Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

The Value of Distributed Wind: A Valuation Framework

While there has been an increase in distributed energy resource (DER) adoption, particularly for solar photovoltaic (PV) DERs, distributed wind deployment is still relatively low. However, distributed wind has significant growth potential for behind-the-meter applications and can provide improved resource diversity and resilience in high-DER grid systems. In order to make optimized decisions about distributed wind deployment, it is important to identify and characterize the value streams of distributed wind in a way that will help policy makers, microgrid developers, utilities, project developers, and others understand the potential value of distributed wind. In our paper, we develop a framework to provide a consistent and comprehensive approach to finding the net benefits of distributed wind to various stakeholders in different scenarios. We do this by considering the main use cases for distributed wind, and then developing a framework which is flexible for these various use cases and the relevant stakeholders while maintaining the same overall structure for analysis. Ongoing work includes applying this framework to valuing two distributed wind power systems, one in a remote village in Alaska and one in a front-of-the-meter deployment in Iowa. Our analysis aims to understand the full value that distributed wind is providing in these systems, including the resilience benefits it is contributing. As a better understanding of distributed wind valuation is gained, it will be easier for stakeholders to make informed decisions in order to have resilient renewable energy systems.

17 WIND ENERGY↗

Scalable/Secure Cooperative Algorithms and Framework for Extremely-high Penetration Solar Integration (SolarExPert) (Final Technical Report)

This SolarExPert project has developed a Sustainable Grid Platform (SGP) with scalable architecture of distributed control and optimization. The SGP consists of the following major functions: 1) an advanced grid architecture with hierarchical and distributed communication and control, combined with the OpenFMB standard and implemented on the Multi-Agent OpenDSS (MA-OpenDSS) platform; 2) an online distributed stochastic optimal power flow; 3) an online distributed system state estimation algorithm; 4) the distributed Volt/VAR optimization and frequency control algorithms; 5) the distributed distribution system restoration strategy. The developed SGP together with advanced functions are tested in 1 million (1M)-node distribution system on the MA-OpenDSS platform. Furthermore, the models and algorithms are tested in 100,000-node system HiL simulation, and also in P-HiL implementation with 100 physical devices. The developed functions haven been validated and tested on the selected actual distribution feeder with the data collected from the field of Maui Meadows in Hawaii. The distributed PV hosting capacities with cooperative Volt/VAR and Volt/VAR/Watt control are estimated and compared to provide recommendations for customers and the utility company.

14 SOLAR ENERGY↗

Fermi-type particle acceleration from magnetic reconnection at the termination shock of a relativistic striped wind

An oblique-rotating pulsar generates a relativistic striped wind in a pulsar wind nebula (PWN). The termination shock of the PWN compresses the Poynting-flux-dominated flow and drives magnetic reconnection. By carrying out particle-in-cell simulations of the termination shock of the PWN, we study the shock structure as well as the energy conversion processes and particle acceleration mechanisms. With the recent advances in the numerical methods, we extend the simulations to the ultrarelativistic regime with a bulk Lorentz factor of up to γ 0 = 10 6 . Magnetic reconnection at the termination shock is highly efficient at converting magnetic energy to particle kinetic energy and accelerating particles to high energies. Similar to earlier studies, we find that the resulting energy spectra crucially depend on λ/d e (λ is the wavelength of the striped wind and de is the relativistic plasma skin depth). When λ/d e is large (λ ≳ 40d e ), the downstream particle spectra form a power-law distribution in the magnetically dominated relativistic wind regime. By analyzing particle trajectories and statistical quantities relevant to particle energization, we find that Fermi-type mechanism dominates the particle acceleration and power-law formation. We find that the results for particle acceleration are scalable as γ 0 and σ 0 increase to large values. The maximum energy for electrons and positrons can reach hundreds of TeV if the wind has a bulk Lorentz factor of γ0 ≈ 106 and a magnetization parameter of σ 0 = 10, which can explain the recent observations of high-energy gamma rays from PWNe

79 ASTRONOMY AND ASTROPHYSICS↗

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

97 MATHEMATICS AND COMPUTING↗

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Imaging electron angular distributions to assess a full-power petawatt-class laser focus

Here we present a technique to assess the focal volume of petawatt-class lasers at full power. Our approach exploits quantitative measurement of the angular distribution of electrons born in the focus via ionization of rarefied gas, which are accelerated forward and ejected ponderomotively by the field. We show that a bivariate (θ,Φ) angular distribution, which was obtained with image plates, not only enables the peak intensity to be extracted, but also reflects nonideality of the focal-spot intensity distribution. In our prototype demonstration at intensities of a few ×10 19 to a few ×10 20 W/cm 2 , an f/10 optic produced a focal spot in the paraxial regime. This allows a plane-wave parametrization of the peak intensity given by tanθ c =2/a 0 (a 0 being the normalized vector potential and θ c the minimum ejection angle) to be compared with our measurements. Qualitative agreement was found using an a 0 inferred from the pulse energy, pulse duration, and focal spot distribution with a modified parametrization, tanθ c =2η/a 0 ($η=2.02^{+0.26}_{–0.22}$). This highlights the need for (i) better understanding of intensity degradation due to focal-spot distortions and (ii) more robust modeling of the ejection dynamics. Using single-shot detection of electrons, we showed that while there is significant shot-to-shot variation in the number of electrons ejected at a given angular position, the average distribution scales with the pulse energy in a way that is consistent with that seen with the image plates. Finally, we note that the asymptotic behavior as θ→0° limits the usability of angular measurement. For 800 nm, this limit is at an intensity ~10 21 W/cm 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plan It Together: Optimizing Across Generation, Transmission, Distribution, and Distributed Energy Resources

Integrated planning holds the promise of unlocking lower total system cost solutions by connecting previously siloed planning processes. This article summarizes the state of bulk and local grid planning today and details multiple new analytical approaches that can enable more holistic planning methods to develop comprehensive solutions to generation, transmission, distribution, and distributed energy resource needs. These include both iterative approaches as well as cooptimization techniques. In addition to the benefits of these methods, the technical and institutional challenges and associated solutions are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors

The protection, control, and monitoring of the power grid is not possible without accurate measurement devices. As the percentage of renewable energy sources penetrating the existing grid infrastructure increases, so do uncertainties surrounding their effects on the everyday operation of the power system. Many of these devices are sources of high-frequency transients. These transients may be useful for identifying certain events or behaviors otherwise not seen in traditional analysis techniques. Therefore, the ability of sensors to accurately capture these phenomena is paramount. In this work, two commercial-grade power system distribution sensors are investigated in terms of their ability to replicate high-frequency phenomena by studying their responses to three events: a current inrush, a microgrid “close-in”, and a fault on the terminals of a wind turbine. Kernel density estimation is used to derive the non-parametric probability density functions of these error distributions and their adequateness is quantified utilizing the commonly used root mean square error (RMSE) metric. It is demonstrated that both sensors exhibit characteristics in the high harmonic range that go against the assumption that measurement error is normally distributed.

47 OTHER INSTRUMENTATION↗

Using an Advanced Distribution Management System Test Bed to Evaluate the Impact of Model Quality on Volt/VAR Optimization: Preprint

In this paper, we present a test bed for evaluating existing and future advanced distribution management system (ADMS) applications in a realistic laboratory setting, including other utility management systems and field equipment. We present an example of using it to evaluate the impact of the ADMS network model quality on a Volt/VAR optimization (VVO) application. The test bed integrates a commercial ADMS with a real-time simulation model of a utility distribution feeder. Representative power and controller hardware are integrated through hardware-in-the-loop (HIL) techniques. The performance of the ADMS VVO application is also evaluated for different levels of measurement density. Initial results indicate that a higher model quality achieves the highest possible energy savings while avoiding voltage violations, whereas a lower model quality results in increased energy savings but at the expense of more voltage violations.

ADMS↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Simulations of divertor designs that spatially separate power and particle exhaust using mid-leg divertor particle pumping

Predictive design modeling of a Dissipation-Focused Divertor for future operation in DIII-D reveals that increasing the poloidal distance of the pump duct entrance from the target surface along the low-field side divertor baffle increases neutral compression and modifies the spatial distribution of power dissipation. With a divertor pump located mid-leg between the target and the X-point, SOLPS-ITER boundary plasma simulations without drifts predict the formation of a dense neutral cloud near the target with > 30x higher neutral compression in detachment, a more stable detachment front located further from the target, and ~25% lower outer midplane separatrix density required for detachment onset, compared to a pump located in the scrape-off layer at the target surface. Up to 19 MW of power flowing into the divertors is modeled using the following two numerical implementations for particle pumping: a specified fraction of particles incident on variable wall sections of the plasma grid is removed from the computational domain (so-called albedo pumping), and a pump duct is modeled which includes dynamics of kinetic neutrals in the duct. The simulations show that the detachment front is located between the divertor target and the X-point and is relatively stable near the pump entrance, without a strong dependence on gas puff rate or injected power. The mid-leg pump design spatially separates the two primary functions of a divertor (power handling and particle exhaust), with the majority of power dissipation occurring near the target plate and particle exhaust taking place further upstream. The benefit of enhanced dissipation using mid-leg pumping comes at the cost of a higher outer midplane separatrix density for a given amount of particle injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishing metrics to quantify spatial similarity in spherical and red blood cell distributions

As computational power increases and systems with millions of red blood cells can be simulated, it is important to note that varying spatial distributions of cells may affect simulation outcomes. Since a single simulation may not represent the ensemble behavior, many different configurations may need to be sampled to adequately assess the entire collection of potential cell arrangements. In order to determine both the number of distributions needed and which ones to run, we must first establish methods to identify well-generated, randomly placed cell distributions and to quantify distinct cell configurations. We utilize metrics to assess (1) the presence of any underlying structure to the initial cell distribution and (2) similarity between cell configurations. We propose the use of the radial distribution function to identify long-range structure in a cell configuration and apply it to a randomly distributed and structured set of red blood cells. To quantify spatial similarity between two configurations, we make use of the Jaccard index, and characterize sets of red blood cell and sphere initializations. As an extension to our work submitted to the International Conference on Computational Science, we significantly increase our data set size from 72 to 1048 cells, include a similar set of studies using spheres, compare the effects of varying sphere size, and utilize the Jaccard index distribution to probe sets of extremely similar configurations. Our results show that the radial distribution function can be used as a metric to determine long-range structure in both distributions of spheres and RBCs. We determine that the ideal case of spheres within a cube versus bi-concave shaped cells within a cylinder affects the shape of the Jaccard index distributions, as well as the range of Jaccard values, showing that both the shape of particle and the domain may play a role. Furthermore, we also find that the distribution is able to capture very similar configurations through Jaccard index values greater than 95% when appending several nearly identical configurations into the data set.

59 BASIC BIOLOGICAL SCIENCES↗

Effectively Considering the Distribution System in Integrated Resource Plans

While electricity planning practices vary by state and utility based on utility type and market structure, integrated resource planning (IRP) remains a prominent vehicle — even in states with centrally-organized wholesale electricity markets. IRP focuses on meeting forecasted long-term electricity needs. Typically, utilities have not considered impacts of design and operation of the low-voltage distribution network in IRP. With advanced capabilities of grid-edge technologies to generate and store electricity and provide load flexibility, and large utility investments in distribution systems, it's increasingly important to consider at least some distribution planning elements in IRP. This report considers the value proposition for doing so, such as reducing utility costs through resource co-optimization and strategic siting of grid-edge resources, and idenfities the most important touchpoints between planning for bulk power and distribution systems and provide a range of tactics for integrating these two processes.

Relf, Grace [Lawrence Berkeley National Laboratory↗

Feeder Power Disaggregation: A Data-Efficient Matrix Completion Approach: Preprint

This paper presents a data-driven algorithm for the feeder power disaggregation problem in distribution systems. Leveraging spatio-temporal power patterns in residential homes, residential power is discomposed into three components: sparse-switching loads, periodic loads, and photovoltaic generation, using two sparse matrices and a rank-one matrix. The matrix completion process is data-efficient because of the matrix sparsity and low rankness, along with the use of power system models. The proposed approach is tested using real-world residential datasets on a 33-bus distribution system, demonstrating accurate power disaggregation with efficient matrix completion.

distribution system↗

Distributed Cooperative Control of Hybrid AC/DC Microgrid

This paper presents a distributed cooperative control-based power management algorithm for a hybrid AC/DC microgrid. The proposed algorithm for a hybrid microgrid system controls the power flow through the interface converter between the AC and DC microgrids. This algorithm allows power sharing between the distributed generators in the microgrid according to their power ratings. Moreover, it enables the fixed scheduled power delivery through the interface converters in both directions at different operating conditions while maintaining voltage regulation and improving the frequency profile. The effectiveness of the controller is confirmed by simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗