Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A continuous fluorescence assay for simple quantification of bile salt hydrolase activity in the gut microbiome

The microbiota of the mammalian gut plays a dynamic role in controlling host physiology. The effect of gut microbiota activity on host health is particularly evident in the case of bile homeostasis. Bile is produced by the host and is modified by the gut microbiota, which impacts the net hydrophobicity of the total bile acid pool, and also modulates host signaling pathways. A key mechanism by which the microbiota modify bile is through de-conjugation of bile salts through bile salt hydrolase (BSH) enzymatic activity, which is postulated to be a prerequisite for all further microbial metabolism. BSH activity in the gut is largely considered to be beneficial, and genes encoding BSHs are found in the genomes of many taxa found in over-the-counter probiotics. Despite the therapeutic relevance of this enzyme, there is no reliable and simple assay for continuous monitoring of BSH activity, and there are no non-destructive means of characterizing its activity in whole cell or microbial community samples. Herein, we describe a continuous fluorescence assay that can be used for characterization of BSH activity with purified protein, cell lysates, whole cells, and in human gut microbiome samples. The method is a “turn-on” reporter strategy, which employs synthetic substrates that yield a fluorescent product upon BSH-dependent turnover. This assay is used to show the first in vivo characterization of BSH activity. Furthermore, we demonstrate the first example of continuous, non-destructive quantification of BSH activity in human gut microbiome samples.

59 BASIC BIOLOGICAL SCIENCES↗

The need for uncertainty quantification in machine-assisted medical decision making

We present that medicine, even from the earliest days of artificial intelligence (AI) research, has been one of the most inspiring and promising domains for the application of AI-based approaches. Equally, it has been one of the more challenging areas to see an effective adoption. There are many reasons for this, primarily the reluctance to delegate decision making to machine intelligence in cases where patient safety is at stake. To address some of these challenges, medical AI, especially in its modern data-rich deep learning guise, needs to develop a principled and formal uncertainty quantification (UQ) discipline, just as we have seen in fields such as nuclear stockpile stewardship and risk management. The data-rich world of AI-based learning and the frequent absence of a well-understood underlying theory poses its own unique challenges to straightforward adoption of UQ. These challenges, while not trivial, also present significant new research opportunities for the development of new theoretical approaches, and for the practical applications of UQ in the area of machine-assisted medical decision making. Finally, understanding prediction system structure and defensibly quantifying uncertainty is possible, and, if done, can significantly benefit both research and practical applications of AI in this critical domain.

97 MATHEMATICS AND COMPUTING↗

Quantification of acidic compounds in complex biomass-derived streams

Biomass-derived streams that contain acidic compounds from the degradation of lignin and polysaccharides (e.g. black liquor, pyrolysis oil, pyrolytic lignin, etc.) are chemically complex solutions prone to instability and degradation during analysis, making quantification of compounds within them challenging. Here we present a robust analytical method to quantify acidic compounds in complex biomass-derived mixtures using ion exchange, sample reconstitution in pyridine and derivatization with BSTFA. The procedure is based on an earlier method originally reported for kraft black liquors and, in this work, is applied to identify and quantify a large slate of acidic compounds in corn stover derived alkaline pretreatment liquor (APL) as a function of pretreatment severity. Analysis of the samples is conducted with GCxGC-TOFMS to achieve good resolution of the components within the complex mixture. The results reveal the dominant low molecular weight components and their concentrations as a function of pretreatment severity. Application of this method is also demonstrated in the context of lignin conversion technologies by applying it to track the microbial conversion of an APL substrate. Here as well excellent results are achieved, and the appearance and disappearance of compounds is observed in agreement with the known metabolic pathways of two bacteria, indicating the sample integrity was maintained throughout analysis. Finally, it is shown that this method applies more generally to lignin-rich materials by demonstrating its usefulness in analysis of pyrolysis oil and pyrolytic lignin.

09 BIOMASS FUELS↗

Quantification of the loss mechanisms in emerging water splitting photoanodes through empirical extraction of the spatial charge collection efficiency

We present that the operando quantification of surface and bulk losses is key to developing strategies for optimizing photoelectrodes and realizing high efficiency photoelectrochemical solar energy conversion systems. This is particularly true for emerging thin film semiconductors, in which photocarrier diffusion lengths, surface and bulk recombination processes, and charge separation and extraction limitations are poorly understood. Insights into mechanisms of efficiency loss can guide strategies for nanostructuring photoelectrodes, engineering interfaces, and incorporating catalysts. However, few experimental methods are available for direct characterization of dominant loss processes under photoelectrochemical operating conditions. In this work, we provide insight into the function and limitations of an emerging semiconductor photoanode, γ-Cu 3 V 2 O 8 , by quantifying the spatial collection efficiency (SCE), which is defined as the fraction of photogenerated charge carriers at each point below the surface that contributes to the measured current. Analyzing SCE profiles at different operating potentials shows that increasing the applied potential primarily acts to reduce surface recombination rather than to increase the thickness of the space charge region under the semiconductor/electrolyte interface. Comparing SCE profiles obtained with and without a sacrificial reagent allows surface losses from electronically active defect states to be distinguished from performance bottlenecks arising from slow reaction kinetics. Combining these insights promotes a complete understanding of the photoanode performance and its potential as a water splitting photoanode. More generally, application of the SCE extraction method can aid in the discovery and evaluation of new materials for solar water splitting devices by providing mechanistic details underlying photocurrent generation and loss.

14 SOLAR ENERGY↗

Emerging investigator series: quantification of multiwall carbon nanotubes in plant tissues with spectroscopic analysis

If agricultural plants are exposed to carbon nanotubes (CNTs), they can potentially take up the CNTs from growth media and translocate them to their different tissues. In addition, agricultural application of CNTs recently attracted increasing attention, as they could promote germination, enhance crop yield, and exhibit other benefits. For evaluating the environmental effects of CNTs and optimizing their agricultural application, it is essential to quantify CNTs in plant tissues. In this study, pristine (p-) and carboxyl-functionalized (c-) multiwall CNTs (MWCNTs) were extracted from plant tissues by a sequential digestion with nitric acid (HNO 3 ) and sulfuric acid (H 2 SO 4 ). The extracted MWCNTs were stabilized with nonionic surfactant Triton X-100 and analyzed with ultraviolet-visible (UV-vis) spectroscopic analysis to measure the concentration of the MWCNTs in plant (lettuce) tissues. The MWCNT concentration was linearly correlated with the absorbance at 800 nm. The detection limit for p- and c-MWCNTs was achieved at 0.10–0.12, 0.070–0.081, 0.019–0.18 μg mg -1 for leaf, stem, and root tissues, respectively. The developed method was applied for lettuce (Lactuca sativa, cv. black seeded Simpson) hydroponically grown with 5, 10, 20 mg L -1 of p-MWCNTs and c-MWCNTs in the culture solution. We detected 0.21 ± 0.05–4.57 ± 0.39 μg mg -1 p-MWCNTs and 0.20 ± 0.17–0.75 ± 0.25 μg mg -1 c-MWCNTs in the lettuce roots, positively correlated with the dose of CNTs in solution. We have come up with a method for rapid quantification of CNTs in plant tissues using a widely-accessible technique, which can enable reliable analysis of CNTs in plant tissues and provide critical information for evaluating the environmental implications and managing agricultural application of CNTs.

54 ENVIRONMENTAL SCIENCES↗

Direct time-resolved detection and quantification of key reactive intermediates in diethyl ether oxidation at T = 450–600 K

High-pressure multiplexed photoionization mass spectrometry (MPIMS) with tunable vacuum ultraviolet (VUV) ionization radiation from the Lawrence Berkeley Labs Advanced Light Source is used to investigate the oxidation of diethyl ether (DEE). Kinetics and photoionization (PI) spectra are simultaneously measured for the species formed. Several stable products from DEE oxidation are identified and quantified using reference PI cross-sections. In addition, we directly detect and quantify three key chemical intermediates: peroxy (ROO˙), hydroperoxyalkyl peroxy (˙OOQOOH), and ketohydroperoxide (HOOP[double bond, length as m-dash]O, KHP). These intermediates undergo dissociative ionization (DI) into smaller fragments, making their identification by mass spectrometry challenging. Furthermore, with the aid of quantum chemical calculations, we identify the DI channels of these key chemical species and quantify their time-resolved concentrations from the overall carbon atom balance at T = 450 K and P = 7500 torr. This allows the determination of the absolute PI cross-sections of ROO˙, ˙OOQOOH, and KHP into each DI channel directly from experiment. The PI cross-sections in turn enable the quantification of ROO˙, ˙OOQOOH, and KHP from DEE oxidation over a range of experimental conditions that reveal the effects of pressure, O 2 concentration, and temperature on the competition among radical decomposition and second O 2 addition pathways.

42 ENGINEERING↗

Quantification of defects engineered in single layer MoS 2

Atomic defects are controllably introduced in suspended single layer molybdenum disulfide (1L MoS 2 ) using helium ion beam. Vacancies exhibit one missing atom of molybdenum and a few atoms of sulfur. Quantification was done using a Scanning Transmission Electron Microscope (STEM) with an annular detector. Experimentally accessible inter-defect distance was employed to measure the degree of crystallinity in 1L MoS 2 . A correlation between the appearance of an acoustic phonon mode in the Raman spectra and the inter-defect distance was established, which introduces a new methodology for quantifying defects in two-dimensional materials such as MoS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous quantification of uranium( VI ), samarium, nitric acid, and temperature with combined ensemble learning, laser fluorescence, and Raman scattering for real-time monitoring

In this work, laser-induced fluorescence spectroscopy (LIFS), Raman spectroscopy, and a stacked regression ensemble was developed for near real-time quantification of uranium(VI) (1–100 μg mL –1 ), samarium (0–200 μg mL –1 ) and nitric acid (0.1–4 M) with varying temperature (20 °C–45 °C). LIFS applications range from fundamental lab-scale studies to real-time process monitoring at industrial levels, such as nuclear reprocessing applications, provided the phenomena affecting the fluorescence spectrum are accounted for (e.g., absorption, quenching, complexation). Multiple chemometric models were examined and compared to a more traditional multivariate regression approach called partial least squares (PLS). Results obtained on synthetic samples selected using D-optimal experimental design indicated that a stacked regression method, which included ridge regression, random forest, PLS, and an eXtreme gradient boost algorithm, successfully measured uranium(VI) concentrations directly in nitric acid without measuring luminescence lifetimes or standard addition. The top model resulted in percent root-mean-square error of prediction values of 5.2, 1.9, 3.0, and 2.3% for U(VI), Sm 3+ , HNO 3 , and temperature, respectively. The approach may be useful for quantifying fluorescent fission products (e.g., Sm 3+ ) to provide information on burnup of irradiated nuclear fuel. This novel framework reinforces the applicability of LIFS for real-time applications in nuclear fuel cycle applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimization and quantification of silver( II ) for mediated electrochemical oxidation applications

Mediated electrochemical oxidation (MEO) is a low-temperature, low-pressure, aqueous mineralization process used to treat organic waste. A powerful metal oxidant is used as a mediator in an acidic solution. Although Ce and Co are thoroughly studied mediators, Ag is a preferred choice because of the higher efficiency rates of mineralization observed with this system. Importantly, the quantification methodology and spectroscopic characteristics of the Ag(II) ion must be obtained. In this study, we determined molar extinction coefficients of the primary absorption band associated with the Ag(II) ion in 2–9 M HNO 3 solution. The optimization of Ag(II) electrooxidation was also determined by altering parameters such as HNO 3 concentration, mediator concentration, and temperature. The optimization studies and extinction coefficient data provide parameters for implementation of Ag as a suitable mediator for MEO processing of organic waste.

Schrage, Briana R. [Oak Ridge National Laboratory ↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Experimental uncertainty quantification using templates of expected measurement uncertainties for fast neutron-induced total, capture, and scattering cross sections

Careful experimental uncertainty quantification (UQ) is key for developing trustworthy evaluated nuclear data. Templates to account for missing or under-reported experimental uncertainties were recently developed by the covariance committee of Cross Section Evaluation Working Group (CSEWG). In this work, we illustrate the practical application and limitations of these templates for selected neutron-induced reactions, including (n, tot), (n, γ), and (n, xn) in the fast energy range, to illustrate their use in data analyses for nuclear data evaluations. We show that while the templates provide consistent framework, proper implementation still requires detailed knowledge of experimental conditions and careful treatment of nonlinear effects in cross section derivation. Case studies highlight how template-assisted UQ improves consistency with previous evaluations such as ENDF/B and reveals open challenges in propagating uncertainties across different energy regimes. The main contribution of this paper is to connect formal template recommendations with their use in practical evaluation workflows, clarifying both their benefits and current limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification of self-sputtering and implantation during pulsed laser deposition of gold

This work reports on the quantification of self-sputtering and implantation occurring during pulsed laser deposition of Au as a function of the laser fluence used to ablate the gold target. The experimental approach includes, on one hand, in situ electrical (Langmuir) and optical (two-dimensional imaging) probes for determining, respectively, ion and excited neutral kinetic energy distributions. On the other hand, it includes determination of the density of (i) ions reaching a substrate, and (ii) gold atoms deposited on a substrate as well as of a proportion of atoms that are self-sputtered. The experimental results supported by numerical analysis show that self-sputtering and implantation are both dominated by ions having kinetic energies {>=}200 eV. They are a fraction 0.60-0.75 of the species arriving to the substrate for ablation laser fluences 2.7-9.0 J cm{sup -2}. Self-sputtering yields in the range 0.60-0.86 are determined for the same fluence range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of the ion and momentum fluxes toward the substrate during reactive magnetron sputtering

The ion and momentum fluxes toward the growing film during reactive magnetron sputtering of a Ti target in a mixture of Ar and N{sub 2} are determined. For the ion flux and ion energy distribution a retarding field energy analyzer has been employed. The results were confronted with planar and cylindrical probe measurements, two more common used techniques. For the momentum flux, energy resolved mass spectrometry and simulations with the binary collision Monte Carlo code SIMTRA were performed to determine the contribution to this flux by the impact of ions and sputtered and reflected particles. Based on the quantification of both fluxes, it can be concluded that there is a relation between the hardness and elastic modulus of the TiN films and the momentum flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Why do Ladybugs Smell Bad? In-vivo Quantification of Odorous Insect Kairomones with SPME and Multidimensional GC-MS-Olfactometry

Winemakers, small fruit growers, and homeowners are concerned with noxious compounds released by multicolored Asian ladybird beetles (Harmonia axyridis, Coleoptera: Coccinellidae). New method based on headspace solid phase microextraction (HS-SPME) coupled with multidimensional gas chromatography mass spectrometry--olfactometry (MDGC-MS-O) system was developed for extraction, isolation and simultaneous identification of compounds responsible for the characteristic odor of live H. axyridis. Four methoxypyrazines (MPs) were identified in headspace volatiles of live H. axyridis as those responsible for the characteristic odor: 2, 5-dimethy1-3-methoxypyrazine (DMMP), 2-isopropy1-3-methoxypyrazine (IPMP), 2-sec-buty1-3-methoxypyrazine (SBMP), and 2-isobuty1-3-methoxypyrazine (IBMP). To the best of our knowledge this is the first report of H. axyridis releasing DMMP and the first report of this compound being a component of the H. axyridis characteristic odor. Quantification of three MPs (IPMP, SBMP and IBMP) emitted from live H. axyridis were performed using external calibration with HS-SPME and direct injections. A linear relationship (R{sup 2}>0.9958 for all 3 MPs) between MS response and concentration of standard was observed over a concentration range from 0.1 ng L{sup -1} to 0.05 {mu}g L{sup -1} for HS-SPME-GC-MS. The method detection limits (MDL) based on multidimensional GC-MS approach for three MPs were estimated to be between 0.020 ng L{sup -1}. to 0.022 ng L{sup -1}. This methodology is applicable for in vivo determination of odor-causing chemicals associated with emissions of volatiles from insects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recurrence quantification analysis of turbulent fluctuations in the plasma edge of Tokamak Chauffage Alfven Bresilien tokamak

Recurrences are close returns of a given state in a time series, and can be used to identify different dynamical regimes and other related phenomena, being particularly suited for analyzing experimental data. In this work, we use recurrence quantification analysis to investigate dynamical patterns in scalar data series obtained from measurements of floating potential and ion saturation current at the plasma edge of the Tokamak Chauffage Alfven Bresilien [R. M. O. Galvao et al., Plasma Phys. Controlled Fusion 43, 1181 (2001)]. We consider plasma discharges with and without the application of radial electric bias, and also with two different regimes of current ramp. Our results indicate that biasing improves confinement through destroying highly recurrent regions within the plasma column that enhance particle and heat transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a 'one-chip' approach using 'Bio-chips' made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗