Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

SU-G-206-17: RadShield: Semi-Automated Shielding Design for CT Using NCRP 147 and Isodose Curves

Purpose: Computed tomography (CT) exam rooms are shielded more quickly and accurately compared to manual calculations using RadShield, a semi-automated diagnostic shielding software package. Last year, we presented RadShield’s approach to shielding radiographic and fluoroscopic rooms calculating air kerma rate and barrier thickness at many points on the floor plan and reporting the maximum values for each barrier. RadShield has now been expanded to include CT shielding design using not only NCRP 147 methodology but also by overlaying vendor provided isodose curves onto the floor plan. Methods: The floor plan image is imported onto the RadShield workspace to serve as a template for drawing barriers, occupied regions and CT locations. SubGUIs are used to set design goals, occupancy factors, workload, and overlay isodose curve files. CTDI and DLP methods are solved following NCRP 147. RadShield’s isodose curve method employs radial scanning to extract data point sets to fit kerma to a generalized power law equation of the form K(r) = ar^b. RadShield’s semiautomated shielding recommendations were compared against a board certified medical physicist’s design using dose length product (DLP) and isodose curves. Results: The percentage error found between the physicist’s manual calculation and RadShield’s semi-automated calculation of lead barrier thickness was 3.42% and 21.17% for the DLP and isodose curve methods, respectively. The medical physicist’s selection of calculation points for recommending lead thickness was roughly the same as those found by RadShield for the DLP method but differed greatly using the isodose method. Conclusion: RadShield improves accuracy in calculating air-kerma rate and barrier thickness over manual calculations using isodose curves. Isodose curves were less intuitive and more prone to error for the physicist than inverse square methods. RadShield can now perform shielding design calculations for general scattering bodies for which isodose curves are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗

M4SF-19LL010302042: Pu Incorporation into Reduced Iron Oxide Phases

The research is focused on actinide and radionuclide sequestration in steel corrosion products. The effort described herein was focused on identifying synthesis methods for reduced Fe-oxide phases and performing Pu sorption and coprecipitation experiments to determine the fractionation of Pu into and onto these phases. Specifically, we are: Quantifying the rate of Pu incorporation to magnetite and green rust, and Characterizing the nature and morphology of sorbed and coprecipitated Pu on these phases.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of Particle and Heat Losses from a High-Temperature Particle Receiver

High-temperature particle receivers are being pursued to enable next-generation concentrating solar thermal power (CSP) systems that can achieve higher temperatures (> 700 °C) to enable more efficient power cycles, lower overall system costs, and emerging CSP-based process-heat applications. The objective of this work was to develop characterization methods to quantify the particle and heat losses from the open aperture of the particle receiver. Novel camera- based imaging methods were developed and applied to both laboratory-scale and larger 1 MW t on-sun tests at the National Solar Thermal Test Facility in Albuquerque, New Mexico. Validation of the imaging methods was performed using gravimetric and calorimetric methods. In addition, conventional particle-sampling methods using volumetric particle-air samplers were applied to the on-sun tests to compare particle emission rates with regulatory standards for worker safety and pollution. Novel particle sampling methods using 3-D printed tipping buckets and tethered balloons were also developed and applied to the on-sun particle-receiver tests. Finally, models were developed to simulate the impact of particle size and wind on particle emissions and concentrations as a function of location. Results showed that particle emissions and concentrations were well below regulatory standards for worker safety and pollution. In addition, estimated particle temperatures and advective heat losses from the camera-based imaging methods correlated well with measured values during the on-sun tests.

14 SOLAR ENERGY↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Investigation of residual stress distribution in wire-arc directed energy deposited refractory molybdenum alloy utilizing numerical thermo-mechanical analysis and neutron diffraction method

Directed energy deposition (DED), a metal additive manufacturing (AM) technique, offers higher deposition rates and energy efficiency, making it suitable for fabricating components from refractory molybdenum alloys, such as molybdenum-titanium-zirconium (TZM). However, large thermal gradients and non-equilibrium thermal cycles in DED could generate high residual stress in the component, potentially deteriorating quality and performance. Thus, this study aims to investigate residual stress generation and its distribution in wire-arc DED of TZM thin-wall, utilizing thermo-mechanical analysis and high-fidelity neutron diffraction (ND) method. Two interpass temperatures (50°C and 200°C) have been considered to investigate their impact on residual stress formation. During experiments, in-situ thermal data has been recorded using thermocouples, which have been utilized for calibrating the thermal model. Thermocouple data shows a good agreement with the simulation results, having a difference of less than 10 %. Post-deposition part deformation has been observed, which is measured using a coordinate measuring machine, showing maximum values of 0.93 mm and 0.78 mm for interpass temperatures of 50°C and 200°C, respectively. Numerical predictions of distortion deviated by less than 15% from the experimental results. ND measurement and simulation results indicate that residual stress magnitude and evolution vary across the TZM deposits, revealing microstructural anisotropy in both conditions. Notably, lower interpass temperatures resulted in higher residual stresses, confirmed by experimental and simulation data. Further, this study demonstrated that an integrated experimental and thermo-mechanical analysis can potentially reveal the temperature history, part deformation, and residual stress formation in wire-arc DED TZM alloy.

36 MATERIALS SCIENCE↗

Kinetic phase evolution of spinel cobalt oxide during lithiation

Spinel cobalt oxide has been proposed to undergo a multiple-step reaction during the electrochemical lithiation process. Understanding the kinetics of the lithiation process in this compound is crucial to optimize its performance and cyclability. In this work, we have utilized a low-angle annular dark-field scanning transmission electron microscopy method to visualize the dynamic reaction process in real time and study the reaction kinetics at different rates. We show that the particles undergo a two-step reaction at the single-particle level, which includes an initial intercalation reaction followed by a conversion reaction. At low rates, the conversion reaction starts after the intercalation reaction has fully finished, consistent with the prediction of density functional theoretical calculations. At high rates, the intercalation reaction is overwhelmed by the subsequently nucleated conversion reaction, and the reaction speeds of both the intercalation and conversion reactions are increased. Phase-field simulations show the crucial role of surface diffusion rates of lithium ions in controlling this process. Furthermore, this work provides microscopic insights into the reaction dynamics in non-equilibrium conditions and highlights the effect of lithium diffusion rates on the overall reaction homogeneity as well as the performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Direct Randomized Benchmarking for Multiqubit Devices

Benchmarking methods that can be adapted to multiqubit systems are essential for assessing the overall or “holistic” performance of nascent quantum processors. The current industry standard is Clifford randomized benchmarking (RB), which measures a single error rate that quantifies overall performance. But, scaling Clifford RB to many qubits is surprisingly hard. It has only been performed on one, two, and three qubits as of this writing. This reflects a fundamental inefficiency in Clifford RB: the n-qubit Clifford gates at its core have to be compiled into large circuits over the one- and two-qubit gates native to a device. As n grows, the quality of these Clifford gates quickly degrades, making Clifford RB impractical at relatively low n. In this Letter, we propose a direct RB protocol that mostly avoids compiling. Instead, it uses random circuits over the native gates in a device, which are seeded by an initial layer of Clifford-like randomization. We demonstrate this protocol experimentally on two to five qubits using the publicly available ibmqx5. We believe this to be the greatest number of qubits holistically benchmarked, and this was achieved on a freely available device without any special tuning up. Our protocol retains the simplicity and convenient properties of Clifford RB: it estimates an error rate from an exponential decay. But, it can be extended to processors with more qubits—we present simulations on 10+ qubits—and it reports a more directly informative and flexible error rate than the one reported by Clifford RB. Here, we show how to use this flexibility to measure separate error rates for distinct sets of gates, and we use this method to estimate the average error rate of a set of cnot gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DISCRETE ELEMENT MODELING OF BLADE–STRIKE FREQUENCY AND SURVIVAL OF FISH PASSING THROUGH HYDROKINETIC TURBINES

Evaluating the consequences from blade-strike of fish on marine hydrokinetic (MHK) turbine blades is essential for incorporating environmental objectives into the integral optimization of machine performance. For instance, experience with conventional hydroelectric turbines has shown that innovative shaping of the blade and other machine components can lead to improved designs that generate more power without increased impacts to fish and other aquatic life. In this work, we used unsteady computational fluid dynamics (CFD) simulations of turbine flow and discrete element modeling (DEM) of particle motion to estimate the frequency and severity of collisions between a horizontal axis MHK tidal energy device and drifting aquatic organisms or debris. Two metrics are determined with the method: the strike frequency and survival rate estimate. To illustrate the procedure step-by-step, an exemplary case of a simple runner model was run and compared against a probabilistic model widely used for strike frequency evaluation. The results for the exemplary case showed a strong correlation between the two approaches. In the application case of the MHK turbine flow, turbulent flow was modeled using detached eddy simulation (DES) in conjunction with a full moving rotor at full scale. The CFD simulated power and thrust were satisfactorily comparable to experimental results conducted in a water tunnel on a reduced scaled (1:8.7) version of the turbine design. A cloud of DEM particles was injected into the domain to simulate fish or debris that were entrained into the turbine flow. The strike frequency was the ratio of the count of colliding particles to the crossing sample size. The fish length and approaching velocity were test conditions in the simulations of the MHK turbine. Comparisons showed that DEM-based frequencies tend to be greater than previous results from Lagrangian particles and probabilistic models, mostly because the DEM scheme accounts for both the geometric aspects of the passage event ---which the probabilistic method does--- as well as the fluid-particle interactions ---which the Lagrangian particle method does. The DEM-based survival rates were comparable to laboratory results for small fish but not for mid-size fish because of the considerably different turbine diameters. The modeling framework can be used for applications that aim at evaluating the biological performance of MHK turbine units during the design phase and to provide information to regulatory agencies needed for the environmental permitting process.

blade strike↗

Comprehensive Lateral Neck Dissection in Papillary Thyroid Carcinoma may Reduce Lateral Neck Recurrence Rates

Objective: To Identify predictors of recurrent disease following lateral neck dissection (LND) for papillary thyroid carcinoma (PTC). Methods: A retrospective review of patients who underwent first-time LND for PTC at our institution (2000–2015) was performed. Medical records were examined for biopsy or pathologically proven lateral neck recurrence. Differences between the groups with and without recurrence were compared. All LNDs were then classified in to two groups: “comprehensive” (CND), involving levels IIa-Vb at minimum, or “selective”, labelling less extensive dissection (SND). Results: Four hundred nine patients underwent 467 LNDs. Surveillance data were available for 317 patients who underwent 362 LNDs (mean age 45 ± 16; range 18–88). The median follow-up was 64 ± 48 months (range 3–197). Recurrence was detected in 71 lateral necks (20%). The total number of lymph nodes was greater in the group without recurrence compared to those with recurrence (23 vs. 19, p = 0.02). Among patient demographics, radioactive iodine treatment, primary tumor characteristics and characteristics of nodal metastases, only an older patient age (mean 50 vs. 43 years) was associated with lateral neck recurrence (p < .01). CND was performed in 102 lateral necks and SND in 143 necks. There were 12 recurrences recorded in the CND group (12%) vs. 31 in the SND group (22%, p = .04). The majority of recurrences (70%) involved levels included in the original dissection. Conclusions: Younger patients, more extensive dissection and a higher total number of lymph nodes removed are associated with a lower incidence of lateral neck recurrence after LND for papillary thyroid carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SPECTRAL CLASSIFICATION OF GALAXIES AT 0.5 {<=} z {<=} 1 IN THE CDFS: THE ARTIFICIAL NEURAL NETWORK APPROACH

The aim of this work is to combine spectral energy distribution (SED) fitting with artificial neural network techniques to assign spectral characteristics to a sample of galaxies at 0.5 < z < 1. The sample is selected from the spectroscopic campaign of the ESO/GOODS-South field, with 142 sources having photometric data from the GOODS-MUSIC catalog covering bands between {approx}0.4 and 24 {mu}m in 10-13 filters. We use the CIGALE code to fit photometric data to Maraston's synthesis spectra to derive mass, specific star formation rate, and age, as well as the best SED of the galaxies. We use the spectral models presented by Kinney et al. as targets in the wavelength interval {approx}1200-7500 A. Then a series of neural networks are trained, with average performance {approx}90%, to classify the best SED in a supervised manner. We consider the effects of the prominent features of the best SED on the performance of the trained networks and also test networks on the galaxy spectra of Coleman et al., which have a lower resolution than the target models. In this way, we conclude that the trained networks take into account all the features of the spectra simultaneously. Using the method, 105 out of 142 galaxies of the sample are classified with high significance. The locus of the classified galaxies in the three graphs of the physical parameters of mass, age, and specific star formation rate appears consistent with the morphological characteristics of the galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Online Adaptive Hyperthermia Treatment Planning: Correlation Between Measured and Simulated Specific Absorption Rate Changes Caused by Phase Steering in Patients

Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements were performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

Fabrication and characterization of flower-like BiOI/Pt heterostructure with enhanced photocatalytic activity under visible light irradiation

Flower-like Pt/BiOI composite nanosheets were successfully constructed by a photo-reduction method. The nanosized Pt/BiOI composites exhibited considerably enhanced photocatalytic performance for rhodamine B (RhB) and phenol degradation under visible-light irradiation (λ > 420 nm) when compared with that of pure BiOI. Various characterization methods were used to evaluate the mechanism of enhanced photocatalytic activity. The highest photocatalytic activity was achieved when the composites had a Pt content of 3 wt%, which is 17.8 times and 9 times higher than that of pure BiOI, respectively. The enhanced catalytic efficiency was attributed to the low rate of recombination of electron-hole pairs. Superoxide radicals and holes were found to be crucial species during the photocatalytic degradation. A possible mechanism of photocatalysis was also proposed based on the results of experiments. - Highlights: • Flower-like BiOI/Pt heterostructure are synthesized by a two step method. • The photocatalytic performance of as prepared samples are carried out under visible light irradiation. • The mechanism for the catalyst activity is discussed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiment and Results on Plasma Etching of SRF cavities

The inner surfaces of SRF cavities are currently chemically treated (etched or electropolished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically etched and RF tested to establish a baseline performance. This cavity is plasma etched and RF tested afterwards. The effect of plasma etching on the RF performance of this cavity will be presented and discussed.

43 PARTICLE ACCELERATORS↗

SU-F-T-584: Investigating Correction Methods for Ion Recombination Effects in OCTAVIUS 1000 SRS Measurements

Purpose: PTW’s Octavius 1000 SRS array performs IMRT QA measurements with liquid filled ionization chambers (LICs). Collection efficiencies of LICs have been shown to change during IMRT delivery as a function of LINAC pulse frequency and pulse dose, which affects QA results. In this study, two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: For the first correction, Matlab software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction, MU/min in daily 1000 SRS calibration was chosen to match average MU/min of the VMAT plan. Usefulness of derived corrections were evaluated using 6MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam equipped with an HD- MLC. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: After complex Matlab corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex Matlab corrections. Conclusion: Ion recombination effects can potentially be clinically significant for OCTAVIUS 1000 SRS measurements, especially for higher pulse dose unflattened beams when using tighter gamma tolerances. Matching daily 1000 SRS calibration MU/min to average planned MU/min is a simple correction that greatly reduces ion recombination effects, improving measurements accuracy and gamma pass rates. This work was supported by PTW.

60 APPLIED LIFE SCIENCES↗

Hepatic Toxicity After Radioembolization of the Liver Using {sup 90}Y-Microspheres: Sequential Lobar Versus Whole Liver Approach

Purpose: {sup 90}Y-radioembolization (RE) is a promising technique for delivering high doses of radiation to liver tumors but may result in compromise of liver function. To gain further perspective, we evaluated the toxicity rates of sequential lobar versus 'whole liver' {sup 90}Y-radioembolization. Methods: Thirty-four patients with liver malignancy in noncirrhotic livers were included; {sup 90}Y-radioembolization was performed as either whole liver or sequential lobar treatment in 17 patients each. Standard clinical and liver specific laboratory parameters as well as MR imaging before treatment and at follow-up (6 and 12 weeks) after radioembolization were evaluated for toxicity using the Common Terminology Criteria for Adverse Events (CTCAE). Volumetry of the liver, tumor, and spleen and measurement of portal vein diameter also were performed. Results: Three months after whole liver RE, 14 liver-related grade 3/4 events were recorded versus 2 events after sequential lobar treatment (P < 0.05). Three patients treated with whole liver RE suffered from radioembolization-induced liver disease (REILD). Pathological increases in bilirubin at 3 months were observed for the whole liver group only (52.3 vs. 18.7 {mu}mol/l, P = 0.012). Total liver volume did not change significantly in either group, but shrinkage of the initially treated hepatic lobe with compensatory hypertrophy of the subsequently treated lobe was observed in the sequential lobar group (P < 0.05). Portal vein diameter increased significantly in whole liver-treated patients only (+17% vs. +6.6%, P = 0.043). Conclusions: Noncirrhotic patients undergoing sequential lobar radioembolization had less hepatic toxicity compared to whole liver embolization. The sequential approach should be the preferred strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cloud based tool for analysis of chemical kinetic mechanisms

The size and complexity of chemical kinetic models used to simulate combustion of hydrocarbon fuels continue to increase with our improved understanding of the underlying physical mechanisms, along with the improved ability to utilize such models as the result of increased computational power and efficiency. As mechanisms grow beyond thousands of species and tens of thousands of reactions, it becomes increasingly difficult to manually check for errors and physical inconsistencies. In this work, we present several automated methods to check for such issues in the specification of chemical reaction models. First, we demonstrate how discontinuities in thermodynamic data can cause simulation difficulties manifested as long wall-clock times and convergence failures. To correct this type of problem, we describe an automated method for refitting thermodynamic parameters. We also outline several methods to check the timescales of reaction rate coefficients to ensure physical consistency. All the methods are made available through a web-based tool (https://combustiontools.llnl.gov) intended to aid mechanism developers and users to improve the accuracy and performance of fuel models used by the combustion community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗