Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

{gamma}-ray polarization constraints on Planck scale violations of special relativity

Using recent polarimetric observations of the Crab Nebula in the hard X-ray band by INTEGRAL, we show that the absence of vacuum birefringence effects constrains O(E/M) Lorentz violation in QED to the level |{xi}|<9x10{sup -10} at 3{sigma} CL, tightening by more than 3 orders of magnitude previous constraints. We show that planned X-ray polarimeters have the potential to probe |{xi}|{approx}10{sup -16} by detecting polarization in active galaxies at red-shift {approx}1.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and performance of Soft Gamma-ray Detector onboard the Hitomi (ASTRO-H) satellite

Hitomi (ASTRO-H) was the sixth Japanese x-ray satellite that carried instruments with exquisite energy resolution of <7 eV and broad energy coverage of 0.3 to 600 keV. The Soft Gamma-ray Detector (SGD) was the Hitomi instrument that observed the highest energy band (60 to 600 keV). The SGD design achieves a low background level by combining active shields and Compton cameras where Compton kinematics is utilized to reject backgrounds coming from outside of the field of view. A compact and highly efficient Compton camera is realized using a combination of silicon and cadmium telluride semiconductor sensors with a good energy resolution. Compton kinematics also carries information for gamma-ray polarization, making the SGD an excellent polarimeter. Following several years of development, the satellite was successfully launched on February 17, 2016. After proper functionality of the SGD components were verified, the nominal observation mode was initiated on March 24, 2016. The SGD observed the Crab Nebula for approximately two hours before the spacecraft ceased to function on March 26, 2016. We present concepts of the SGD design followed by detailed description of the instrument and its performance measured on ground and in orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the polarization correlation parameter C{sub nn} in the pp elastic scattering with an unpolarized proton target and an unpolarized 1-GeV proton beam

The polarization correlation parameter C{sub nn} in the elastic proton-proton scattering was for the first time measured with a high statistical accuracy at 1 GeV using an unpolarized proton beam incident on an unpolarized proton target. Both outgoing protons from the reaction were detected in coincidence by means of a two-arm focusing magnetic spectrometer installed at nonsymmetric angles corresponding to the center-of-mass scattering angle {Theta}{sub cm} = 62.25{sup o}. The correlation parameter C{sub nn}, as well as polarizations P{sub 1} and P{sub 2} of the secondary protons, were measured by means of multiwire proportional chamber polarimeters placed at the focal planes of each spectrometer arm. The obtained data are compared with the predictions of the phase-shift analysis. The connection with the experiment on C{sub nn} and polarization measurements in the (p, 2p) reaction on {sup 4}He and other light nuclei in similar kinematics is discussed

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarization effects in the quasielastic (p, 2p) reaction with the nuclear S-Shell Protons at 1 GeV

The polarization of the secondary protons in the (p, 2p) reaction with the S-shell protons of nuclei {sup 4}He, {sup 6}Li, {sup 12}C, {sup 28}Si, {sup 40}Ca was measured at 1 GeV unpolarized proton beam. The spin correlation parameters C{sub ij} for the {sup 4}He and {sup 12}C targets also were for the first time obtained as well. The polarization measurements were performed by means of a two-arm magnetic spectrometer, each arm of which was equipped with the multiwire-proportional chamber polarimeter. This experiment was aimed to study a modification of the proton-proton scattering matrix in the nuclear medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure effects in polarization and cross sections for A(p, p’)X inelastic reactions on {sup 40}Ca and {sup 12}C nuclei at 1 GeV

The polarization of secondary protons in the (p, p’) inelastic reactions on {sup 40}Ca and {sup 12}C nuclei at the initial proton energy of 1 GeV was measured over a wide range of scattered-proton momenta at a laboratory angle of Θ = 21°. The reaction cross sections were also measured. Scattered protons were detected by means of magnetic spectrometer equipped with a polarimeter based on multiwire-proportional chambers. A structure in the polarization and cross-section data, which is probably related to scattering off nucleon correlations in the nuclei involved, was observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of Inelastic A(p, p′)X Reaction with Nuclei at 1 GeV

The secondary-proton polarization and differential cross sections for the (p, p') inelastic reaction on {sup 28}Si and {sup 56}Fe nuclei at the initial proton energy of 1 GeV were measured over a wide range of the scattered-proton momenta at a laboratory angle of Θ = 21◦. Scattered protons were detected by means of a magnetic spectrometer equipped with a polarimeter based on multiwire proportional chambers and a carbon analyzer. A structure in the polarization and cross section data, which is probably related to quasielastic scattering off nucleon correlations in the {sup 28}Si and {sup 56}Fe nuclei, was observed as earlier in the analogous data for {sup 12}C and {sup 40}Ca nuclei. Momentum intervals within which cross-section ratios for nuclei did not depend on the scattered-proton momentum were found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of optical constants for uranium from 10 to 47 nm

We use a laser high-harmonics-based extreme-ultraviolet (EUV) polarimeter to determine the optical constants of elemental uranium in the wavelength range from 10 to 47 nm. The constants are extracted from the measured ratio of p-polarized to s-polarized reflectance from a thin uranium film deposited in situ. The film thickness is inferred from a spectroscopic ellipsometry measurement of the sample after complete oxidation in room air. Uranium has been used as a high-reflectance material in the EUV. However, difficulties with oxidation prevented its careful characterization previous to this study. We find that measured optical constants for uranium vary significantly from previous estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Two-Column Aerosol Project (TCAP) Science Plan

The Two-Column Aerosol Project (TCAP) field campaign will provide a detailed set of observations with which to (1) perform radiative and cloud condensation nuclei (CCN) closure studies, (2) evaluate a new retrieval algorithm for aerosol optical depth (AOD) in the presence of clouds using passive remote sensing, (3) extend a previously developed technique to investigate aerosol indirect effects, and (4) evaluate the performance of a detailed regional-scale model and a more parameterized global-scale model in simulating particle activation and AOD associated with the aging of anthropogenic aerosols. To meet these science objectives, the Atmospheric Radiation Measurement (ARM) Climate Research Facility will deploy the ARM Mobile Facility (AMF) and the Mobile Aerosol Observing System (MAOS) on Cape Cod, Massachusetts, for a 12-month period starting in the summer of 2012 in order to quantify aerosol properties, radiation, and cloud characteristics at a location subject to both clear and cloudy conditions, and clean and polluted conditions. These observations will be supplemented by two aircraft intensive observation periods (IOPs), one in the summer and a second in the winter. Each IOP will deploy one, and possibly two, aircraft depending on available resources. The first aircraft will be equipped with a suite of in situ instrumentation to provide measurements of aerosol optical properties, particle composition and direct-beam irradiance. The second aircraft will fly directly over the first and use a multi-wavelength high spectral resolution lidar (HSRL) and scanning polarimeter to provide continuous optical and cloud properties in the column below.

54 ENVIRONMENTAL SCIENCES↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗

Design of a New Optical System for Alcator C-Mod Motional Stark Effect Diagnostic

The motional Stark effect (MSE) diagnostic on Alcator C-Mod uses an in-vessel optical system (five lenses and three mirrors) to relay polarized light to an external polarimeter because port access limitations on Alcator C-Mod preclude a direct view of the diagnostic beam. The system experiences unacceptable, spurious drifts of order several degrees in measured pitch angle over the course of a run day. Recent experiments illuminated the MSE diagnostic with polarized light of fixed orientation as heat was applied to various optical elements. A large change in measured angle was observed as two particular lenses were heated, indicating that thermal-stress-induced birefringence is a likely cause of the spurious variability. Several new optical designs have been evaluated to eliminate the affected in-vessel lenses and to replace the focusing they provide with curved mirrors; however, ray tracing calculations imply that this method is not feasible. A new approach is under consideration that utilizes in situ calibrations with in-vessel reference polarized light sources. 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q 2

Experiment E08-007 measured the proton elastic form factor ratio μ p G E /G M in the range of Q 2 = 0.3-0.7(GeV/c) 2 by recoil polarimetry. Data were taken in 2008 at the Thomas Jefferson National Accelerator Facility in Virginia, USA. A 1.2 GeV polarized electron beam was scattered off a cryogenic hydrogen target. The recoil proton was detected in the left HRS in coincidence with the elasticly scattered electrons tagged by the BigBite spectrometer. The proton polarization was measured by the focal plane polarimeter (FPP). In this low Q 2 region, previous measurement from Jefferson Lab Hall A (LEDEX) along with various fits and calculations indicate substantial deviations of the ratio from unity. For this new measurement, the proposed statistical uncertainty (< 1%) was achieved. These new results are a few percent lower than expected from previous world data and fits, which indicate a smaller G Ep at this region. Beyond the intrinsic interest in nucleon structure, the new results also have implications in determining the proton Zemach radius and the strangeness form factors from parity violation experiments.

08 HYDROGEN↗

Recoil Polarization Measurements of the Proton Electromagnetic Form Factor Ratio to High Momentum Transfer

The electromagnetic form factors of the nucleon characterize the effect of its internal structure on its response to an electromagnetic probe as studied in elastic electronnucleon scattering. These form factors are functions of the squared four-momentum transfer Q 2 between the electron and the proton. The two main classes of observables of this reaction are the scattering cross section and polarization asymmetries, both of which are sensitive to the form factors in different ways. When considering large f momentum transfers, double-polarization observables offer superior sensitivity to the electric form factor. This thesis reports the results of a new measurement of the ratio of the electric and magnetic form factors of the proton at high momentum transfer using the recoil polarization technique. A polarized electron beam was scattered from a liquid hydrogen target, transferring polarization to the recoiling protons. These protons were detected in a magnetic spectrometer which was used to reconstruct their kinematics, including their scattering angles and momenta, and the position of the interaction vertex. A proton polarimeter measured the polarization of the recoiling protons by measuring the azimuthal asymmetry in the angular distribution of protons scattered in CH 2 analyzers. The scattered electron was detected in a large acceptance electromagnetic calorimeter in order to suppress inelastic backgrounds. The measured ratio of the transverse and longitudinal polarization components of the scattered proton is directly proportional to the ratio of form factors G p E =G p M . The measurements reported in this thesis took place at Q 2 =5.2, 6.7, and 8.5 GeV 2 , and represent the most accurate measurements of G p E in this Q 2 region to date.

08 HYDROGEN↗

OBSERVATION OF A QUASIPERIODIC PULSATION IN HARD X-RAY, RADIO, AND EXTREME-ULTRAVIOLET WAVELENGTHS

We present a multiwavelength analysis of a quasiperiodic pulsation (QPP) observed in the hard X-ray (HXR), radio, and extreme-ultraviolet (EUV) channels during an M1.9 flare that occurred on 2011 September 23–24. The nonthermal HXR emission in 25–50 keV observed by RHESSI shows five distinct impulsive peaks of decaying amplitude with a period of about 3 minutes. A similar QPP was observed in the microwave emission recorded by the Nobeyama Radioheliograph and Polarimeter in the 2, 3.75, 9.4, and 17 GHz channels. Interestingly, the 3-minute QPP was also observed in the metric and decimetric radio frequencies (25–180, 245, 610 MHz) as repetitive type III bursts. Multiwavelength observations from the Solar Dynamics Observatory /Atmospheric Image Assembly, Hinode /SOT, and Solar TErrestrial RElations Observatory /SECCHI suggest a fan-spine topology at the eruption site, associated with the formation of a quasi-circular ribbon during the flare. A small filament was observed below the fan loops before the flare onset. The filament rose slowly and interacted with the ambient field. This behavior was followed by an untwisting motion of the filament. Two different structures of the filament showed an approximately 3-minute periodic alternate rotation in the clockwise and counterclockwise directions. The 3-minute QPP was found to highly correlate with 3-minute oscillations in a nearby sunspot. We suggest that the periodic reconnection (modulated either by a sunspot slow-mode wave or by an untwisting filament) at a magnetic null point most likely causes the repetitive particle acceleration, generating the QPP observed in HXR, microwave, and type III radio bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

A GLOBAL VIEW OF VELOCITY FLUCTUATIONS IN THE CORONA BELOW 1.3 R {sub ⊙} WITH CoMP

The Coronal Multi-channel Polarimeter (CoMP) has previously demonstrated the presence of Doppler velocity fluctuations in the solar corona. The observed fluctuations are thought to be transverse waves, i.e., highly incompressible motions whose restoring force is dominated by the magnetic tension, some of which demonstrate clear periodicity. We aim to exploit CoMP’s ability to provide high cadence observations of the off-limb corona to investigate the properties of velocity fluctuations in a range of coronal features, providing insight into how (whether) the properties of the waves are influenced by the varying magnetic topology in active regions, quiet Sun and open field regions. An analysis of Doppler velocity time-series of the solar corona from the 10747 Å Iron xiii line is performed, determining the velocity power spectrum and using it as a tool to probe wave behavior. Further, the average phase speed and density for each region are estimated and used to compute the spectra for energy density and energy flux. In addition, we assess the noise levels associated with the CoMP data, deriving analytic formulae for the uncertainty on Doppler velocity measurements and providing a comparison by estimating the noise from the data. It is found that the entire corona is replete with transverse wave behavior. The corresponding power spectra indicate that the observed velocity fluctuations are predominately generated by stochastic processes, with the spectral slope of the power varying between the different magnetic regions. Most strikingly, all power spectra reveal the presence of enhanced power occurring at ∼3 mHz, potentially implying that the excitation of coronal transverse waves by p -modes is a global phenomenon.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-infrared Polarimetric Study of the N159/N160 Star-forming Complex in the Large Magellanic Cloud

We present near-infrared polarimetric results for the N159/N160 star-forming complex in the Large Magellanic Cloud with SIRPOL, the polarimeter of the Infrared Survey Facility. We separated foreground sources using their visual extinction derived from near-infrared photometric data. The 45 young stellar candidates and 2 high-excitation blobs were matched with our sources, and 12 of them showed high polarization that did not originate from the interstellar dust. We made a polarimetric catalog of 252, 277, and 89 sources at the J, H, and K {sub s} bands, respectively. Based on the ratios of the polarization degree between these bands, we verify that the origin of these polarized sources is the dichroic extinction from the interstellar dust aligned by the magnetic field and that the ratios follow a power-law dependence of P{sub λ} ∼ λ{sup −0.9}. The linear polarization vectors projected onto the Hα image of the complex turned out to follow the local magnetic field structure. The vector map overlaid on dust and gas emissions shows the close correlation between the magnetic field structure and surrounding interstellar medium. We suggest that the derived magnetic field structure supports the sequential formation scenario of the complex.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility of Observing Gamma-Ray Polarization from Cygnus X-1 Using a CubeSat

Instruments flown on CubeSats are small. Meaningful applications of CubeSats in astronomical observations rely on the choice of a particular subject that is feasible for CubeSats. Here we report the result of a feasibility study for observing gamma-ray polarization from Cygnus X-1 using a small Compton polarimeter on board a 3U CubeSat. Silicon detectors and cerium bromide scintillators were employed in the instrument models that we discuss in this study. Through Monte Carlo simulations with a Geant4-based MEGAlib package, we found that, with a 10 Ms on-axis, zenith-direction observation in a low-inclination, low-altitude, Earth-orbit radiation background environment, the minimum detectable polarization degree can be down to about 10% in 160–250 keV, 20% in 250–400 keV, and 65% in 400–2000 keV. A 3U CubeSat dedicated to observing Cygnus X-1 can therefore yield useful information on the polarization state of gamma-ray emissions from the brightest persistent X-ray black hole binary in the sky.

79 ASTRONOMY AND ASTROPHYSICS↗

A Search for Polarized Thermal Emission from Directly Imaged Exoplanets and Brown Dwarf Companions to Nearby Stars

Aerosols in the atmospheres of cloudy gas giant exoplanets and brown dwarfs scatter and polarize these objects’ thermal emission. If such an object has an oblate shape or nonuniform cloud distribution, the net degree of linear polarization can show an increase ranging from several tenths of a percent to a few percent. Modern high-contrast imaging polarimeters are now poised to detect such low-polarization signals, opening up a new window into the rotational velocities and cloud properties of substellar companions to nearby stars. In this paper, we present the results of a near-IR survey searching for linearly polarized thermal emission from a sample of two planetary-mass companions and five brown dwarf companions using GPI and SPHERE-IRDIS. We probe the subpercent linear polarization regime that typifies polarized free-floating brown dwarfs and place limits on each object’s degree of linear polarization. We relate our upper limits on each target’s degree of linear polarization to its rotation rate, and place our results in the context of rotation rates measured using high-resolution spectroscopy.

79 ASTRONOMY AND ASTROPHYSICS↗