Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

ATLAS jet trigger update for the LHC run II

The CERN Large Hadron Collider is the biggest and most powerful particle collider ever built. It produces up to 40 million proton-proton collisions per second at unprecedented energies to explore the fundamental laws and properties of Nature. The ATLAS experiment is one of the detectors that analyses and records these collisions. It generates dozens of GB/s of data that has to be reduced before it can be permanently stored, the event selection is made by the ATLAS trigger system, which reduces the data volume by a factor of 105. The trigger system has to be highly configurable in order to adapt to changing running conditions and maximize the physics output whilst keeping the output rate under control. A particularly interesting pattern generated during collisions consists of a collimated spray of particles, known as a hadronic jet. To retain the interesting jets and efficiently reject the overwhelming background, optimal jet energy resolution is needed. Therefore the Jet trigger software requires CPU-intensive reconstruction algorithms. In order to reduce the resources needed for the reconstruction step, a partial detector readout scheme was developed, which effectively suppresses the low activity regions of the calorimeter. In this paper we describe the overall ATLAS trigger software, and the jet trigger in particular, along with the improvements made on the system. We then focus on detailed studies of the algorithm timing and the performance impact of the full and partial calorimeter readout schemes. We conclude with an outlook of the jet trigger plans for the next LHC data-taking period. (authors)

43 PARTICLE ACCELERATORS↗

Search for New Physics in Top Quark Production and Upgrade of the CMS Hadron Calorimeter

Our goal is to measure precisely the properties of the heaviest subatomic particle ever discovered, the top quark. In the proton-proton collisions at the LHC, top quarks are produced copiously. The largest set of top quarks recorded by the CMS detector make it an ideal laboratory to measure properties such as its mass and the rate at which pair of top quarks are produced in association with energetic photons. Quantum electrodynamics, or QED, describes the emission of light by charged particles and is the most precise physics theory ever devised. Typically this means light emitted by electrons, but any charged particles will do, such as the top quark. Studies of the light-emitting properties of top quarks help us to refine our current theoretical predictions at the finest level, and provide additional tools to study in more detail the recently discovered Higgs boson particle. However, during this process, the studies may reveal interesting features not yet observed. Deviations from the standard predictions would be a strong sign of something entirely new. These new physics theories are motivated to answer the current big mysteries in the universe such as what is the nature of mass or what is dark matter. As the LHC increases the collision energy and its luminosity, the detectors need to be improved to cope with these high-luminosity scenarios. New sensors will be installed in the hadron calorimeter detectors along with new front and end electronics at the end of 2016. We are testing and calibrating the new front-end readout electronics that will allow us to have more options to reduce the noise on these detectors. In order to do this calibration, we have developed a system that can inject electric charge in the full range of the charge integrator chip, the QIE ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a quantum noise limited Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging

Purpose: Electronic Portal Imaging Devices (EPIDs) have been widely used in radiation therapy and are still needed on linear accelerators (Linacs) equipped with kilovoltage cone beam CT (kV-CBCT) or MRI systems. Our aim is to develop a new high quantum efficiency (QE) Čerenkov Portal Imaging Device (CPID) that is quantum noise limited at dose levels corresponding to a single Linac pulse. Methods: Recently a new concept of CPID for MV x-ray imaging in radiation therapy was introduced. It relies on Čerenkov effect for x-ray detection. The proposed design consisted of a matrix of optical fibers aligned with the incident x-rays and coupled to an active matrix flat panel imager (AMFPI) for image readout. A weakness of such design is that too few Čerenkov light photons reach the AMFPI for each incident x-ray and an AMFPI with an avalanche gain is required in order to overcome the readout noise for portal imaging application. In this work the authors propose to replace the optical fibers in the CPID with light guides without a cladding layer that are suspended in air. The air between the light guides takes on the role of the cladding layer found in a regular optical fiber. Since air has a significantly lower refractive index (∼1 versus 1.38 in a typical cladding layer), a much superior light collection efficiency is achieved. Results: A Monte Carlo simulation of the new design has been conducted to investigate its feasibility. Detector quantities such as quantum efficiency (QE), spatial resolution (MTF), and frequency dependent detective quantum efficiency (DQE) have been evaluated. The detector signal and the quantum noise have been compared to the readout noise. Conclusions: Our studies show that the modified new CPID has a QE and DQE more than an order of magnitude greater than that of current clinical systems and yet a spatial resolution similar to that of current low-QE flat-panel based EPIDs. Furthermore it was demonstrated that the new CPID does not require an avalanche gain in the AMFPI and is quantum noise limited at dose levels corresponding to a single Linac pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 7.4 kHz, 20-bit image encoder with a CMOS linear image sensor

This paper presents a unique CMOS linear image sensor for reading the pseudo-random code on the slit disc, focusing on the two aspects of low noise and readout rate. Each pixel is equipped with an exclusive integral readout circuit, and the shape of the pixel also matches the slit disc, making the output signal consistent by up to 99%. After subdivision, the absolute angle data can be captured with an angular resolution of 16 bits and a maximum speed of 7.4 kHz. In addition, decoding and subdivision methods are suitable for high-speed, inexpensive encoder systems.

42 ENGINEERING↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction effects and special advantages in electronic heterodyne moire deflectometry

Effects of diffraction on the performance of electronic heterodyne readout of moire fringes are investigated. The sensitivity, accuracy, and resolution of the system are calculated, and it is shown that these features are significantly improved compared with the conventional intensity moire readout technique. The sensitivity of the system can be tripled without changing the distance between gratings. The system was evaluated experimentally by measuring the refractive-index derivatives of a weak phase object consisting of a large KD(asterisk)P crystal. Effects of nonlinear fringe modulation were studied both theoretically and experimentally. It is shown that in this case the electronic phase is not linearly related to the fringe shift, and calibration of the system is necessary.

Stricker, J.↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the noise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

Johnson, Hans↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the n oise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-G-17A-01: Innovative High-Performance PET Imaging System for Preclinical Imaging and Translational Researches

Purpose: To develop a practical and compact preclinical PET with innovative technologies for substantially improved imaging performance required for the advanced imaging applications. Methods: Several key components of detector, readout electronics and data acquisition have been developed and evaluated for achieving leapfrogged imaging performance over a prototype animal PET we had developed. The new detector module consists of an 8×8 array of 1.5×1.5×30 mm{sup 3} LYSO scintillators with each end coupled to a latest 4×4 array of 3×3 mm{sup 2} Silicon Photomultipliers (with ∼0.2 mm insensitive gap between pixels) through a 2.0 mm thick transparent light spreader. Scintillator surface and reflector/coupling were designed and fabricated to reserve air-gap to achieve higher depth-of-interaction (DOI) resolution and other detector performance. Front-end readout electronics with upgraded 16-ch ASIC was newly developed and tested, so as the compact and high density FPGA based data acquisition and transfer system targeting 10M/s coincidence counting rate with low power consumption. The new detector module performance of energy, timing and DOI resolutions with the data acquisition system were evaluated. Initial Na-22 point source image was acquired with 2 rotating detectors to assess the system imaging capability. Results: No insensitive gaps at the detector edge and thus it is capable for tiling to a large-scale detector panel. All 64 crystals inside the detector were clearly separated from a flood-source image. Measured energy, timing, and DOI resolutions are around 17%, 2.7 ns and 1.96 mm (mean value). Point source image is acquired successfully without detector/electronics calibration and data correction. Conclusion: Newly developed advanced detector and readout electronics will be enable achieving targeted scalable and compact PET system in stationary configuration with >15% sensitivity, ∼1.3 mm uniform imaging resolution, and fast acquisition counting rate capability for substantially improved imaging and quantification performance for small animal imaging and image-guided radiotherapy applications. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Measurement of Neutron Multiplicity in Charged Current Neutrino Interactions on Oxygen

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located 100~meters downstream in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory (Fermilab). Its primary goals are to (1) measure the neutron yield from $\nu_\mu$ interactions as a function of momentum transfer $Q^2$ so that neutrino-nucleus interaction models can be better constrained, and (2) demonstrate the power of novel, fast-timing detectors with the first deployment of Large Area Picosecond PhotoDetectors (LAPPDs). Current knowledge of neutrino-nucleus interactions fall short in modeling the topologies of such interactions, leading to inaccurate reconstruction of event kinematics such as particle energy, direction, and vertex. As a consequence, the accuracy of cross section measurements is impacted, which is necessary for precise physics measurements. Neutrons are an indication of inelasticity and affect the determination of the energy of the parent neutrino. Quantifying the neutron yield is a step towards reducing the associated uncertainties, and thus improving our understanding of these complex interactions and benefiting the next generation of long-baseline neutrino experiments. ANNIE will make use of LAPPDs to measure neutron multiplicity of CC-0$\pi$ $\nu_\mu$ interactions on oxygen, making it the first experiment to deploy an array of these photodetectors. Because the LAPPD is a novel photodetection technology, much customization is required to integrate it into existing electronics. The first half of this thesis covers the significant progress made towards the first deployment of the LAPPD system. From its test stand at Fermilab, the LAPPD system was systematically tested and put together until deployment readiness was achieved. I present my contributions to the design, fabrication, and testing of the waterproof housing and cables, and the commissioning of the LVHV board that powers the LAPPD and its readout electronics. These efforts brought the LAPPD system significantly closer to deployment, and eventually first data. The second half of this thesis presents the vertex and energy reconstruction algorithms developed to analysis the beam data with PMT-only information. While much progress has been made towards the deployment of LAPPDs, with several in the detector tank, efforts to integrate the LAPPD datastream are in progress. Thus, I developed a ring edge detection technique using PMT data to fit the muon vertex and determine its energy. The analysis in this thesis finds average neutron yields of $\Bar{n}_{data} = 0.452 \pm 0.039 (\text{stat}) \pm 0.27 (\text{sys})$ for a selection of muon neutrino candidates in the fiducial volume of ANNIE and corrected with an averaged neutron detection efficiency. An equivalent analysis for simulated beam data results in an average neutron yield of $\Bar{n}_{MC} = 0.582 \pm 0.018 (\text{stat}) \pm 0.25 (\text{sys})$. Future work includes application of efficiency corrections at a positional level, quantification of all systematic uncertainties, and neutron multiplicity measurements with other event topologies.

43 PARTICLE ACCELERATORS↗

Development of a modular test system for the silicon sensor R&D of the ATLAS Upgrade

High Voltage CMOS sensors are a promising technology for tracking detectors in collider experiments. Extensive R&D studies are being carried out by the ATLAS Collaboration for a possible use of HV-CMOS in the High Luminosity LHC upgrade of the Inner Tracker detector. CaRIBOu (Control and Readout Itk BOard) is a modular test system developed to test Silicon based detectors. It currently includes five custom designed boards, a Xilinx ZC706 development board, FELIX (Front-End LInk eXchange) PCIe card and a host computer. A software program has been developed in Python to control the CaRIBOu hardware. CaRIBOu has been used in the testbeam of the HV-CMOS sensor AMS180v4 at CERN. Preliminary results have shown that the test system is very versatile. In conclusion, further development is ongoing to adapt to different sensors, and to make it available to various lab test stands.

43 PARTICLE ACCELERATORS↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorporation of sensing modalities into de novo designed fluorescence-activating proteins

Through the efforts of many groups, a wide range of fluorescent protein reporters and sensors based on green fluorescent protein and its relatives have been engineered in recent years. Here we explore the incorporation of sensing modalities into de novo designed fluorescence-activating proteins, called mini-fluorescence-activating proteins (mFAPs), that bind and stabilize the fluorescent cis -planar state of the fluorogenic compound DFHBI. We show through further design that the fluorescence intensity and specificity of mFAPs for different chromophores can be tuned, and the fluorescence made sensitive to pH and Ca 2+ for real-time fluorescence reporting. Bipartite split mFAPs enable real-time monitoring of protein–protein association and (unlike widely used split GFP reporter systems) are fully reversible, allowing direct readout of association and dissociation events. The relative ease with which sensing modalities can be incorporated and advantages in smaller size and photostability make de novo designed fluorescence-activating proteins attractive candidates for optical sensor engineering.

59 BASIC BIOLOGICAL SCIENCES↗

DUNE DAQ R&D integration in ProtoDUNE Single-Phase at CERN

The DAQ system of ProtoDUNE-SP successfully proved its design principles and met the requirements of the beam run of 2018. The technical design of the DAQ system for the DUNE experiment has major differences compared to the prototype due to different requirements placed on the detector, as well as a radically different location of operation. The single-phase prototype at CERN is a major integration facility for R&D aspects of the DUNE DAQ system. The facility allows for the exploration of additional data processing capabilities and optimization of the FELIX system, which is the chosen TPC readout solution for the DUNE single-phase detectors. One of the fundamental differences from the prototype is that the DUNE DAQ relies on self-triggering. Therefore, real-time processing of the data stream for hit and trigger primitive finding is essential for the requirement of continuous readout. The supernova burst trigger requires a large and fast buffering technique, where 3D XPoint persistent memory solutions are evaluated and integrated. In order to maximize resource utilization of the FELIX hosting servers, the elimination of the 100 Gb network communication stack is desired. This implies the design and development of a single-host application layer, which is a fundamental element of the self-triggering chain. This paper discusses the evaluation and integration of these developments for the DUNE DAQ, in the ProtoDUNE environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗