A new era of nuclear test verification
The global network of sensors commissioned to monitor compliance with the Comprehensive Nuclear-Test-Ban Treaty has proven capable of that task and more.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The global network of sensors commissioned to monitor compliance with the Comprehensive Nuclear-Test-Ban Treaty has proven capable of that task and more.
IGR J17454−2919 is a hard X-ray transient discovered by INTEGRAL on 2014 September 27. We report on our 20 ks Chandra observation of the source, performed about five weeks after the discovery, as well as on INTEGRAL and Swift long-term monitoring observations.
Millions of cargo containers are transported across the United States border annually and are inspected for illicit radioactive material and contraband using a combination of passive radiation portal monitors (RPM) and high energy X-ray non-intrusive inspection (NII) systems. As detection performance is expected to vary with the material composition of cargo, characterizing the types of material present in cargo is important to national security. This work analyzes the passive radiation and dual energy radiography signatures from on RPM and two NII system, respectively. First, the cargos were analyzed to determine their ability to attenuate emissions from an embedded radioactive source. Secondly, dual-energy X-ray discrimination was used to determine the material composition and density of the cargos.
Space flight results in the exposure of astronauts to a mixed field of radiation composed of energetic particles of varying energies, and biological indicators of space radiation exposure provides a better understanding of the associated long-term health risks. Current methods of biodosimetry have employed the use of cytogenetic analysis for biodosimetry, and more recently the advent of technological progression has led to advanced research in the use of genomic and proteomic expression profiling to simultaneously assess biomarkers of radiation exposure. We describe here the technical advantages of the Luminex(TM) 100 system relative to traditional methods and its potential as a tool to simultaneously profile multiple proteins induced by ionizing radiation. The development of such a bioassay would provide more relevant post-translational dynamics of stress response and will impart important implications in the advancement of space and other radiation contact monitoring. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)
The high-frequency-peaked BL Lac PKS 2155-304 is one of the brightest and best-studied VHE {gamma}-ray sources in the southern hemisphere. The High Energy Stereoscopic System (H.E.S.S.) has monitored PKS 2155-304 in 2006 and a multi-wavelength campaign involving X-ray, optical and radio observatories was triggered by the detection of an active state in July 2006, followed by the detection of two extraordinary flares on July, 28th and 30th, with peak fluxes {approx}100 times the usual values. We present results from the spectral and flux variability analysis of the VHE and simultaneous X-ray observations with Chandra during the second flare, as well as the detailed evolution of the VHE flux of PKS 2155-304 observed by H.E.S.S. in 2006. A study of flux correlations in the different frequency ranges during the second flare and the adjacent nights is discussed. We also present an interpretation of the active state of PKS 2155-304 in the framework of synchrotron self-Compton emission.
Concentrations of hexavalent chromium in groundwater at the 100-BC reactor area, located on the U.S. Department of Energy's Hanford Site, exceed the State of Washington's surface water quality criterion of 10 μg/L. Groundwater discharge to the Columbia River is the primary pathway for contaminants to reach potential receptors. Additional monitoring was needed in order to make an informed decision about groundwater remediation. An array of 23 hypo-rheic sampling points (HSPs) was installed and monitored. The HSPs consist of stainless-steel tubing with 15-cm long mesh screens at depths ranging from 0.15 to 1 meter in the riverbed. The HSPs, which are fully submerged at all river stages, were installed and sampled from a boat using low-flow pumping. The HSPs provided permanent sampling points to obtain samples of hypo-rheic zone water. They were equally suitable for high-frequency sampling, with up to 48 samples collected from each HSP over a 4-day period, and long-term monitoring, with monthly grab samples collected over a 2-year period. The HSPs could be sampled at any river stage, which varied up to 3 meters daily and 4 meters seasonally. Pumping rates were kept low to ensure representative sampling and avoid hydraulic short-circuiting. Short-term increases in river stage did not suppress hexavalent chromium concentrations. Monthly sampling showed that hexavalent chromium concentrations and specific conductance did decline during periods of sustained, seasonally high river stage. Concentrations varied from <2 μg/L during high river stage to 25 μg/L during moderate to low river stage, compared to 50 to 60 μg/L in near-river monitoring wells. (authors)
A simple asynchronous mechanical light chopper, based on modification of a turbo-molecular pump, has been developed to extend the interval between light pulses in single bunch operation at the Photon Factory storage ring. A pulse repetition rate of 80 kHz was achieved using a cylinder rotating at 48000 rpm, with 100 slits of 80 {mu}m width. This allows absolute timing of particles up to 12.48 {mu}s instead of the single-bunch period of 624 ns. We have applied the chopper together with a light pulse monitor to measure multielectron coincidence spectra using a magnetic bottle time-of-flight electron spectrometer. With such a system, the electron energies are determined without any ambiguity, the folding of coincidence spectra disappears and the effect of false coincidences is drastically reduced.
Scintillation dosimetry with optical fiber readout [fiber optic dosimetry (FOD)] requires accurate measurement of light intensity. It is therefore vulnerable to loss of calibration if any changes occur in the efficiency of the optical pathway between the scintillator and the light detector. The authors show in this article that common types of errors that arise during clinical use for brachytherapy applications can be quantified using a light emitting diode to stimulate the scintillator, the so-called LED-FOD method, in an integrated and easy-to-use control unit that incorporates a compact peripheral component interconnect extension for instrumentation. Common sources of error include bending and mechanical compression of the fiber optic components and changes in the temperature of the scintillator. The authors show that the method can detect all the common errors studied in this work and that different types of errors can result in different correlations between the LED stimulated signal and the brachytherapy source signal. For a single-type error the LED-FOD can be used easily for system diagnosis and validation with the possibility to correct the dosimeter reading if the correlation between the LED stimulated signal and the brachytherapy source signal can be defined. For more complex errors, resulting from two or more errors occurring simultaneously, the LED-FOD method can also allow the clinician to make a judgment on the reliability of the dosimeter reading. This self-checking method can enhance the clinical robustness of the FOD for achieving accurate dose control.
Hexavalent chromium is of increasing concern worldwide because of its toxicity, mobility in aqueous media, and relative abundance in waste effluent from a variety of industrial processes. Some of that waste has reached groundwater aquifers. Because of these factors, the fate and transport of hexavalent chromium in aquifers is of great importance for evaluating risk to fresh water sources and to the biosphere, and for designing means for abatement or remediation. Conventional sampling and analysis of groundwater samples from wells is labor intensive and therefore budget limited. The result is inadequate temporal and spatial characterization of contaminant plumes with respect to rate of movement, concentrations, and contaminant flux. A submersible hexavalent chromium sensor designed for extended-term deployment and based on ultraviolet colorimetry has been developed and tested at the Hanford Site, Washington. Adaptation of the method for in situ measurements requires automatic correction for sample turbidity and pH for every measurement. Turbidity is compensated nephelometrically. A method for estimating sample pH based on absorbance measurements made using two different wavelengths is presented. (authors)
We wanted to compare the dosimetric difference and treatment efficiency of RapidArc and fixed gantry intensity-modulated radiotherapy treatment (IMRT) for multiple liver metastases. Computed tomography datasets of 10 patients were studied retrospectively. IMRT plans were generated using 5 fields and RapidArc using either 1 or 2 arcs. The dose distribution of planning target volume (PTV), organs at risk (OARs), and the normal tissue were compared. Monitor units and treatment time were scored to measure expected treatment efficiency. Both RapidArc and IMRT plans resulted in equivalent target coverage. There was no statistically significant difference for the maximum and the minimum dose of PTV. RapidArc plans achieved an improved conformity index compared with IMRT (RA1 = 1.68 {+-} 0.27, RA2 = 1.61 {+-} 0.25, IMRT = 1.80 {+-} 0.37). For OARs, all techniques respected planning objectives. RapidArc plans had a lower dose in V{sub 40} of small bowel than IMRT, but were higher in mean dose of kidneys. Concerning the V{sub 5}, V{sub 10}, and V{sub 15} of healthy tissue, RapidArc plans were higher than IMRT. However, the V{sub 20}, V{sub 25}, and V{sub 30} of healthy tissue in RapidArc plans were lower than IMRT. Monitor units per fraction of RapidArc plans were about 40% or 46% of IMRT. Compared with IMRT plans, treatment time of RapidArc plans were reduced by 60% or 70%. All techniques respected planning objectives. RapidArc showed statistical improvements in conformity index and healthy tissue sparing with uncompromised target coverage. This, in combination with fewer monitor units and short delivery time, can lead to clinically significant advances for the treatment of multiple liver metastases.
This report summarizes the data, including the cost parameters of the former iodine production facilities decommissioning project in Turkmenistan. Before the closure, these facilities were producing the iodine from the underground mineral water by the methods of charcoal adsorption. Balkanabat iodine and Khazar chemical plants' sites remediation, transportation and disposal campaigns main results could be seen. The rehabilitated area covers 47.5 thousand square meters. The remediation equipment main characteristics, technical solutions and rehabilitation operations performed are indicated also. The report shows the types of the waste shipping containers, the quantity and nature of the logistics operations. The project waste turnover is about 2 million ton-kilometers. The problems encountered during the remediation of the Khazar chemical plant site are discussed: undetected waste quantities that were discovered during the operational activities required the additional volume of the disposal facility. The additional repository wall superstructure was designed and erected to accommodate this additional waste. There are data on the volume and characteristics of the NORM waste disposed: 60.4 thousand cu.m. of NORM with total activity 1 439 x 10{sup 9} Bq (38.89 Ci) were disposed at all. This report summarizes the project implementation results, from 2009 to 15.02.2012 (the date of the repository closure and its placement under the controlled supervision), including monitoring results within a year after the repository closure. (authors)
We present HST/STIS time-series spectroscopy of the central star of the 'Cat's Eye' planetary nebula NGC 6543. Intensive monitoring of the UV lines over a 5.8 hr period reveals well-defined details of large-scale structure in the fast wind, which are exploited to provide new constraints on the rotation rate of the central star. We derive characteristics of the line profile variability that support a physical origin due to corotating interaction regions (CIRs) that are rooted at the stellar surface. The recurrence time of the observed spectral signatures of the CIRs is used to estimate the rotation period of the central star and, adopting a radius between 0.3 and 0.6 R{sub Sun} constrains the rotational velocity to the range 54 km s{sup -1} {<=} v{sub rot} {<=} 108 km s{sup -1}. The implications of these results for single star evolution are discussed based on models calculated here for low-mass stars. Our models predict a subsurface convective layer in NGC 6543 which we argue to be causally connected to the occurrence of structure in the fast wind.
Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)
The physical principles of passive and active methods of remote-sensing monitoring of radioactive substances and toxic chemicals in accidental emissions (leaks) at nuclear fuel cycle objects are examined. The analytical possibilities of the most sensitive methods of remote-sensing monitoring, which are based on the advances made in UV and microwave range radiometry, laser IR-absorption spectroscopy, laser-induced fluorescence, and laser spark emission spectrometry, are discussed. The prospects for the development of spectral methods of remote-sensing monitoring in different ranges are analyzed.
A special set-up for continuous measurements of radon exhalation rate from soil is presented. It was constructed at Laboratory of Radiometric Expertise, Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN), Krakow, Poland. Radon exhalation rate was determined using the AlphaGUARD PQ2000 PRO (Genitron) radon monitor together with a special accumulation container which was put on the soil surface during the measurement. A special automatic device was built and used to raise and lower back onto the ground the accumulation container. The time of raising and putting down the container was controlled by an electronic timer. This set-up made it possible to perform 4–6 automatic measurements a day. Besides, some additional soil and meteorological parameters were continuously monitored. In this way, the diurnal and seasonal variability of radon exhalation rate from soil can be studied as well as its dependence on soil properties and meteorological conditions.
As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)
Purpose: In proton therapy, it could be desirable to measure out-of-field fast neutron doses at critical locations near and outside the patient body. Methods: The working principle of a novel clinical neutron dose monitor is verified by MCNPX simulation. The device is based on a small PE moderator of just 5.5cm side length for easy handling covered with a thermal neutron suppression layer. In the simulation, a polystyrene phantom is bombarded with a standard proton beam. The secondary thermal neutron flux produced inside the moderator by the impinging fast neutrons from the treatment volume is estimated by pairs of α-Al2O3:C (TLD500) chips which are evaluated offline after the treatment either by TL or OSL methods. The first chip is wrapped with 0.5mm natural Gadolinium foil converting the thermal neutrons to gammas via (n,γ) reaction. The second chip is wrapped with a dummy material. The chip centers have a distance of 2cm from each other. Results: The simulation shows that the difference of gamma doses in the TLD500 chips is correlated to the mean fast neutron dose delivered to the moderator material. Different outer shielding materials have been studied. 0.5mm Cadmium shielding is preferred for cost reasons and convenience. Replacement of PE moderator material by other materials like lead or iron at any place is unfavorable. The spatial orientation of the moderator cube is uncritical. Using variance reduction techniques like splitting/Russian roulette, the TLD500 gamma dose simulation give positive differences up to distances of 0.5m from the treatment volume. Conclusion: Applicability and basic layout of a novel clinical neutron dose monitor are demonstrated. The monitor measures PE neutron doses at locations outside the patient body up to distances of 0.5m from the treatment volume. Tissue neutron doses may be calculated using neutron kerma factors.