Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Analysis of Nuclear Fuel Cycle Data

Electricity generated using nuclear power accounted for 18.9% of all electricity consumed in the United States in 2021, putting it in third place behind natural gas (38%) and coal (22%) power plants. Nuclear power plants boast a significantly higher uptime or capacity factor—90% and above—compared to 49.1% for coal fired power plants and 56.6% for natural gas power plants. Renewable energy sources, such as solar photovoltaic (PV) and wind electricity, have lower capacity factors: 24.9% and 36.3%, respectively. In addition, nuclear power is cleaner than both coal and natural gas fired power plants. With the passing of the 2022 Inflation Reduction Act, significant tax credits will be claimed by producers of hydrogen with well-to-gate greenhouse gas (GHG) emissions below 0.45 kg CO 2e /kg H 2 . This has sparked interest in using clean sources of electricity, including nuclear power, to generate H 2 via water electrolysis. As uranium is a primary fuel for modern nuclear power plants, the upstream emissions from nuclear fuel production greatly impact the GHG emissions related to all nuclear power end use. Therefore, it is important to accurately determine the upstream emissions associated with the nuclear fuel cycle of nuclear power production in the United States. In this analysis, the nuclear fuel cycle was separated into distinct steps to allow better understanding of the chemical and energy inputs at each step of the fuel cycle. This also provides details of the GHG emissions at each step in the nuclear fuel cycle. The transportation distance for each step of the fuel cycle was updated to account for the locations of uranium processing facilities along the supply chain of the current U.S. nuclear power plants. Finally, all the updated values were incorporated into Argonne National Laboratory’s Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

EverGREEN 2045: An Energy Mix to Decarbonize Washington State

Washington State’s future resource mix is likely to be comprised of intermittent renewables and carbon-free generation including hydropower by 2045. Generation will likely be comprised of wind, solar photovoltaic (PV), batteries, pumped storage hydropower (PSH), existing nuclear power plants, and potentially enhanced geothermal systems and advanced nuclear reactor technologies. To assess the cost and stability of the future resource mix, we partner with X-energy (advanced reactor design) and AltaRock Energy (enhanced geothermal system) for proprietary cost data. After estimating the costs of these two new technologies, we design plausible future resource mix scenarios to meet Washington State’s Clean Energy Transformation Act which transitions the state to carbon-free generation by 2045. We assess the cost and stability of the future resource mix with power system analysis tools, finding revenues are sufficient to cover variable operating and maintenance costs for most technologies providing power in 2030 and 2045, but capacity payments or power purchase agreements will likely be necessary for flexible resources, including enhanced geothermal systems and advanced nuclear reactors, to participate in the future resource mix.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2024 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis.

14 SOLAR ENERGY↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING↗

Networked Microgrids for Improved Resilient Operation: A Case Study in Adjuntas Puerto Rico

This paper presents a case study of a network microgrid orchestrator designed to allow coordinated operation of microgrids. Through Control Hardware in the Loop (CHIL), the proposed microgrid orchestrator was validated using, as case study two community-owned microgrids in Adjuntas, Puerto Rico. These two microgrids in Adjuntas were designed to provide affordable and reliable access to electricity to 14 businesses located in the town square. In its current design, these two microgrids operate independently from each other. This paper studies how networking them would increase their resiliency metrics while operating as an island. A distributed optimization is implemented in the microgrid orchestrator due to its superior scalability compared to centralized approach as well as to maintain data privacy. Two operational modes are considered in this study to showcase the advantages of networking microgrids: a) normal island, and b) degraded island. CHIL simulations are performed to validate the proposed microgrid orchestrator. CHIL results show meaningful resiliency improvements obtained by networking microgrids during contingencies such as loss of PV generation.

Ferrari Maglia, Max↗

Summary of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Northwest – Horn Rapids Solar and Storage: A Techno-economic Assessment

In 2017, as part of the second round of funding from the Washington State Clean Energy Fund, the Washington State Department of Commerce granted up to $\$3$ million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/4 MWh (nameplate capacity) lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. This report documents the techno-economic assessment of the integrated system, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, case studies, and analysis results.

14 SOLAR ENERGY↗

Annual Solar Irradiance Anomaly Features Over the USA During 1998-2017 Using NSRDB V3

Annual solar irradiance anomalies (or departures from the long-term mean annual value) have a direct impact on various phases of solar energy projects, from prefeasibility studies to technical deployment decisions. Anomalies can happen because of normal climate variability or exceptional weather patterns. This study investigates such anomalies for both global horizontal irradiance (GHI) and direct normal irradiance (DNI) using Version 3 of the National Solar Radiation Database (NSRDB V3) and surface irradiance measurements at eight U.S. locations. At each site, the annual anomaly is analyzed here by evaluating the irradiance deviation from the long-term average for each specific year from 1998–2017. A positive/negative anomaly indicates that the solar resource was higher/lower than the long-term average during that specific year. The results show that in most cases the anomaly is within ±5% for GHI and ±10% for DNI using either ground-based irradiance measurements or modeled data from the NSRDB.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Annual Solar Irradiance Anomaly Features Over the USA During 1998-2017 Using NSRDB V3: Preprint

Annual solar irradiance anomalies (or departures from the long-term mean annual value) have a direct effect on various phases of solar energy projects, from prefeasibility to deploy-ment. Anomalies can happen because of normal climate varia-bility or exceptional weather patterns. This study investigates such anomalies for both global horizontal irradiance (GHI) and direct normal irradiance (DNI) using Version 3 of the National Solar Radiation Database (NSRDB V3) and surface irradiance measurements at eight U.S. locations. At each site, the annual anomaly is analyzed here by evaluating the irradi-ance deviation from the long-term average for each specific year during 1998–2017. A positive anomaly indicates that the solar resource was higher than the long-term average during that specific year, and vice versa in the case of a negative anomaly. The results show that, in most cases, the anomaly is within ±5% for GHI and ±10% for DNI, using either ground-based irradiance measurements or modeled data from the NSRDB.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Global horizontal spectral irradiance and module spectral response measurements: an open dataset for PV research

This report describes the creation process and final content of a spectral irradiance dataset for Albuquerque, New Mexico accompanied by a set of spectral response measurements for modules deployed at the same location. The spectral irradiance measurements were made using horizontally mounted spectroradiometers; therefore, they represent global horizontal irradiance. The dataset combines non-continuous spectroradiometer and weather measurements from a two-year period into a single calendar year. The data files are accompanied by extensive metadata as well as example calculations and graphs to demonstrate the potential uses of this database. The spectral response measurements were carried out by the National Renewable Energy Laboratory using 12 commercial silicon modules types that are undergoing long-term evaluation at Sandia National Laboratories in Albuquerque.

14 SOLAR ENERGY↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

On the Radiation Effects of Strontium Ions on Satellite Solar Cells in Low Earth Orbits

This study focuses on the radiation effects 19 of Sr + ions—generated from high-altitude nuclear explosions (HANE)—on satellite solar cells in low-Earth orbits (LEO). Along four selected satellite orbits, ion fluences are sampled inside the evolving Sr + distributions for days, determined from our newly developed HANE environment model. These fluences, along with the help of radiation transport codes including the MULASSIS and SRIM models, enable us to quantify the radiation damages by determining the values of total ionizing doses and the equivalent 1 MeV electron fluences for displacement damages. Comparing the dose values to existing experimental data, we conclude that HANE-generated Sr + ions have limited darkening effects to quartz solar cell coverglasses in LEO with apogees of 100s to 1000 km. In addition, with the extremely high equivalent fluences, we also conclude that these Sr+ ions may cause severe or even fatal displacement damage to exposed solar photovoltaic (PV) cells on satellites in LEO. The radiation effects of Sr + ions are much less significant for the orbits with high apogees beyond ten thousand km. We also conducted model parameter sensitivity studies on the charge exchange cross-sections, neutral atmosphere density profiles and explosion local time positions, and the above conclusions stay unchanged. The methodology developed in this study can be extended to other HANE-generated heavy ion species in the future.

14 SOLAR ENERGY↗

Overcoming Communications Outages in Inverter Downtime Analysis: Preprint

Inverters are often reported to be the highest-impact failure point in PV systems. This importance is belied by the simplistic assumptions about inverter downtime losses used in industrial energy modeling. Energy models often assume the extent of inverter-related losses is limited to 1% of annual production from scheduled inverter preventative maintenance. In reality, inverter-related production losses are much more variable, although data from large-scale surveys of fielded systems are rare. Here we present a method of detecting inverter downtime events and estimating the associated lost production using inverter- and meter-level power data. Because communications outages are of similar frequency to true production outages, the method pays particular attention to distinguishing communications outages from true production outages. The results of applying the method at fleet-scale are presented and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Viewfactor and Raytracing for AgriPV Modeling

View factor models are used in due diligence software to calculate rear irradiance for bifacial modules. An intermediate step in this calculation is the irradiance at the ground level, which can be leveraged for evaluating the Photo Active Radiation available for crops in Agrivoltaic setups. This paper presents the metrics and modifications to the model for ground irradiance study with the view factor approach, compares it to the raytracing method, and validates it with field measurements of ground irradiance. It is found that for the clearances, row-to-row setups, and tilts studied, the view factor method matches with raytracing results within 2% MBD. The comparison is performed for the nine most common agriPV configurations using high-performance computing and the NSRDB database for the whole US, with results and data made available open-source on the InSPIRE AgriPV website.

AgriPV↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗