the electron-withdrawing strength of the aromatic molecular ligand through resonance and induction effects. This provides a straightforward way to use chemical functional groups to construct optical cycling moieties for laser cooling, state preparation, and quantum measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

A combined time projection chamber-Cherenkov (TPCC) prototype detector has been developed as part of the detector research and development program for a future electron-ion collider (E!C). The prototype was tested at the Fermilab test beam facility (FTBF) to provide a proof of the principle to demonstrate the ability to measure particle tracks and provide particle identification (P!D) information within a common detector volume. The time projection chamber (TPC) portion consists of a 10 × 10 × 10 cm 3 field cage, which delivers charge from tracks to a quadruple gas electron multiplier (GEM) with zigzag-shaped charge collection anodes. The Cherenkov portion consists of a photosensitive quadruple GEM detector with a Cs! photocathode. As tracks pass through the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the Cs! photocathode. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF 4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, including the position resolution as well as the particle id capabilities of the detector, are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Telecom-Luminescent and Room Temperature Coherent Tetrathiafulvalene-Based Qubits in Spin-Rich Solids

One of the main challenges facing quantum information science (QIS) is the development of robust qubits that can be op-erated under ambient conditions. Current state-of-the-art anionic nitrogen vacancy center (NV–) defect qubits are robust enough to be operated at room temperature but lack scalability and tunability. These are areas where molecular qubits excel, although they typically suffer from poor air stability and fast decoherence at elevated temperatures and in magneti-cally noisy environments. Organic-based systems offer advantages to this end, although examples retaining room tem-perature coherence are still rare. Furthermore, most organic-based systems lack optical transitions similar to NV– centers that could allow for optical initialization and readout. Here we report two new organic-based qubit candidates that demonstrate room temperature coherence in nuclear and electron spin-rich environments. These qubits luminesce far into the near-infrared (NIR, 700-1700 nm) and telecom (~1260-1625 nm) regions, ideal for biological sensing and com-munications applications, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of a Kinetic Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic inductance traveling-wave parametric amplifier (KITWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ$ = 6.3 ± 0.5 K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the performance of the KITWPA to be limited by the temperature of its inputs and by an excess of noise $T_{ex}$ = 1.9 K. In this work, the dissipation of the rf pump of the KITWPA constitutes the main power load at 4 K and is about 1% that of a HEMT. These combined noise and power dissipation values pave the way for the use of the KITWPA as a replacement for semiconductor amplifiers.

97 MATHEMATICS AND COMPUTING↗

Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2 SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing Solar Particle Event Spectra from Absorbed Dose Measurements

The space radiation environment is unlike anything encountered on Earth. It is dominated by heavy charged particles consisting of highly charged nuclei with atomic numbers ranging from 1 to 94 with a broad spectrum of kinetic energies. The three primary sources of radiation in space are trapped belts, galactic cosmic rays (GCRs), and solar particle events (SPEs). The trapped belts are only of concern near bodies with significant magnetic fields and GCR flux spectra are relatively well-predicted using models that account for solar modulation of the local interstellar spectrum. SPEs, which consist primarily of protons, are difficult to predict in terms of occurrence, duration, intensity, and energy spectrum. SPE intensity and energy spectrum are critical for understanding radiation exposure-related health effects for astronauts in space. The National Aeronautics and Space Administration (NASA) relies on data from the Geostationary Operational Environmental Satellite series to characterize intensities and energy spectra of SPEs near Earth. However, these data are not applicable for spacecraft in other regions of the solar system. To understand the radiation environment for astronauts embarking on travel beyond Earth orbit, NASA is developing the Hybrid Electronic Radiation Assessor (HERA), a distributed dosimetry system that employs a solid-state silicon sensor coupled with the Timepix readout chip. The pixelated nature of the detector permits detailed analyses of charged particle tracks which can then be used to characterize the fluence spectrum at the location of the detector. Despite the unprecedented level of detail regarding the radiation environment provided by these detectors, knowledge of the fluence spectrum at all locations within the vehicle, specifically inside of astronauts, is desired to fully characterize the associated risk of harmful health effects. Radiation transport of the external radiation environment, considering the shielding provided by the vehicle, other objects, and even astronauts, is performed to obtain this information. Thus, there is clearly a need to define the external radiation environment using measurements performed within the vehicle. The number of detectors that may be flown as a part of HERA is limited by logistics, including data, power, and mass restrictions. The current configuration for crewed flight consists of six detectors at various locations with in the Orion Multi-Purpose Crew Vehicle (MPCV). It follows that an external proton fluence spectrum can be characterized with at most six energy bins with traditional matrix inversion techniques. The purpose of the present study is to determine whether it is possible to reconstruct SPE spectra with greater resolution from absorbed dose measurements and knowledge of the response of individual detectors using linear programming.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Low-Mass Limit: Dark Matter Detectors with eV-Scale Energy Resolution

The SuperCDMS SNOLAB experiment will be a 20-kg scale Si and Ge direct dark matter detection experiment designed to probe down to 300 MeV in dark matter (DM) mass through DM-nucleus scattering and 500 keV in DM electron scattering. In order to reach these low masses with appreciable sensitivity to dark matter, it needs to achieve very low energy resolution ($\le 10$ ev) for nuclear recoils in both detector materials, which will be achieved using a new detector design and operating mode, CDMS HV. This detector is designed to operate at a bias of 100V to convert charges liberated in our detector targets to into phonon energy in order to resolve individual electron-hole pairs. This has never before been achieved in a kg-scale detector. In this thesis, I cover three elements of the design of the CDMS HV detectors. I discuss the detector physics controlling how charges and phonons are generated in our detector crystals, comparing theory to results of recent experiments carried out at Stanford. I move on to describe the operating principles of our phonon-mediated charge readout, as well as the design of the CDMS HV detector. I then describe the performance tests of early CDMS HV prototypes in conjunction with the SuperCDMS SNOLAB electronics, and discuss the path towards achieving single electron-hole pair resolving detectors at the kg-scale given the performance obtained thus far. As a result of these tests, we were able to refine our noise and sensor dynamics models, and develop new metrics for diagnosing non-ideal sources of noise to aid in reducing coupling of the external environment to our detectors. In order to study the microphysics of phonon and charge production in our target crystals, we fabricated a number of gram-scale devices with various sensor designs in order to separate sensor and environmental effects from intrinsic crystal properties. These devices provided the first successful demonstrating of using voltage to amplify charge energ y by production of phonons (the Neganov-Trofimov-Luke effect! ) in order to resolve electron-hole pairs, and opened up a new regime of dark matter and photon science at the gram-scale that we are just beginning to explore. A first dark matter search was carried out with one of these gram-scale devices, producing world-leading limits on electron-recoiling dark matter between 0.5 and 5 MeV in dark matter mass for multiple form factors. This device achieved a phonon resolution of 10~eV, allowing a single gram-day of exposure to rival kg-days of exposure in the competing liquid-noble based electron-recoil search.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of high-resolution muon tracking systems based on micro-pattern detectors

A muon tracking system consisting of four 9 cm x 10 cm sized bulk Micromegas detectors with 128 {mu}m amplification-gap and two 10 cm x 10 cm triple GEM detectors is foreseen for high-precision tracking of 140 GeV muons at the H8 beamline at CERN with a rate of up to 10 kHz and an overall resolution below 40 {mu}m. Larger detectors with an active area of 0.5 m{sup 2} and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9 keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO{sub 2}. The signals were digitized using 1 GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80 {mu}m was measured using a fast Gassiplex based strip readout with readout strips of 150 {mu}m width and a pitch of 250 {mu}m. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the front-end boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the lithium beam diagnostic at JET

A 60 kV neutral Li beam is injected into the edge plasma of JET to measure the electron density. The beam observation system has been improved by replacing a Czerny-Turner spectrometer with a high-resolution transmission-grating spectrometer and a fast back-illuminated frame-transfer camera. The larger throughput of the spectrometer, the increased sensitivity, and the faster readout of the new camera allow inter-ELM (edge localized mode) measurements (frame rate of 100 Hz). The calibration of the setup, as well as an improved spectral fitting technique in the presence of carbon background radiation, is discussed in detail. The density calculation is based on a statistical analysis method. Results are presented for different plasma scenarios.