Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYSTYRENE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Estimation of Purcell factor from mode-splitting spectra in an optical microcavity

We investigate scattering process in an ultrahigh-Q optical microcavity coupled to subwavelength scatterers by introducing splitting quality Q{sub sp}, a dimensionless parameter defined as the ratio of the scatterer-induced mode splitting to the total loss of the coupled system. A simple relation is introduced to directly estimate the Purcell factor from single-shot measurement of transmission spectrum of scatterer-coupled cavity. Experiments with polystyrene (PS) and gold (Au) nanoparticles, erbium ions, and Influenza A virions show that Purcell-factor-enhanced preferential funneling of scattering into the cavity mode takes place regardless of the scatterer type. Experimentally determined highest Q{sub sp} for single PS and Au nanoparticles are 9.4 and 16.19 corresponding to Purcell factors with lower bounds of 353 and 1049, respectively. The highest observed Q{sub sp} was 31.2 for an ensemble of Au particles. These values are the highest Q{sub sp} and Purcell factors reported up to date.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Casimir interaction between two magnetodielectric plates

We investigate the thermal Casimir interaction between two magnetodielectric plates made of real materials. On the basis of the Lifshitz theory, it is shown that for diamagnets and for paramagnets in the broad sense (with exception of ferromagnets) the magnetic properties do not influence the magnitude of the Casimir force. For ferromagnets, taking into account the realistic dependence of magnetic permeability on frequency, we conclude that the impact of magnetic properties on the Casimir interaction arises entirely from the contribution of the zero-frequency term in the Lifshitz formula. The computations of the Casimir free energy and pressure are performed for the configurations of two plates made of ferromagnetic metals (Co and Fe), for one plate made of ferromagnetic metal and the other of nonmagnetic metal (Au), for two ferromagnetic dielectric plates (on the basis of polystyrene), and for a ferromagnetic dielectric plate near a nonmagnetic metal plate. The dielectric permittivity of metals is described using both the Drude and the plasma model approaches. It is shown that the Casimir repulsion through the vacuum gap can be realized in the configuration of a ferromagnetic dielectric plate near a nonmagnetic metal plate described by the plasma model. In all cases considered, the respective analytical results in the asymptotic limit of large separations between the plates are obtained. The impact of the magnetic phase transition through the Curie temperature on the Casimir interaction is considered. In conclusion, we propose several experiments allowing to determine whether the magnetic properties really influence the Casimir interaction and to independently verify the Drude and plasma model approaches to the thermal Casimir force.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of K + production cross section by 8 GeV protons using high energy neutrino interactions in the SciBooNE detector

The SciBooNE Collaboration reports K + production cross section and rate measurements using high energy daughter muon neutrino scattering data off the SciBar polystyrene (C 8 H 8 ) target in the SciBooNE detector. The K + mesons are produced by 8 GeV protons striking a beryllium target in Fermilab Booster Neutrino Beam line (BNB). Using observed neutrino and antineutrino events in SciBooNE, we measure d 2 σ/dpdΩ = (5.34 ±0.76) mb/(GeV/c x sr) for p + Be =K + + X at mean K + energy of 3.9 GeV and angle (with respect to the proton beam direction) of 3.7 degrees, corresponding to the selected K + sample. Compared to Monte Carlo predictions using previous higher energy K + production measurements, this measurement, which uses the NUANCE neutrino interaction generator, is consistent with a normalization factor of 0.85 ± 0.12. This agreement is evidence that the extrapolation of the higher energy K + measurements to an 8 GeV beam energy using Feynman scaling is valid. This measurement reduces the error on the K + production cross section from 40% to 14%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental evidence of nonthermal acceleration of relativistic electrons by an intensive laser pulse

Nonthermal acceleration of relativistic electrons is investigated with an intensive laser pulse. An energy distribution function of energetic particles in the universe or cosmic rays is well represented by a power-law spectrum, therefore, nonthermal acceleration is essential to understand the origin of cosmic rays. A possible candidate for the origin of cosmic rays is wakefield acceleration at relativistic astrophysical perpendicular shocks. The wakefield is considered to be excited by large-amplitude precursor light waves in the upstream of the shocks. Substituting an intensive laser pulse for the large amplitude light waves, we performed a model experiment of the shock environments in a laboratory plasma. An intensive laser pulse was propagated in a plasma tube created by imploding a hollow polystyrene cylinder, as the large amplitude light waves propagated in the upstream plasma at an astrophysical shock. Nonthermal electrons were generated, and the energy distribution functions of the electrons have a power-law component with an index of {approx}2. We described the detailed procedures to obtain the nonthermal components from data obtained by an electron spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoparticle Motion within Glassy Polymer Melts

X-ray photon correlation spectroscopy is employed to investigate the motion of dilute suspensions of gold nanoparticles in low-molecular-weight polystyrene melts. At high temperatures, the observed motion is diffusive, with a rate that follows a Vogel-Fulcher temperature dependence. Closer to the glass transition temperature T{sub g}, diffusion is superseded by a hyperdiffusive process that first becomes observable near a crossover temperature T{sub c} {approx} 1.1 T{sub g} and is identified with heterogeneous strain in the melts. Following rapid cooling to temperatures sufficiently below T{sub c}, but still above T{sub g}, the hyperdiffusive dynamics displays a time dependence similar to aging in polymer glasses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Evidence of Impact Ignition: 100-Fold Increase of Neutron Yield by Impactor Collision

We performed integrated experiments on impact ignition, in which a portion of a deuterated polystyrene (CD) shell was accelerated to about 600 km/s and was collided with precompressed CD fuel. The kinetic energy of the impactor was efficiently converted into thermal energy generating a temperature of about 1.6 keV. We achieved a two-order-of-magnitude increase in the neutron yield by optimizing the timing of the impact collision, demonstrating the high potential of impact ignition for fusion energy production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Entanglement-Controlled Subdiffusion of Nanoparticles within Concentrated Polymer Solutions

We describe x-ray photon correlation spectroscopy (XPCS) experiments tracking the motion of gold nanoparticles within solutions of high-molecular-weight polystyrene. Over displacements from nanometers to tens of nanometers, the particles undergo subdiffusive motion that is dictated by the temporal evolution of the entangled polymer mesh in the immediate vicinity of the particles. The results thus provide a novel microscopic dynamical characterization of this key structural property of polymers and more broadly demonstrate the capability of XPCS-based microrheology to interrogate heterogeneous mechanical environments in nanostructured soft materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of swift heavy ion irradiation on the hardness of chromium nanorods

The present study reports the use of swift heavy ion irradiation as a means to tailor the hardness of chromium nanorod coatings. Arrays of slanted and straight Cr nanorods, 1-2 {mu}m long and 300-500 nm in diameter, were grown by dc magnetron sputter glancing angle deposition on Si(100) substrates patterned with 500 nm diameter polystyrene spheres. The samples were irradiated with 100 MeV Ag{sup +8} ions at three different fluence values of 10{sup 13}, 5x10{sup 13}, and 10{sup 14} ions/cm{sup 2}, while maintaining the samples at 80 K temperature. The as-deposited samples exhibit a fibrous structure that smoothens after irradiation. Nanoindentation tests performed on these samples reveal that the hardness of the nanorods increases with fluence. For slanted nanorods, the samples irradiated at maximum fluence show an almost 300% increase in hardness as compared to their pristine counterparts. The corresponding increase in the case of straight nanorods was observed to be 77%. This fluence-dependent hardness in Cr nanorods is explained in terms of an ion-irradiation induced defect formation and a decrease in the grain size, as confirmed by glancing angle x-ray diffraction.

36 MATERIALS SCIENCE↗

X-ray photoelectron spectroscopy analysis of organic materials etched by charged water droplet impact

Electrospray droplet impact (EDI) has been developed for matrix-free secondary ion mass spectrometry for surface analysis. When a target is etched by EDI, the physical etching on the target is suppressed to minimal, i.e., the occurrence of shallow surface etching. A novel approach to shallow surface etching of polystyrene (PS) by EDI was investigated. The charged water droplets were irradiated to a bulk and a spin coated PS. After irradiation, these samples were analyzed by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy. It was found that XPS spectra for PS were independent on the irradiation time by EDI. This indicates that EDI is a unique technique for the surface etching of the organic materials without leaving any damage on the etched surface.

36 MATERIALS SCIENCE↗

Fabrication of ZnO photonic crystals by nanosphere lithography using inductively coupled-plasma reactive ion etching with CH{sub 4}/H{sub 2}/Ar plasma on the ZnO/GaN heterojunction light emitting diodes

This article reports fabrication of n-ZnO photonic crystal/p-GaN light emitting diode (LED) by nanosphere lithography to further booster the light efficiency. In this article, the fabrication of ZnO photonic crystals is carried out by nanosphere lithography using inductively coupled plasma reactive ion etching with CH{sub 4}/H{sub 2}/Ar plasma on the n-ZnO/p-GaN heterojunction LEDs. The CH{sub 4}/H{sub 2}/Ar mixed gas gives high etching rate of n-ZnO film, which yields a better surface morphology and results less plasma-induced damages of the n-ZnO film. Optimal ZnO lattice parameters of 200 nm and air fill factor from 0.35 to 0.65 were obtained from fitting the spectrum of n-ZnO/p-GaN LED using a MATLAB code. In this article, we will show our recent result that a ZnO photonic crystal cylinder has been fabricated using polystyrene nanosphere mask with lattice parameter of 200 nm and radius of hole around 70 nm. Surface morphology of ZnO photonic crystal was examined by scanning electron microscope.

36 MATERIALS SCIENCE↗

Glancing angle deposition of Ge nanorod arrays on Si patterned substrates

A periodic arrangement of Ge nanorods on a Si(111) substrate was realized by glancing angle deposition (GLAD) onto honeycomb-like arranged Au hillocks formed using a self-assembled monolayer of polystyrene nanospheres as an evaporation mask. Additionally, a honeycomb-like arrangement of Au dots was used as an etch mask in a reactive ion beam etching process for pattern transfer procedure. Resulting honeycomb patterns consisting of Si hillocks within the Si(111) substrates were utilized to deposit Ge nanorods. Effective morphological variations in shape and dimension of GLAD-grown nanorods on honeycomb-like patterned substrates with both Au dot and Si dot arrays are strongly influenced by interseed distances, seed heights, and consequently shadowing lengths. For a large pattern period, it was observed that the usual triangular shape of the nanorod changed to a hexagonal shape as an effect of additional particle flux that reached the growing nanorod from the direction of second and third-nearest neighbors due to inadequate shadowing lengths and increased interseed condensation.

36 MATERIALS SCIENCE↗

Interaction of Long-lived Reactive Species from Cold Atmospheric Pressure Plasma with Polymers: Chemical Modification by Ozone and Reactive Oxygen-Nitrogen Species

Atmospheric pressure plasma (APP) sources are able to generate a variety of reactive species that have different effects on materials, such as functionalization, etching and deposition. In this article, we study the effect of long-lived reactive neutral species on polymers using a model plasma-surface interaction (PSI) system that consists of ultra-thin (~10 nm) polystyrene (PS) films and a surface micro-discharge (SMD) reactor operated with various N 2 /O 2 working gas mixtures. We characterized and quantified the reactive species generated by SMD using IR and UV absorption, and we found that O 3 , N 2 O 5 , N 2 O and HNO 3 are the dominant long-lived reactants near the target surface. When exposing PS films to these reactive species, we observed material responses including film thickness expansion, surface and bulk oxidation, and surface organic nitrate formation. The quantity of these changes varied with the N 2 /O 2 working gas composition. By correlating material response with gas phase species, we find that the chemical modification of PS strongly depends on the density of O 3 in the gas phase, which is indicative of an essential role of O 3 in the remote APP treatment of polymers. Our results show that O 3 causes polymer surface oxidation, participates in the diffusion-reaction process in the polymer bulk, and results in aromatic ring cleavage and the formation of carbonyl groups. In contrast, we did not find a correlation between surface organic nitrate and individual long-lived reactive species mentioned above. This indicates that surface organic nitrate formation on polymer surfaces might result from the interaction of multiple reactive species, including O 3 and nitrogen containing species. A model for the interphase mass transfer of reactive species from gas to solid was also described.

36 MATERIALS SCIENCE↗

A system for intensity modulated dose plan verification based on an experimental pencil beam kernel obtained by deconvolution

The number of intensity modulated radiation therapy (IMRT) procedures is continuously growing worldwide and it is necessary to develop tools for patient specific quality assurance (QA) that avoid using machine time that could be employed in treating additional patients. One way of achieving this goal is to perform a multileaf collimator quality assurance periodically in the linear accelerator and check the treatment planning system (TPS) calculation by employing an independent calculation system. Within the work frame of the pencil beam kernel approach, a new system was developed for obtaining an experimental kernel. This new technique is based on a deconvolution procedure using the Hankel transform. The resulting kernel is obtained in a way completely independent of those employed in commercial treatment planning systems, usually calculated by Monte Carlo simulations. Also provided are comparisons between calculated and measured doses with radiographic film, linear array of diodes, and ionization chamber. Measurements taken in polystyrene and water for clinical IMRT plans demonstrate that this method can calculate IMRT dose distributions, as well as treatment times, with great accuracy. Apart from other applications, it can be used as a double-check algorithm for IMRT QA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center Francois Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the dose measurements performed with the DosiMap and with dosimetric films for three different irradiation configurations showed discrepancies smaller than 3.5% for a 2 mm spatial resolution. Two innovative discrimination solutions were demonstrated to separate the scintillation from the Cerenkov radiation. It was also shown that the DosiMap, which is water equivalent, fast, and user friendly, is a very promising tool for radiotherapy quality assurance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of EGSnrc calculations at {sup 60}Co energies for the response of ion chambers configured with various wall materials and cavity dimensions

In this investigation, five experimental data sets are used to evaluate the ability of the EGSnrc Monte Carlo code to calculate the change in chamber response associated with changes in wall material and cavity dimension at {sup 60}Co energies. Calculations of the ratios of response per unit mass of air as a function of cavity volume for walls ranging from polystyrene to lead are generally within 1%-3% of experiments. A few exceptions, which are discussed, include 20%-30% discrepancies with experiments involving lead-walled chambers used by Attix et al. [J. Res. Natl. Bur. Stand. 60, 235-243 (1958)] and Cormack and Johns [Radiat. Res. 1, 133-157 (1954)], and 5% discrepancies for the graphite chamber of Attix et al. (relative to data for other wall materials). Simulations of the experiment by Whyte [Radiat. Res. 6, 371-379 (1957)], which varied cavity air pressure in a large cylindrical chamber, are generally within 0.5% (wall/electrode materials ranging from beryllium to copper). In all cases, the agreement between measurements and EGSnrc calculations is much better when the response as a function of cavity height or air pressure is considered for each wall material individually. High-precision measurements [Burns et al., Phys. Med. Biol. 52, 7125-7135 (2007)] of the response per unit mass as a function of cavity height for a graphite chamber are also accurately reproduced, and validate previous tests of the transport mechanics of EGSnrc. Based on the general agreement found in this work between corresponding experimental results and EGSnrc calculations it can be concluded that EGSnrc can reliably be used to calculate changes in response with changes in various wall materials and cavity dimensions at {sup 60}Co energies within a accuracy of a few percent or less.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simplifying EPID dosimetry for IMRT treatment verification

Purpose: Electronic portal imaging devices (EPIDs) are increasingly used for IMRT dose verification, both pretreatment and in vivo. In this study, an earlier developed backprojection model has been modified to avoid the need for patient-specific transmission measurements and, consequently, leads to a faster procedure. Methods: Currently, the transmission, an essential ingredient of the backprojection model, is estimated from the ratio of EPID measurements with and without a phantom/patient in the beam. Thus, an additional irradiation to obtain ''open images'' under the same conditions as the actual phantom/patient irradiation is required. However, by calculating the transmission of the phantom/patient in the direction of the beam instead of using open images, this extra measurement can be avoided. This was achieved by using a model that includes the effect of beam hardening and off-axis dependence of the EPID response on photon beam spectral changes. The parameters in the model were empirically obtained by performing EPID measurements using polystyrene slab phantoms of different thickness in 6, 10, and 18 MV photon beams. A theoretical analysis to verify the sensitivity of the model with patient thickness changes was performed. The new model was finally applied for the analysis of EPID dose verification measurements of step-and-shoot IMRT treatments of head and neck, lung, breast, cervix, prostate, and rectum patients. All measurements were carried out using Elekta SL20i linear accelerators equipped with a hydrogenated amorphous silicon EPID, and the IMRT plans were made using PINNACLE software (Philips Medical Systems). Results: The results showed generally good agreement with the dose determined using the old model applying the measured transmission. The average differences between EPID-based in vivo dose at the isocenter determined using either the new model for transmission and its measured value were 2.6{+-}3.1%, 0.2{+-}3.1%, and 2.2{+-}3.9% for 47 patients treated with 6, 10, and 18 MV IMRT beams, respectively. For the same group of patients, the differences in mean {gamma} analysis (3% maximum dose, 3 mm) were 0.16{+-}0.26%, 0.21{+-}0.24%, and 0.02{+-}0.12%, respectively. For a subgroup of 11 patients, pretreatment verification was also performed, showing similar dose differences at the isocenter: -1.9{+-}0.9%, -1.4{+-}1.2%, and -0.4{+-}2.4%, with somewhat lower mean {gamma} difference values: 0.01{+-}0.09%, 0.01{+-}0.07%, and -0.09{+-}0.10%, respectively. Clinical implementation of the new model would save 450 h/yr spent in measurement of open images. Conclusions: It can be concluded that calculating instead of measuring the transmission leads to differences in the isocenter dose generally smaller than 2% (2.6% for 6 MV photon beams for in vivo dose) and yielded only slightly higher {gamma}-evaluation parameter values in planes through the isocenter. Hence, the new model is suitable for clinical implementation and measurement of open images can be omitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric verification of surface and superficial doses for head and neck IMRT with different PTV shrinkage margins

Purpose: Dosimetric uncertainty in the surface and superficial regions is still a major concern for radiation therapy and becomes more important when using the inverse planning algorithm for IMRT. The purpose of this study was to measure dose distributions and to evaluate the calculation accuracy in the superficial region for different planning target volume (PTV) shrinkage methods for head and neck IMRT plans. Methods: A spherical polystyrene phantom 160 mm in diameter (ball phantom) was used to simulate the shape of the head. Strips of superflab bolus with thicknesses of 3.5 and 7.0 mm were spread on the surface of the ball phantom. Three sets of CT images were acquired for the ball phantom without and with the bolus. The hypothetical clinical target volume (CTV) and critical structures (spinal cord and parotid glands) were outlined on each set of CT images. The PTVs were initially created by expanding an isotropic 3 mm margin from the CTV and then margins of 0, 3, and 5 mm were shrunk from the phantom surface for dosimetric analysis. Seven-field IMRT plans with a prescribed dose of 180 cGy and same dose constraints were designed using an Eclipse treatment planning system. Superficial doses at depths of 0, 3.5, and 7.0 mm and at seven beam axis positions (gantry angles of 0 deg., 30 deg., 60 deg., 80 deg., 330 deg., 300 deg., and 280 deg.) were measured for each PTV shrinkage margin using 0.1 mm ultrathin thermoluminescent dosimeters. For each plan, the measured doses were compared to the calculated doses. Results: The PTV without shrinkage had the highest intensity and the steepest dose gradient in the superficial region. The mean measured doses for different positions at depths of 0, 3.5, and 7.0 mm were 106{+-}18, 185{+-}16, and 188{+-}12 cGy, respectively. For a PTV with 3 mm shrinkage, the mean measured doses were 94{+-}13, 183{+-}8, and 191{+-}8 cGy. For a PTV with 5 mm shrinkage, the mean measured doses were 86{+-}11, 173{+-}8, and 187{+-}5 cGy. The comparisons indicated that more than 73.3% of the calculated points are with doses lower than the measured points and the difference of the dose becomes more significant in the shallower region. At 7.0 mm depth, the average difference between calculations and measurements was 2.5% (maximum 5.5%). Conclusions: Application of the PTV shrinkage method should take into account the calculation inaccuracy, tumor coverage, and possible skin reaction. When the tumor does not invade the superficial region, an adequate shrinkage margin from the surface is helpful for reducing the skin reaction. As the tumor invades the superficial region, adding a bolus is a method better than only contouring PTV with skin inclusion.

60 APPLIED LIFE SCIENCES↗