Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROCESS CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Biomedical Ti-35Nb-5Ta-7Zr Alloy Fabricated by Powder Metallurgy

Ti-35Nb-5Ta-7Zr alloy for biomedical applications with a reduced Young’s modulus of less than 10 GPa, being comparable to that of human bones, was successfully fabricated by powder metallurgy method. The microstructure, compressive and tensile behavior were studied. Results indicate that Ti-rich and Ta-rich phases co-exist in β-matrix. Ti-35Nb-5Ta-7Zr alloys yield at about 10% in compression, with increasing in the content of process control agent, the resultant compressive yield strength and Young’s modulus increase from 650 ± 46 to 1055 ± 90 MPa and from 6.3 ± 0.03 to 8.24 ± 0.04 GPa, respectively. The tensile fractography of alloy with 9.7 GPa tensile Young’s modulus, 433 MPa UTS at the 5.5% elongation consists of cleavage fracture and ductile fracture with dimples. The failure mechanism has been discussed taking the intrinsic microstructural features into consideration.

36 MATERIALS SCIENCE↗

Laser-based Adhesion Strength Measurements for Advanced Manufactured Sensor Adhesion Characterization

As part of the advanced manufacturing (AM) focus of the Nuclear Energy Enabling Technologies (NEET) Advanced Sensors and Instrumentation (ASI) Program, new in-house capabilities to fabricate and test novel active and passive in-pile sensors are being developed at the Idaho National Laboratory (INL). These advanced-manufactured sensors, such as peak temperature monitors and strain gauges, must be miniaturized and be able to provide real-time feedback, all while withstanding the coupled extremes of temperature and radiation typically observed in the environment of a nuclear test reactor. Fabricating durable and robust in-pile sensors with high fidelity requires a fundamental understanding of the optimal process parameters required in the AM technique, as well as the effect of deviations from optimal process parameters on the sensor-substrate adhesion and the ultimate robustness of the sensor. This report presents the use of a laser-based, non-contact approach for characterizing the adhesion of sensors manufactured using aerosol jet printing (AJP) that comprise of silver nanoparticle inks deposited and sintered on austenitic stainless steel (SS) 316L substrates. The effect of substrate surface roughness, surface energy, ink sintering time and sintering temperature on the printed sensor topography and the sensor-substrate adhesion has been systematically investigated. The sensor-substrate interfacial adhesion strength was determined from the critical laser pulse energy required to ablate/ detach the printed sensor from the substrate. Measurements of the sensor topography using optical profilometry revealed that post-deposition sintering at 400°C for 60 minutes resulted in a reduced sensor thickness, while plasma treating the substrate prior to printing yielded sensors with uniform thickness profiles transverse to the print direction. Sintering temperature and time were found to be the dominant parameters that affected sensor-substrate adhesion, followed by substrate surface roughness. The laser-based and locally-destructive approach for adhesion strength measurements shows promise in overcoming the challenges and limitations of current standardized peel tests and can be developed into a post-fabrication process control protocol for evaluating the durability of AM printed sensors in a high throughput fashion. Future studies will investigate the use of laser-induced spallation techniques as well as non-destructive laser ultrasonic methods for sensor-substrate adhesion characterization on sensors manufactured using AJP and other AM techniques such as plasma jet printing (PJP).

42 ENGINEERING↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

MO-PIS-Exhibit Hall-01: Tools for TG-142 Linac Imaging QA I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The therapy topic this year is solutions for TG-142 recommendations for linear accelerator imaging QA. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Automated Imaging QA for TG-142 with RIT Presentation Time: 2:45 – 3:15 PM This presentation will discuss software tools for automated imaging QA and phantom analysis for TG-142. All modalities used in radiation oncology will be discussed, including CBCT, planar kV imaging, planar MV imaging, and imaging and treatment coordinate coincidence. Vendor supplied phantoms as well as a variety of third-party phantoms will be shown, along with appropriate analyses, proper phantom setup procedures and scanning settings, and a discussion of image quality metrics. Tools for process automation will be discussed which include: RIT Cognition (machine learning for phantom image identification), RIT Cerberus (automated file system monitoring and searching), and RunQueueC (batch processing of multiple images). In addition to phantom analysis, tools for statistical tracking, trending, and reporting will be discussed. This discussion will include an introduction to statistical process control, a valuable tool in analyzing data and determining appropriate tolerances. An Introduction to TG-142 Imaging QA Using Standard Imaging Products Presentation Time: 3:15 – 3:45 PM Medical Physicists want to understand the logic behind TG-142 Imaging QA. What is often missing is a firm understanding of the connections between the EPID and OBI phantom imaging, the software “algorithms” that calculate the QA metrics, the establishment of baselines, and the analysis and interpretation of the results. The goal of our brief presentation will be to establish and solidify these connections. Our talk will be motivated by the Standard Imaging, Inc. phantom and software solutions. We will present and explain each of the image quality metrics in TG-142 in terms of the theory, mathematics, and algorithms used to implement them in the Standard Imaging PIPSpro software. In the process, we will identify the regions of phantom images that are analyzed by each algorithm. We then will discuss the process of the creation of baselines and typical ranges of acceptable values for each imaging quality metric.

07 ISOTOPE AND RADIATION SOURCES↗

TU-B-304-01: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-02: Quantitative FMEA of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

Contactless Production Testing of Silicon Solar Cells

Critical cost reductions in silicon solar cells are made by minimizing silver usage in their metal contacts. The reason why is both clear and unavoidable—silver is not only expensive, but also a potential limiting resource for scale-up (the PV industry alone used 10.3 % of the global silver supply in 2020 [1]). The result is solar cells with vanishing electrical contact area that are extremely difficult to test prior to module manufacture, when they must be sorted for quality to maximize power output and reliability of the subsequent modules. This project developed a new measurement instrument that enables the transition to solar cells with very low silver content, including cell designs with both minimal busbars and no busbars at all to electrically contact. The resulting instrument at project completion demonstrated the ability to sort cells with comparable—or better—results than existing technology. Compared to existing cell-test instruments, the new tool has minimal contacting requirements, which lowers the maintenance costs and use of consumable parts. We demonstrated innovative, yet pragmatic, solutions for reporting a comprehensive set of measurement results useful for both cell sorting (going forward in the line for module manufacture) and process control (looking backward in the line to identify cell manufacturing issues from wafer to cell-test). In addition to the traditional current-voltage characterization at cell test—short circuit current, open-circuit voltage, power, efficiency and fill factor—the new tool maintains all the advanced parameter characterization of our existing product line such as a substrate doping measurement, carrier recombination (lifetime) analysis, and surface recombination analysis.

14 SOLAR ENERGY↗

Proof-of-principle demonstration of a virtual flow meter-based transducer for gaseous helium monitoring in particle accelerator cryogenics

A transducer based on a virtual flow meter is proposed for monitoring helium distribution and consumption in cryogenic systems for particle accelerators. The virtual flow meter allows technical and economical constraints, preventing installation of physical instruments in all the needed measurement points, to be overcome. Virtual flow meter performance for the alternative models of Samson [ http://www.samson.de (2015)] and Sereg-Schlumberger [ http://www.slb.com/ (2015)] is compared with the standard IEC 60534-2-1 [Industrial-process control valves—Part 2-1: Flow capacity—sizing equations for fluid flow under installed conditions (2011), https://webstore.iec.ch/publication/2461], for a large temperature range, for both gaseous and liquid helium phases, and for different pressure drops. Then, the calibration function of the transducer is derived. Finally, the experimental validation for the helium gaseous state on the test station for superconducting magnets in the laboratory SM18 [Pirotte et al., AIP Conf. Proc. 1573, 187 (2014)] at CERN is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical Implementation of Failure Mode and Effects Analysis for Safety and Efficiency in Stereotactic Radiosurgery

Purpose: To improve the safety and efficiency of a new stereotactic radiosurgery program with the application of failure mode and effects analysis (FMEA) performed by a multidisciplinary team of health care professionals. Methods and Materials: Representatives included physicists, therapists, dosimetrists, oncologists, and administrators. A detailed process tree was created from an initial high-level process tree to facilitate the identification of possible failure modes. Group members were asked to determine failure modes that they considered to be the highest risk before scoring failure modes. Risk priority numbers (RPNs) were determined by each group member individually and then averaged. Results: A total of 99 failure modes were identified. The 5 failure modes with an RPN above 150 were further analyzed to attempt to reduce these RPNs. Only 1 of the initial items that the group presumed to be high-risk (magnetic resonance imaging laterality reversed) was ranked in these top 5 items. New process controls were put in place to reduce the severity, occurrence, and detectability scores for all of the top 5 failure modes. Conclusions: FMEA is a valuable team activity that can assist in the creation or restructuring of a quality assurance program with the aim of improved safety, quality, and efficiency. Performing the FMEA helped group members to see how they fit into the bigger picture of the program, and it served to reduce biases and preconceived notions about which elements of the program were the riskiest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of high level nuclear waste glass samples following extended melter idling

The Savannah River Site Defense Waste Processing Facility (DWPF) melter was recently idled with glass remaining in the melt pool and riser for approximately three months. This situation presented a unique opportunity to collect and analyze glass samples since outages of this duration are uncommon. The objective of this study was to obtain insight into the potential for crystal formation in the glass resulting from an extended idling period. The results will be used to support development of a crystal-tolerant approach for operation of the high-level waste melter at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Two glass pour stream samples were collected from DWPF when the melter was restarted after idling for three months. The samples did not contain crystallization that was detectible by X-ray diffraction. Electron microscopy identified occasional spinel and noble metal crystals of no practical significance. Occasional platinum particles were observed by microscopy as an artifact of the sample collection method. Reduction/oxidation measurements showed that the pour stream glasses were fully oxidized, which was expected after the extended idling period. Chemical analysis of the pour stream glasses revealed slight differences in the concentrations of some oxides relative to analyses of the melter feed composition prior to the idling period. While these differences may be within the analytical error of the laboratories, the trends indicate that there may have been some amount of volatility associated with some of the glass components, and that there may have been interaction of the glass with the refractory components of the melter. These changes in composition, although small, can be attributed to the idling of the melter for an extended period. The changes in glass composition resulted in a 70-100 °C increase in the predicted spinel liquidus temperature (TL) for the pour stream glass samples relative to the analysis of the melter feed prior to the outage. This indicates that the potential for spinel crystallization increased as a result of idling for an extended period. However, the predicted TL of the pour stream glasses remained 150-200 °C below the mean melt pool temperature of about 1125 °C during the idling period. Given the change in predicted TL over the three month outage, the results indicate that it is important to have a thorough understanding of spinel crystallization within the melter for WTP to operate with a volume percent crystallization constraint. This knowledge will enable process control routines to be developed that avoid bulk crystallization in the melter and allow for recovery from off-normal events. The current WTP crystal-tolerant glass program will develop an improved understanding of spinel crystallization in the WTP melter to allow for operation at maximum waste loading in glass composition systems limited by predictions of spinel crystallization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Amino‐Functionalized CNTs and CVD Grown CNTs for Better Dispersion in Al Powder in the Fabrication of Composites

We report an improved process for the better dispersion of multiwalled carbon nanotubes (MWCNTs) in Al powder used for the fabrication of Al‐matrix composites employing powder metallurgy process. For obtaining a better dispersion of MWCNTs in Al, we used two types of MWCNTs. In the first type, the MWCNTs were firstly functionalized by using ammonium bi‐carbonate and mix with Al powder using a high energy ball mill in the presence of a process control agent. In the second type we grew MWCNTs directly on Al powder using CVD. Various mechanical properties of the composites including micro hardness, compressive strength etc. were determined. It has been observed that using functionalized MWCNTs (fCNTs) and CVD grown MWCNTs, these properties were found to enhance significantly. The dispersion of functionalized CNTs was studied by SEM and the interfacial bonding between functionalized CNTs and Al matrix using high resolution transmission electron microscopy (HRTEM).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal Control of Markov Processes with Age-Dependent Transition Rates

We study optimal control of Markov processes with age-dependent transition rates. The control policy is chosen continuously over time based on the state of the process and its age. We study infinite horizon discounted cost and infinite horizon average cost problems. Our approach is via the construction of an equivalent semi-Markov decision process. We characterise the value function and optimal controls for both discounted and average cost cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microstructural Characterization of Irradiated U{sub 0.17}ZrH{sub 1.6} Using Ultrasonic Techniques

In recent years, there has been an increased level of effort to understand the changes in microstructure that occur due to irradiation of nuclear fuel. The primary driver for this increased effort is the potential for designing new fuels that are safer and more reliable, in turn enabling new and improved reactor technologies. Much of the data on microstructural change in irradiated fuels is generated through a host of post irradiation examination techniques such as optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) to determine grain structure, porosity, crack geometry, etc. in irradiated fuels. Such 'traditional' examination techniques were recently used to characterize a novel new fuel consisting of U{sub 0.17}ZrH{sub 1.6} pellets bonded to zircaloy-2 cladded with lead-bismuth eutectic before and after irradiation. In addition to the conventional suite of post-irradiation examination tools, several nondestructive interrogation techniques exist which bring the potential for in-situ assessment of microstructural changes. One such method, ultrasonic examination, was tested on each of the samples. This paper describes the results of this examination. Ultrasonic measurements have a long and successful history of use for nondestructive materials characterization, including nondestructive evaluation (NDE) of degradation and damage, microstructure characterization, and measurement of physical parameters for process control. Ultrasonic NDE is critical to the nuclear power industry's in-service inspection program for maintaining pressure boundary integrity, and is being actively investigated for PIE of fuels. Ultrasonic measurements, typically performed at 10 MHz or higher, performed post irradiation show that fuel microstructural parameters, such as porosity and grain size, can be correlated to ultrasonic velocity. The objective of this examination was to assess the feasibility of using ultrasonic measurements on irradiated fuel to determine sensitivity to microstructural changes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Genetic algorithms in adaptive fuzzy control

Researchers at the U.S. Bureau of Mines have developed adaptive process control systems in which genetic algorithms (GA's) are used to augment fuzzy logic controllers (FLC's). GA's are search algorithms that rapidly locate near-optimum solutions to a wide spectrum of problems by modeling the search procedures of natural genetics. FLC's are rule based systems that efficiently manipulate a problem environment by modeling the 'rule-of-thumb' strategy used in human decision making. Together, GA's and FLC's possess the capabilities necessary to produce powerful, efficient, and robust adaptive control systems. To perform efficiently, such control systems require a control element to manipulate the problem environment, an analysis element to recognize changes in the problem environment, and a learning element to adjust fuzzy membership functions in response to the changes in the problem environment. Details of an overall adaptive control system are discussed. A specific computer-simulated chemical system is used to demonstrate the ideas presented.

Karr, C. Lucas↗

Synthesis of ceramic powders and surface films from laser heated gases

Two new processes have been developed that are based on laser-heated gases. Both permit unusually precise levels of process control and, thereby, materials having superior properties. The power process yields Si, Si3N4 and SiC powders that are uniform in size, nonagglomerated, small diameter, spherically shaped and high purity. Manufacturing cost analyses show that submicron powders can be made with an energy cost of approximately 2 kWhr/kg and a dollar cost of 2-3.30 $/kg, exclusive of the costs of feed materials. The laser-induced chemical vapor deposition process (LICVD) causes reactant gases to be heated by absorbing IR light from a laser beam that passes parallel to the substrate surface. Laser heating permits independent control of gas and substrate temperatures while operating in a conventional, thermally activated chemical vapor deposition mode. Spin density, hydrogen content, electrical conductivity and mobility gap properties show the LICVD process capable of producing very high quality films.

Haggerty, J. S.↗

Development and Optimization of Normal Pulse Voltammetry for Real Time Analysis of Electrorefiner Salt with High Concentrations of MgCl{sub 2} and UCl{sub 3}

Electro-refiners can accumulate large holdup of fissile actinides from used nuclear fuel including plutonium and will need to be well safeguarded in a commercial facility. Idaho National Laboratory has operated the Fuel Conditioning Facility, an engineering scale demonstration facility, with two electro-refiners for two decades using mass tracking models supplemented with destructive analysis for the requirements of domestic safeguards. This approach is known to be insufficient of meet international safeguards timeliness requirements. Since there are non-nuclear weapons states that are interested in commercial electro-refiners, there is a need to develop a real time concentration measurement technique. In addition to being useful for safeguards, such a real time measurement would be functional for maintaining optimal process control. Normal pulse voltammetry (NPV) is a powerful electrochemical analysis method that has been identified to have great potential for measuring concentrations of various ions in a given salt mixture. While cyclic voltammetry (CV), chronoamperometry (CA), and chronopotentiometry (CP) result in progressive growth of the working electrode surface area, NPV potentially can circumvent this problem via periodically stripping deposited metals from the electrode (WE) surface. With each successive pulse, the potential is dropped to a more negative level. The corresponding current is a summation of partial currents from each of the reducing species. The ultimate objective of this work is to develop correlations between limiting currents measured via NPV with known concentrations. This is potentially a more accurate method than CV and other methods, because it should keep the WE surface area from growing significantly. Previous work on using NPV for actinide concentration determination in eutectic LiCl-KCl has been reported by M. Iizuka et al. However, only low uranium concentrations were studied in that paper. The maximum concentration of uranium tested was 2.48 wt%. Limiting currents from NPV were found to be proportional to their concentrations up to about 1.7 wt%. They were unable to maintain double plateaus (U and Pu) at uranium concentrations above 1.69 w%. This issue was resolved during our high concentration study. This result represents a significant breakthrough for optimizing voltammetry for analysis of actinides in molten salt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-CD-207A-11: Sensitivity Analysis of Action Limits for Real-Time EPID-Based Delivery Verification System Using Artificial Clinical Relevant Error Simulations

Purpose: A real-time patient treatment delivery verification system using EPID (Watchdog) has been developed as an advanced patient safety tool. In a pilot study data was acquired for 119 prostate and head and neck (HN) IMRT patient deliveries to generate body-site specific action limits using statistical process control. The purpose of this study is to determine the sensitivity of Watchdog to detect clinically significant errors during treatment delivery. Methods: Watchdog utilizes a physics-based model to generate a series of predicted transit cine EPID images as a reference data set, and compares these in real-time to measured transit cine-EPID images acquired during treatment using chi comparison (4%, 4mm criteria) after the initial 2s of treatment to allow for dose ramp-up. Four study cases were used; dosimetric (monitor unit) errors in prostate (7 fields) and HN (9 fields) IMRT treatments of (5%, 7%, 10%) and positioning (systematic displacement) errors in the same treatments of (5mm, 7mm, 10mm). These errors were introduced by modifying the patient CT scan and re-calculating the predicted EPID data set. The error embedded predicted EPID data sets were compared to the measured EPID data acquired during patient treatment. The treatment delivery percentage (measured from 2s) where Watchdog detected the error was determined. Results: Watchdog detected all simulated errors for all fields during delivery. The dosimetric errors were detected at average treatment delivery percentage of (4%, 0%, 0%) and (7%, 0%, 0%) for prostate and HN respectively. For patient positional errors, the average treatment delivery percentage was (52%, 43%, 25%) and (39%, 16%, 6%). Conclusion: These results suggest that Watchdog can detect significant dosimetric and positioning errors in prostate and HN IMRT treatments in real-time allowing for treatment interruption. Displacements of the patient require longer to detect however incorrect body site or very large geographic misses will be detected rapidly.

60 APPLIED LIFE SCIENCES↗

Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗