Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Performance of Energy Storage with Nuclear and Renewable Power Systems

Nuclear power represents a traditional baseload power component to the grid, while renewables output variable amounts of power at unpredictable times. Nuclear and renewable energy integration (NREI) systems have previously been explored as valuable additions to the existing power grid. Energy storage systems can allow power plants to store energy mechanically using pumped hydro or compressed air, thermally using liquid salt or steam accumulators, or chemically with batteries. The addition of energy storage to NREI systems can allow for the discharge of electricity to adjust to demands placed on the grid. The allocation of energy to adjust to grid demand is explored through a historical 8,760-hour analysis including nuclear, wind, and solar NREI systems with energy storage. The operation of storage systems is compared through simulations of different storage and discharge parameters based off the maximum daily grid demands, and hourly electricity prices. The overall profitability of storage systems is determined by comparing simulation results for the overall net revenue increases exceeding storage efficiency losses. Several NREI systems have increased the value of electricity for both solar PV and wind energy, in combination with nuclear power. Optimization of these systems is developed using MATLAB code and the simulations of the most profitable results are explored.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A nonventing cooling system for space environment extravehicular activity, using radiation and regenerable thermal storage

This paper outlines the selection, design, and testing of a prototype nonventing regenerable astronaut cooling system for extravehicular activity space suit applications, for mission durations of four hours or greater. The selected system consists of the following key elements: a radiator assembly which serves as the exterior shell of the portable life support subsystem backpack; a layer of phase change thermal storage material, n-hexadecane paraffin, which acts as a regenerable thermal capacitor; a thermoelectric heat pump; and an automatic temperature control system. The capability for regeneration of thermal storage capacity with and without the aid of electric power is provided.

Bayes, Stephen A.↗

Energy storage by compressed air

The feasibility of windpower energy storage by compressed air is considered. The system is comprised of a compressor, a motor, and a pump turbine to store air in caverns or aquifiers. It is proposed that storage of several days worth of compressed air up to 650 pounds per square inch can be used to push the aquifier up closer to the container dome and thus initiate piston action by simply compressing air more and more. More energy can be put into it by pressure increase or pushing back the water in the aquifier. This storage system concept has reheat flexibility and lowest cost effectiveness.

Szego, G. C.↗

Novel PCM Integration with Electrical Heat Pump for Demand Response

In this paper, we examine the potential for using phase change material (PCM) as a thermal storage medium for improving the efficiency as well as enabling grid-responsive control of heat pump (HP) systems. Previous research in PCM integration in buildings has primarily been focused on integration with building envelopes. An objective of our research is to design a novel and practical PCM integration with existing HP systems. High-fidelity models for building, HP and PCM are developed to facilitate the model-based predictive control (MPC) design. To optimize the operation of HP and PCM, we introduce an optimization problem considering various constraints for both comfort and hardware constraints. We include experimental results in which a house fleet are optimized to minimize their power consumption or electricity cost. We numerically demonstrate the designs potential for reducing power consumption or electricity cost by 13% or 19%, respectively.

Dong, Jin↗

Greenbuilt Retrofit Test House (Final Report)

The Greenbuilt house is a 1980's era house in the Sacramento area that was a prominent part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration Program. The house underwent an extensive remodel, aimed at improving overall energy efficiency with a goal of reducing the home's energy use by 50%. NREL researchers performed a number of tests on the major systems touched by the retrofit to ensure they were working as planned. Additionally, SMUD rented the house from Greenbuilt Construction for a year to allow NREL to perform a number of tests on the cooling system and the water heating system. The goal of the space conditioning tests was to find the best ways to cut cooling loads and shift the summer peak. The water heating system, comprised of an add-on heat pump water heater and an integrated collector-storage solar water heater, was operated with a number of different draw profiles to see how varying hot water draw volume and schedule affected the performance of the system as a whole. All the experiments were performed with the house empty, with a simulated occupancy schedule running in the house to mimic the load imposed by real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatially Refined Satellite Gravimetry Captures Human Signatures in Global Terrestrial Water Storage Trends

Human activities have directly altered the water cycle through water management, aquifer pumping, agricultural irrigation, and land use change. Although satellite gravimetry has transformed global hydrological research, its coarse resolution limits attribution of freshwater change to human activities at many management-relevant scales. Here we assessed global terrestrial water storage (TWS) trends from April 2002 to November 2025 using “stacked” regression of Level-1B intersatellite ranging data, which leverages temporal information and variability to dramatically improve effective spatial resolution relative to standard approaches. We combined this refined product with rigorous uncertainty analysis, autocorrelation-robust geostatistical methods, and literature assessment to evaluate TWS trend associations with land and water use, climate variability, and glacial mass loss. We identified TWS trend hotspots exhibiting significant spatial associations with anthropogenic 40 drivers, including groundwater and surface-water irrigation, rainfed agriculture, deforestation, and reservoir impoundment. Across these regions, cumulative TWS losses (3,122 Gt) substantially exceeded gains (2,432 Gt). Compared with traditional regression of monthly mascons, our approach yielded regional trend magnitudes that are on average 33% larger, revealing that global freshwater depletion, particularly from groundwater pumping, is considerably more acute than previously estimated. Multivariate regression models show that humans account for a significant share of the spatial variability in TWS trends on every non-polar continent except Australia. We detected localized TWS gains linked to rainfed agriculture, surface water irrigation, and reservoir filling that were unresolved in earlier gravimetric studies. The methodology provides a foundation for future gravity missions to independently track decadal freshwater change with unprecedented spatial fidelity.

groundwater↗

Hot-water aquifer storage: A field test

The basic water injection cycle used in a large-scale field study of heat storage in a confined aquifer near Mobile, Alabama is described. Water was pumped from an upper semi-confined aquifer, passed through a boiler where it was heated to a temperature of about 55 C, and injected into a medium sand confined aquifer. The injection well has a 6-inch (15-cm) partially-penetrating steel screen. The top of the storage formation is about 40 meters below the surface and the formation thickness is about 21 meters. In the first cycle, after a storage period of 51 days, the injection well was pumped until the temperature of the recovered water dropped to 33 c. At that point 55,300 cubic meters of water had been withdrawn and 66 percent of the injected energy had been recovered. The recovery period for the second cycle continued until the water temperature was 27.5 C and 100,100 cubic meters of water was recovered. At the end of the cycle about 90 percent of the energy injected during the cycle had been recovered.

Parr, A. D.↗

A review of energy storage technologies for demand-side management in industrial facilities

Demand-side management (DSM) in industrial facilities provides an opportunity for substantial amounts of energy cost savings, since industrial facilities are the largest energy consuming sectors globally. In this work, energy storage (ES) technologies are critically reviewed and compared with industrial DSM in mind. ES technologies reviewed herein include lithium-ion battery energy storage (BES), sodium-sulfur BES, lead-acid BES, flow BES, supercapacitor ES, superconducting magnetic ES, thermal ES, flywheel ES, pumped hydro ES, and compressed air ES. The fundamentals of these energy storage technologies are reviewed in detail including recent developments, followed by case studies and extensive comparisons. These comparisons include, but are not limited to cost per cycle analyses, levelized cost of energy analyses, and comparisons between performance, transient, and cost characteristics. Here, some key properties analyzed include the rated power, power density, efficiency, lifetime, discharge time, capital costs, and O&M costs.

25 ENERGY STORAGE↗

Design concepts for the ASTROMAG cryogenic system

Described is a proposed cryogenic system used to cool the superconducting magnet for the Space Station based ASTROMAG Particle Astrophysics Facility. This 2-meter diameter superconducting magnet will be cooled using stored helium II. The paper presents a liquid helium storage concept which would permit cryogenic lifetimes of up to 3 years between refills. It is proposed that the superconducting coil be cooled using superfluid helium pumped by the thermomechanical effect. It is also proposed that the storage tank be resupplied with helium in orbit. A method for charging and discharging the magnet with minimum helium loss using split gas-cooled leads is discussed. A proposal to use a Stirling cycle cryocooler to extend the storage life of the cryostat will also be presented.

Green, M. A.↗

Design concepts for the ASTROMAG cryogenic system

Described is a proposed cryogenic system used to cool the superconducting magnet for the Space Station based ASTROMAG Particle Astrophysics Facility. This 2-meter diameter superconducting magnet will be cooled using stored helium II. The paper presents a liquid helium storage concept which would permit cryogenic lifetimes of up to 3 years between refills. It is proposed that the superconducting coil be cooled using superfluid helium pumped by the thermomechanical effect. It is also proposed that the storage tank be resupplied with helium in orbit. A method for charging and discharging the magnet with minimum helium loss using split gas-cooled leads is discussed. A proposal to use a Stirling cycle cryocooler to extend the storage life of the cryostat will also be presented.

Green, M. A.↗

Effect of Emergency Argon on FCF Operational Incidents

The following report presents analyses of operational incidents which are considered in the safety analysis of the FCF argon cell and the effect that the operability of the emergency argon system has on the course of these incidents. The purpose of this study is to determine if the emergency argon system makes a significant difference in ameliorating the course of these incidents. Six incidents were considered. The following three incidents were analyzed. These are: 1. Cooling failing on 2. Vacuum Pump Failing on 3. Argon Supplies Failing on. In the remaining three incidents, the emergency argon supply would have no effect on the course of these transients since it would not come on during these incidents. The transients are 1. Loss of Cooling 2. Loss of power (Differs from above by startup delay till the Diesel Generators come on.) 3. Cell rupture due to an earthquake or other cause. The analyses of the first three incidents are reported on in the next three sections. This report is issued realizing the control parameters used may not be optimum, and additional modeling must be done to model the inertia of refrigeration system, but the major conclusion concerning the need for the emergency argon system is still valid. The timing of some events may change with a more accurate model but the differences between the transients with and without emergency argon will remain the same. Some of the parameters assumed in the analyses are Makeup argon supply, 18 cfm, initiates when pressure is = -6 iwg., shuts off when pressure is = -3.1 iwg. 170,000 ft3 supply. Min 1/7th always available, can be cross connected to HFEF argon supply dewar. Emergency argon supply, 900 cfm, initiates when pressure is = -8 iwg. shuts off when pressure is =-4 iwg. reservoir 220 ft3, refilled when tank farm pressure reduces to 1050 psi which is about 110 ft3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel-Cell Power Systems Incorporating Mg-Based H2 Generators

Two hydrogen generators based on reactions involving magnesium and steam have been proposed as means for generating the fuel (hydrogen gas) for such fuel-cell power systems as those to be used in the drive systems of advanced motor vehicles. The hydrogen generators would make it unnecessary to rely on any of the hydrogen storage systems developed thus far that are, variously, too expensive, too heavy, too bulky, and/or too unsafe to be practical. The two proposed hydrogen generators are denoted basic and advanced, respectively. In the basic hydrogen generator (see figure), steam at a temperature greater than or equals 330 C would be fed into a reactor charged with magnesium, wherein hydrogen would be released in the exothermic reaction Mg + H2O yields MgO + H2. The steam would be made in a flash boiler. To initiate the reaction, the boiler could be heated electrically by energy borrowed from a storage battery that would be recharged during normal operation of the associated fuel-cell subsystem. Once the reaction was underway, heat from the reaction would be fed to the boiler. If the boiler were made an integral part of the hydrogen-generator reactor vessel, then the problem of transfer of heat from the reactor to the boiler would be greatly simplified. A pump would be used to feed water from a storage tank to the boiler.

Kindler, Andrew↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Geothermal Behavior with Example Simulations on The Treasure Island and UC Berkeley Campus

This submission contains the source code of the Hydrothermal Finite Element Simulator used for the Treasure Island and UC Berkeley campus geothermal simulation. It contains a report that summarizes the development and validation of this Hydrothermal Finite Element Simulator, with a case study on Treasure Island site. It also contains a report that investigates the feasibility of upgrading the existing campus energy delivery system at UC Berkeley to a fifth-generation district heating and cooling system that includes geothermal heat/cold storage.

15 GEOTHERMAL ENERGY↗

Annual report of monitoring at Barnes, Kansas, in 2011

Barnes, Kansas, is a small rural community (population approximately 150) located in Washington County, in north-central Kansas (Figure 1.1). The city lies in a transition zone between the Flint Hills and the glaciated region. The area's topography consists of gently sloping hills of Pleistocene loess (< 20 ft) overlying a shale unit and interbedded shale, limestone, and siltstone of the Permian Chase Group.

54 ENVIRONMENTAL SCIENCES↗

Examining Thermolytic Production of Hydrogen from Lubrication Oil

Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to conduct testing via Technical Task Request (HR) to determine the thermolytic HGR of Mobil SHC™ 630, a lubrication oil. Currently, 35 gallons of contaminated Mobil SHC 630 is proposed for release into the recycle stream from the Defense Waste Processing Facility (DWPF) to Tank 22 and then to the 242-16H (2H) Evaporator system. Inhibited recycle waste in the Recycle Collection Tank (RCT) is transferred to Recycle Pump Tank (RPT) in the Low Point Pump Pit (LPPP) and then to the Concentration, Storage and Transfer Facilities (CSTF) H-area. The lubrication oil would be added directly to the RPT, bypassing the RCT. The current DWPF waste compliance plan for liquid transfers from the RCT to the CSTF limits the concentration of Mobil SHC 630 to <1,100 ppm which is equal to <9.3 gallons of Mobil SHC 630 when considering a 7,500 gal RCT batch with an initial Mobil SHC 630 concentration of 42 mg/L. Mobil SHC 630 is expected to be largely immiscible in the caustic aqueous waste stream. It is a blend of base oils including polyalphaolefin (PAO) base oil and additives such as triphenylphosphate and cresyl diphenyl phosphate at various concentrations (<0.25 wt%). While the base oils are expected to be largely unreactive in CSTF waste, the triarylphosphates additives would be expected to hydrolyze in the caustic waste, forming diarylphosphates and phenol. The tests described herein were governed by a single Run Plan and will determine thermolytic HGR from the caustic aqueous solution, as well as from any organic phases present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗