Probing the localization of magnetic dichroism by atomic-size astigmatic and vortex electron beams

We report localization of a magnetic dichroic signal on atomic columns in electron magnetic circular dichroism (EMCD), probed by beam distorted by four-fold astigmatism and electron vortex beam. With astigmatic probe, magnetic signal to noise ratio can be enhanced by blocking the intensity from the central part of probe. However, the simulations show that for atomic resolution magnetic measurements, vortex beam is a more effective probe, with much higher magnetic signal to noise ratio. For all considered beam shapes, the optimal SNR constrains the signal detection at low collection angles of approximately 6–8 mrad. Irrespective of the material thickness, the magnetic signal remains strongly localized within the probed atomic column with vortex beam, whereas for astigmatic probes, the magnetic signal originates mostly from the nearest neighbor atomic columns. Due to excellent signal localization at probing individual atomic columns, vortex beams are predicted to be a strong candidate for studying the crystal site specific magnetic properties, magnetic properties at interfaces, or magnetism arising from individual atomic impurities.

36 MATERIALS SCIENCE↗

Development of atomic radical monitoring probe and its application to spatial distribution measurements of H and O atomic radical densities in radical-based plasma processing

Atomic radicals such as hydrogen (H) and oxygen (O) play important roles in process plasmas. In a previous study, we developed a system for measuring the absolute density of H, O, nitrogen, and carbon atoms in plasmas using vacuum ultraviolet absorption spectroscopy (VUVAS) with a compact light source using an atmospheric pressure microplasma [microdischarge hollow cathode lamp (MHCL)]. In this study, we developed a monitoring probe for atomic radicals employing the VUVAS with the MHCL. The probe size was 2.7 mm in diameter. Using this probe, only a single port needs to be accessed for radical density measurements. We successfully measured the spatial distribution of the absolute densities of H and O atomic radicals in a radical-based plasma processing system by moving the probe along the radial direction of the chamber. This probe allows convenient analysis of atomic radical densities to be carried out for any type of process plasma at any time. We refer to this probe as a ubiquitous monitoring probe for atomic radicals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear servomotor probe drive system with real-time self-adaptive position control for the Alcator C-Mod tokamak

A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enable self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. Finally, in addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability of double probe measurements in nanodusty plasmas

Abstract Nonthermal plasmas are attractive sources for nanoparticles synthesis, however, their plasma properties are notoriously difficult to assess due to the chemically reactive environment and high nanoparticle concentrations. Here, we are using a floating double probe to measure the plasma properties of a nanoparticle-forming argon:silane plasma. We demonstrate good stability of current–voltage characteristics over several minutes of operation. However, unexpectedly larger electron temperatures are measured with increasing the silane mole fraction. To test the validity of these results, we developed a zero-dimensional global model to investigate the effect of the presence of nanoparticles on the plasma properties. Using this model, we show that increasing particle concentration leads to an increasing electronegativity of the plasma, causing an increase of the reduced electric field. However, this causes only a moderate increase in mean electron energy, in contrast to the much larger increase measured by the double probe. We argue that these large electron temperatures are based on the fact that a double probe measures an ‘apparent’ electron temperature, which is defined by the negative inverse slope of the logarithm of the electron energy probability function (EEPF) at an energy corresponding to the probe’s floating potential. As the silane mole fraction is increased, the plasma becomes more electronegative and the probe’s floating potential moves closer to the plasma potential. Combined with the strong non-Maxwellian EEPF, this leads to the large apparent electron temperatures obtained by the probe. Thus, the apparent electron temperatures measured with the double probe do not follow the trends in mean electron energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing Signal Design for Power System Identification

This paper investigates the design of effective input signals for low-level probing of power systems. In 2005, 2006, and 2008 the Western Electricity Coordinating Council (WECC) conducted four large-scale system wide tests of the western interconnected power system where probing signals were injected by modulating the control signal at the Celilo end of the Pacific DC intertie. A major objective of these tests is the accurate estimation of the inter-area electromechanical modes. A key aspect of any such test is the design of an effective probing signal that leads to measured outputs rich in information about the modes. This paper specifically studies low-level probing signal design for power-system identification. The paper describes the design methodology and the advantages of this new probing signal which was successfully applied during these tests. This probing input is a multi-sine signal with its frequency content focused in the range of the inter-area modes. The period of the signal is over two minutes providing high-frequency resolution. Up to 15 cycles of the signal are injected resulting in a processing gain of 15. The resulting system response is studied in the time and frequency domains. Because of the new probing signal characteristics, these results show significant improvement in the output SNR compared to previous tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flux Detection Probe to Quantify Dynamic Groundwater-Surface Water Exchange in the Hyporheic Zone

A new probe was designed to quantify groundwater-surface water exchange in the hyporheic zone under dynamic stage condition. Current methods focus on either vertical pore water velocity or Darcy flux measurements. Both parameters must be understood to evaluate residence time and mass flux of constituents. Furthermore, most instruments are not well suited for monitoring instantaneous velocity or flux under dynamic exchange conditions. For this reason, the flux detection probe (FDP) was designed that employs electrogeophysical measurements to estimate in situ sediment porosity, which can be used to convert pore water velocity to Darcy flux. Dynamic pore water velocity is obtained by monitoring fluid conductivity and temperature along the FDP probe. Pressure sensors deployed at the top and bottom of the probe provide the additional information necessary to estimate vertical permeability. This study focuses on the use of a geophysical method to estimate pore water velocity, porosity, and permeability within a controlled soil column where simulated river water displaces simulated groundwater. The difference between probe derived and theoretical pore water velocity using natural tracers such as electrical conductivity and temperature was -4.9 and 3.9% for downward flow and 1.1 and 12.8% for upward flow, respectively. The difference in porosity calculated from mass and volume packed in the soil column and probe measure porosity ranged between -3.2% and 1.5%. Also, the calculated hydraulic conductivity differed from probe derived values by -8.9%.

54 ENVIRONMENTAL SCIENCES↗

Assessing probe-specific dye and slide biases in two-color microarray data

Background: A primary reason for using two-color microarrays is that the use of two samples labeled with different dyes on the same slide, that bind to probes on the same spot, is supposed to adjust for many factors that introduce noise and errors into the analysis. Most users assume that any differences between the dyes can be adjusted out by standard methods of normalization, so that measures such as log ratios on the same slide are reliable measures of comparative expression. However, even after the normalization, there are still probe specific dye and slide variation among the data. We define a method to quantify the amount of the dye-by-probe and slide-by-probe interaction. This serves as a diagnostic, both visual and numeric, of the existence of probe-specific dye bias. We show how this improved the performance of two-color array analysis for arrays for genomic analysis of biological samples ranging from rice to human tissue. Results: We develop a procedure for quantifying the extent of probe-specific dye and slide bias in two-color microarrays. The primary output is a graphical diagnostic of the extent of the bias which called ECDF (Empirical Cumulative Distribution Function), though numerical results are also obtained. Conclusion: We show that the dye and slide biases were high for human and rice genomic arrays in two gene expression facilities, even after the standard intensity-based normalization, and describe how this diagnostic allowed the problems causing the probe-specific bias to be addressed, and resulted in important improvements in performance. The R package LMGene which contains the method described in this paper has been available to download from Bioconductor.

59 BASIC BIOLOGICAL SCIENCES↗

Green’s function for a sharpened and metal-coated dielectric probe

In apertureless scanning-probe optical microscopy and in the case of more traditional scanned optical probes coated with a metal that is thin near the probe tip (in lieu of an aperture), samples are probed via interaction between the probe and surface. In the nanometer-scale region between the tip and the sample, the field can be approximated by quasi-electrostatic analytics. Hence, the coated probe can be modeled as in the present case as a hyperboloid of revolution without the need for hyperboloidal wave functions in the near zone. The solutions to Laplace’s equation and in general Green’s function with the application of the boundary conditions, therefore, yield an appropriate approximation and allow a completely analytical solution for the resonance effects upon the probe tip to be obtained. In conclusion, the large field enhancements due to the sharpness of the tip and to surface plasmon fields may thus be analytically examined.

47 OTHER INSTRUMENTATION↗

Tentacle Probes™: Differentiation of Difficult Single-Nucleotide Polymorphisms and Deletions by Presence or Absence of a Signal in Real-Time PCR

Abstract Background: False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation differentiation. Methods: Tentacle Probes™, cooperative reagents with both a capture and a detection probe based on specific cell-targeting principles, were developed as a replacement for 2 chromosomal TaqMan–minor groove binder (MGB) assays previously developed for Yersinia pestis and Bacillus anthracis detection. We compared TaqMan-MGB probes to Tentacle Probes for SNP and deletion detection based on the presence or absence of a growth curve. Results: With the TaqMan-MGB Y. pestis yp48 assays, false-positive results for Yersinia pseudotuberculosis occurred at every concentration tested, and with the TaqMan-MGB B. anthracis gyrA assays, false-positive results occurred in 21 of 29 boil preps of environmental samples of near neighbors. With Tentacle Probes no false-positive results occurred. Conclusions: The high specificity exhibited by Tentacle Probes may eliminate melting curve analysis for SNP and deletion mutation detection, allowing the diagnostic use of previously difficult targets.

Satterfield, Brent C.↗

Validation of DNA probes for molecular cytogenetics by mapping onto immobilized circular DNA

Fluorescence in situ hybridization (FISH) is a sensitive and rapid procedure to detect gene rearrangements in tumor cells using non-isotopically labeled DNA probes. Large insert recombinant DNA clones such as bacterial artificial chromosome (BAC) or P1/PAC clones have established themselves in recent years as preferred starting material for probe preparations due to their low rates of chimerism and ease of use. However, when developing probes for the quantitative analysis of rearrangements involving genomic intervals of less than 100kb, careful probe selection and characterization are of paramount importance. We describe a sensitive approach to quality control probe clones suspected of carrying deletions or for measuring clone overlap with near kilobase resolution. The method takes advantage of the fact that P1/PAC/BAC's can be isolated as circular DNA molecules, stretched out on glass slides and fine-mapped by multicolor hybridization with smaller probe molecules. Two examples demonstrate the application of this technique: mapping of a gene-specific {approx}6kb plasmid onto an unusually small, {approx}55kb circular P1 molecule and the determination of the extent of overlap between P1 molecules homologous to the human NF-{kappa}B2 locus. The relatively simple method presented here does not require specialized equipment and may thus find widespread applications in DNA probe preparation and characterization, the assembly of physical maps for model organisms or in studies on gene rearrangements.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear servomotor probe drive system with real-time self-adaptive position control for the Alcator C-Mod tokamak

A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enables self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. In addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outer planet entry probe system study. Volume 1: Summary

General mission considerations and science prospectus, which are of a general nature that applies to several or all planetary applications, are presented. Five probe systems are defined: nominal Jupiter probe system, and Jupiter probe-dedicated alternative probe system, Jupiter spacecraft radiation-compatible alternative probe system, Saturn probe system, and Saturn probe applicability for Uranus. Parametric analysis is summarized for mission analysis of a general nature, and then for specific missions to Jupiter, Saturn, Uranus, and Neptune. The program is also discussed from the hardware availability viewpoint and the aspect of commonality.

Source record↗

Properties of the wake of small Langmuir probes on sounding rockets

Split Langmuir probes have been used to study the near wake of small Langmuir probes on sounding rockets. Experiments have been performed on two rocket flights using planar disk and cylindrical geometries, and the results are presented. Significant wake perturbations in plasma density and temperature were found due to the probe body itself, even though the probes were of the order of or smaller than the Debye length. The largest effects of the wake are seen in the electron collection characteristics of the probe. The wake of small probes show apparent magnetic field aligned structure, even though the probes were much smaller than the ion gyroradius. On one flight, a space charge potential large enough to substantially alter photoemission, -3.5 volts, was observed.

Bering, E. A.↗

Probe corrected far-field reconstruction from measurements on a cylinder: A novel formulation and efficient algorithm

A novel and numerically efficient method of far field evaluation from measurements taken on a cylinder is based on the representation of both the antenna and the probe fields as superpositions of plane waves. A system of two integral equations are established whose unknown functions are the azimuthal and elevation components of the antenna pattern and whose known terms are the set of measurement data taken with two different probes - the second probe in most practical instances being simply the same probe with a different geometrical orientation. The equations express the known data - for each angular position of the antenna under measurement - as the integrals of the products of the corresponding components of the unknown antenna and known probe patterns multiplied by a phase term. The convolutional nature of the integral equations makes their solutions straight-forward. If, as is virtually always the case, the probe is small or of moderate size so that the axis of rotation of the antenna mount is in the far field of the probe, the intervention of asymptotic techniques makes the solution numerically very efficient. The agreement of calculated and experimental patterns is excellent.

Borgiotti, G. V.↗

The infinite line pressure probe

The infinite line pressure probe provides a means for measuring high frequency fluctuating pressures in difficult environments. A properly designed infinite line probe does not resonate; thus its frequency response is not limited by acoustic resonance in the probe tubing, as in conventional probes. The characteristics of infinite line pressure probes are reviewed and some applications in turbine engine research are described. A probe with a flat-oval cross section, permitting a constant-impedance pressure transducer installation, is described. Techniques for predicting the frequency response of probes with both circular and flat-oval cross sections are also cited.

Englund, D. R.↗