Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

ACCELERATED THERMAL AGING OF HARVESTED HYPALON JACKET FOR REMAINING USEFUL LIFE DETERMINATION AND DIAGNOSIS

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

Glass III, Samuel W.↗

INTER-LABORATORY RESULTS AND ANALYSES OF MINI-C(T) SPECIMEN TESTING OF AN IRRADIATED LINDE 80 WELD METAL

An irradiated low-upper-shelf Linde 80 weld metal has been tested by four laboratories as part of an inter-laboratory assessment of use of the miniature compact tension [mini-C(T)] test specimen for Master Curve fracture toughness evaluation following ASTM E1921. The preliminary results from each of the laboratories have been compiled and evaluated together to assess the validity and use of the mini-C(T) specimen for an irradiated reactor pressure vessel material which can exhibit ductile crack growth at low temperatures relative to cleavage initiation fracture toughness. The preliminary results from this mini-C(T) testing can also be compared to extensive specimen test results from larger C(T) specimens of the same irradiated material. Comparisons of the results from each of the laboratories and some inter-laboratory differences in the fracture testing are assessed. The evaluations indicate reasonable agreement between the mini-C(T) and larger specimen results, but the selection of test temperature and the number of test specimens needed to obtain reliable results are more difficult when testing a low-upper-shelf toughness material.

Server, W. L.↗

Self-powered Wireless Through-wall Data Communication for Nuclear Environments

In the nuclear industry, many vital components, such as spent fuel storage canisters and nuclear reactor pressure vessels (RPV), are entirely enclosed by metal and surrounded by thick concrete walls that manage the potentially harmful radiation and prevent release to the environment. Due to the casks’ long storage, monitoring temperature, pressure, radiation, humidity, structural health, etc., within these enclosed vessels is crucial to ensure the fuel containment safety and security. In this paper, a self-powered wireless through-wall data communication system for nuclear environments was designed. The whole package includes: a radiation energy harvester with power management; ultrasound wireless communication using high-temperature piezoelectric transducers; electronics modules for harvesting, sensing, and data transmission; and radiation shielding for electronics and sensors. The package is able to harvest tens to hundreds of mW power from a nuclear canister environment directly and provides a path forward for continuous monitoring of the dry cask for 50 years.

Wu, Yongjia↗

LWR Aging Management for Life Beyond 80

While several decades of materials degradation research enabled the current US fleet of Light Water Reactors (LWR) to plan to produce electrical power through extended operations up to 80 years of plant life, it now seems appropriate to evaluate what issues, methods, and timelines need to be considered to meet the expected electric power demands for life beyond eighty (LBE) years. To address these questions, it will be necessary to review the electrical capacity and the projected LWR fleet capacity including new builds and advanced reactors. This effort should begin with a materials degradation assessment focused on known and possible unknown issues using a reduced Expanded Materials Degradation Assessment [1], which was employed to identify knowledge gaps for a second license renewal (60-80 yrs.). The focus of the LBE assessment should include: Establishing a timeline to initiate assessments of possible materials aging issues and to ensure sufficient time to evaluate materials degradation research gaps; assessing components and materials to be evaluated, e.g., metals (reactor pressure vessels and alloys within and outside the pressure boundary), concrete, cables, as well as mitigation methods, advanced monitoring, and validation with ex-service materials; initiating a LBE research plan focused on developing an expanded mechanistic understanding of materials degradation and refined models through Codes and Standards evaluation for use by the nuclear industry; and maintaining and strengthening the nuclear materials human knowledge base to address new and as yet unknown degradation modes.

Chen, Xiang↗

ADDITIVE MANUFACTURING AND REGULATORY TESTING OF CANISTERS FOR SPENT NUCLEAR FUEL MANAGEMENT

The back end of the fuel cycle focuses on the interim storage, transportation, and final disposition of the spent nuclear fuel from nuclear reactors. Commercial light water nuclear power stations across the United States operate with fuel assemblies being irradiated for up to 6 years (planned) in the reactor pressure vessel. After their planned irradiation, the fuel assemblies are moved to a spent fuel pool within the facility complex. After the spent nuclear fuel is removed from the fuel pool, it is typically inserted into a welded metal canister that can be transferred between overpacks for storage, transportation and possibly disposal. Most dry storage systems being used by industry today use dual purpose canisters (DPCs), designed for use in storage and transportation overpacks, but not specifically designed for disposal. Triple purpose-canisters, designed for disposal in addition to storage and transportation, have also been researched. Traditional manufacturing methods for spent fuel canisters involve fusion welding along the length or circumference of the canister which results in high tensile residual stresses in the joint weld zone (WZ) and heat affected zone (HAZ). In this paper, spent fuel canister designs were printed by wire arc additive manufacturing (AM) using the 316L SS welding wire to demonstrate: 1. Feasibility of spent nuclear fuel canister fabrication using this advanced manufacturing method, 2. Dynamic response of the additive manufacture canister design when subjected to the federally mandated Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) physical tests for Type B packages. This paper will focus on the canister printing design and structural tests. The AM 3D printed design, regulatory testing, and post-test evaluation of the canister tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. One AM canister design was subjected to the penetration, free drop, and puncture test. Before and after the dynamic structural tests, the AM canister design was scanned with a handheld scanner to capture a 3D CAD geometry to compare to the 3D printed canister design in the deformed shape. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeated results of the deformed shape of the AM canister design.

Martinez, Oscar↗

Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reactor pond walls deposit investigation during dismantling MR reactor - 15028

Specialists of the NRC 'Kurchatov Institute' now carry out the dismantling of the multiloop research MR reactor. During this works the water level was decreased in the MR reactor pond on 4 meter. Dependence of exposure dose rate above the pond from deposits on the pond walls was confirmed. Detailed research of deposits on MR reactor pond walls was made, using α-, β-, γ- spectrometric methods. Correlation coefficients between concentration Pu and U radionuclides and concentration {sup 137}Cs and {sup 241}Am was calculated. The surface activity of the main dose-forming radionuclide {sup 137}Cs on the walls of the pond was measured. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Remediation of Irradiated Graphite Using Microorganisms Isolated from Oil Contaminated Soil - 19643

The deployment of nuclear energy globally is hindered by the fear cleared by nuclear reactor disasters such as the Chernobyl and Fukushima reactor meltdowns. Additionally, accumulation of radioactive waste globally will, in the near future, present a significant threat to humans and the environment. Notably, the majority of nuclear waste from the energy generation industry is generated as Low Level Waste (LLW) in which the small radioactive component renders the bulk of the waste unsuitable for conventional treatment and disposal. In the case of radioactive graphite, the small radioactive component comprising radiocarbon-14 (C-14) and metallic pollutants can be removed to allow safe disposal or reuse as of the graphite. In the current study, mixed-cultures of organisms isolated from oil contaminated sites showed potential of selective bioaccumulation of C-14 from a powdered C-12/C-14 graphite matrix. The study was conducted in a continuously mixed reactor (growth vessel) constructed from Pyrex panels (30 cm x 20 cm x 15 cm) with finely ground graphite as the principal carbon source (1500-2000 mg.L{sup -1}) and spikes of glucose (500 mg.L{sup -1} every 48 hours). The growth vessel was connected to a biofilter unit by submersible pump where particulate matter was isolated for further analysis. Results showed that approximately 68% more C-14 was released from ignited dry cells than from respiration product. C-14 accumulated in cells corrected using a trap filter system, with a marked decrease of C-14 in carbon dioxide than vegetative suspended cells in the main tank. The only mechanism that could account for the differential C-14 distribution between the liquid medium and cells was possible fractionation during uptake of carbon compounds. The discriminating factor suggested in this study is the kinetic isotope effect (KIE) which allows heavier atoms to have different affinities for reaction sites on catalysis and biocatalysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tensile Behavior of Inconel X750 Sheets: Effect of Heat Treatment

X-750 is a nickel-chromium based super alloy of usefulness in a wide variety of applications. Its excellent relaxation resistance is useful for high-temperature springs and bolts; it is utilized in gas turbines, rocket engines, nuclear reactors, pressure vessels, tooling, and aircraft structures. Its performance is similar to that of Inconel alloy 600 but it is made precipitation-hardenable by additions of aluminum and titanium. It has good resistance to corrosion and oxidation along with high tensile and creep-rupture properties at temperatures up to 700 deg. C. In this study, the tensile flow behavior of the alloy was studied by performing uniaxial tensile tests under a range of temperatures and at different strain rates. To assess the microstructure-mechanical property relationships in the alloy, microstructure analysis (through the use of electron microscopy and XRD analysis) was utilized post-experiment. This paper will however focus on reporting the tensile properties and temperature and strain rate effects on the as-received alloy vs. the heat-treated alloy. (authors)

36 MATERIALS SCIENCE↗

Adaptive, Active Learning, and Multifidelity Monte Carlo Methods in the MOOSE Stochastic Tools Module

MOOSE is an open-source computational platform for constructing multi-physics models and executing them in a massively parallel fashion. It has a stochastic tools module (STM) for forward/inverse uncertainty quantification (UQ) and surrogate modeling. This presentation details some recent developments to the STM with respect to the implementation of adaptive, active learning, and multifidelity Monte Carlo methods for forward UQ of computational models. Specifically, the adaptive Monte Carlo methods include Markov Chain Monte Carlo (MCMC)-driven algorithms like adaptive importance sampling and parallelized subset simulation for statistical QoI estimation, rare events analysis, and stochastic gradient-free optimization. The active learning methods include Gaussian Process (GP) surrogates and their training via Adam optimization, design of acquisition functions, and integration with samplers like Monte Carlo, adaptive importance, and parallelized subset simulation. These active learning methods are also designed to work in a batch mode, wherein, the required calls to the full computational model are executed in parallel whenever a user-specified batch size is met. The multifidelity methods in STM are broadly divided into two categories: hierarchical, where a defined hierarchy exists among the low-fidelity models, and peer, where all the low-fidelity models are treated equally. A GP surrogate is used to learn the differences between the low- and high-fidelity models in both multifidelity categories, and acquisition functions from the active learning classes are used to decide whether to rely on a low-fidelity model or call the expensive high-fidelity model. Alongside the software description and usage, applications are also presented to nuclear engineering computational models including a TRISO nuclear fuel particle, a reactor pressure vessel, and a heat-pipe microreactor.

97 MATHEMATICS AND COMPUTING↗

Preliminary Analysis of a Nuclear Grade Sandwich Composite for Transportable Micro-Reactor Shielding

Transportable microreactors pose a unique shielding challenge compared with conventional reactors. Many vendors are seeking to transport a microreactor to a site, operate it for a number of years, and then transport it to a secondary site. This involves ensuring the reactor has sufficient shielding during operations and post-irradiation transportation to ensure the safety of those around it, all while ensuring it can be transported via traditional means. This work examines the use of a nuclear grade sandwich composite (NGSC) which seeks to combine the reactor pressure vessel and biological shielding into a single unit. Through this work, it was determined that the NGSC was sufficient to adequately reduce neutron and gamma current exiting the structure to warrant further investigation as a potential shielding option for microreactors.

42 ENGINEERING↗

Accelerated Thermal Aging of Harvested Hypalon Jacket for Remaining Useful Life Determination and Diagnosis

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon™ cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to in-service degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

cable aging, cable insulation, Hypalon, second lic↗

Evaluation of Machine Learning Models for Automated Data Analysis in In-Service Nuclear Power Plant Inspections

The commercial nuclear power industry is facing a potential shortage of certified nondestructive evaluation (NDE) analysts to meet future in-service inspection demands. Automated data analysis (ADA) currently supports human inspectors in tasks such as eddy current evaluations for steam generator examinations. Machine learning (ML) systems are nearing the capability to pass performance demonstration tests for ultrasonic testing (UT) inspections of reactor pressure vessel upper head penetrations in nuclear power plants (NPPs). Current research and development is focused on assisted analysis (AA) of ADA versus fully automated examinations. This presentation will cover assessment of ML flaw detection on dissimilar metal weld (DMW) piping joints.

36 MATERIALS SCIENCE↗

Material Selection and Heat Transfer Model for PTUHS Device

The Path to Ultimate Heat Sink Device (PTUHS) is a passive safety system that utilizes a radiative heat transfer valve to control the rate at which heat is removed from a nuclear reactor pressure vessel (RPV) and dispersed into surrounding soil. The material selection for the PTUHS device is investigated, where the thermophysical properties are either maximized or minimized bases on what section of the PTUHS that material is being used for. Final recommendations of material choice are then presented. The heat transfer model of the PTUHS device is solved in ABAQUS, where a normal operating conditions and SCRAM conditions are solved. These temperature maps and heat flux of the system show the system's ability, where minimal heat is lost during normal operating conditions and system failure in a SCRAM scenario due to temperatures that were reached.

42 - ENGINEERING↗

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

THE IMPACT OF MATERIAL AND DESIGN CRITERIA ON THE ASSESSMENT OF NEGLIGIBLE CREEP

Two of the proposed High Temperature Gas Reactors (HTGRs) under consideration for a demonstration plant have the design object of avoiding creep effects during normal operation. The goal of negligible creep could have different interpretations depending upon what failure modes are considered and associated criteria for avoiding the effects of creep. This paper addresses the criteria for negligible creep in Subsection NH of Section III of the ASME B&PV Code, other international design codes and some currently suggested criteria modifications and their impact on permissible operating temperatures for various reactor pressure vessel materials. There are a number of other considerations for the selection of vessel material besides avoiding creep effects. Of particular interest for this review are (1) the material s allowable stress level and impact on wall thickness (the goal being to minimize required wall thickness) and (2) ASME Code approval (inclusion as a permitted material in the relevant Section and Subsection of interest) to expedite regulatory review and approval. The application of negligible creep criteria to two of the candidate materials, SA533 and Mod 9Cr-1Mo, and to a potential alternate, normalized and tempered 2 Cr-1Mo, are illustrated and the relative advantages and disadvantages are discussed.

2 Cr-1Mo normalized and tempered↗

Wireless, in-vessel neutron monitor for initial core-loading of advanced breeder reactors

An experimental wireless, in-vessel neutron monitor was developed to measure the reactivity of an advanced breeder reactor as the core is loaded for the first time to preclude an accidental critically incident. The environment is liquid sodium at a temperature of approx. 220 C, with negligible gamma or neutron radiation. With ultrasonic transmission of neutron data, no fundamental limitation was observed after tests at 230 C for 2000 h. The neutron sensitivity was approx. 1 count/s-nv, and the potential data transmission rate was approx. 10,000 counts/s.

Delorenzo, J. T.↗