Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum Error Correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Information storage capacity of discrete spin systems

Understanding the limits imposed on information storage capacity of physical systems is a problem of fundamental and practical importance which bridges physics and information science. There is a well-known upper bound on the amount of information that can be stored reliably in a given volume of discrete spin systems which are supported by gapped local Hamiltonians. However, all the previously known systems were far below this theoretical bound, and it remained open whether there exists a gapped spin system that saturates this bound. Here, we present a construction of spin systems which saturate this theoretical limit asymptotically by borrowing an idea from fractal properties arising in the Sierpinski triangle. Our construction provides not only the best classical error-correcting code which is physically realizable as the energy ground space of gapped frustration-free Hamiltonians, but also a new research avenue for correlated spin phases with fractal spin configurations. -- Highlights: •We propose a spin model with fractal ground states and study its coding properties. •We show that the model asymptotically saturates a theoretical limit on information storage capacity. •We discuss its relations to various theoretical physics problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full-Zone Spin Splitting for Electrons and Holes in Bulk GaAs and GaSb

The spin-orbit interaction--a fundamental electroweak force--is equivalent to an effective magnetic field intrinsic to crystals, leading to band spin splitting for certain k points in sufficiently low-symmetry structures. This (Dresselhaus) splitting has usually been calculated at restricted regions in the Brillouin zone via small wave vector approximations (e.g., k {center_dot} p), potentially missing the 'big picture'. We provide a full-zone description of the Dresselhaus splitting in zinc blende semiconductors by using pseudopotentials, empirically corrected to rectify local density approximation errors by fitting GW results. In contrast to what was previous thought, we find that the largest spin splitting in the lowest conduction band and upper valence band (VB1) occurs surprisingly along the (210) direction, not the (110) direction, and that the splitting of the VB1 is comparable to that of the next two valence bands VB2 and VB3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperfine interactions for small systems including transition-metal elements using self-interaction corrected density-functional theory

The interactions between the electronic magnetic moment and the nuclear spin moment, i.e., magnetic hyperfine (HF) interactions, play an important role in understanding electronic properties of magnetic systems and in realizing platforms for quantum information science applications. We investigate the HF interactions for atomic systems and small molecules, including Ti or Mn, by using Fermi–Löwdin orbital (FLO) based self-interaction corrected (SIC) density-functional theory. We calculate the Fermi contact (FC) and spin-dipole terms for the systems within the local density approximation (LDA) in the FLO-SIC method and compare them with the corresponding values without SIC within the LDA and generalized-gradient approximation (GGA), as well as experimental data. For the moderately heavy atomic systems (atomic number Z ≤ 25), we find that the mean absolute error of the FLO-SIC FC term is about 27 MHz (percentage error is 6.4%), while that of the LDA and GGA results is almost double that. Therefore, in this case, the FLO-SIC results are in better agreement with the experimental data. For the non-transition-metal molecules, the FLO-SIC FC term has the mean absolute error of 68 MHz, which is comparable to both the LDA and GGA results without SIC. For the seven transition-metal-based molecules, the FLO-SIC mean absolute error is 59 MHz, whereas the corresponding LDA and GGA errors are 101 and 82 MHz, respectively. Therefore, for the transition-metal-based molecules, the FLO-SIC FC term agrees better with experiment than the LDA and GGA results. We observe that the FC term from the FLO-SIC calculation is not necessarily larger than that from the LDA or GGA for all the considered systems due to the core spin polarization, in contrast to the expectation that SIC would increase the spin density near atomic nuclei, leading to larger FC terms.

Chemistry↗

Witnessing entanglement in phase space using inefficient detectors

We propose a scheme for witnessing entanglement in phase space by significantly inefficient detectors. The implementation of this scheme does not require any additional process for correcting errors, in contrast to previous proposals. Moreover, it allows us to detect entanglement without full a priori knowledge of the detection efficiency. It is shown that entanglement in single-photon entangled and two-mode squeezed states can be witnessed with detection efficiency as low as 40%. Our approach enhances the possibility of witnessing entanglement in various physical systems using current detection technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Differential spectral responsivity measurement of photovoltaic detectors with a light-emitting-diode-based integrating sphere source

We present an experimental realization of differential spectral responsivity measurement by using a light-emitting diode (LED)-based integrating sphere source. The spectral irradiance responsivity is measured by a Lambertian-like radiation field with a diameter of 40mm at the peak wavelengths of the 35 selectable LEDs covering a range from 280 to 1550nm. The systematic errors and uncertainties due to lock-in detection, spatial irradiance distribution, and reflection from the test detector are experimentally corrected or considered. In addition, we implemented a numerical procedure to correct the error due to the broad spectral bandwidth of the LEDs. The overall uncertainty of the DSR measurement is evaluated to be 2.2% (k=2) for Si detectors. To demonstrate its application, we present the measurement results of two Si photovoltaic detectors at different bias irradiance levels up to 120mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependence of calculated postshock thermodynamic variables on vibrational equilibrium and input uncertainty

The purpose of this article is to explore the dependence of calculated postshock thermodynamic properties in shock tube experiments upon the vibrational state of the test gas and upon the uncertainties inherent to calculation inputs. This paper first offers a comparison between state variables calculated according to a Rankine–Hugoniot–equation-based algorithm, known as FROSH, and those derived from shock tube experiments on vibrationally nonequilibrated gases. It is shown that incorrect vibrational relaxation assumptions could lead to errors in temperature as large as 8% for 25% oxygen/argon mixtures at 3500 K. Following this demonstration, this article employs the algorithm to show the importance of correct vibrational equilibration assumptions, noting, for instance, that errors in temperature of up to about 2% at 3500 K may be generated for 10% nitrogen/argon mixtures if vibrational relaxation is not treated properly. Lastly, this article presents an extensive uncertainty analysis, showing that postshock temperatures can be calculated with root-of-sum-of-square errors of better than ±1% given sufficiently accurate experimentally measured input parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hadronic contributions to (g - 2) µ

The Muon g-2 Experiment at Fermilab, which recently started running, plans to reduce the uncertain- ties on the already very precisely measured anomalous magnetic moment of the muon by a factor of four. The goal of this effort is to probe the observed difference of more than three standard deviations between Standard-Model theory and experiment, one of the few persistent hints for physics beyond the Standard Model. The Fermilab experiment collected data from their first run last year with statistics comparable to BNL E821. They expect to release the measurement result in 2019. On the theoretical side, because the muon g - 2 arises from quantum- mechanical loop contributions in the Standard Model, it is sensitive to virtual effects of new particles, and places important constraints on Standard-Model extensions. To leverage the anticipated reduction in experimental errors, and determine unambiguously whether or not new-physics effects contribute to this quantity, the theoretical errors must be made more reliable and reduced to a commensurate precision. The Muon g-2 Theory Initiative was created to facilitate this development. The dominant sources of uncertainty in the Standard-Model prediction of the muon g -2 are from the hadronic contributions. The hadronic vacuum polarization (HVP) provides the leading correction followed by hadronic light-by-light (HLbL) scattering. There are a number of complementary theoretical efforts underway to better understand and quantify these contributions, including dispersive and data driven methods, lattice QCD, and effective field theories. Given the precision goals and the phenomenological importance, it is important to have more than one independent method for each of the two hadronic corrections, each with fully quantified uncertainties. Fostering the development of such methods is a prime goal of the initiative, as this will enable critical cross checks, and, upon combination, may yield gains in precision, to maximize the impact of E989. An important aspect of the Muon g-2 Theory Initiative’s activities are providing platforms that facilitate interactions between the different groups, as well as between the theoretical and experimental g - 2 communities. To this end, several workshops were organized in 2017 and 2018. The first meeting, held at Fermilab (June 3–6, 2017, St. Charles, IL, USA), served to kick-off the Initiative’s activities. Two meetings in early 2018 were focused respectively on the HVP and HLbL corrections. The HVP meeting was held at KEK (February 12–14, 2018, Tsukuba, Japan) and the HLbL meeting at the University of Connecticut (March 12–14, 2018, Storrs, CT, USA). The most recent workshop, which served as the second plenary meeting of the Initiative, was held at the University of Mainz (June 18–22, 2018, Mainz, Germany). An important outcome of these meetings are concrete plans for a first white paper, which is currently being written. We aim to post the white paper just prior to the release of the first E989 measurement, to present a clean theoretical prediction. The first white paper is focused on assessing and improving the reliability of the SM prediction. The purpose of the INT workshop in September 2019 is to start the next stage of the Initiative, focusing on the development of strategies to improve the theory uncertainties beyond the current level towards the E989 precision goal. We aim to accelerate theoretical developments on the hadronic contributions to the muon g - 2 so that the Standard-Model theory error can be brought to the needed precision, again in advance of the next release from E989. Hence the workshop will provide crucial theory support for a US experiment with broad impact. The Muon g-2 Theory Initiative relies on input from representatives of all the different communities that are engaged in this effort. It is therefore important that all these areas are properly represented. The funds from this grant will be used to enable more people, especially early-career scientists, to participate and make essential contributions to the workshop discussions. Since the workshop’s main goal is to kick-off the next stage of the theory initiative’s activities, support for this workshop from the DOE will help the theory community provide crucial theoretical support to the Fermilab Muon g-2 Experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate Electron Affinities and Orbital Energies of Anions from a Nonempirically Tuned Range-Separated Density Functional Theory Approach

The treatment of atomic anions with Kohn–Sham density functional theory (DFT) has long been controversial because the highest occupied molecular orbital (HOMO) energy, E HOMO , is often calculated to be positive with most approximate density functionals. We assess the accuracy of orbital energies and electron affinities for all three rows of elements in the periodic table (H–Ar) using a variety of theoretical approaches and customized basis sets. Among all of the theoretical methods studied here, we find that a nonempirically tuned range-separated approach (constructed to satisfy DFT-Koopmans’ theorem for the anionic electron system) provides the best accuracy for a variety of basis sets, even for small basis sets where most functionals typically fail. Previous approaches to solve this conundrum of positive E HOMO values have utilized non-self-consistent methods; however, electronic properties, such as electronic couplings/gradients (which require a self-consistent potential and energy), become ill-defined with these approaches. In contrast, the nonempirically tuned range-separated procedure used here yields well-defined electronic couplings/gradients and correct E HOMO values because both the potential and resulting electronic energy are computed self-consistently. Orbital energies and electron affinities are further analyzed in the context of the electronic energy as a function of electronic number (including fractional numbers of electrons) to provide a stringent assessment of self-interaction errors for these complex anion systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Translating Non-Trivial Algorithms from the Circuit Model to the Measurement

We provide a set of prescriptions for implementing a circuit model algorithm as measurement based quantum computing via a large discrete cluster state constructed sequentially, from qubits implemented as single photons. We describe a large optical discrete graph state capable of searching logical 4 and 8 element lists as an example. To do so we have developed several prescriptions based on analytic evaluation of the evolution of discrete cluster states and graph state equations. We describe the cluster state as a sequence of repeated entanglement and measurement steps using a small number of single photons for each step. These prescriptions can be generalized to implement any logical circuit model operation with appropriate single photon measurements and feed forward error corrections. Such a cluster state is not guaranteed to be optimal (i.e. minimum number of photons, measurements, run time).

Smith, IV, Amos M↗

Combined Quantum Chemical/Raman Spectroscopic Analyses of Li+ Cation Solvation: Cyclic Carbonate Solvents - Ethylene Carbonate and Propylene Earbonate

Combined computational/Raman spectroscopic analyses of ethylene carbonate (EC) and propylene carbonate (PC) solvation interactions with lithium salts are reported. It is proposed that previously reported Raman analyses of (EC)n-LiX mixtures have utilized faulty assumptions. In the present studies, density functional theory (DFT) calculations have provided corrections in terms of both the scaling factors for the solvent's Raman band intensity variations and information about band overlap. By accounting for these factors, the solvation numbers obtained from two different EC solvent bands are in excellent agreement with one another. The same analysis for PC, however, was found to be quite challenging. Commercially available PC is a racemic mixture of (S)- and (R)-PC isomers. Based upon the quantum chemistry calculations, each of these solvent isomers may exist as multiple conformers due to a low energy barrier for ring inversion, making deconvolution of the Raman bands daunting and inherently prone to significant error. Thus, Raman spectroscopy is able to accurately determine the extent of the EC...Li+ cation solvation interactions using the provided methodology, but a similar analysis of PC...Li+ cation solvation results in a significant underestimation of the actual solvation numbers.

CARBONIC ACID ESTERS↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

Measuring the angular momentum of a neutron using Earth's rotation

A coupling between Earth's rotation and orbital angular momentum (OAM), known as the Sagnac effect, is observed in entangled neutrons produced using a spin-echo interferometer. After correction for instrument systematics the measured coupling is within 5% of theory, with an uncertainty of 7.2%. The OAM in our setup is transverse to the propagation direction and scales linearly with neutron wavelength (4–12.75 Å), so the Sagnac coupling can be varied without mechanically rotating the device, which avoids systematic errors present in previous experiments. The detected transverse OAM of our beam corresponds to 4098 ± 295 ℏ Å − 1 , 10 5 times lower than in the previous neutron experiments. This demonstrates the feasibility of using the Sagnac effect to definitively measure neutron OAM and paves the way towards a future observation of the quantum Sagnac effect. Published by the American Physical Society 2025

Geerits, Niels (ORCID:0000000248072084)↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-201-04: Clinical Protocol for Reuse of Optically Stimulated Luminescence Detectors

Purpose: OSLDs made of Al2O3:C have many useful dosimetric characteristics including their ability to be reused. The signal on an OSLD can be removed through heat or light. The objective of this study was to characterize the change in sensitivity associated with annealing OSLDs with light and in doing so define a range through which reuse is viable. Methods: Four groups of nanoDot OSLDs were repeatedly irradiated and bleached to create accumulated dose history. Each group’s repeated irradiation remained constant at either 50, 100, 200, or 500 cGy. Before both irradiation and bleaching the OSLDs were read out, giving the dose reading and ensuring that ample bleaching had occurred, respectively. New and used OSLDs were compared in several clinical situations to verify accuracy. One final test involved correcting the readout dose based on the loss of sensitivity seen in the accumulated dose data. Results: In the first 40 Gy of accumulated dose the sensitivity can be broken into two regions: a region of sensitivity change and a region of no sensitivity change. From 0 cGy to an average of 1080 cGy the sensitivity does not change. After 1080 cGy the sensitivity begins to decrease linearly with an average slope of 0.00456 cGy lost per cGy accumulated after the cutoff point. The slope and cutoff point were used to correct readings in the final test, reducing the error from 6.8% to 3.9%. Conclusion: In the region of no sensitivity change OSLDs can be reused without concern to the validity of their result. Readings must be corrected if OSLDs are to be used in the region of sensitivity change, above 1080 cGy. After 40 Gy OSLDs must be retired because the sensitivity change reverses, making linear correction no longer feasible.

60 APPLIED LIFE SCIENCES↗

Detection and Correction of Step Discontinuities in Kepler Flux Time Series

PDC 8.0 includes an implementation of a new algorithm to detect and correct step discontinuities appearing in roughly one of every 20 stellar light curves during a given quarter. The majority of such discontinuities are believed to result from high-energy particles (either cosmic or solar in origin) striking the photometer and causing permanent local changes (typically -0.5%) in quantum efficiency, though a partial exponential recovery is often observed [1]. Since these features, dubbed sudden pixel sensitivity dropouts (SPSDs), are uncorrelated across targets they cannot be properly accounted for by the current detrending algorithm. PDC detrending is based on the assumption that features in flux time series are due either to intrinsic stellar phenomena or to systematic errors and that systematics will exhibit measurable correlations across targets. SPSD events violate these assumptions and their successful removal not only rectifies the flux values of affected targets, but demonstrably improves the overall performance of PDC detrending [1].

Kolodziejczak, J. J.↗

Molecular radiotherapy: The NUKFIT software for calculating the time-integrated activity coefficient

Purpose: Calculation of the time-integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time-integrated activity coefficient and its standard error.Methods: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user-friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time-integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of <1%. The differences for the time-integrated activity coefficients were also <1% (standard error between 0.4% and 3%). In general, the application of the software is user-friendly and the results are mathematically correct and reproducible. An application of NUKFIT is presented for three different clinical examples.Conclusions: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Properties of the new $ \mathcal{N} $ = 1 AdS 4 vacuum of maximal supergravity

The recent comprehensive numerical study of critical points of the scalar potential of four-dimensional N = 8, SO(8) gauged supergravity using Machine Learning software in [1] has led to a discovery of a new N = 1 vacuum with a triality-invariant SO(3) symmetry. Guided by the numerical data for that point, we obtain a consistent SO(3) × Z 2 -invariant truncation of the N = 8 theory to an N = 1 supergravity with three chiral multiplets. Critical points of the truncated scalar potential include both the N = 1 point as well as two new non-supersymmetric and perturbatively unstable points not found by previous searches. Studying the structure of the submanifold of SO(3) × Z 2 -invariant supergravity scalars, we find that it has a simple interpretation as a submanifold of the 14-dimensional Z $3\atop{2}$ -invariant scalar manifold (SU(1, 1)/U(1)) 7 , for which we find a rather remarkable superpotential whose structure matches the single bit error correcting (7, 4) Hamming code. This 14-dimensional scalar manifold contains approximately one quarter of the known critical points. We also show that there exists a smooth supersymmetric domain wall which interpolates between the new N = 1 AdS4 solution and the maximally supersymmetric AdS4 vacuum. Using holography, this result indicates the existence of an N = 1 RG flow from the ABJM SCFT to a new strongly interacting conformal fixed point in the IR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗