At least 667 records · Page 37

Stochastic effects during the action of the pump noise on bistable self-modulation oscillations in a solid-state ring laser

Nonlinear radiation dynamics of a solid-state ring laser is studied in the region of laser parameters corresponding to the parametric resonance between the self-modulation and relaxation oscillations. Bistable regions are found in which, apart from the self-modulation regime of the first kind, a stable quasi-periodic self-modulation regime exists. Temporal and spectral emission parameters of counterpropagating waves are considered in the bistable self-modulation generation regimes. The effect of noise on the bistable self-modulation oscillations is studied. It is shown that during the interaction of noise, spectral peaks split at relaxation and self-modulation frequencies. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A brief review of intermediate controlled nuclear syntheses (ICNS) without harmful radiations

Hadronic mechanics gave birth to new magnecular fuels. The present day demand is of clean energy source that is cheap and abundant. Clean energy can be obtained by harnessing renewable energy sources like solar, wind etc. Nuclear energy conventionally produced by fission reactions emits hazardous radiation and radioactive waste. The requirements of clean and safe energy gets fulfilled by novel fuel that achieved by elevating the traditional quantum mechanics to hadronic mechanics and to hadronic chemistry. In the present paper, a comprehensive review on both the theoretical and experimental aspect of the Intermediate Controlled Nuclear Synthesis (ICNS) as developed by Italian American Scientist Professor R. M. Santilli.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Binders for Thermal-Control Coatings

Methyl trialkoxysilane hydrolysates have been found to be superior binders for radiative thermal-control coatings. Using sprayed test panels, candidate coating formulations were optimized with respect to binder/ pigment radio, ethanol content, pigment particle size, coating thickness, and curing conditions. Binders are made from monomers of trialkoxy-silanes or chain-extended alkoxysilanes. Monomers are believed to polymerize to ladder-type structures like methyl silicone.

Patterson, W. J.↗

Cratering Equations for Zinc Orthotitanate Coated Aluminum

The final STS-125 servicing mission (SM4) to the Hubble Space Telescope (HST) in May of 2009 saw the return of the 2nd Wide Field Planetary Camera (WFPC2) aboard the shuttle Discovery. This hardware had been in service on HST since it was installed during the SM1 mission in December of 1993 yielding one of the longest low Earth orbit exposure times (15.4 years) of any returned space hardware. The WFPC2 is equipped with a 0.8 x 2.2 m radiator for thermal control of the camera electronics (Figure 1). The space facing surface of the 4.1 mm thick aluminum radiator is coated with Z93 zinc orthotitanate thermal control paint with a nominal thickness of 0.1 0.2 mm. Post flight inspections of the radiator panel revealed hundreds of micrometeoroid/orbital debris (MMOD) impact craters ranging in size from less than 300 to nearly 1000 microns in diameter. The Z93 paint exhibited large spall areas around the larger impact sites (Figure 2) and the craters observed in the 6061-T651 aluminum had a different shape than those observed in uncoated aluminum. Typical hypervelocity impact craters in aluminum have raised lips around the impact site. The craters in the HST radiator panel had suppressed crater lips, and in some cases multiple craters were present instead of a single individual crater. Humes and Kinard observed similar behavior after the WFPC1 post flight inspection and assumed the Z93 coating was acting like a bumper in a Whipple shield. Similar paint behavior (spall) was also observed by Bland2 during post flight inspection of the International Space Station (ISS) S-Band Antenna Structural Assembly (SASA) in 2008. The SASA, with similar Z93 coated aluminum, was inspected after nearly 4 years of exposure on the ISS. The multi-crater phenomena could be a function of the density, composition, or impact obliquity angle of the impacting particle. For instance, a micrometeoroid particle consisting of loosely bound grains of material could be responsible for creating the multiple craters. Samples were obtained from the HST largest craters for examination by electron microscope equipped with x-ray spectrometers to determine impactor source (micrometeoroid or orbital debris). In an attempt to estimate the MMOD particle diameters that produced these craters, this paper will present equations for spall diameter, crater depth and crater diameter in Z93 coated aluminum. The equations will be based on hypervelocity impact tests of Z93 painted aluminum at the NASA White Sands Test Facility. Equations inputs for velocities beyond the testable regime are expected from hydrocode simulations of Z93 coated aluminum using CTH and ANSYS AUTODYN.

Hyde, James↗

A boundary element approach to optimization of active noise control sources on three-dimensional structures

This paper presents the theoretical development of an approach to active noise control (ANC) applicable to three-dimensional radiators. The active noise control technique, termed ANC Optimization Analysis, is based on minimizing the total radiated power by adding secondary acoustic sources on the primary noise source. ANC Optimization Analysis determines the optimum magnitude and phase at which to drive the secondary control sources in order to achieve the best possible reduction in the total radiated power from the noise source/control source combination. For example, ANC Optimization Analysis predicts a 20 dB reduction in the total power radiated from a sphere of radius at a dimensionless wavenumber ka of 0.125, for a single control source representing 2.5 percent of the total area of the sphere. ANC Optimization Analysis is based on a boundary element formulation of the Helmholtz Integral Equation, and thus, the optimization analysis applies to a single frequency, while multiple frequencies can be treated through repeated analyses.

Cunefare, K. A.↗

Tumor Location, Interval Between Surgery and Radiotherapy, and Boost Technique Influence Local Control After Breast-Conserving Surgery and Radiation: Retrospective Analysis of Monoinstitutional Long-Term Results

Purpose: To obtain long-term data on local tumor control after treatment of invasive breast cancer by breast-conserving surgery and adjuvant radiotherapy (RT), in consideration of the interstitial high-dose-rate boost technique. Patients and Methods: A total of 263 women with 268 mammary carcinomas (International Union Against Cancer Stage I-IIB) who had undergone breast-conserving surgery and adjuvant RT between 1990 and 1994 were included. The potential risk factors for local recurrence-free survival were investigated. Results: During a median follow-up period of 94 months, 27 locoregional recurrences, 25 of which were in breast, were diagnosed. The cumulative rate of in-breast recurrence was 4.1% {+-} 1.4% at 5 years of follow-up and 9.9% {+-} 2.4% at 10 years. The multivariate analysis identified medial tumor location and delayed RT (defined as an interval of >2 months between surgery and the start of RT) as significant risk factors for in-breast recurrence in the overall study population. Medial tumor location vs. lateral/central location (hazard ratio, 2.48; 95% confidence interval, 1.06-5.84) resulted in a cumulative in-breast recurrence rate of 22.5% {+-} 8.3% vs. 6.9% {+-} 2.3% at 10 years. Delayed RT (hazard ratio, 2.84; 95% confidence interval, 1.13-7.13) resulted in a cumulative in-breast recurrence rate of 18.5% {+-} 6.2% vs. 6.8% {+-} 2.4% at 10 years. The multivariate analysis also showed that the risk of in-breast recurrence was lower after high-dose-rate boost therapy than after external beam boost therapy in patients with laterally/centrally located tumors (hazard ratio, 3.25; 95% confidence interval, 0.91-11.65). Conclusion: Tumor location, interval between surgery and RT, and boost technique might influence local control of breast cancer treated by breast-conserving surgery and RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a Dose-Control Relationship for Lung and Liver Tumors After Stereotactic Body Radiation Therapy

Purpose: To determine prognostic factors for local control of primary or metastatic tumors within the lung or liver treated with stereotactic body radiation therapy (SBRT) within a single institution. Methods and Materials: The records of 141 consecutive patients with 246 lesions treated with three-fraction SBRT from Oct 1999 through Aug 2005 were reviewed. Local control was assessed radiographically. Univariate and multivariate analyses were performed to evaluate the influence of the following factors on local control: total dose, expressed as either nominal prescription dose or equivalent uniform dose (EUD); gross tumor volume; primary site; treatment site (lung vs. other); histologic characteristics (adenocarcinoma vs. other); gender; age; and primary vs. metastatic tumor. Results: On univariate analysis, increased dose (either nominal or EUD) and smaller gross tumor volume were significant predictors of higher local control. Lesions treated to a nominal dose of 54 Gy or greater had a 3-year actuarial local control rate of 89.3% compared with 59.0% and 8.1% for those treated to 36-53.9 Gy and less than 36 Gy. On multivariate analysis, only increased nominal dose and EUD retained statistical significance. Treatment was well tolerated; 5.7% of patients experienced Grade 3 or higher toxicity. Conclusions: This large single-institution series suggests a dose-control relationship within the range of SBRT doses applied. Excellent local control rates are achieved with a nominal dose of 54 Gy or greater, corresponding to an EUD greater than 65.3 Gy. These results support the use of aggressive SBRT regimens when durable tumor control is the primary objective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonuniform transverse distribution of the light intensity and polarisation upon sum-frequency generation from the surface of an isotropic gyrotropic medium in the case of normal incidence of light

Sum-frequency generation from the surface of an isotropic gyrotropic medium by two normally incident homogeneously elliptically polarised Gaussian beams is studied theoretically. Analytic expressions, completely describing the transverse spatial distribution of the intensity and polarisation in the cross section of the reflected beam at the sum frequency, were derived taking into account both the local and nonlocal contributions of the quadratic nonlinearity of the medium thicknesses and the nonlinear contribution of its surface. It is shown that a special selection of the parameters of the fundamental waves allows one to determine components of the surface susceptibility tensor. (special issue devoted to the 80th birthday of S.A. Akhmanov)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the multi-scattered solar radiation from a leaf canopy for use in climate models

The terrestrial component of climate models requires computationally efficient algorithms for determining the multi-scattered radiation contributing to its heating from solar radiation. Much of the vegetated land cover has strong 3D controls on its radiation. The scattering from a 3D object of isotropic scatters is formulated abstractly and an approach to solution is described in the context of a spherical object. A Laplace integral representation of the 3D integral equation for radiative transfer is discretized. Such discretization provides the solution in terms of solutions to 3D Helmholtz equations, a single such equation in the lowest order approach. A Green's function approximate solution along the paths of entering and exiting radiation is integrated over such radiation for the paths assumed to coincide except for direction. The resulting approximate description of multi-scattered radiation corresponds to replacing the 3D scattering paths with a 1D path with attenuation amplified by a diffusivity factor. This description combines with previously derived analytic solutions for single scattered radiation to provide an efficient representation of the bidirectional scattering from the 3D object, intended for use in climate models and remote sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the phase difference of coupling coefficients of counterpropagating waves on relaxation oscillations in the self-modulation regime of a solid-state ring laser

The effect of the phase difference of the coupling coefficients on relaxation frequencies in the emission spectrum of a solid-state ring laser operating in the self-modulation regime of the first kind is studied theoretically. A strong dependence of one of the frequencies of relaxation oscillations on the phase difference of coupling coefficients is found. The stability of the self-modulation regime is studied analytically. (control of laser radiation parameters)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Loop laser cavities with self-pumped phase-conjugate mirrors in low-gain active media for phase-locked multichannel laser systems

It is proved that lasers with different loop cavities with self-pumped phase-conjugate mirrors in low-gain active media can operate under injection of external laser radiation and can be used for the development of diode-pumped phase-locked multichannel neodymium laser systems operating both on the fundamental laser transition with the wavelength {lambda} = 1.06 {mu}m and on the transition with {lambda} = 1.34 {mu}m. The phase-conjugate oscillation thresholds in the case of injection of an external signal are determined for a multiloop cavity configuration and an increased number of active elements in the cavity. It is shown that phase-conjugate oscillation can occur even if the single-pass gain of the active element is as low as only {approx}2. Under high-power side diode pumping of a multiloop Nd:YAG laser, single-mode output radiation was achieved at {lambda} = 1.064 {mu}m with a pulse energy up to 0.75 J, a pulse repetition rate up to 25 Hz, an average power up to 18.3 W, and an efficiency up to 20%. In a multiloop Nd:YAG laser with three active elements in the cavity, single-mode radiation at {lambda} = 1.34 {mu}m was obtained with a pulse energy up to 0.96 J, a pulse repetition rate up to 10 Hz, and an average power up to 8.5 W. (control of laser radiation parameters)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method and Apparatus for the Portable Identification Of Material Thickness And Defects Along Uneven Surfaces Using Spatially Controlled Heat Application

A method and apparatus for testing a material such as the water-wall tubes in boilers includes the use of a portable thermal line heater having radiation shields to control the amount of thermal radiation that reaches a thermal imager. A procedure corrects for variations in the initial temperature of the material being inspected. A method of calibrating the testing device to determine an equation relating thickness of the material to temperatures created by the thermal line heater uses empirical data derived from tests performed on test specimens for each material type, geometry, density, specific heat, speed at which the line heater is moved across the material and heat intensity.

Reilly, Thomas L.↗

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the zinc-oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 yr in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent Sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.↗

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the zinc-oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 yr in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent Sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.↗

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the Zinc Oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuum reflectance technique. The dose applied to the paints was approximately equivalent to 5 years in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuum reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectanc6 recovery after an additional 190 Equivalent Sun Hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.↗

Quality Control of Involved Field Radiotherapy in Patients With Early-Favorable (HD10) and Early-Unfavorable (HD11) Hodgkin's Lymphoma: An Analysis of the German Hodgkin Study Group

Purpose: The German Hodgkin Study Group (GHSG) set up a radiotherapy (RT) reference center within the Department of Radiation Oncology at University of Cologne to undertake quality assurance of the group's clinical studies. In the HD10 trial (early-favorable stages) and HD11 trial (early-unfavorable stages) all patients received involved field (IF)-RT (30 Gy vs. 20 Gy) within a combined-modality approach. For these patients a central prospective review of all diagnostic imaging was performed by expert radiation oncologists to control disease extension and to define IF treatment volume. Methods and Materials: On the basis of simulation films, verification films, and radiotherapy case report form (CRF) an expert panel evaluated retrospectively the adequacy of irradiated IF treatment portals according to the RT prescription, applied radiation doses, treatment time, and technical parameters. Results: Between 1999 and 2006 a total of 825 of 1370 randomized patients of the HD10 trial (60%) and 954 of 1422 patients of the HD11 trial (67%) were evaluated by the panel. Radiotherapy was rated as suboptimal in 47% of all reviewed cases. Although the participating RT centers received a precise RT prescription, most difficulties occurred in the adequate coverage of the IF (40%), followed by technical faults (12%). Deviations from the prescribed single daily dose (1.8-2 Gy), weekly dose, and total reference dose were rare (1%). Conclusions: As a consequence of these findings, radiation oncologists were trained on the definition of IF-RT at GHSG meetings and at the annual meetings of the German Society for Therapeutic Radiation Oncology. Possible correlations between RT quality and relapse rate will be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗