Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

AntBot: Anti-pollution peer-to-peer botnets

Botnets, which are responsible for many email sparnming and DDoS (Distributed Denial of Service) attacks in the current Internet, have emerged as one of most severe cyber-threats in recent years. To evade detection and improve resistance against countermeasures, botnets have evolved from the first generation that relies on IRC chat channels to deliver commands to the current generation that uses highly resilient P2P (Peer-to-Peer) protocols to spread their C&C (Command and Control) information. It is, however, revealed that P2P botnets, although relieved from the single point of failure that IRC botnets suffer, can be easily disrupted using pollution-based mitigation schemes [15]. In this paper, we play the devil's advocate and propose a new type of hypothetical botnets called AntBot, which aim to propagate their C&C information to individual bots even though there exists an adversary that persistently pollutes keys used by seized bots to search the command information. The key idea of AntBot is a tree-like structure that bots use to deliver the command so that captured bots reveal only limited information. To evaluate effectiveness of AntBot against pollution-based mitigation in a virtual environment, we develop a distributed P2P botnet simulator. Using extensive experiments, we demonstrate that AntBot operates resiliently against pollution-based mitigation. We further present a few potential defense schemes that could effectively disrupt AntBot operations.

97 MATHEMATICS AND COMPUTING↗

Traffic-related air pollution and childhood obesity in an Italian birth cohort

Highlights: • Few studies analyse the association between air pollution and children BMI. • We modelled traffic-related air pollution with land-use regression models. • Inverse Probability Weighting (IPW) has been used to control for selection bias. • No association was found between pollutants and ponderal excess parameters. Air pollution is associated with several adverse health outcomes in children, such as respiratory illnesses and cognitive development impairment. There are suggestions of an effect of traffic-related air pollution on the occurrence of childhood obesity, but the results are not consistent.

54 ENVIRONMENTAL SCIENCES↗

Annual Storm Water Report for the Y-12 National Security Complex Oak Ridge, Tennessee

The storm water pollution prevention program at the Y-12 National Security Complex (Y-12 Complex) intends to protect the quality of storm water runoff through: (1) reducing the exposure of metal accumulation areas to precipitation, (2) implementation of Best Management Practices, (3) sampling during rain events and subsequent analysis, and (4) routine surveillances. When prescribed, the analytical data is compared to a set of cut-off concentration values to determine how the Y-12 Complex relates to other metal fabrication industries in the state of Tennessee. The quality of the storm water exiting the Y-12 Complex via East Fork Poplar Creek indicated some improvement in 2011. This improvement is attributable to the completion of several construction, demolition and remediation projects which occurred in 2010 and 2011. Emphasis will continue to be placed on site inspections and the timely implementation of improved storm water control measures as deemed necessary.

54 ENVIRONMENTAL SCIENCES↗

Photosynthetic photon flux, photoperiod, and temperature effects on emissions of (Z)-3-hexenal, (Z)-3-hexenol, and (Z)-3-hexenyl acetate from lettuce

To investigate the effects of environment on plant volatile emissions, 'Waldmann's Green' leaf lettuce was cultivated under different levels of photosynthetic photon flux (PPF), photoperiod, and temperature. A modified growth chamber was used to sample plant volatile emissions nondestructively, over time, and under controlled conditions. Total volatile emission rates were significantly higher from lettuce cultivated under PPF of 360 or 200 micromoles m-2 s-1 compared to 105 micromoles m-2 s-1, and significantly higher under a 16-h photoperiod than an 8-h photoperiod. No differences were detected among emission rates from different temperature treatments. In controlled environments, emissions could be regulated by adjusting environmental conditions accordingly.

NASA Program Advanced Life Support↗

Management of multiple groundwater contaminant plumes extending beyond property boundaries at the young - Rainey STAR Center (Science, Technology, and Research Center) - 15623

The US DOE Pinellas Plant-now known as the Young - Rainey STAR Center, located in Largo, Florida-manufactured components for nuclear weapons from 1956 to 1995. During decades of operations, chlorinated solvents were released from a drum storage area and from underground piping at multiple points adjacent to and beneath a 4.5-hectare (11-acre) building. Two groundwater contaminant plumes associated with contaminant sources beneath the building have been identified, delineated, and are being monitored. During a focused delineation campaign in 2008 to better define the plume boundaries prior to municipal construction projects in the area, the plumes were determined to extend beyond the site boundaries, beneath the adjacent roadway easements, and beneath four adjacent privately owned properties. US DOE has performed a number of activities in response to the discovery of the offsite contaminant plumes, including performing a high-resolution delineation of contaminant plumes; coordinating with local municipalities to complete two linear construction projects requiring dewatering in the vicinity of the plumes; performing risk assessment, risk management, risk communication, and community relations tasks associated with the project; coordinating with state regulators to identify a risk-based corrective action regulatory approach; and coordinating with impacted property owners to develop and implement institutional controls. During the replacement of a 1.2-meter (48-inch) municipal potable water line directly over the contaminant plume area, US DOE (1) constructed infrastructure to receive and treat dewatering effluent at a rate of 20 gallons per minute around the clock for 6 weeks, and (2) conducted breathing-zone air monitoring during excavation of a 3.0-meter (10-foot) deep trench. This degree of diligence was necessary to ensure and document that no site workers were exposed to chlorinated solvent vapors during the construction process, and that a large volume of potentially contaminated groundwater was properly treated and dispositioned. US DOE also took aggressive actions to pro-actively address claims regarding loss of property value on two properties associated with the groundwater contamination, which resulted in a teaming arrangement with each party for future management of the ongoing corrective actions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rethinking Occupancy - Based Ventilation Controls

Traditionally, occupancy-based ventilation controls have only ventilated when occupants are present – usually based on measurements of CO2 and/or humidity. These indictors may be fine for pollutants released directly by occupants, such as bioeffluents, or by their activities, such as cooking and cleaning. However, they do not account for pollutants not associated with occupancy, such as formaldehyde from building materials and furnishings. In this study we examined how occupancy-based ventilation controls could account for these other pollutants using the relative exposure approach for variable ventilation. A real-time control was used for exhaust and balanced fans, three occupancy schedules and two different pollutant emission assumptions using the REGCAP ventilation and residential energy simulation program. The simulations were performed for a prototype high performance home compliant with U.S. Department of Energy Building America Zero Energy Ready program requirements in the 15 climate zones defined by the U.S. DOE. Median ventilation energy savings were between zero and 26% of ventilation-related energy use depending on the occupancy schedule, climate, fan type and emission assumptions. Occupancy-based control savings increased for balanced ventilation fans, reduced emissions during unoccupied periods, and longer unoccupied times. Accounting for pollutant emissions during unoccupied times significantly reduces the energy savings for occupancy-based controls.

Walker, Iain↗

Modulation of Uptake and Reactivity of Nitrogen Dioxide in Metal-Organic Framework Materials

We report the modulation of reactivity of nitrogen dioxide (NO 2 ) in a charged metal–organic framework (MOF) material, MFM-305-CH 3 in which unbound N-centres are methylated and the cationic charge counter-balanced by Cl - ions in the pores. Uptake of NO 2 into MFM-305-CH 3 leads to reaction between NO 2 and Cl - to give nitrosyl chloride (NOCl) and NO 3 - anions. A high dynamic uptake of 6.58 mmol g -1 at 298 K is observed for MFM-305-CH 3 as measured using a flow of 500 ppm NO 2 in He. In contrast, the analogous neutral material, MFM-305, shows a much lower uptake of 2.38 mmol g -1 . The binding domains and reactivity of adsorbed NO 2 molecules within MFM-305-CH 3 and MFM-305 have been probed using in situ synchrotron X-ray diffraction, inelastic neutron scattering and by electron paramagnetic resonance, high-field solid-state nuclear magnetic resonance and UV/Vis spectroscopies. The design of charged porous sorbents provides a new platform to control the reactivity of corrosive air pollutants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying dominant sources of respirable suspended particulates in Guangzhou, China

Respirable suspended particulates (RSP, i.e., particles with an aerodynamic diameter of 10 {mu} m or less) were measured in 2004 and 2005 at seven sites in the rapidly developing Guangzhou area of China. The average RSP concentration was 126 {mu} g m{sup -3}, a high level that could be very harmful to human health. The chemical species composition of the RSP, including organic and elemental carbon, water-soluble ions, and elemental compositions, was also analyzed. The organics and sulfate may be the major components of RSP mass concentrations. Positive matrix factorization (PMF) was used to identify the sources of RSP as secondary sulfates (32%), secondary nitrates (6%), biomass burning (15%), coal fly ash/cement (18%), sea salt (3%), crustal dust (5%), vehicle exhaust (6%), and coal-fired power plants (3%). Reducing coal combustion and controlling vehicle emissions would alleviate RSP pollution, as most of the precursors were components of coal burning emissions and vehicular exhaust.

01 COAL, LIGNITE, AND PEAT↗

National Energy Efficiency Evaluation, Measurement and Verification (EM&V) Standard: Scoping Study of Issues and Implementation Requirements

This report is a scoping study that identifies issues associated with developing a national evaluation, measurement and verification (EM&V) standard for end-use, non-transportation, energy efficiency activities. The objectives of this study are to identify the scope of such a standard and define EM&V requirements and issues that will need to be addressed in a standard. To explore these issues, we provide and discuss: (1) a set of definitions applicable to an EM&V standard; (2) a literature review of existing guidelines, standards, and 'initiatives' relating to EM&V standards as well as a review of 'bottom-up' versus 'top-down' evaluation approaches; (3) a summary of EM&V related provisions of two recent federal legislative proposals (Congressman Waxman's and Markey's American Clean Energy and Security Act of 2009 and Senator Bingaman's American Clean Energy Leadership Act of 2009) that include national efficiency resource requirements; (4) an annotated list of issues that that are likely to be central to, and need to be considered when, developing a national EM&V standard; and (5) a discussion of the implications of such issues. There are three primary reasons for developing a national efficiency EM&V standard. First, some policy makers, regulators and practitioners believe that a national standard would streamline EM&V implementation, reduce costs and complexity, and improve comparability of results across jurisdictions; although there are benefits associated with each jurisdiction setting its own EM&V requirements based on their specific portfolio and evaluation budgets and objectives. Secondly, if energy efficiency is determined by the US Environmental Protection Agency to be a Best Available Control Technology (BACT) for avoiding criteria pollutant and/or greenhouse gas emissions, then a standard can be required for documenting the emission reductions resulting from efficiency actions. The third reason for a national EM&V standard is that such a standard is likely to be required as a result of future federal energy legislation that includes end-use energy efficiency, either as a stand-alone energy-efficiency resource standard (EERS) or as part of a clean energy or renewable energy standard. This study is focused primarily on this third reason and thus explores issues associated with a national EM&V standard if energy efficiency is a qualifying resource in federal clean energy legislation. Developing a national EM&V standard is likely to be a lengthy process; this study focuses on the critical first step of identifying the issues that must be addressed in a future standard. Perhaps the most fundamental of these issues is 'how good is good enough?' This has always been the fundamental issue of EM&V for energy efficiency and is a result of the counter-factual nature of efficiency. Counter-factual in that savings are not measured, but estimated to varying degrees of accuracy by comparing energy consumption after a project (program) is implemented with what is assumed to have been the consumption of energy in the absence of the project (program). Therefore, the how good is good enough question is a short version of asking how certain does one have to be of the energy savings estimate that results from EM&V activities and is that level of certainty properly balanced against the amount of effort (resources, time, money) that is utilized to obtain that level of certainty. The implication is that not only should energy efficiency investments be cost-effective, but EM&V investments should consider risk management principles and thus also balance the costs and value of information derived from EM&V (EM&V should also be cost-effective).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Navajo Generating Station and Air Visibility Regulations: Alternatives and Impacts

Pursuant to the Clean Air Act, the U.S. Environmental Protection Agency (EPA) announced in 2009 its intent to issue rules for controlling emissions from Navajo Generating Station that could affect visibility at the Grand Canyon and at several other national parks and wilderness areas. The final rule will conform to what EPA determines is the best available retrofit technology (BART) for the control of haze-causing air pollutants, especially nitrogen oxides. While EPA is ultimately responsible for setting Navajo Generating Station's BART standards in its final rule, it will be the U.S. Department of the Interior's responsibility to manage compliance and the related impacts. This study aims to assist both Interior and EPA by providing an objective assessment of issues relating to the power sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quiet Clean Short-haul Experimental Engine (QCSEE) under-the-wing engine digital control system design report

A digital electronic control was combined with conventional hydromechanical components to operate the four controlled variables on the under-the-wing engine: fuel flow, fan blade pitch, fan exhaust area, and core compressor stator angles. The engine and control combination offers improvements in noise, pollution, thrust response, operational monitoring, and pilot workload relative to current engines.

Source record↗

Remote Detection of Biological Particles and Chemical Plumes Using UV Fluorescence Lidar

A lidar system based on ultraviolet (UV) laser induced fluorescence (LIF) was developed for the remote detection of atmospherically dispersed biological particles and chemical vapors. This UV fluorescence lidar has many potential applications for monitoring environmental pollution, industrial waste emission, agricultural insect control, illicit chemical processing, and military defense operations. The general goal of this work is to investigate the research issues associated with the long range detection and identification of chemicals, e.g. aromatic solvents and chemical precursors, and biological materials, e.g. bacillus thuringiensis (BT) and bacillus globiggi (BG). In the detection of biological particulates, we are particularly interested in extending the detection range of an existing solar-blind 248-nm lidar system. We are investigating the use of longer excitation laser wavelengths (i.e. lambda greater than 280-nm to have more favorable atmospheric light transmission characteristics) for improving detection range to better than 10 km. In the detection of chemical plumes, our main research objectives are to determine how accurately and sensitively a chemical plume can be located at range, and how well spectrally the chemical species can be measured to allow their identification.

J J Tiee↗

Long-range pollution transport during the MILAGRO-2006 campaign: a case study of a major Mexico City outflow event using free-floating altitude-controlled balloons

One of the major objectives of the Megacities Initiative: Local And Global Research 3 Observations (MILAGRO 2006) campaign was to investigate the long-range transport of 4 Mexico City Metropolitan Area (MCMA) pollution outflow and its downwind impacts on air 5 quality and climate. Four aircraft (DOE G-1, NSF/NCAR C-130, NASA-J31, and NASA 6 DC-8) made extensive chemical, aerosol, and radiation measurements above MCMA and over 7 1000 km downwind in order to characterize the evolution of MCMA pollution as it aged and 8 dispersed over the central Mexican plateau and the Gulf of Mexico. As part of this effort, 9 free-floating Controlled-Meteorological (CMET) balloons, capable of changing altitude on 10 command via satellite, characterized the MCMA outflow by performing repeated soundings 11 during the transit. In this paper, we present an analysis based on the data from two CMET 12 balloons that were launched near Mexico City on the afternoon of 18 March 2006 and floated 13 downwind with the outflow for nearly 30 hours. Continuous profile measurements made by 14 the balloons show the evolving structure of the MCMA outflow in considerable detail: its 15 stability and stratification, interaction with other air masses, mixing episodes, and dispersion 16 into the regional background. Air parcel trajectories, computed directly from the balloon 17 wind profiles, show three different transport pathways for Mexico City outflow on 18-19 18 March: (a) high-altitude advection of the top of the MCMA mixed layer, (b) low-altitude flow 19 over the Sierra Madre Oriental followed by decoupling and isolated transport over the Gulf, 20 and (c) the same decoupling scenario with entrainment into a cleaner westerly jet below the 21 plateau. The C-130 intercepted the balloon-based trajectories three times on 19 March, once 22 along each transport pathway. In all three cases, distinct peaks in the urban tracer signature 23 and LIDAR backscatter imagery provided evidence for Mexico City air. The coherence of the 24 high-altitude outflow was well preserved after 25 hours whereas that lower in the atmosphere 25 was more widely dispersed over the same time period. Other C-130 intercepts, previously 26 thought to be from Mexico City, are shown to have likely originated elsewhere. These 27 findings address key questions about the long-range transport of Mexico City pollution and its 28 impact on the regional background. The particular intercepts identified should prove useful in 29 answering a wide range scientific questions pertaining to the transport, transformation, and 30 downwind impacts of megacity air pollution. 31 32

54 ENVIRONMENTAL SCIENCES↗

Noise Protection

Environmental Health Systems puts forth an increasing effort in the U.S. to develop ways of controlling noise, particularly in industrial environments due to Federal and State laws, labor union insistence and new findings relative to noise pollution impact on human health. NASA's Apollo guidance control system aided in the development of a noise protection product, SMART. The basis of all SMART products is SMART compound a liquid plastic mixture with exceptional energy/sound absorbing qualities. The basic compound was later refined for noise protection use.

Source record↗

Spatial assessment of net mercury emissions from the use of fluorescent bulbs

While fluorescent lighting is an important technology for reducing electrical energy demand, mercury used in the bulbs is an ongoing concern. Using state and country level data, net emissions of mercury from the marginal use of fluorescent lightbulbs are examined for a base year of 2004 for each of the 50 United States and 130 countries. Combustion of coal for electric power generation is generally the largest source of atmospheric mercury pollution; reduction in electricity demand from the substitution of incandescent bulbs with fluorescents leads to reduced mercury emissions during the use of the bulb. This analysis considers the local mix of power sources, coal quality, thermal conversion efficiencies, distribution losses, and any mercury control technologies that might be in place. Emissions of mercury from production and end-of-life treatment of the bulbs are also considered, providing a life-cycle perspective. Net reductions in mercury over the entire life cycle range from -1.2 to 97 mg per bulb depending on the country. The consequences for atmospheric mercury emissions of several policy scenarios are also discussed. 46 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Measurements of stable isotope ratios in milk samples from a farm placed in the mountains of Transylvania

Product origin is of great importance for consumers especially because its association in consumer's perception with food quality, freedom from disease or pollution. Stable isotope ratio analysis is a powerful technique in food authenticity and traceability control which has been introduced within the European wine industry to ensure authenticity of wine provenance and to detect adulteration. Isotopic ratios measurements have also been successfully to other food commodities like: fruit juices, honey and dairy foods. The δ{sup 18}O and δ{sup 2}H content in milk water reflects the isotope composition of the ground water drunk by animals. Seasonal effects are also very important: in summer, milk water contains higher δ{sup 18}O and δ{sup 2}H values due to the fresh plants that are ate by animals. Relative carbon stable isotope abundances in total milk reflect the isotopic composition of the diet fed to the dairy cows. In this study the hydrogen, oxygen and carbon isotopic composition of 15 milk samples coming from a unit placed in the mountains of Transylvania was investigated. The distribution of the obtained isotopic values was than discussed taking into account that all the animals were feed with the same type of forage and consumed water was taken from the same source.

54 ENVIRONMENTAL SCIENCES↗

Stormwater Pollution Prevention Plan (SWPPP) for Coal Storage Area Stabilization Project

The scope of this project is to stabilize the abandoned coal storage area and redirect the storm water runoff from sanitary sewer system to the storm drain system. Currently, the existing storm water runoff is directed to a perimeter concrete drainage swale and collected in a containment basin. The collected water is then pumped to a treatment facility and after treatment, is discharged to the Y-12 sanitary sewer system. The existing drainage swale and collection basin along with silt fencing will be used during aggregate placement and grading to provide erosion and sediment control. Inlet protection will also be installed around existing structures during the storm water diversion construction. This project scope will include the installation of a non-woven geotextile fabric and compacted mineral aggregate base (paving optional) to stabilize the site. The geotextile specifications are provided on the vendor cut sheets in Appendix B. The installation of a storm water collection/retention area will also be installed on the southern side of the site in accordance with EPA Technical Guidance on Implementing the Stormwater Runoff Requirements for federal Projects under Section 438 of the Energy Independence and Security Act. The total area to be disturbed is approximately 2.5 acres. The order of activities for this Stormwater Pollution Prevention Plan (SWPPP) will be: (1) post notice of coverage (NOC) in a prominent display near entrance of the site; (2) install rain gauge on site or contact Y-12 Plant Shift Superintendent daily for Met tower rain gauge readings; (3) install stabilized construction exit on site; (4) install silt fencing along perimeter as indicated on the attached site plan; (5) regrade site; (6) install geotextile fabric and compacted mineral aggregate base; (7) install catch basin inlet protection where required; (8) excavate and lower existing catch basin tops, re-grade and asphalt to drain; and (9) when all disturbed areas are re-stabilized, remove silt fencing and any other temporary erosion control.

01 COAL, LIGNITE, AND PEAT↗

Comment on 'Air Emissions Due to Wind and Solar Power'

Katzenstein and Apt investigate the important question of pollution emission reduction benefits from variable generation resources such as wind and solar. Their methodology, which couples an individual variable generator to a dedicated gas plant to produce a flat block of power, is, however, inappropriate. For CO{sub 2}, the authors conclude that variable generators ''achieve {approx}80% of the emission reductions expected if the power fluctuations caused no additional emissions.'' They find even lower NO{sub x} emission reduction benefits with steam injected gas turbines and a 2--4 times net increase in NO{sub x} emissions for systems with dry NO{sub x} control unless the ratio of energy from natural gas to variable plants is greater than 2:1. A more appropriate methodology, however, would find a significantly lower degradation of the emissions benefit than suggested by Katzenstein and Apt.

14 SOLAR ENERGY↗