Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Poisson Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Investigation of Ion-Implanted Photosensitive Silicon Structures by Electrochemical Capacitance–Voltage Profiling

The method of electrochemical capacitance–voltage profiling is used to study boron-implanted silicon structures for CCD matrices with backside illumination. A series of specially prepared structures with different energies and doses of ion implantation and also with various materials used for the coating layers (aluminum, silicon oxide, and their combinations) is studied. The profiles of the depth distribution of majority charge carriers of the studied structures are obtained experimentally. Also, using the Poisson equation and the Fredholm equation of the first kind, the distributions of the charge-carrier concentration and of the electric field in the structures are calculated. On the basis of the analysis and comparison of theoretical and experimental concentration profiles, recommendations concerning optimization of the structures’ parameters in order to increase the value of the pulling field and decrease the effect of the surface potential on the transport of charge carriers are suggested.

36 MATERIALS SCIENCE↗

Lensed cosmic microwave background constraints on post-general-relativity parameters

The constraints on departures from general relativity (GR) at cosmological length scales due to cosmic microwave background (CMB) data are discussed. The departure from GR is measured by the ratio, parametrized as 1+{pi}{sub 0}(1+z){sup -S}, between the gravitational potentials conventionally appearing in the geodesic equation and the Poisson equation. Current CMB data indicate {pi}{sub 0}=1.67{sub -1.87}{sup +3.07} at the 2{sigma} confidence level, while S remains unconstrained. The departure from GR affects the lensing conversion of E-mode into B-mode polarization. Hence, the lensing measurements from CMBpol alone should be able to improve the constraint to {pi}{sub 0}<0.52 (2{sigma}) for a fiducial {pi}{sub 0}=0 model independent of S.

99 GENERAL AND MISCELLANEOUS↗

MCNP6 Modification for the Calculation of Rossi and Feynman Distributions

The Rossi distribution is given by the number of captured neutron pairs as a function of the time interval between the two capture events. This distribution contains a random part, which is given by neutron captures caused by neutrons of different fission chains, and a correlated part, which is given by neutron captures caused by neutrons from the same fission chain. The correlated part exponentially vanishes with the {Delta}t time interval following the decay of prompt neutrons. The Rossi distribution peaks when the time interval between two capture events is small since this condition is satisfied for neutrons generated from the same fission chain. In the Poisson probability distribution, the variance is equal to the mean and the next event probability is independent of the elapsed time since the previous event. Neutron captures events do not follow the Poisson probability distribution because they are correlated events via fission chains. Consequently, the Feynman distribution Y is defined as the variance to mean ratio minus one, of the neutron counts array as a function of a fixed time interval. The MCNP6 source code has been modified to allow the calculation of the Rossi and Feynman distributions. The source code modification takes into account the time when a neutron is emitted by the external neutron source and gives a precision in the timestamp lower than a fraction of nanosecond. The modified MCNP6 version has been used to model KUKA facility driven by a californium neutron source. The prompt neutron decay constants obtained by the Rossi and Feynman methods are in agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Casimir meets Poisson: improved quark/gluon discrimination with counting observables

Charged track multiplicity is among the most powerful observables for discriminating quark- from gluon-initiated jets. Despite its utility, it is not infrared and collinear (IRC) safe, so perturbative calculations are limited to studying the energy evolution of multiplicity moments. While IRC-safe observables, like jet mass, are perturbatively calculable, their distributions often exhibit Casimir scaling, such that their quark/gluon discrimination power is limited by the ratio of quark to gluon color factors. In this paper, we introduce new IRC-safe counting observables whose discrimination performance exceeds that of jet mass and approaches that of track multiplicity. The key observation is that track multiplicity is approximately Poisson distributed, with more suppressed tails than the Sudakov peak structure from jet mass. By using an iterated version of the soft drop jet grooming algorithm, we can define a “soft drop multiplicity” which is Poisson distributed at leading-logarithmic accuracy. In addition, we calculate the next-to-leading-logarithmic corrections to this Poisson structure. If we allow the soft drop groomer to proceed to the end of the jet branching history, we can define a collinear-unsafe (but still infrared-safe) counting observable. Exploiting the universality of the collinear limit, we define generalized fragmentation functions to study the perturbative energy evolution of collinear-unsafe multiplicity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Early-time plasma expansion characteristics of ionized clouds in the ionosphere

A series of Vlasov-Poisson simulations were conducted with barium and lithium gas mixtures expanding into an O(+) background plasma, with the values for the Ba(+)/Li(+) composition ratios and the cloud/background density ratios based on anticipated release values in the upcoming Combined Release and Radiation Effects Satellite (CRRES) experiment. The results obtained on the early-time expansion of high-density Ba(+), Li(+), and Ba(+)-Li(+) plasma clouds into low-density O(+) background plasma complement the H(+)-O(+) expansions of Gurevich et al. (1973) and Singh and Schunk (1982, 1983), and the characteristic features observed apply to the very-early-time expansion phase of the CRRES releases.

Schunk, R. W.↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Atom-partitioned multipole expansions for electrostatic potential boundary conditions

Applications such as grid-based real-space density functional theory (DFT) use the Poisson equation to compute electrostatics. However, the expected long tail of the electrostatic potential requires either the use of a large and costly outer domain or Dirichlet boundary conditions estimated via multipole expansion. We find that the oft-used single-center spherical multipole expansion is only appropriate for isotropic mesh domains such as spheres and cubes. In this work, we introduce a method suitable for high aspect ratio meshes whereby the charge density is partitioned into atomic domains and multipoles are computed for each domain. While this approach is moderately more expensive than a single-center expansion, it is numerically stable and still a small fraction of the overall cost of a DFT calculation. The net result is that when high aspect ratio systems are being studied, form-fitted meshes can now be used in lieu of cubic meshes to gain computational speedup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonsynonymous amino acid changes in the α-chain of complement component 5 influence longitudinal susceptibility to Plasmodium falciparum infections and severe malarial anemia in kenyan children

Background: Severe malarial anemia (SMA; Hb < 5.0 g/dl) is a leading cause of childhood morbidity and mortality in holoendemic Plasmodium falciparum transmission regions such as western Kenya. Methods: We investigated the relationship between two novel complement component 5 (C5) missense mutations [rs17216529:C>T, p(Val145Ile) and rs17610:C>T, p(Ser1310Asn)] and longitudinal outcomes of malaria in a cohort of Kenyan children (under 60 mos, n = 1,546). Molecular modeling was used to investigate the impact of the amino acid transitions on the C5 protein structure. Results: Prediction of the wild-type and mutant C5 protein structures did not reveal major changes to the overall structure. However, based on the position of the variants, subtle differences could impact on the stability of C5b. The influence of the C5 genotypes/haplotypes on the number of malaria and SMA episodes over 36 months was determined by Poisson regression modeling. Genotypic analyses revealed that inheritance of the homozygous mutant (TT) for rs17216529:C>T enhanced the risk for both malaria (incidence rate ratio, IRR = 1.144, 95%CI: 1.059–1.236, p = 0.001) and SMA (IRR = 1.627, 95%CI: 1.201–2.204, p = 0.002). In the haplotypic model, carriers of TC had increased risk of malaria (IRR = 1.068, 95%CI: 1.017–1.122, p = 0.009), while carriers of both wild-type alleles (CC) were protected against SMA (IRR = 0.679, 95%CI: 0.542–0.850, p = 0.001). Conclusion: Collectively, these findings show that the selected C5 missense mutations influence the longitudinal risk of malaria and SMA in immune-naïve children exposed to holoendemic P. falciparum transmission through a mechanism that remains to be defined.

60 APPLIED LIFE SCIENCES↗

Role of the doubly stochastic Neyman type-A and Thomas counting distributions in photon detection

The sums of Meyman type-A and Thomas random variables are shown to retain their form under the constant multiplication parameter constraint. The conditions under which the two random variables converge in distribution to the fixed multiplicative Poisson, and to the Gaussian, are presented. It is shown that the latter result is important, in that it provides a solution to likelihood-ratio detection, estimation and discrimination problems in the presence of many kinds of signal and noise. Among the explicit applications presented are: (1) the photon-counter scintillation detection of nuclear particles when particle flux is low, (2) the photon-counting detection of weak optical signals in the presence of ionizing radiation, and (3) the design of a star-scanner spacecraft guidance system adequate for hostile space environments.

Teich, M. C.↗

Using x ray images to detect substructure in a sample of 40 Abell clusters

Using a method for constraining the dynamical state of a galaxy cluster by examining the moments of its x-ray surface brightness distribution, we determine the statistics of cluster substructure for a sample of 40 Abell clusters. Using x-ray observations from the Einstein Observatory Imaging Proportional Counter (IPC), we measure the first moment M1(r), the ellipsoidal orientation angle theta2(r), and the axial ratio eta(r) at several different radii in the cluster. We determine the effects of systematics such as x-ray point source emission, telescope vignetting, Poisson noise, and characteristics of the IPC by measuring the same parameters on an ensemble of simulated cluster images. Due to the small band-pass of the IPC, the ICM emissivity is nearly independent of temperature so the intensity at each point in the IPC images is simply proportional to the emission measure calculated along the line of sight through the cluster (e.g. Fabricant et al. 1980). Therefore, barring a change superposition of two x-ray emitting clusters, a significant variation in the image centroid M1(r) as a function of radius indicates that the center of mass of the intra-cluster medium (ICM) varies with radius. We argue that such a configuration (essentially an m = 1 component in the ICM density distribution) is a non-equilibrium component; it results from an off-center subclump or a recent merger in the ICM.

Mohr, J. J.↗

Beam energy dependence of net- Λ fluctuations measured by the STAR experiment at the BNL Relativistic Heavy Ion Collider

The measurements of particle multiplicity distributions have generated considerable interest in understanding the fluctuations of conserved quantum numbers in the quantum chromodynamics (QCD) hadronization regime, in particular near a possible critical point and near the chemical freeze-out. Net-protons and net-kaons have been used as proxies for the net-baryon number and net-strangeness, respectively. We report the measurement of efficiency- and centrality-bin width-corrected cumulant ratios (C 2 /C 1 , C 3 /C 2 ) of net- Λ distributions, in the context of both strangeness and baryon number conservation, as a function of collision energy, centrality, and rapidity. The results are for Au + Au collisions at five beam energies ( √s NN = 19.6 , 27, 39, 62.4, and 200 GeV) recorded with the Solenoidal Tracker at RHIC (STAR). We compare our results to the Poisson and negative binomial (NBD) expectations, as well as to ultrarelativistic quantum molecular dynamics (UrQMD) and hadron resonance gas (HRG) model predictions. Both NBD and Poisson baselines agree with data within the statistical and systematic uncertainties. UrQMD describes the measured net- Λ C 1 and C 3 at 200 GeV reasonably well but deviates from C 2 , and the deviation increases as a function of collision energy. The ratios of the measured cumulants show no features of critical fluctuations. The chemical freeze-out temperatures extracted from a recent HRG calculation, which was successfully used to describe the net-proton, net-kaon, and net-charge data, indicate Λ freeze-out conditions similar to those of kaons. However, large deviations are found when comparing with temperatures obtained from net-proton fluctuations. The net- Λ cumulants show a weak but finite dependence on the rapidity coverage in the acceptance of the detector, which can be attributed to quantum number conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Arsenic in public water supplies and cardiovascular mortality in Spain

Background: High-chronic arsenic exposure in drinking water is associated with increased cardiovascular disease risk. At low-chronic levels, as those present in Spain, evidence is scarce. In this ecological study, we evaluated the association of municipal drinking water arsenic concentrations during the period 1998-2002 with cardiovascular mortality in the population of Spain. Methods: Arsenic concentrations in drinking water were available for 1721 municipalities, covering 24.8 million people. Standardized mortality ratios (SMRs) for cardiovascular (361,750 deaths), coronary (113,000 deaths), and cerebrovascular (103,590 deaths) disease were analyzed for the period 1999-2003. Two-level hierarchical Poisson models were used to evaluate the association of municipal drinking water arsenic concentrations with mortality adjusting for social determinants, cardiovascular risk factors, diet, and water characteristics at municipal or provincial level in 651 municipalities (200,376 cardiovascular deaths) with complete covariate information. Results: Mean municipal drinking water arsenic concentrations ranged from <1 to 118 {mu}g/L. Compared to the overall Spanish population, sex- and age-adjusted mortality rates for cardiovascular (SMR 1.10), coronary (SMR 1.18), and cerebrovascular (SMR 1.04) disease were increased in municipalities with arsenic concentrations in drinking water >10 {mu}g/L. Compared to municipalities with arsenic concentrations <1 {mu}g/L, fully adjusted cardiovascular mortality rates were increased by 2.2% (-0.9% to 5.5%) and 2.6% (-2.0% to 7.5%) in municipalities with arsenic concentrations between 1-10 and>10 {mu}g/L, respectively (P-value for trend 0.032). The corresponding figures were 5.2% (0.8% to 9.8%) and 1.5% (-4.5% to 7.9%) for coronary heart disease mortality, and 0.3% (-4.1% to 4.9%) and 1.7% (-4.9% to 8.8%) for cerebrovascular disease mortality. Conclusions: In this ecological study, elevated low-to-moderate arsenic concentrations in drinking water were associated with increased cardiovascular mortality at the municipal level. Prospective cohort studies with individual measures of arsenic exposure, standardized cardiovascular outcomes, and adequate adjustment for confounders are needed to confirm these ecological findings. Our study, however, reinforces the need to implement arsenic remediation treatments in water supply systems above the World Health Organization safety standard of 10 {mu}g/L.

54 ENVIRONMENTAL SCIENCES↗

Electron-ion plasma dynamics in the presence of highly charged dust-clusters

Electron-ion plasma expansion is studied in the presence of positively (negatively) highly charged uniformly distributed dust particles, considered as impurities. For that purpose, a multi-fluid model is used, where the charged impurities characteristics are included in Poisson's equation. We found that ion acceleration is enhanced by the presence of positively charged dust. The latter leads to spiky structures in the ion front which have a higher amplitude as the charge increases. The charged impurities have a significant effect when the combination of their charge and density is greater than a critical value which depends on ion to electron temperature ratio.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Cohort Dose-Volume Response Analysis of Parotid Gland Function After Radiotherapy: Intensity-Modulated Versus Conventional Radiotherapy

Purpose: To compare parotid gland dose-volume response relationships in a large cohort of patients treated with intensity-modulated (IMRT) and conventional radiotherapy (CRT). Methods and materials: A total of 221 patients (64 treated with IMRT, 157 with CRT) with various head-and-neck malignancies were prospectively evaluated. The distribution of tumor subsites in both groups was unbalanced. Stimulated parotid flow rates were measured before and 6 weeks, 6 months, and 1 year after radiotherapy. Parotid gland dose-volume histograms were derived from computed tomography-based treatment planning. The normal tissue complication probability (NTCP) model proposed by Lyman was fit to the data. A complication was defined as stimulated parotid flow ratio <25% of the pretreatment flow rate. The relative risk of complications was determined for IMRT vs. CRT and adjusted for the mean parotid gland dose using Poisson regression modeling. Results: One year after radiotherapy, NTCP curves for IMRT and CRT were comparable with a TD{sub 50} (uniform dose leading to a 50% complication probability) of 38 and 40 Gy, respectively. Until 6 months after RT, corrected for mean dose, different complication probabilities existed for IMRT vs. CRT. The relative risk of a complication for IMRT vs. CRT after 6 weeks was 1.42 (95% CI 1.21-1.67), after 6 months 1.41 (95% CI; 1.12-1.77), and at 1 year 1.21 (95% CI 0.87-1.68), after correcting for mean dose. Conclusions: One year after radiotherapy, no difference existed in the mean dose-based NTCP curves for IMRT and CRT. Early after radiotherapy (up to 6 months) mean dose based (Lyman) models failed to fully describe the effects of radiotherapy on the parotid glands.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated iterative calculation of transonic nacelle flowfields

A method is presented for the calculation of inviscid, supercritical flowfields about axisymmetric inlet cowls. A finite-difference calculation is performed in a simple, rectangular domain obtained from the nacelle geometry by a nearly-conformal mapping procedure. Type-dependent finite-differences are constructed using a coordinate-independent, 'rotated' differencing scheme. Methods of accelerating convergence of the iterative solution are demonstrated including a hybrid fast-Poisson-solver/relaxation scheme and an extrapolated relaxation procedure. Calculated pressure distributions are compared with experimental data for a variety of Mach numbers and mass-flow ratios, and show generally good agreement.

Caughey, D. A.↗

Numerical generation of two-dimensional grids by the use of Poisson equations with grid control at boundaries

A method for generating boundary-fitted, curvilinear, two dimensional grids by the use of the Poisson equations is presented. Grids of C-type and O-type were made about airfoils and other shapes, with circular, rectangular, cascade-type, and other outer boundary shapes. Both viscous and inviscid spacings were used. In all cases, two important types of grid control can be exercised at both inner and outer boundaries. First is arbitrary control of the distances between the boundaries and the adjacent lines of the same coordinate family, i.e., stand-off distances. Second is arbitrary control of the angles with which lines of the opposite coordinate family intersect the boundaries. Thus, both grid cell size (or aspect ratio) and grid cell skewness are controlled at boundaries. Reasonable cell size and shape are ensured even in cases wherein extreme boundary shapes would tend to cause skewness or poorly controlled grid spacing. An inherent feature of the Poisson equations is that lines in the interior of the grid smoothly connect the boundary points (the grid mapping functions are second order differentiable).

Sorenson, R. L.↗

WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT

Purpose: To combine orthogonal kilo-voltage (kV) and Mega-voltage (MV) projection data for short scan cone-beam CT to reduce imaging time on current radiation treatment systems, using a calibration-free gain correction method. Methods: Combining two orthogonal projection data sets for kV and MV imaging hardware can reduce the scan angle to as small as 110° (90°+fan) such that the total scan time is ∼18 seconds, or within a breath hold. To obtain an accurate reconstruction, the MV projection data is first linearly corrected using linear regression using the redundant data from the start and end of the sinogram, and then the combined data is reconstructed using the FDK method. To correct for the different changes of attenuation coefficients in kV/MV between soft tissue and bone, the forward projection of the segmented bone and soft tissue from the first reconstruction in the redundant region are added to the linear regression model. The MV data is corrected again using the additional information from the segmented image, and combined with kV for a second FDK reconstruction. We simulated polychromatic 120 kVp (conventional a-Si EPID with CsI) and 2.5 MVp (prototype high-DQE MV detector) projection data with Poisson noise using the XCAT phantom. The gain correction and combined kV/MV short scan reconstructions were tested with head and thorax cases, and simple contrast-to-noise ratio measurements were made in a low-contrast pattern in the head. Results: The FDK reconstruction using the proposed gain correction method can effectively reduce artifacts caused by the differences of attenuation coefficients in the kV/MV data. The CNRs of the short scans for kV, MV, and kV/MV are 5.0, 2.6 and 3.4 respectively. The proposed gain correction method also works with truncated projections. Conclusion: A novel gain correction and reconstruction method was developed to generate short scan CBCT from orthogonal kV/MV projections. This work is supported by NIH Grant 5R01CA138426-05.

60 APPLIED LIFE SCIENCES↗

An X-ray method for detecting substructure in galaxy clusters - Application to Perseus, A2256, Centaurus, Coma, and Sersic 40/6

We use the moments of the X-ray surface brightness distribution to constrain the dynamical state of a galaxy cluster. Using X-ray observations from the Einstein Observatory IPC, we measure the first moment FM, the ellipsoidal orientation angle, and the axial ratio at a sequence of radii in the cluster. We argue that a significant variation in the image centroid FM as a function of radius is evidence for a nonequilibrium feature in the intracluster medium (ICM) density distribution. In simple terms, centroid shifts indicate that the center of mass of the ICM varies with radius. This variation is a tracer of continuing dynamical evolution. For each cluster, we evaluate the significance of variations in the centroid of the IPC image by computing the same statistics on an ensemble of simulated cluster images. In producing these simulated images we include X-ray point source emission, telescope vignetting, Poisson noise, and characteristics of the IPC. Application of this new method to five Abell clusters reveals that the core of each one has significant substructure. In addition, we find significant variations in the orientation angle and the axial ratio for several of the clusters.

Mohr, Joseph J.↗