Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Numerical Analysis of Offshore Wind-Farm-Induced Drag Effects on Coastal Upwelling Dynamics

Wind farms extract momentum from the atmospheric flow, generating wind-speed deficits both within the plant, and extending downstream. When located offshore, these deficits modulate air-sea coupling, potentially impacting coastal upwelling in sensitive regions. We investigate impacts of wind farms on coastal upwelling using kilometre-scale, three-way-coupled simulations with the coupled ocean-atmosphere-wave-sediment transport system for the US West Coast. Wind-farm effects are represented by a generalised turbine drag formulation, an idealised, height-dependent body force whose magnitude is systematically varied. This approach isolates the leading-order fluid-dynamical response in a realistic coastal configuration. The atmospheric adjustment exhibits an approximately linear relation between drag force and wind-speed deficit, with wakes that expand downstream and increase in magnitude as drag increases. An empirical orthogonal function analysis of sea-surface-temperature anomalies reveals the emergence of a canonical dipole pattern under strong drag forcing. Subsurface diagnostics show consistent shoaling of the mixed layer and suppressed upward velocities in areas near wind-farm region, accompanied by compensating enhancements of shoaling closer to the coast. These results identify turbine drag as a control parameter in assessing interactions between wind-farm wake and coastal upwelling and provide scaling relationships for understanding offshore wind-farm effects on the coastal circulation dynamics.

16 TIDAL AND WAVE POWER↗

Behavioral responses of fish to a current-based hydrokinetic turbine under mutliple operational conditions

There is significant international interest in developing current-based marine and hydrokinetic (MHK) technologies to capture the power of tidal energy. However, concerns have been raised regarding the ecological effects of these projects on fish, including the risk of blade collision and behavioral impacts such as the disruption of migratory behavior and food acquisition and displacement from preferred habitats. In this study, we conducted mobile hydroacoustic surveys to track fish as they approached a tidal turbine deployed in Cobscook Bay, Maine. There was a significant decline in fish numbers with decreasing distance to the turbine, beginning approximately 140 m from the turbine. Similar declines were not observed at control transects or when the turbine was not spinning. The decline in fish numbers appeared to be the result of horizontal displacement, not vertical, movements to avoid the turbine. Noise rather than visual cues or flow field disturbance seemed to be a likely explanation for the reduced number of fish near the turbine. This finding, combined with near-field blade collision studies indicating a low probability of encounter, suggests that a single turbine poses a low collision risk to pelagic fish and that a single turbine is likely to result in minimal behavioral responses by fish. However, the risk may be different with additional devices, which will become more relevant as commercial-scale MHK arrays come under consideration. Therefore, the risks associated with commercial-scale operations will ultimately have to be evaluated to fully understand the ecological impacts of MHK devices.

42 ENGINEERING↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular Plasma Microreactor for Intensified Hydrogen Peroxide Production

Sustainable and decentralized manufacturing of hydrogen peroxide (H 2 O 2 ) has been extensively sought to replace the energy- and waste-intensive anthraquinone process. We introduce a helical biphasic microreactor in a coaxial dielectric barrier discharge (DBD) configuration as a modular, adaptable, and scalable intensified unit for H 2 O 2 production. Geometric and operating parameters such as electrode length, applied voltage, and gas and liquid flow rates can be tuned to regulate the residence time, delivered power, and gas–liquid interfacial area. In turn, these affect the key output parameters, i.e., H 2 O 2 concentration, production rate, and energy yield. We found a direct correlation between the H 2 O 2 production rate and the product of the interfacial area and residence time in the plasma region. We investigated the H 2 O 2 formation pathways using DMSO as an ·OH radical scavenger and found that H 2 O 2 forms by the dissolution of gaseous H 2 O 2 at low interfacial areas and is enhanced probably due to the interfacial recombination of ·OH radicals at a large gas–liquid interfacial area. The reactor temperature can also be externally controlled to intensify the production rate and energy yield of H 2 O 2 . Concentrations of up to 33 mM can be attained with a small footprint reactor that features a maximum energy yield of 4 g kWh –1 . Here, the plasma microreactor could epitomize a powerful process intensification tool for sustainable and distributed chemical manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydropower Cyber-Physical Configurations

The U.S. Department of Energy’s Water Power Technologies Office funded Pacific Northwest National Laboratory, Argonne National Laboratory, and the National Renewable Energy Laboratory to develop a typology to characterize the variety and pervasiveness of cyber-physical configurations across the nation’s hydropower fleet. Outreach to owners and operators returned configurations for 275 hydropower plants or approximately 12% of the fleet. Components (OT and IT), systems, and connections among systems differed among plants according to function, age, position in the river cascade, and many other factors. Seven cyber-physical configuration types labeled A through I, included from 2 to dozens of plants. They were differentiated by how pervasive data and control connections were among cyber-physical components and how frequently control signals paired with data signals in a feedback loop. The flow of data and control within each type implies what cybersecurity vulnerabilities may exist, and what mitigation actions may be most effective. A self-assessment approach allows plant operators to identify the configuration type similar to their plant and link to the lessons learned and best practices information. The cyber-physical typology reinforces the idea that hydropower facilities vary widely, but it also identifies groups that highlight similarities in how their cyber-physical components interact. This helps address fleetwide cybersecurity needs by identifying a reasonable number of configuration types that share risks, vulnerabilities, and potential mitigations.

13 HYDRO ENERGY↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Simple and Robust Carrier-Based PWM Technique for Single-Stage Three-phase Rectifier Indirect Matrix Converter

Indirect matrix converters (IMC) can offer high efficiency, high power density, and bidirectional power flow capability with a single-stage three-to single-phase AC-AC power conversion integrating a conventional three-phase active rectifier with a primary side full-bridge inverter of a dual active bridge converter. However, the IMCs generally require space vector modulation techniques, leading to complex sectors and dwell times calculations. A practical implementation of the modulation methods with a commonly used digital signal processor becomes even more challenging when considering power factor correction, harmonics reduction, and deadtime between sector transitions. This paper proposes a simple and robust carrier-based pulse width modulation (PWM) technique determined through a voltage-source inverter (VSI) to current-source inverter (CSI) to IMC conversion. This translation enables the adoption of all conventional VSI control methods with active and reactive power control in the IMCs through simple carrier and reference waveform comparison. The VSI vectors are first one-on-one matched with CSI vectors and translated to IMC modulation signals without calculating sectors and dwell times. Nine different carrier waveforms are proposed, and the converter performance is analyzed. Grid current THD and efficiency are estimated for each modulation method. The symmetric A and B methods had the lowest THD of the grid current, 2.80%, and the efficiency remained at approximately 98.3%, making it the most suitable carrier-based method proposed in this paper. The space vector PWM (SVPWM) modulation method was implemented to the DSP and generated the expected twelve gate signals.

Benson, Mikayla↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Investigation of the Effect of Atmospheric Plasma Treatment in Nanofiber and Nanocomposite Membranes for Piezoelectric Applications

In this work, we report the effect of steady-state atmospheric plasma (Corona discharge) in nanofibers and nanocomposite membranes for piezoelectric applications. The investigation was performed in PVDF (Poly vinylidene fluoride) nanofibers, CNT (Carbon Nanotubes)-reinforced PVDF nanocomposites, and PAN (Poly acrylonitrile) nanofiber membranes. Steady-state plasma was generated with a high voltage power source with 1 mA discharge current output and 6 kV discharge voltage, and the gap between tip and the material was maintained to be 1 cm. For the fabrication of nanofibers and nanocomposite membranes, an electrospinning method was used. The electrospinning parameters, such as flow rate and voltage, were optimally tuned for obtaining uniform nanofibers and nanomembranes. Along with the plasma treatment, heat treatment above the glass transition temperature was also conducted on the nanofiber membranes. Using a Scanning Electron Microscope (SEM), the morphology of the nanofibers was observed. X-ray Diffraction (XRD) demonstrated the polycrystallinity of the nanofibers. Fourier Transform Infrared Spectroscopy (FTIR) analysis of the PVDF nanofibers shows a peak at 796 cm−1 representing α-phase (C-H rocking) in the control sample which is absent in the treated samples. Raman spectroscopy of PVDF nanofibers identifies a Raman shift from 873 cm−1 to 877 cm−1 (denoting β-phase) for plasma-treated samples only. Electron Paramagnetic Resonance (EPR) concludes that the intensity of the free radicals increases from 1.37 to 1.46 (a.u.) after plasma treatment. Then, sensors were fabricated from the PVDF nanofibers, MWCNT-reinforced PVDF nanofibers, and PAN nanofibers to characterize their piezoelectric properties. The impact test results showed that the atmospheric plasma and heat-treated samples had 86%, 277%, and 92% increases of the d33 value (piezoelectric coefficient) in the case of PVDF nanofibers, MWCNT-reinforced nanofibers, and PAN nanofibers, respectively. It was also observed that the capacitance of the nanofiber membranes has increased due to the plasma treatment.

Biochemistry & Molecular Biology↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Electrochemical Control for Corrosion in Molten Chlorides During CSP Plant Operation

The Liquid Pathway of the Concentrating Solar Power Generation 3 (CSP Gen3) program proposed low-cost molten chloride salt for energy storage. However, online corrosion control was identified as a remining major risk of the Liquid Pathway approach. This project addressed that risk. Electrochemical solutions for corrosion mitigation during CSP plant operation were investigated and their feasibility and scalability were evaluated. The leading cause of corrosion in molten chloride salt systems was identified as corrosive impurities that form within the salt upon exposure to trace amounts of air and moisture. Leveraging electrochemistry, reduction/oxidation reactions can be employed to remove these corrosive impurities. In Phase 1 of this project, a bench-scale batch electrochemical reactor was designed, fabricated, and used to assess the kinetics and thermodynamics of electrochemical salt purification. In Phase 2, a laboratory-scale flow reactor was designed, fabricated, and used to assess the efficacy of the electrochemical method under flowing conditions. Results show that under proposed operating conditions for the Liquid Pathway Gen3 Pilot Plant, the electrochemical method is significantly more effective at removing impurities than alternative chemical and thermal methods, and that the electrochemical method produces less harmful byproducts. A key advance made in the course of this project was the development of a 2-electrode method for electrochemical purification that is more scalable than previously developed 3 electrode methods. This novel method is based on Magnesium (Mg) electrowinning. A provisional patent based on this invention has been submitted (USPTO Application No. 63/480,355). Additional key advances made during this project include assessment of the effect of dissimilar alloys on corrosion, kinetic and thermodynamic evaluation of thermolysis reactions of impurities within the molten salt, characterization of byproducts of purification reactions, and generation of IP focused on isolating value-added products using molten salt-based electrochemistry that could be deployed to valorize the process (USPTO Application No. 63/478,806). Ultimately, this project represented a step toward feasibility of Liquid Pathway Gen3 CSP. The method developed under this project could significantly reduce capital expenses and operating costs and increase plant profitability by enabling use of less expensive alloys, decreasing maintenance, and increasing plant longevity. Key focus areas for follow-on work have been identified as 1) evaluation of the efficacy of the electrochemical method under turbulent conditions in a larger flow system, such as the FASTR loop, 2) development of methods for removal of purification byproducts, 3) modeling pilot and industrial scale performance of electrochemical salt purification during plant operation and 4) further assessment of the effect of impurities on salt vapor phase.

14 SOLAR ENERGY↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Real-time Plume Monitoring for Deep Sea Mineral Extraction​

In the emerging industry of deep-sea mining for minerals and deposits (e.g. polymetallic nodules for nickel, cobalt, copper, and manganese), more data is required to understand the effects of sediment plume generation and predict the distribution of disturbed sediment. There are two main sources of plume generation, the first being at the active mining site where the “collector” directly removes the top layer of the sea floor. The other is the “midwater plume” consisting of unwanted sediment that was collected during extraction that is pumped back into the aphotic zone. The vast majority of plume generation is caused by the collector, causing detrimental and long-lasting impacts on seafloor ecosystems due to the lack of wave activity or strong currents at the sea floor. Therefore, it is crucial to invest in the infrastructure to support the study and constant monitoring over a large area of the sea floor where plume generation is present. Due to the limited number of usable channels and power requirements, current subsea wireless communications technologies are not well suited to instrumenting the large areas of the sea floor needed to monitor plume migration. The scope of this effort is to transition experimental demonstrations of high-bandwidth, full-duplex scalable underwater laser communications to the seafloor in an open ocean environment. Specifically tackling challenges associated with the dynamic nature of the subsea world, including but not limited to, deployment logistics, sustainability, and range. The goal is to enable the internet of underwater things for deep sea industries by broadening the capabilities of subsea communications. By using high-precision laser transmitters, many of the challenges current subsea optical systems face can be circumvented, such as power consumption, interference, and bandwidth limitations. This approach lends itself to wireless interlinking multi-node networks, in series or parallel, facilitating the implementation of a wide array of sensor types. This interlinking allows all the data gathered from the network to be processed through a single hardline uplink to the surface, lowering the complexity required for near real-time data processing. Additionally, the laser control systems produce metadata that can be used to help characterize the water column between the nodes. Combining data from various sensors such as turbidity, temperature, current velocity with metadata such as beam attenuation and deflection can produce a high-resolution model of sea floor conditions around an active mining zone. The resulting near real-time model can be used to optimize location and flow rate of the mining operation to minimize and quantify the environmental impact.

Mons, Ishan↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗