Retrofitting Air Conditioning and Duct Systems in Hot, Dry Climates

This technical report describes CARB's work with Clark County Community Resources Division in Las Vegas, Nevada, to optimize procedures for upgrading cooling systems on existing homes in the area to implement health, safety, and energy improvements. Detailed monitoring of five AC systems showed that three of the five systems met or exceeded air flow rate goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Application of a Construction Quality Process to Existing Home Retrofits

The Partnership for Home Innovation developed a construction quality process for new and existing high performance homes (HPH) in which high performance goals are established, specifications to meet those goals are defined, and construction monitoring points are added to the construction schedule so that critical energy efficiency details are systematically reviewed, documented, and tested in a timely manner. This report follows the evolution of the construction quality process from its development for new homes, to its application in the construction of a high performance home with enhanced specifications, and its application in a crawlspace renovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations

Basements in climates 6 and 7 can account for a fraction of a home's total heat loss when fully conditioned. Such foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with it. Because below-grade basements are increasingly used for habitable space, cold foundation walls pose challenges for moisture contribution, energy use, and occupant comfort.

42 ENGINEERING↗

Yuma Border Patrol Area Lighting Retrofit LED System Performance in a Trial Installation – Two Years Later

Documentation of the Yuma Sector Border Patrol Area lighting LED trial demonstration continues to provide a better understanding of LED technology performance in a high ambient temperature and high solar radiation environment. Measured data at the project site showed illuminances changing more rapidly than anticipated. As previously predicted, the causes for these observed changes are mostly if not completely explained by dirt accumulation. The laboratory measurements showed not only the effect of dirt on lumen output, but also on the distribution of light exiting the luminaire.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kokhanok Renewable Energy Retrofit Analysis

In 2010, the community of Kokhanok, Alaska, installed two 90-kW wind turbines, battery storage, a converter, and equipment for integration. Researchers at the National Renewable Energy Laboratory performed an analysis and modeling using the HOMER and REopt software modeling packages.The analysis was designed to answer the following questions: 1) What is required to achieve a 50 percent reduction in power plant diesel fuel consumption in a diesel microgrid? 2) What is required to achieve a 50 percent reduction in 'total' (diesel and heating oil) consumption in a remote community? 3) What is the impact and role of energy efficiency? This presentation provides an introduction to the community of Kokhanok, Alaska; a summary of energy data; and an overview of analysis results and conceptual design.

17 WIND ENERGY↗

Yuma Border Patrol Lighting Retrofit: Final LED System Performance Assessment of Trial and Full Installation

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial evaluation in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations, and illuminance measurements were recorded initially and at 2500 hours, 5000 hours, 7000, and 11,000 hours of operation. Additionally, four second-generation LED luminaires installed as part of the full installation were evaluated initially and again after 4,000 hours of operation. While the initial energy, lighting quality, and maintenance benefits relative to the incumbent high-pressure sodium system were very satisfactory, the study raises important questions regarding the long-term performance of LED lighting systems in high-temperature environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alstom’s Chemical Looping Combustion Technology for CO 2 Capture for New and Retrofit Coal-Fired Power Plants

Cold Flow Modeling (CFM) is a critical tool to understand solid transport, corresponding process stability, and the impact on the performance of the LCL-CTM technology. As such it plays a central role in the development of the LCL-CTM process and deserves a standalone report in the final reporting on Phase II of the collaboration with DOE under award DE FE0009484. The 40-Foot Cold Flow Model (CFM) was constructed before the 3 MWth Prototype. The purpose of the CFM is to: develop design and operational information to design the Prototype help resolve solids transport problems that occur with the Prototype provide Prototype operator training. This report provides a review on the use of the CFM to achieve better understanding, design, and operation of solid transport for the LCL-CTM technology. Significant progress was made by iteratively designing, operating, and testing between the CFM and the Prototype scale. Fundamental understanding of the transport of reactive solids was acquired based on the reported effort. Unfortunately, the technical gaps identified for Phase II of the LCL-CTM technology development could not all be eliminated and the transport of solids under high fuel load remained unstable at the Prototype scale. The nature of the iterative learning going back and forth between CFM and Prototype scale became cost-prohibitive and forced the project to pivot at a relatively late date in the project. The LCL-CTM process switched from a Transport reactor design to a Bubbling Fluidized Bed (BFB) design in order to successfully achieve all process criteria but at the 100-kWth scale to accommodate the residual funding. The CFM remains a very relevant tool for future LCL-CTM process development. While the LCL-CTM technology still must be demonstrated under scale up conditions (and the success of the BFB testing would push to scale up in that configuration), the CFM will remain a preferred tool for troubleshooting and reducing the technical gaps of LCL-CTM.

01 COAL, LIGNITE, AND PEAT↗

Building Assessment of Radon Reduction Interventions with Energy Retrofits Expansion (The BEX Study): Final Report

This report presents the findings from a study that was performed to assess whether current precautionary measures used by the US Department of Energy Weatherization Assistance Program (WAP) are effective for preventing indoor radon increases following weatherization. The study results show that current practices have produced substantial benefit compared to previous practices, and that there are no statistically significant changes in indoor radon levels on the lowest living levels with these practices following weatherization.

07 ISOTOPE AND RADIATION SOURCES↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant

A comprehensive front-end engineering design (FEED) study has been undertaken for a post-combustion capture (PCC) unit located at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in a full and unredacted FEED study report with all supporting documents, numbering over 150, also publicly available.

20 FOSSIL-FUELED POWER PLANTS↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

Full-scale FEED Study for Retrofitting the Prairie State Generating Station with an 816 MWe Capture Plant using Mitsubishi Heavy Industries Post-Combustion CO 2 Capture Technology

A full front-end engineering design (FEED) study to for a carbon capture system for Unit #2 (816 MWe) at the Prairie State Generating Company’s (PSGC) Energy Campus in Marissa, IL based on the KM CDR Process CO 2 capture technology from Mitsubishi Heavy Industries (MHI) using their proprietary solvent KS-21TM. If built this carbon capture plant would be the world's largest to date. The cost of capture of 100 percent of the plant emissions was calculated to be $43.42 per metric tonne of CO 2 based on levelized costs for 30 years of operation (85% capacity factor), and includes Interest on Debt and Return on Equity During Operation.

01 COAL, LIGNITE, AND PEAT↗

Large-Scale Commercial Carbon Capture Retrofit of the San Juan Generating Station

Enchant Energy, L.L.C. (Enchant) was selected to conduct a Front-End Engineering Design study (FEED) for the addition of a full-scale carbon capture system to remove carbon dioxide from the flue gas emissions of the two coal-fired generating units (total of 847 MW net) at San Juan Generating Station (SJGS), using Mitsubishi Heavy Industries Americas (MHIA) KM CDR Process™. Sargent & Lundy LLC (S&L) was selected as the primary technical lead, and along with various other organizations, were able to support Enchant’s completion of the following FEED tasks: Task 1 – Project Management & Planning; Task 2 – FEED Study; Task 3 - Final FEED Study Package. The FEED study period was between October 15, 2019 to September 30, 2022.

01 COAL, LIGNITE, AND PEAT↗

The Value Proposition for Cost-Effective, Demand Responsive-Enabling, Nonresidential Lighting System Retrofits in California Buildings

Commercial lighting represents a significant potential source of demand response (DR) for the electrical grid, via traditional load shedding and rapid-dispatch (fast-DR) ancillary services when DR is enabled by networked lighting controls (NLCs). However, despite the significant opportunity and a regulatory push, DR-enabled lighting is installed in relatively few buildings because most building owners do not recognize its strong value proposition. Although NLCs can reduce energy bills, optimize facilities, and increase revenue, these co-benefits are not well quantified. This project analyzed lighting DR resources and energy-related co-benefits for commercial buildings in California. Using more than 100,000 individual hourly load profiles, the team forecasted the potential DR resources likely available from commercial lighting in 2025 and estimated revenues available from participation of these DR resources in energy markets. Combining these results with field-study estimates for NLC installation costs and energy savings provided a detailed accounting of site-level cost and energy-related co-benefits by building type from NLC’s DR enablement. In many cases, energy savings alone can deliver significant net value, justifying NLC DR-enabled adoption. Additionally, the study considers the sometimes-larger non-energy benefits (NEBs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Facade Retrofits Modeling: Results and Documentation

Utilizing NREL's ResStock analysis tool and datasets, we performed an economic analysis for various facade upgrade combinations and strategies. This analysis considers the combined life-cycle cost of re-siding and window and insulation upgrades including both home value impacts and recurring bill savings estimates from a ResStock analysis, for varying years of home ownership.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗