Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Soft X‐ray Ptychographic Imaging and Morphological Quantification of Calcium Silicate Hydrates (C–S–H)

Morphological details of calcium silicate hydrate (C–S–H) stemming from the hydration process of Portland cement ( PC ) phases are crucial for understanding the PC ‐based systems but are still only partially known. Here we introduce the first soft X‐ray ptychographic imaging of tricalcium silicate (C 3 S) hydration products. The results are compared using both scanning transmission X‐ray and electron transmission microscopy data. The evidence shows that ptychography is a powerful method to visualize the details of outer and inner product C–S–H of fully hydrated C 3 S, which have fibrillar and an interglobular structure with average void sizes of 20 nm, respectively. The high‐resolution ptychrography image enables us to perform morphological quantification of C–S–H, and, for the first time, to possibly distinguish the contributions of inner and outer product C–S–H to the small angle scattering of cement paste. The results indicate that the outer product C–S–H is mainly responsible for the q −3 regime, whereas the inner product C–S–H transitions to a q −2 regime. Various hypotheses are discussed to explain these regimes.

Bae, Sungchul↗

A critical review of 25 years of glomalin research: a better mechanical understanding and robust quantification techniques are required

Arbuscular mycorrhizal fungi (AMF) are important contributors to both plant and soil health. Twenty-five years ago, researchers discovered ‘glomalin’, a soil component potentially produced by AMF, which was unconventionally extracted from soil and bound by a monoclonal antibody raised against Rhizophagus irregularis spores. ‘Glomalin’ can resist boiling, strong acids and bases, and protease treatment. Researchers proposed that ‘glomalin’ is a 60 kDa heat shock protein produced by AMF, while others suggested that it is a mixture of soil organic materials that are not unique to AMF. Despite disagreements on the nature of ‘glomalin’, it has been consistently associated with a long list of plant and soil health benefits, including soil aggregation, soil carbon storage and enhancing growth under abiotic stress. The benefits attributed to ‘glomalin’ have caused much excitement in the plant and soil health community; however, the mechanism(s) for these benefits have yet to be established. This review provides insights into the current understanding of the identity of ‘glomalin’, ‘glomalin’ quantification, and the associated benefits of ‘glomalin’. We invite the community to think more critically about how glomalin-associated benefits are generated. We suggest a series of experiments to test hypotheses regarding the nature of ‘glomalin’ and associated health benefits.

59 BASIC BIOLOGICAL SCIENCES↗

Theoretical analysis on the measurement errors of local 2D DIC: Part I temporal and spatial uncertainty quantification of displacement measurements

This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.

2D-DIC↗

Process Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed

A study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Here, three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.

30 DIRECT ENERGY CONVERSION↗

Verification, Validation, and Uncertainty Quantification in Thermal Hydraulics, Freeman Scholar Lecture (2019)

Engineering problems are generally solved by analytical models or computer codes. These models, in addition to conservation equations, also include many empirical relationships and approximate numerical methods. Each of these components contributes to the uncertainty in the prediction. A systematic approach to judge the applicability of the code to the intended application is needed. It starts from verification of implementation of formulation in the code, identification of important phenomena, finding relevant tests with quantified uncertainty for these phenomena, and validation of the code by comparing predictions with the relevant test data. The relevant tests must address phenomena as expected in the intended application. In case of small size or limited condition tests, the scaling analyses are needed to assess the relevancy of the tests. Finally, a statement of uncertainty in the prediction is needed. Systematic approaches are described to aggregate uncertainties from different components of the code for intended application. Here, verification, validation, and uncertainty quantifications (VVUQs) are briefly described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Quantification for Dissimilar Material Joints Under Corrosion Environment

Abstract Self-Piercing Riveting (SPR) is one of the most commonly used methods for joining dissimilar materials in the automotive industry. These joints are popular due to their adaptability, high performance and short cycle time. However, since these joints involve two dissimilar materials, they are susceptible to galvanic corrosion in the presence of an electrolyte which is driven by the difference in the equilibrium potential of the metals. This can affect the safety and resilience of these joints. In this paper, we focus on galvanic corrosion in Al-Fe SPR joints. A Machine learning (ML) based surrogate model, which is based off of FE simulations, for statistical corrosion analysis is developed. This model enables the resilience and reliability analysis of SPR joints under corrosion environment. In this study, first a physics-based finite element (FE) corrosion model has been developed to simulate the galvanic corrosion between a Fe cathode and an Al anode of a SPR joint. This model takes into account the effect of the crystal microstructure of the Al anode and the precipitation of the corrosion product. Several geometric and environmental factors including crevice gap, roughness of anode, conductivity, pH and the temperature of the electrolyte that effect corrosion are investigated. A thorough Uncertainty Quantification (UQ) analysis is conducted for the overall corrosion behavior of the Fe-Al SPR joints using a novelistic Probabilistic Confidence-Based Adaptive Sampling (PCAS) technique. PCAS is used to train the surrogate model by identifying the critical sampling points and thus reducing the overall computational costs. It is found that the electrolyte temperature has the largest effects on the material loss and needs to be managed closely for better corrosion control. By understanding the corrosion performance and resultant uncertainty impact on SPR joints, the reliability and resilience of these joints can be improved.

36 MATERIALS SCIENCE↗

Uncertainty Quantification Techniques for Population Density Estimates Derived from Sparse Open Source Data

The Population Density Tables (PDT) project at the Oak Ridge National Laboratory (www.ornl.gov) is developing population density estimates for specific human activities under normal patterns of life based largely on information available in open source. Currently, activity based density estimates are based on simple summary data statistics such as range and mean. Researchers are interested in improving activity estimation and uncertainty quantification by adopting a Bayesian framework that considers both data and sociocultural knowledge. Under a Bayesian approach knowledge about population density may be encoded through the process of expert elicitation. Due to the scale of the PDT effort which considers over 250 countries, spans 40 human activity categories, and includes numerous contributors, an elicitation tool is required that can be operationalized within an enterprise data collection and reporting system. Such a method would ideally require that the contributor have minimal statistical knowledge, require minimal input by a statistician or facilitator, consider human difficulties in expressing qualitative knowledge in a quantitative setting, and provide methods by which the contributor can appraise whether their understanding and associated uncertainty was well captured. This paper introduces an algorithm that transforms answers to simple, non-statistical questions into a bivariate Gaussian distribution as the prior for the Beta distribution. Based on geometric properties of the Beta distribution parameter feasibility space and the bivariate Gaussian distribution, an automated method for encoding is developed that responds to these challenging enterprise requirements. Though created within the context of population density, this approach may be applicable to a wide array of problem domains requiring informative priors for the Beta distribution.

Bayesian↗

Localization and Quantification of Trace-gas Fugitive Emissions Using a Portable Optical Spectrometer

We present a portable optical spectrometer for fugitive emissions monitoring of methane (CH4). The sensor operation is based on tunable diode laser absorption spectroscopy (TDLAS), using a 5 cm open path design, and targets the 2ν3 R(4) CH4 transition at 6057.1 cm-1 (1651 nm) to avoid cross-talk with common interfering atmospheric constituents. Sensitivity analysis indicates a normalized precision of 2.0 ppmv∙Hz-1/2, corresponding to a noise-equivalent absorption (NEA) of 4.4×10-6 Hz-1/2 and minimum detectible absorption (MDA) coefficient of αmin = 8.8×10-7 cm-1∙Hz-1/2. Our TDLAS sensor is deployed at the Methane Emissions Technology Evaluation Center (METEC) at Colorado State University (CSU) for initial demonstration of single-sensor based source localization and quantification of CH4 fugitive emissions. The TDLAS sensor is concurrently deployed with a customized chemi-resistive metal-oxide (MOX) sensor for accuracy benchmarking, demonstrating good visual correlation of the concentration time-series. Initial angle-of-arrival (AOA) results will be shown, and development towards source magnitude estimation will be described.

03 NATURAL GAS↗

Uncertainty quantification of fireball features extracted from nuclear test films using computer vision

Films from the US’s historic nuclear testing era comprise the only extensive collection of imagery depicting high-yield detonations. These films offer unique insights into the characteristics of flows occurring on scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models used to describe nuclear detonations. In recent work, we implemented modern computer vision and machine learning techniques to extract features of the fireball following nuclear detonation. With a training dataset of fireball films, we fine-tuned a You Only Look Once 11 (YOLO11) model to detect and track the fireball. Applied to a video, the outer bounding box produced in each frame by YOLO11 is used as an input prompt to Meta’s Segment Anything Model 2 (SAM2), which is shown to accurately predict the boundary of the fireball over time with high resolution. These state-of-the-art computer vision foundation models exhibit impressive visual accuracy in their results but lack an output of values that robustly quantify uncertainty in scientific applications. In this paper, we develop procedures for uncertainty quantification of extracted fireball features. We outline the application of a parallel attention mechanism to calculate uncertainty ranges that complement and better pose model validation data. This higher quality fireball validation data may serve to improve prognostic models describing nuclear detonations in support of nuclear forensic and emergency response activities.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

Interactive image quantification tools in nuclear material forensics

Morphological and microstructural features visible in microscopy images of nuclear materials can give information about the processing history of a nuclear material. Extraction of these attributes currently requires a subject matter expert in both microscopy and nuclear material production processes, and is a time consuming, and at least partially manual task, often involving multiple software applications. One of the primary goals of computer vision is to find ways to extract and encode domain knowledge associated with imagery so that parts of this process can be automated. In this paper we describe a user-in-the-loop approach to the problem which attempts to both improve the efficiency of domain experts during image quantification as well as capture their domain knowledge over time. This is accomplished through a sophisticated user-monitoring system that accumulates user-computer interactions as users exploit their imagery. We provide a detailed discussion of the interactive feature extraction and segmentation tools we have developed and describe our initial results in exploiting the recorded user-computer interactions to improve user productivity over time.

36 MATERIALS SCIENCE↗

Quantification of arterial plaque and lumen density with MDCT

Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-{mu}{sup *}d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c{sup *}exp(-a{sup *}d{sup b}) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density {rho} (g/cm{sup 3}). This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of abdominal fat quantification on CT imaging through use of standardized anatomic space: A novel approach

Purpose: The quantification of body fat plays an important role in the study of numerous diseases. It is common current practice to use the fat area at a single abdominal computed tomography (CT) slice as a marker of the body fat content in studying various disease processes. This paper sets out to answer three questions related to this issue which have not been addressed in the literature. At what single anatomic slice location do the areas of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) estimated from the slice correlate maximally with the corresponding fat volume measures? How does one ensure that the slices used for correlation calculation from different subjects are at the same anatomic location? Are there combinations of multiple slices (not necessarily contiguous) whose area sum correlates better with volume than does single slice area with volume? Methods: The authors propose a novel strategy for mapping slice locations to a standardized anatomic space so that same anatomic slice locations are identified in different subjects. The authors then study the volume-to-area correlations and determine where they become maximal. To address the third issue, the authors carry out similar correlation studies by utilizing two and three slices for calculating area sum. Results: Based on 50 abdominal CT data sets, the proposed mapping achieves significantly improved consistency of anatomic localization compared to current practice. Maximum correlations are achieved at different anatomic locations for SAT and VAT which are both different from the L4-L5 junction commonly utilized currently for single slice area estimation as a marker. Conclusions: The maximum area-to-volume correlation achieved is quite high, suggesting that it may be reasonable to estimate body fat by measuring the area of fat from a single anatomic slice at the site of maximum correlation and use this as a marker. The site of maximum correlation is not at L4-L5 as commonly assumed, but is more superiorly located at T12-L1 for SAT and at L3-L4 for VAT. Furthermore, the optimal anatomic locations for SAT and VAT estimation are not the same, contrary to common assumption. The proposed standardized space mapping achieves high consistency of anatomic localization by accurately managing nonlinearities in the relationships among landmarks. Multiple slices achieve greater improvement in correlation for VAT than for SAT. The optimal locations in the case of multiple slices are not contiguous.

60 APPLIED LIFE SCIENCES↗

SU-E-J-86: Lobar Lung Function Quantification by PET Galligas and CT Ventilation Imaging in Lung Cancer Patients

Purpose: The purpose of this study was to quantify the lobar lung function using the novel PET Galligas ([68Ga]-carbon nanoparticle) ventilation imaging and the investigational CT ventilation imaging in lung cancer patients pre-treatment. Methods: We present results on our first three lung cancer patients (2 male, mean age 78 years) as part of an ongoing ethics approved study. For each patient a PET Galligas ventilation (PET-V) image and a pair of breath hold CT images (end-exhale and end-inhale tidal volumes) were acquired using a Siemens Biograph PET CT. CT-ventilation (CT-V) images were created from the pair of CT images using deformable image registration (DIR) algorithms and the Hounsfield Unit (HU) ventilation metric. A comparison of ventilation quantification from each modality was done on the lobar level and the voxel level. A Bland-Altman plot was used to assess the difference in mean percentage contribution of each lobe to the total lung function between the two modalities. For each patient, a voxel-wise Spearmans correlation was calculated for the whole lungs between the two modalities. Results: The Bland-Altman plot demonstrated strong agreement between PET-V and CT-V for assessment of lobar function (r=0.99, p<0.001; range mean difference: −5.5 to 3.0). The correlation between PET-V and CT-V at the voxel level was moderate(r=0.60, p<0.001). Conclusion: This preliminary study on the three patients data sets demonstrated strong agreement between PET and CT ventilation imaging for the assessment of pre-treatment lung function at the lobar level. Agreement was only moderate at the level of voxel correlations. These results indicate that CT ventilation imaging has potential for assessing pre-treatment lobar lung function in lung cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-J-155: Utilizing Varian TrueBeam Developer Mode for the Quantification of Mechanical Limits and the Simulation of 4D Respiratory Motion

Purpose: Use Varian TrueBeam Developer mode to quantify the mechanical limits of the couch and to simulate 4D respiratory motion. Methods: An in-house MATLAB based GUI was created to make the BEAM XML files. The couch was moved in a triangular wave in the S/I direction with varying amplitudes (1mm, 5mm, 10mm, and 50mm) and periods (3s, 6s, and 9s). The periods were determined by specifying the speed. The theoretical positions were compared to the values recorded by the machine at 50 Hz. HD videos were taken for certain tests as external validation. 4D Respiratory motion was simulated by an A/P MV beam being delivered while the couch moved in an elliptical manner. The ellipse had a major axis of 2 cm (S/I) and a minor axis of 1 cm (A/P). Results: The path planned by the TrueBeam deviated from the theoretical triangular form as the speed increased. Deviations were noticed starting at a speed of 3.33 cm/s (50mm amplitude, 6s period). The greatest deviation occurred in the 50mm- 3s sequence with a correlation value of −0.13 and a 27% time increase; the plan essentially became out of phase. Excluding these two, the plans had correlation values of 0.99. The elliptical sequence effectively simulated a respiratory pattern with a period of 6s. The period could be controlled by changing the speeds or the dose rate. Conclusion: The work first shows the quantification of the mechanical limits of the couch and the speeds at which the proposed plans begin to deviate. These limits must be kept in mind when programming other couch sequences. The methodology can be used to quantify the limits of other axes. Furthermore, the work shows the possibility of creating 4D respiratory simulations without using specialized phantoms or motion-platforms. This can be further developed to program patient-specific breathing patterns.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-G-18C-07: Improving T2 Determination and Quantification of Lipid Methylene Protons in Proton Magnetic Resonance Spectroscopy at 3 T

Purpose: To improve proton magnetic resonance spectroscopy (MRS) transverse relaxation (T{sub 2}) determination and quantification of lipid methylene chain (1.3 ppm) protons by rewinding their J-coupling evolution. Methods: MRS experiments were performed on four lipid phantoms, namely, almond, corn, sunflower and oleic acid, using a 3 T Philips MRI scanner with a transmit/receive birdcage head coil. Two PRESS (Point RESolved Spectroscopy) pulse sequences were used. The first PRESS sequence employed standard bandwidth (BW) (∼550 Hz) RF (radiofrequency) refocussing pulses, while the second used refocussing pulses of narrow BW (∼50 Hz) designed to rewind J-coupling evolution of the methylene protons in the voxel of interest. Signal was acquired with each sequence from a 5×5×5 mm{sup 3} voxel, with a repetition time (TR) of 3000 ms, and with echo times (TE) of 100 to 200 ms in steps of 20 ms. 2048 sample points were measured with a 2000 Hz sampling bandwidth. Additionally, 30 mm outer volume suppression slabs were used to suppress signal outside the voxel of interest. The frequency of the RF pulses was set to that of the methylene resonance. Methylene peak areas were calculated and fitted in MATLAB to a monexponentially decaying function of the form M{sub 0}exp(-TE/T{sub 2}), where M{sub 0} is the extrapolated area when TE = 0 ms and yields a measure of concentration. Results: The determined values of M{sub 0} and T{sub 2} increased for all fatty acids when using the PRESS sequence with narrow BW refocussing pulses. M{sub 0} and T{sub 2} values increased by an average amount (over all the phantoms) of 31% and 14%, respectively. Conclusion: This investigation has demonstrated that J-coupling interactions of lipid methylene protons causes non-negligible signal losses which, if not accounted for, Result in underestimations of their levels and T{sub 2} values when performing MRS measurements. Funded by the Natural Sciences and Engineering Research Council of Canada and the Canadian Breast Cancer Foundation - Prairies.NWT.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-10: Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation

Purpose: Recent advances in medical imaging technologies provide opportunities to quantify the tumor phenotype throughout the course of treatment non-invasively. The emerging field of Radiomics addresses this by converting medical images into minable data by applying a large number of quantitative imaging algorithms. Accurate tumor segmentation is one of the main challenges of Radiomics. It has been shown that semiautomatic segmentation approaches efficiently reduce inter-observer variability as compared to the time consuming manual delineations. In this study, a semiautomatic volumetric segmentation algorithm, implemented in the free and publicly available 3D-Slicer platform, was investigated in terms of its robustness for Radiomics features quantification. Methods: Fifty-six 3D-Radiomics features, quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the computed tomography images of twenty lung cancer patients. These Radiomics features were derived from the 3D-tumor volumes defined by three independent observers twice using 3D-Slicer, and compared to manual slice-by-slice delineations of five independent physicians in terms of intra-class correlation coefficient (ICC) and feature range. Results: Radiomics features extracted from 3D-Slicer segmentations had significantly higher reproducibility (ICC= 0.85 0.15, p=0.0009) compared to the features extracted from the manual segmentations (ICC= 0.77 0.17). Furthermore, the features extracted from 3D-Slicer based segmentations, spread over significantly smaller range across observers as compared to those of the manual delineations (p= 3.819e-07). Moreover, the features derived from 3D-Slicer segmentations overlapped in range with those of the manual delineations, as the lower(higher) limit(s) being significantly higher(lower) for the 3D-Slicer features (p= 0.007, p= 5.863e-06). Conclusion: 3D-Slicer based semiautomatic segmentation significantly improves the robustness of radiomics features and thus could serve as a potential alternative to the time consuming manual segmentation process. So 3D-Slicer can have a large application in Radiomics, and be employed for high-throughput data mining research of medical imaging in clinical oncology.

60 APPLIED LIFE SCIENCES↗

PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of {sup 90}Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2 ± 14.7)%]. Conclusions: Qualitative and quantitative{sup 90}Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with {sup 90}Y-microspheres and allows dose estimation.

60 APPLIED LIFE SCIENCES↗

A multifractal approach to space-filling recovery for PET quantification

Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.

60 APPLIED LIFE SCIENCES↗