Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Case Study: Link Logistics Industrial Solar PV

This case study describes how Link Logistics uses community solar programs and other internal procedures to increase NOI at a warehouse property through leasing roof space for solar installation.

solar, solar PV, photovoltaic, onsite solar, indus↗

Case Study: Healthcare Realty's Medical Office Solar PV

This case study describes how Healthcare Realty partnered with a renewable energy advisor to establish its solar program and make progress towards its energy and GHG emissions reduction goals; all of the projects in the pipeline will be financed through third-party ownership, via power purchase agreements or through a feed-in-tariff program.

solar, solar PV, photovoltaic, onsite solar, healt↗

LETID in Legacy and Modern PV Modules: Accelerated Testing and Field Deployment

The kinetics of light- and elevated temperature-induced degradation (LETID) in silicon solar cells depend on the precise operating excess carrier density (?n) of the device. This dependency causes differences in the way LETID manifests in modern, higher-efficiency devices compared to lower-efficiency, legacy devices that might have been deployed in the field in previous years. In this work we model how different vintages of devices are expected to behave in both accelerated laboratory testing, as well as field deployment. The differing excess carrier densities encountered in various module vintages has implications both for interpreting accelerated test data, as well as identifying, diagnosing, and potentially treating LETID in the field.

excess carrier density↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

Optical Modeling of Polysilicon: TOPCon PV

Determine how film thickness changes with different deposition methods. Analyze relationship between film thickness and optical constants. The deposition rate of intrinsic polysilicon is higher during initial deposition then begins to slow down as deposition time increases. Longer depositions of polysilicon are more crystalline in structure than shorter depositions. N-type doping of polysilicon is more crystalline in structure than p-type doping, despite similar film thicknesses.

Bruggeman effective media approximation↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems

Deep decarbonization of power system operations requires the maximal utilization of available renewable resources. At distribution-level operations, however, grid operators can face numerous challenges in integrating renewables at scale owing to the inherent intermittence of renewable energy resources. These include phenomena such as voltage fluctuations, which are typically mitigated through control actuators such as on-load tap changers (OLTC) as well as energy storage devices, such as battery energy storage systems (BESS). On the one hand, high intermittence of the available renewable portfolio may require increasingly aggressive control of actuators, thereby accelerating the probability of equipment failure. On the other hand, integrating BESS operations and having a diverse renewable generation portfolio can typically help stagger power/energy flow to mitigate the aforementioned adverse impacts. In this paper, we employ a Bayesian framework for equipment lifetime estimation to understand the impact of including tidal energy resources and BESS in distribution system operations for feeders having substantial distribution photovoltaic generation. Our results indicate that while tidal energy alone may slightly decrease equipment reliability, the adverse impact on reliability is significantly magnified by a generation portfolio consisting of tidal generation and photovoltaic generation. Here, we also study the tidal and photovoltaic hosting capacity problem with and without energy storage systems using equipment reliability as an added constraint. We conclude that energy storage increases the reliability-constrained hosting capacity of the distribution system.

14 SOLAR ENERGY↗

Mismatch losses in a PV system due to shortened strings

Numerous events may require intentional removal of one or more photovoltaic modules from a string, shortening the length of the string relative to others within the array, resulting in a string length mismatch. The impact of such a mismatch is not well understood either in measurable operational effects (voltage, current, power) or in the potential effects on long-term module health. It is impractical to solely approach this problem experimentally due to the size and complexity of arrays that may experience string length shortening. Here this work presents simulations, validated through limited field experiments on a two string array, providing a basis from which more complex arrays and scenarios may be explored. Refinement of the simulation achieves an overall error in IMPP for the nominal (S 1 ) and test strings (S 2 ) between the simulation and experimental values, through all test conditions, of +0.35 ± 1.46% and -0.36 ± 1.58% respectively. Shortening one of two strings by one module results in a power loss greater than the power contribution of the module alone (1.29 module equivalents); the impact increases through the maximum test case of a six module mismatch with a power loss equivalent to more than 11 modules. The impact of using string-end blocking diodes is presented with an emphasis at the array maximum power point and at open circuit. Implications are discussed for arrays of higher complexity.

14 SOLAR ENERGY↗