Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

SpecFIDLER User Manual: Software Version 2.4.0

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.5.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.3.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient detection, analysis and classification of lightning radiation fields

Modeling the large scale lightning flash structure is considered. Large scale flash data has been measured from strip charts of storms of August 5, August 26, and September 12, 1975. The data is being processed by a computer program called SASEV to estimate the large scale flash statistics. The program, experimental results, and conclusions for the large scale flash structure are described. The progress made in examining the internal flash structure consists mainly of developing the software required to process the NASA digital tape data. A FORTRAN program has been written for the statistical analysis of series of events. The statistics computed and tests performed are found to be particularly useful in the analysis of lightning data.

Harger, R. O.↗

Gamma-radiation with E gamma 5 MeV detected from Seyfert galaxy 3C120 and region with 1" = 190 deg and b" = 20 deg

The observation of the Galaxy anticenter region in gamma-rays with E gamma = 5 / 100 MeV was made by gamma-telescope Natalya-1 in a balloon flight. The flight was performed at the ceiling 5.1 + or - 0.1 g/sq cm, magnetic cutoff being 17 GV. The description of the instrument and the analysis of the experiment conditions are given. The tracks of electron-positron pairs generated by gamma-quanta in the convertors were detected by wire spark chambers. The recorded events were classified manually by an operator using a graphic display into three classes: pairs, single and bad events. The arrival angle of gamma-quanta and their energy for selected gamma-ray events (pairs and singles) were determined through multiple scattering of pair components in the convertors. On the basis of the data obtained the celestial maps were made in gamma-rays for E sub gamma 5 MeV and E gamma 20 MeV energy ranges.

Damle, S. V.↗

Electron scattering and the distances to cluster cooling flows

Cluster cooling flows have electron-scattering optical depths which are estimated to be about 0.01. Many of the cluster-dominant galaxies centered in cluster cooling flows have active nuclei, and about 1 percent of the luminosity from the active nuclei should appear as diffuse, scattered radiation. It is shown here that detection of this scattered radiation at radio wavelengths can provide a measure of the distance to the cluster that is independent of the Hubble constant. Observations of the scattered surface brightness profile can also be used to test for clumpiness in the gas, for variations in the central radio source on time scales less than 100,000 yr, and for the degree of beaming of radiation from the central source.

Wise, Michael W.↗

Effect of Additives: Gamma-Ray Sensors Based on Ionizing Organic Nanocomposites

We have developed ionizing organic-based composites which have demonstrated great promise for radiation sensing. Nickel oxide has been proven as an active material for detecting high energy radiation. The oxidation state of unusual oxides such as nickel oxide in nanocomposites of ionizing organics changes much faster than thin film or bulk, and hence increases the sensitivity for radiation sensing. The resistivity of the oxide composite increases following sequential irradiation processes because of the decrease in holes' concentration. In this paper, we will present the effect of additional oxidizing agent on the morphology, processing and sensing of gamma-rays by oxides - urea based nanocomposites. It was observed that addition of MnO2 decreases the sensitivity. However, it recovers to original properties after irradiation much faster than undoped composites.

Vishall Dayal↗

Scalable, large-area optical sensing platform with compact light delivery and imaging system

An optode has a planar radiation guiding medium having a first planar surface and a second planar surface and one or more perimeter surfaces bounded by the first and second planar surfaces. An excitation energy source of the optode is configured to output into the radiation guiding medium first energy at a wavelength selected to excite a fluorophore. The optode also includes a photodetector configured to image at least a portion of the first planar surface of the radiation guiding medium by detecting second energy transmitted through the radiation guiding medium.

Zhang, Xufeng↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

Tl+-based and mixed halide A3B2X9-type scintillators

Inorganic halides (e.g., inorganic halide scintillators) of the general formula A3B2X9, including inorganic halides comprising thallium monovalent cations and/or combinations of different halides, are described. Radiation detectors including the inorganic halide scintillators and methods of using the detectors to detect high energy radiation are also described. In some cases, the scintillators can include a gadolinium cation, a boron cation, a lithium cation, a chloride ion, or combinations thereof and the scintillator can be used to detect neutrons.

Rutstrom, Daniel↗

Integrated Fluorescence

A detection method is integrated with a filtering method and an enhancement method to create a fluorescence sensor that can be miniaturized. The fluorescence sensor comprises a thin film geometry including a waveguide layer, a metal film layer and sensor layer. The thin film geometry of the fluorescence sensor allows the detection of fluorescent radiation over a narrow wavelength interval. This enables wavelength discrimination and eliminates the detection of unwanted light from unknown or spurious sources.

Tuma, Margaret↗

Contrastive Machine Learning with Gamma Spectroscopy Data Augmentations for Detecting Shielded Radiological Material Transfers

Data analysis techniques can be powerful tools for rapidly analyzing data and extracting information that can be used in a latent space for categorizing observations between classes of data. Machine learning models that exploit learned data relationships can address a variety of nuclear nonproliferation challenges like the detection and tracking of shielded radiological material transfers. The high resource cost of manually labeling radiation spectra is a hindrance to the rapid analysis of data collected from persistent monitoring and to the adoption of supervised machine learning methods that require large volumes of curated training data. Instead, contrastive self-supervised learning on unlabeled spectra can enhance models that are built on limited labeled radiation datasets. This work demonstrates that contrastive machine learning is an effective technique for leveraging unlabeled data in detecting and characterizing nuclear material transfers demonstrated on radiation measurements collected at an Oak Ridge National Laboratory testbed, where sodium iodide detectors measure gamma radiation emitted by material transfers between the High Flux Isotope Reactor and the Radiochemical Engineering Development Center. Label-invariant data augmentations tailored for gamma radiation detection physics are used on unlabeled spectra to contrastively train an encoder, learning a complex, embedded state space with self-supervision. A linear classifier is then trained on a limited set of labeled data to distinguish transfer spectra between byproducts and tracked nuclear material using representations from the contrastively trained encoder. The optimized hyperparameter model achieves a balanced accuracy score of 80.30%. Any given model—that is, a trained encoder and classifier—shows preferential treatment for specific subclasses of transfer types. Regardless of the classifier complexity, a supervised classifier using contrastively trained representations achieves higher accuracy than using spectra when trained and tested on limited labeled data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lightning mapping system

A Lightning Detection and Ranging (LDAR) System is being implemented at KSC in Florida. The first operational use is expected in the late summer of 1991. The system is designed to map the location of in-cloud and cloud-to-ground lightning based on the time of arrival (TOA) of electromagnetic radiation. The system detects very high frequency (VHF) radiation and designed to map the volumetric extent of lightning. The system implements two independent antenna arrays to provide a fast data quality check, as necessary for a real-time warning system. The system performance goals and a comparison with a similar system implemented in the mid-1970's is made.

Lennon, C.↗

Gamma-ray line afterglow from burst environments

We consider photoerosion and direct pair production in a medium surrounding a gamma-ray burst. The resulting secondary gamma-rays may provide diagnostic tools of these environments and, in turn, of the nature of the bursters themselves. In some instances short-lived nuclides are formed; the beta-delayed gamma-rays produced from their decays provide the signatures of the photoerosion. In addition, annihilation radiation produced from positrons resulting from direct pair production is related to the plasma conditions in the medium. We investigate the plausibility of detecting the various radiations. Under extremely favorable conditions, the photoerosion afterglow might be detectable with the present generation of detectors. However, the positron annihilation line should be detectable under a fairly wide range in the conditions of the medium.

Fencl, H. S.↗

Device system and method for miniaturized radiation spectrometer

A device/system for radiation sensing is configured to detect high and low LET radiation. The radiation sensing system may include a high LET detector and a low LET detector coupled to the high LET detector by a CPU, wherein the high LET detector and the low LET detector are assembled within a single unit. The device/system may also include a high LET and low LET detector that may be coupled together without an internal CPU. Overall, the device/system may be a stand-alone system and/or coupled to an external processing device. The device/system may also be approximately 6.times.6.times.2 cm.sup.3 in size, making it hand portable and may weigh less or equal to approximately ninety (90) grams, and operate on less than or approximately 0.25 watts of power.

Stassinopoulos, Epaminondas G.↗