Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Galileo Institute for Astronomy (IFA) charge-coupled device (CCD) system

A fully portable self-contained charge-coupled device system has been constructed for shared use with the Galileo Project Imaging Team. The detector currently incorporated in the system is a Texas Instruments 500 x 500 three-phase CCD that has been thinned to operate in the backside illuminated mode. The detector and camera mainframe electronics were provided by the Jet Propulsion Laboratory. The support electronics and control interfaces necessary to operate the mainframe were constructed. The data system, which is built around a DeAnza Visacom VC-5000 Image Processor with an imbedded LSI-11 minicomputer, was also integrated. The capability to do image processing in real-time at the telescope has proved to be extremely valuable. The overall system read noise has been measured at 25 electrons. Full-well capacity is 40,000 electrons. Some results from laboratory tests and initial observing runs at the Mauna Kea 2.2-m telescope are presented.

Hlivak, R. J.↗

Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators

Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.

Dick, G. John↗

A Harmonics Interferometric Doppler Sensor With a Neon Lamp Detector

A cost-effective harmonic interferometric Doppler sensor has been developed to obtain both amplitude and phase of the micro-Doppler signatures of moving objects. A phase chopper is used to generate the harmonics of the interferometry signal. For cost-effectiveness, a Gunn diode source is used for signal generation and a neon lamp is employed as a broadband detector. An advanced signal processing algorithm has been developed to extract both amplitude and phase Doppler signatures. A prototype has been built to demonstrate the effectiveness of the harmonic interferometric Doppler sensor at 35 GHz, with Doppler objects such as human hand and metal objects. In addition, the broadband detection capability of the neon lamp allows the Doppler sensor to work up to the millimeter-wave regime and potentially beyond the terahertz (THz) wave regime. Due to the ruggedness of the neon lamp detector, it is expected that the Doppler sensor has important applications of sensing and wireless communication in harsh environment such as high-temperature, high-power and radioactive conditions.

Doppler sensor↗

Upgrades to the gamma ray imager on DIII-D enabling access to high flux hard x-ray measurements during the runaway electron plateau phase (invited)

The Gamma Ray Imager (GRI) is a pinhole camera providing 2D imaging of MeV hard x-ray (HXR) bremsstrahlung emission from runaway electrons (REs) over the poloidal cross section of the DIII-D tokamak. We report a series of upgrades to the GRI expanding the access to RE scenarios from the diagnosis of a trace amount of REs to high flux HXR measurements during the RE plateau phase. We present the implementation of novel gamma ray detectors based on LYSO and YAP crystals coupled to multi-pixel photon counters, enabling a count rate in excess of 1 MHz. Finally, we highlight new insights into the RE physics discovered during the current quench and RE plateau phase experiments as the result of these upgrades.

Lvovskiy, A. (ORCID:0000000236491169)↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acquisition and Tracking Behavior of Phase-Locked Loops

Phase-locked or APC loops have found increasing applications in recent years as tracking filters, synchronizing devices, and narrowband FM discriminators. Considerable work has been performed to determine the noise-squelching properties of the loop when it is operating in or near phase lock and is functioning as a linear coherent detector. However, insufficient consideration has been devoted to the non-linear behavior of the loop when it is out of lock and in the process of pulling in. Experimental evidence has indicated that there is a strong tendency for phase-locked loops to achieve lock under most circumstances. However, the analysis which has appeared in the literature iis limited to the acquisition of a constant frequency reference signal with only one phase-locked loop filter configuration. This work represents an investigation of frequency acquisition properties of phase-locked loops for a variety of reference-signal behavior and loop configurations

Viterbi, A. J.↗

Quantum enhanced magneto-optical microscopy and spectroscopy

A system comprising a nonlinear medium (NLM), an optical transduction module, a dual homodyne detector and a processor is provided. The NLM receives at least a pump beam and issues the pump, probe and conjugate beams, where the beams are linearly polarized. Optics route the probe, the conjugate or both beams to the sample. The sample imparts polarization rotation to light that interacts therewith. The optical transduction module imparts to the interacted light an optical phase shift that is a 1:1 transduction of the polarization rotation, where at least one of the probe light or the conjugate light carries the imparted optical phase shift. The processor obtains the optical-phase shift based on respective detection signals from the dual homodyne detector and determines, based on the obtained optical-phase shift, at least one of a Faraday polarization rotation, a Kerr polarization rotation or a spin noise spectrum.

Lawrie, Benjamin J.↗

A pion-argon cross section measurement in the ProtoDUNE-SP experiment with cosmogenic muon

Neutrinos are tiny mysterious fundamental particles with small cross sections. Through neutrino physics, scientists across the world are trying to answer many intriguing questions about nature such as the dominance of matter over antimatter, CP violation in the lepton sector, number of supernovas in the early universe, etc. Detection of neutrinos requires massive particle detectors and intense neutrino beam owing to their small cross section. Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment that is planned to start taking data beginning in 2026. DUNE will consist of 4 massive detectors, the first of which will be using single-phase liquid argon time projection chamber (LArTPC) technology. The ProtoDUNE-SP experiment is a prototype of the DUNE built at the CERN neutrino platform and uses the same detector technology that will be used in DUNE first module. The ProtoDUNE-SP experiment collected months of test beam and cosmic ray data beginning in September 2018. It was built to provide a testbed for the installation of detector parts for DUNE, showing long-term stability of the detector, understanding detector response for different test beam particles (including protons, pions, electrons, kaons, muons), and measurement of hadron-argon cross sections. When a particle passes through LArTPC electron-ion pairs are produced. To reconstruct the position and energy of a particle passing through the medium knowledge of ionization electron drift velocity is essential. The electron drift velocity is distorted by an excess positive charge built up in the detector, known as space charge. This study discusses a novel technique for measuring the ionization electron drift velocity using cosmic-ray muons. The technique uses tracks that travel the entire drift distance of the TPC for drift velocity determination. Secondly, the study discusses a method for converting the charge deposited into energy. The method is carried out in two step s. In th e first step detector response for energetic cosmic ray muons crossing the entire the TPC is used to make the charge deposition uniform throughout the TPC, and in the second step stopping cosmic-ray muons are used for determining the energy scale. Finally, the study discusses a pion-argon cross section measurement based on reweighting of Monte Carlo simulations using J. Calcutt's Geant4Reweight framework. Neutrinos cannot be directly detected; they are identified based on the interaction products. Pions are a common interaction product in a neutrino interaction. For precise modeling of neutrino event generators, it is essential to understand the pion-argon interaction. Pion-argon cross section measurement serves as an important input for neutrino interaction models. The results of the pion-argon total reaction cross section using the Geant4 reweighting technique are found to be in good agreement with Geant4 predictions. The many studies carried out in the ProtoDUNE-SP experi ment wil l be useful for current and future neutrino experiments using LArTPC technology including ICARUS, MicroBooNE, DUNE

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

The role of ProtoDUNE-SP in future oscillation physics

Long-baseline oscillation experiments are entering a new phase where neutrino beams can provide ultra-high fuxes over long distances. These beams will lead to an era of high statistics in large neutrino detectors, creating new systematic uncertainty-limited analyses. The Deep Underground Neutrino Experiment (DUNE) plans a high fux beam to travel 1300 km to 10-kT liquid argon detector modules. While neither the near detector nor the far detector has been constructed, prototypes of the DUNE Far Detector have been built and operated at CERN. One prototype, ProtoDUNE Single-Phase, is a full-scale mockup of the first 10-kT DUNE Far Detector module and can inform DUNE on detector performance and particle passage in argon. The proceedings discuss some published and in-progress results from ProtoDUNE-SP and how these results can impact current sensitivity studies and future analyses.

Diurba, Richard↗

Double DVCS Measurement with the CLAS12 High-Luminosity Upgrade [Slides]

CLAS12 has a diverse physics program, with its detector commissioned in 2018 and since then acquiring physics data. The detector performance is close to design after improvements from AI-assisted tracking, but luminosity upgrades will greatly help efficiently execute the existing physics program and facilitate new physics opportunities. Two phases of luminosity increases are planned. The first, a doubling to 2x10 35 cm -2 s -1 , is in progress with an additional, fast tracking layer and en route in the next 3 years. The second, larger, phase, to 10 37 cm -2 s -1 , converts CLAS12’s forward acceptance region into a muon detector. μCLAS12 in the 2 nd phase is one of only two facilities in the world that can measure DDVCS, extending access to GPDs into new kinematic space. It also can provide, for example, access to heavy quarkonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

A 65 nm CMOS analog processor with zero dead time for future pixel detectors

Next generation pixel chips at the High-Luminosity (HL) LHC will be exposed to extremely high levels of radiation and particle rates. In the so-called Phase II upgrade, ATLAS and CMS will need a completely new tracker detector, complying with the very demanding operating conditions and the delivered luminosity (up to 5×10 34 cm –2 s –1 in the next decade). This work is concerned with the design of a synchronous analog processor with zero dead time developed in a 65 nm CMOS technology, conceived for pixel detectors at the HL-LHC experiment upgrades. It includes a low noise, fast charge sensitive amplifier featuring a detector leakage compensation circuit, and a compact, single ended comparator that guarantees very good performance in terms of channel-to-channel dispersion of threshold without needing any pixel-level trimming. A flash ADC is exploited for digital conversion immediately after the charge amplifier. In conclusion, a thorough discussion on the design of the charge amplifier and the comparator is provided along with an exhaustive set of simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurements with the CMS DAQ and Timing Hub prototype-1

The DAQ and Timing Hub is an ATCA hub board designed for the Phase-2 upgrade of the CMS experiment. In addition to providing high-speed Ethernet connectivity to all back-end boards, it forms the bridge between the sub-detector electronics and the central DAQ, timing, and trigger control systems. One important requirement is the distribution of several high-precision, phase-stable, and LHC synchronous clock signals for use by the timing detectors. The current paper presents first measurements performed on the initial prototype, with a focus on clock quality. It is demonstrated that the current design provides adequate clock quality to satisfy the requirements of the Phase-2 CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FlameNEST: explicit profile likelihoods with the Noble Element Simulation Technique

We present FlameNEST, a framework providing explicit likelihood evaluations in noble element particle detectors using data-driven models from the Noble Element Simulation Technique. FlameNEST provides a way to perform statistical analyses on real data with no dependence on large, computationally expensive Monte Carlo simulations by evaluating the likelihood on an event-by-event basis using analytic probability elements convolved together in a single TensorFlow multiplication. Furthermore, this robust framework creates opportunities for simple inter-collaboration analyses which will be fundamental for the future of experimental dark matter physics.

47 OTHER INSTRUMENTATION↗