Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Identifying Optimal Temporal Scale for the Correlation of AOD and Ground Measurements of PM2.5 to Improve the Modeling Performance in a Real-Time Air Quality Estimation System

Aerosol optical depth (AOD), derived from satellite measurements using Moderate Resolution Imaging Spectrometer (MODIS), offers indirect estimates of particle matter. Research shows a significant positive correlation between satellite-based measurements of AOD and ground-based measurements of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM2.5). In addition, satellite observations have also shown great promise in improving estimates of PM2.5 air quality surface. Research shows that correlations between AOD and ground PM2.5 are affected by a combination of many factors such as inherent characteristics of satellite observations, terrain, cloud cover, height of the mixing layer, and weather conditions, and thus might vary widely in different regions, different seasons, and even different days in a same location. Analysis of correlating AOD with ground measured PM2.5 on a day-to-day basis suggests the temporal scale, a number of immediate latest days for a given run's day, for their correlations needs to be considered to improve air quality surface estimates, especially when satellite observations are used in a real-time pollution system. The second reason is that correlation coefficients between AOD and ground PM2.5 cannot be predetermined and needs to be calculated for each day's run for a real-time system because the coefficients can vary over space and time. Few studies have been conducted to explore the optimal way to apply AOD data to improve model accuracies of PM2.5 surface estimation in a real-time air quality system. This paper discusses the best temporal scale to calculate the correlation of AOD and ground particle matter data to improve the results of pollution models in real-time system.

Li,Hui↗

Heavy Ozone Enrichment from ATMOS Infrared Solar Spectra

Vertical enrichment profiles of stratospheric ozone with oxygen 18 in the second or third position have been derived from space- based solar occultation spectra recorded at 0.01/cm resolution with the ATMOS (Atmospheric Trace Molecule Spectroscopy) Fourier- transform infrared (FTIR) spectrometer.

ozone↗

Systems and methods for vehicle cruise speed recommendation

A method for providing a cruising speed recommendation to an operator of a vehicle includes determining a projected route; receiving route characteristic data including route elevation data; determining a sampling resolution; sampling the route elevation data at the sampling resolution to generate sampled route elevation data; determining at least one start of uphill position and at least one start of downhill position; determining at least one cruise speed route segment based at least in part on the at least one start of uphill position and the at least one start of downhill position; determining a corresponding cruising speed for the at least one cruise speed route segment based at least in part on one or more of the route elevation data and the sampled route elevation data; and communicating the corresponding cruising speed for the at least one cruise speed route segment.

Aggoune, Karim↗

High Angular Resolution Gravitational Wave Astronomy

Since the very beginning of astronomy the location of objects on the sky has been a fundamental observational quantity that has been taken for granted. While precise two dimensional positional information is easy to obtain for observations in the electromagnetic spectrum, the positional accuracy of current and near future gravitational wave detectors is limited to between tens and hundreds of square degrees, which makes it extremely challenging to identify the host galaxies of gravitational wave events or to detect any electromagnetic counterparts. Gravitational wave observations provide information on source properties that is complementary to the information in any associated electromagnetic emission. Observing systems with multiple messengers thus has scientific potential much greater than the sum of its parts. A gravitational wave detector with higher angular resolution would significantly increase the prospects for finding the hosts of gravitational wave sources and triggering a multi-messenger follow-up campaign. An observatory with arcminute precision or better could be realised within the Voyage 2050 programme by creating a large baseline interferometer array in space and would have transformative scientific potential. Precise positional information of standard sirens would enable precision measurements of cosmological parameters and offer new insights on structure formation; a high angular resolution gravitational wave observatory would allow the detection of a stochastic background and resolution of the anisotropies within it; it would also allow the study of accretion processes around black holes; and it would have tremendous potential for tests of modified gravity and the discovery of physics beyond the Standard Model.

Gravitational waves↗

AI-3000K Infrared Line List for Hot CO 2

AI-3000K is a semi-empirical IR line list constructed for hot CO 2 spectra analysis and simulation up to 3000 – 4000 K. Compared to previously published Ames-1000K and UCL-4000, it represents a major upgrade, utilizing a new algorithm for optimization and including the latest improvements in potential energy surface (PES), dipole moment surface (DMS), and room temperature IR line list (Ames-2021 296K). To maximize the success of introducing experimental based accurate line positions, a new PES (X01d) was refined with respect to >800 selected CDSD2019 [Tashkun et al. JQSRT (2019) 228, 124] energy levels in the range of 0 – 24,000 cm -1 , with σ rms = 0.5 – 0.7 cm -1 . Most differences between the X01d PES based levels and CDSD2019 energies are within ± 2 cm -1 . A new DMS is fitted from extrapolated CCSD(T)/aug-cc-pV(T,Q,5)Z dipole calculations, with σ rms = 5.1 × 10 -6 au for 11,155 geometries up to 40,000 cm -1 , denoted Ames-2021–40K. Compared to the best available Ames-2021 DMS and room temperature IR line list [Huang et al J. Phys. Chem. A (2022) 126, 5940], the relative intensity differences are expected to be ∼ 1 ‰. The line position accuracy of ''X01d + Ames-2021–40K'' IR line list is significantly improved by adopting CDSD2019 energy levels up to 24,000 cm -1 (J ≤ 150). The Einstein A21 coefficients for E' < 15,000 cm -1 transitions are replaced by more accurate values from the Ames-2021 296K IR line list. In short, the AI-3000K is the X01d PES and Ames-2021–40K DMS based line list enhanced with the A 21 of Ames-2021 296K line list and CDSD energy levels. It provides continuous coverage from 0 to 20,000 cm -1 for the four most abundant isotopologues: 12 C 16 O 2 (626), 13 C 16 O 2 (636), 16 O 12 C 18 O (628), and 16 O 12 C 17 O (627). The impacts of isotopologue and E'/E'' cutoffs have been examined. Intensity convergence (not accuracy) of AI-3000K line list is quantitatively estimated in 1 cm -1 bins. It is better than 99% in the whole range of 0 – 20,000 (or 10,000) cm -1 at 1000 K (or 2000 K), or better than 90% in the whole range of 0 – 15,000 (or 9000) cm -1 at 2000 K (or 3000 K), respectively. Convergence beyond 3000 K will require a new PES and DMS for E' > 40,000 cm -1 . The AI-3000K and HITEMP based IR simulations are compared to high resolution shock tube experiments for CO 2 -Ar mixture up to 2000 K. With line position accuracy comparable to that of HITEMP, AI-3000K IR line list yields better agreements at more frequencies. Potential sources of discrepancies with experiment are discussed.

AI-3000K↗

Subpixel resolution from multiple images

Multiple images taken from similar locations and under similar lighting conditions contain similar, but not identical, information. Slight differences in instrument orientation and position produces mismatches between the projected pixel grids. These mismatches ensure that any point on the ground is sampled differently in each image. If all the images can be registered with respect to each other to a small fraction of a pixel accuracy, then the information from the multiple images can be combined to increase linear resolution by roughly the square root of the number of images. In addition, the gray-scale resolution of the composite image is also improved. We describe methods for multiple image registration and combination, and discuss some of the problems encountered in developing and extending them. We display test results with 8:1 resolution enhancement, and Viking Orbiter imagery with 2:1 and 4:1 enhancements.

Cheeseman, Peter↗

Terrain-aided position determination using range angle radar altimetry

Various embodiments described herein provide for a terrain-aided location determination using a range/angle radar altimetry. Range/angle radar systems use vertical synthetic aperture radar measurements which do not include any cross-track resolution, such that if a range/Doppler cloud from a single VSAR image is compared to a regular DEM, there can be ambiguity in determining the cross-track position. By modifying the DEM to inherently include additional terrain signature information that could be compared to VSAR measurement, the limitation can be overcome, and a single range/angle radar system can provide an accurate position without the additional complexity of a range/angle/angle radar system.

Sloan, George R.↗

Absolute integrated intensity and individual line parameters for the 6.2-micron band of NO2

The absolute integrated intensity of the 6.2-micron band of NO2 at 40 C was determined from quantitative spectra at about 10 per cm resolution by the spectral band model technique. A value of 1430 plus or minus 300 per sq cm per atm was obtained. Individual line parameters, positions, intensities, and ground-state energies were derived, and line-by-line calculations were compared with the band model results and with the quantitative spectra obtained at about 0.5 per cm resolution.

Goldman, A.↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

Studies of the field-of-view resolution tradeoff in virtual-reality systems

Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

Piantanida, Thomas P.↗

Isotopologue Consistency of Semi-Empirically Computed InfraRed Line Lists and Further Improvement for Rare Isotopologues: CO2 and SO2 Case Studies.

The semi-empirical molecular rovibrational IR line lists, such as ExoMol, TheoReTs, and Ames, combine the experimental accuracy and theoretical power to reach better than 0.1 cm-1 accuracy for line positions and better than 80-90% agreement for line intensities. The quality of these existing semi-empirical IR lists allows further improvements of intensity and line positions for those unobserved minor isotopologues. This paper presents our new BTRHE (Best Theory + Reliable High-resolution Experiment) strategy implementation. For line intensity, the isotopologue consistency and the patterns of mass dependence in the Ames-296K SO2 and CO2 IR lists are quantitatively presented along the mass-inverse coordinates. The consistency and patterns are better than those in existing experimental data. The methodology proposed here can be used to identify inconsistencies, outliers, and mistakes in intensities, and help improve Effective Dipole Model (EDM) and molecular IR databases. We call for an experimental study on the 50006 and 60007 bands of CO2 628. For line position predictions, a simple approach combining the variational IR line lists with Effective Hamiltonian (EH) model may refine the effective rotational constants A0/B0/C0 and quartic centrifugal distortion constants of minor isotopologues. The prediction accuracy may be improved by two orders of magnitude, i.e. reaching 0-5 MHz prediction accuracy in the range of J<20-30, Ka<10-20, and 0.01-0.02 MHz accuracy for A0/B0/C0. Several important factors have been systematically investigated and discussed, e.g. convergence, uncertainties, higher order terms, fixing EH parameters, mass coordinates, etc. Amicrowave (MW) line set consisting of 644,636 strong transitions for all 30 isotopologues and corresponding refined EH(Ames) parameters are reported in the supplementary material. This approach may be easily extended to rovibrational bands, hot bands, and other molecular systems.

Xinchuan Huang↗

Correlation of Kp with the substorm-injected plasma boundary

The local time position of the low-energy substorm-injected plasma boundary in the dusk to midnight region of the magnetosphere as observed by the geostationary satellite ATS 5 is found to be correlated with the interpolated Kp index. Considering the time resolution of Kp, the correlation is found to be quite close but dependent on season. An estimate of the overall shape and position of the low-energy boundary within this region of the magnetosphere as a function of Kp is found by using a fit to the authors' winter data correlation in conjunction with a fit of data presented by Carpenter (1967) concerning the Kp-related radial positioning of the plasmapause boundary in the postmidnight region. This analysis results in a spiral structure, the scale of which depends on Kp.

Mauk, B. H.↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

T-Slide Linear Actuators

T-slide linear actuators use gear bearing differential epicyclical transmissions (GBDETs) to directly drive a linear rack, which, in turn, performs the actuation. Conventional systems use a rotary power source in conjunction with a nut and screw to provide linear motion. Non-back-drive properties of GBDETs make the new actuator more direct and simpler. Versions of this approach will serve as a long-stroke, ultra-precision, position actuator for NASA science instruments, and as a rugged, linear actuator for NASA deployment duties. The T slide can operate effectively in the presence of side forces and torques. Versions of the actuator can perform ultra-precision positioning. A basic T-slide actuator is a long-stroke, rack-and-pinion linear actuator that, typically, consists of a T-slide, several idlers, a transmission to drive the slide (powered by an electric motor) and a housing that holds the entire assembly. The actuator is driven by gear action on its top surface, and is guided and constrained by gear-bearing idlers on its other two parallel surfaces. The geometry, implemented with gear-bearing technology, is particularly effective. An electronic motor operating through a GBDET can directly drive the T slide against large loads, as a rack and pinion linear actuator, with no break and no danger of back driving. The actuator drives the slide into position and stops. The slide holes position with power off and no brake, regardless of load. With the T slide configuration, this GBDET has an entire T-gear surface on which to operate. The GB idlers coupling the other two T slide parallel surfaces to their housing counterpart surfaces provide constraints in five degrees-of-freedom and rolling friction in the direction of actuation. Multiple GB idlers provide roller bearing strength sufficient to support efficient, rolling friction movement, even in the presence of large, resisting forces. T-slide actuators can be controlled using the combination of an off-the-shelf, electric servomotor, a motor angle resolution sensor (typically an encoder or resolver), and microprocessor-based intelligent software. In applications requiring precision positioning, it may be necessary to add strain gauges to the T-slide housing. Existing sensory- interactive motion control art will work for T slides. For open-loop positioning, a stepping motor emulation technique can be used.

Vranish, John↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

Geometrical analysis of Cys-Cys bridges in proteins and their prediction from incomplete structural information

Analysis of C-alpha atom positions from cysteines involved in disulphide bridges in protein crystals shows that their geometric characteristics are unique with respect to other Cys-Cys, non-bridging pairs. They may be used for predicting disulphide connections in incompletely determined protein structures, such as low resolution crystallography or theoretical folding experiments. The basic unit for analysis and prediction is the 3 x 3 distance matrix for Cx positions of residues (i - 1), Cys(i), (i +1) with (j - 1), Cys(j), (j + 1). In each of its columns, row and diagonal vector--outer distances are larger than the central distance. This analysis is compared with some analytical models.

NASA Discipline Exobiology↗

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

DMSP-SSM/1 NASA algorithm validation using primarily LANDSAT and secondarily DMSP and/or AVHRR visible and thermal infrared satellite imagery

The approach to the DMSP SSMI (Defense Meteorological Satellite Program; Special Sensor Microwave Imager) sea-ice validation effort is to demonstrate a quantitative relationship between the SSMI-derived sea ice parameters and those same parameters derived from other data sets including visible and infrared satellite imagery, aerial photographic and high-resolution microwave aircraft imagery. The question to be addressed is to what accuracy (relative to these other observations) can the following ice parameters be determined: (1) position of the ice boundary; (2) total sea ice concentration; and (3) multiyear sea ice concentration. Specific tasks include: (1) a study of the interrelationship of surface information content and sensor spatial and spectral resolution in order to establish relationships between ice surface features and the manner in which they are expressed in the satellite observations; and (2) apply these relationships to map the sea ice features which can be used to evaluate NASA's proposed SSM/1 sea ice algorithms. Other key points to be addressed include the accuracy to which these parameters can be determined in different regions (marginal ice zone such as Bering Sea, Arctic ocean, such as Beaufort Sea); the accuracy of these parameters for different seasons; the accuracy of the algorithms weather filter under different weather conditions; and the effectiveness of the 85.5 GHz channels to locate the ice edge.

Steffen, K.↗