Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

At-wavelength characterization of X-ray wavefronts in Bragg diffraction from crystals

The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed. The method was tested at the 1-BM-B optics testing beamline at the Advanced Photon Source for measuring silicon and diamond crystals in a self-referencing single-crystal mode and an absolute double-crystal mode. The phase error sensitivity of the technique is demonstrated to be at the λ/100 level required by most applications, such as the characterization of diamond crystals for cavity-based X-ray free-electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anomalous neutron nuclear-magnetic interference spectroscopy

The electron–phonon interaction plays a critical role in materials’ electrical, thermal, optical, and superconducting properties. However, measuring the phonon mode-resolved electron–phonon interaction has been challenging. Here we propose neutron-scattering-based Anomalous Neutron nUclear-Magnetic Interference Spectroscopy (ANUBIS), where the co-existence of neutron nuclear scattering and magnetic scattering leads to anomalous dynamical structure factor under the presence of the electron–phonon interaction. Such anomalous structure factor is linear in electron–phonon coupling constant at the phonon wavevector, and is directly proportional to the momentum and energy-resolved dielectric function. The experimental configuration can be achieved using existing polarized inelastic neutron scattering setup, and an order-of-magnitude estimate shows the viability to observe the anomalous scattering signal is around to 10 –4 to 10 –3 relative to phonon scattering, which is examined through the preliminary experiments and achievable at emerging neutron facilities. As a result, our proposal offers an alternative neutron-based metrology to probe the crucial electronic properties.

Electron-phonon interactions↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

SPHERES as Formation Flight Algorithm Development and Validation Testbed: Current Progress and Beyond

The MIT-SSL SPHERES testbed provides a facility for the development of algorithms necessary for the success of Distributed Satellite Systems (DSS). The initial development contemplated formation flight and docking control algorithms; SPHERES now supports the study of metrology, control, autonomy, artificial intelligence, and communications algorithms and their effects on DSS projects. To support this wide range of topics, the SPHERES design contemplated the need to support multiple researchers, as echoed from both the hardware and software designs. The SPHERES operational plan further facilitates the development of algorithms by multiple researchers, while the operational locations incrementally increase the ability of the tests to operate in a representative environment. In this paper, an overview of the SPHERES testbed is first presented. The SPHERES testbed serves as a model of the design philosophies that allow for the various researches being carried out on such a facility. The implementation of these philosophies are further highlighted in the three different programs that are currently scheduled for testing onboard the International Space Station (ISS) and three that are proposed for a re-flight mission: Mass Property Identification, Autonomous Rendezvous and Docking, TPF Multiple Spacecraft Formation Flight in the first flight and Precision Optical Pointing, Tethered Formation Flight and Mars Orbit Sample Retrieval for the re-flight mission.

Kong, Edmund M.↗

Fabricating High Resolution Mirrors for Hand X-Ray Astronomy

We describe the fabrication process for producing high-resolution conical mirrors for hard x-ray astronomy. When flown aboard stratospheric balloons, these high-resolution reflective mirrors focus hard x-rays (10-70 keV) emitted from cosmic sources such as supernovae, neutron stars, and quasars onto imaging focal plane detectors. Focused hard x-ray images allow scientists to determine the elemental compositions, temperatures, magnetic fields, velocities, and gravitational fields of these celestial bodies. The fabrication process involves generating super-polished mandrels, mandrel metrology, mirror shell nickel electroforming, and mirror testing. Each mandrel is a cylinder consisting of two conical segments; each segment is approximately 305-mm long. Through precision grinding these mandrels before super polishing, we have achieved 30 arc seconds, half power diameter replicated mirrors. During a May 2001 high atmosphere balloon flight, these mirrors focused high energy x-rays from three different celestial sources. However, we seek to improve the angular resolutions of future mirror shells by a factor of two. To achieve this goal, we have begun single point diamond turning the mandrels before super polishing. This has allowed greater precision tolerances on mandrel surface roughness and axial figure errors before super polishing. Surface roughnesses before polishing have been reduced from approximately 60 nm to approximately 15 nm. The peak to valley axial figure profile errors have been reduced from approximately 1.0 micrometers to approximately 0.4 micrometers. We are currently in Phase 2 of the HERO (high energy replicated optics) program which entails the production of sixteen 6-m-focal-length mirror modules, each containing a nested array of 15 mirror shells of diameters ranging from 50-mm to 94-mm. This flight is slated for the fall of 2003.

Speegle, Chet O.↗

Optoelectronic System Measures Distances to Multiple Targets

An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path length inside the optical fiber is not ordinarily known and can change with temperature, it is also necessary to measure the phase difference associated with this portion and subtract it from the aforementioned overall phase difference to obtain the phase difference proportional to only the free-space path length, which is the distance that one seeks to measure. Therefore, the apparatus includes a photodiode and a circulator that enable measurement of the phase difference associated with propagation from the LRU inside the fiber to the target, reflection from the fiber end, and propagation back inside the fiber to the LRU. Because this phase difference represents twice the optical path length of the fiber, this phase difference is divided in two before subtraction from the aforementioned total-path-length phase difference. Radiation-induced changes in the photodetectors in this apparatus can affect the measurements. To enable calibration for the purpose of compensation for these changes, the apparatus includes an additional target at a known short distance, located inside the camera. If the measured distance to this target changes, then the change is applied to the other targets.

Liebe, Carl Christian↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Science camera calibration for extreme adaptive optics

The nascent field of planet detection has yielded a host of extra-solar planet detections. To date, these detections have been the result of indirect techniques: the planet is inferred by precisely measuring its effect on the host star. Direct observation of extra-solar planets remains a challenging yet compelling goal. In this vein, the Center for Adaptive Optics has proposed a ground-based, high-actuator density extreme A0 system (XAOPI), for a large (~10 m) telescope whose ultimate goal is to directly evidence a specific class of these objects: young and massive planets. Detailed system wave-front error budgets suggest that this system is a feasible, if not an ambitious, proposition. One key element in this error budget is the calibration and maintenance of the science camera wave front with respect to the wave-front sensor which currently as an allowable contribution of ~ 5 nanometers rms. This talk first summarizes the current status of calibration on existing ground-based A0 systems, the magnitude of this effect in the system error budget and current techniques for mitigation. Subsequently, we will explore the nature of this calibration error term, it's source in the non-commonality between the science camera and wave front sensor, and the effect of the temporal evolution of non-commonality. Finally, we will describe preliminary plans for sensing and controlling this error term. The sensing techniques include phase retrieval, phase contrast and external metrology. To conclude, a calibration scenario that meets the stringent requirement for XAOPI will be discussed.

MacIntosh, Bruce↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

The Space Interferometry Mission

The Space Interferometry Mission (SIM) is the next major space mission in NASA's Origins program after SIRTF. The SIM architecture uses three Michelson interferometers in low-earth orbit to provide 4 microarcsecond precision absolute astrometric measurements on approx. 40,000 stars. SIM will also provide synthesis imaging in the visible waveband to a resolution of 10 milliarcsecond, and interferometric nulling to a depth of 10(exp -4). A near-IR (1-2 micron) capability is being considered. Many key technologies will be demonstrated by SIM that will be carried over directly or can be readily scaled to future Origins missions such as TPF. The SIM spacecraft will carry a triple Michelson interferometer with baselines in the 10 meter range. Two interferometers act as high precision trackers, providing attitude information at all time, while the third one conducts the science observations. Ultra-accurate laser metrology and active systems monitor the systematic errors and to control the instrument vibrations in order to reach the 4 microarcsecond level on wide-angle measurements. SIM will produce a wealth of new astronomical data. With an absolute positional precision of 4 microarcsecond, SIM will improve on the best currently available measures (the Hipparcos catalog) by 2 or 3 orders of magnitude, providing parallaxes accurate to 10% and transverse velocities to 0.2 km/s anywhere in the Galaxy, to stars as faint as 20th magnitude. With the addition of radial velocities, knowledge of the 6-dimension phase space for objects of interest will allow us to attack a wide array of previously inaccessible problems such as: search for planets down to few earth masses; calibration of stellar luminosities and by means of standard candles, calibration of the cosmic distance scale; detecting perturbations due to spiral arms, disk warps and central bar in our galaxy; probe of the gravitational potential of the Galaxy, several kiloparsecs out of the galactic plane; synthesis imaging of circumstellar disks around young stellar objects; imaging the narrow-line regions of AGNs in the optical; direct distance determination of a half dozen nearby spiral galaxies using rotational kinematics, thereby sidestepping reddening and metallicity issues in the calibration of distance estimators like Tully-Fisher; imaging exozodiacal dust disks (when operating in its nulling mode, SIM will be sensitive, at a distance of (beta) Pic (20 pc), to scales ranging from 0.2 to 5 AU).

Unwin, Stephen C.↗

Entanglement-enhanced optomechanical sensor array with application to dark matter searches

Abstract Squeezed light has long been used to enhance the precision of a single optomechanical sensor. An emerging set of proposals seeks to use arrays of optomechanical sensors to detect weak distributed forces, for applications ranging from gravity-based subterranean imaging to dark matter searches; however, a detailed investigation into the quantum-enhancement of this approach remains outstanding. Here, we propose an array of entanglement-enhanced optomechanical sensors to improve the broadband sensitivity of distributed force sensing. By coherently operating the optomechanical sensor array and distributing squeezing to entangle the optical fields, the array of sensors has a scaling advantage over independent sensors (i.e., $$\sqrt{M}\to M$$ M → M , where M is the number of sensors) due to coherence as well as joint noise suppression due to multi-partite entanglement. As an illustration, we consider entanglement-enhancement of an optomechanical accelerometer array to search for dark matter, and elucidate the challenge of realizing a quantum advantage in this context.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of warm dense matter by combining static and dynamic compression

Shock-compressing material samples that are precompressed with diamond-anvil cells (DACs) enables benchmarking equation of state measurements over a wide range of high-pressure conditions, in particular, warm dense matter relevant to planetary science, astrophysics, and inertial confinement fusion. These targets provide optical access to the shocked sample, so optical velocity interferometry and pyrometry are typical diagnostics. We present a scaling for the coupling of the laser drive to the shock pressure in DACs based on over 150 prior experiments that can be used to design future experiments. For initial static pressures ≤ 5 GPa, using a sapphire window mitigates the effect of photoionization compared to diamond windows and allows the measurement of shock pressures up to 1 TPa with optical diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal interfaces in dynamic compression experiments

Temperature is a difficult thermodynamic variable to measure in dynamic compression experiments. Optical pyrometry is a general-purpose technique for measuring temperature from a radiant surface, but that surface is often the interface between distinct materials with temperatures that vary spatially along the loading direction. This leads to a fundamental problem: how does the measured interface temperature relate to this temperature profile along the compression axis? Numerical analysis of loading history and thermal diffusion at these interfaces shows that seemingly subtle changes in experiment geometry can lead to very different temperature profiles. We compare these results to laboratory temperature measurements of shock-compressed tin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operando XPS in reactive plasmas: The importance of the wall reactions

In this article, advancements in differential pumping and electron optics over the past few decades have enabled x-ray photoelectron spectroscopy (XPS) measurements at (near-)ambient pressures, bridging the pressure gap for characterizing realistic sample chemistries. Recently, we have demonstrated the capabilities of an ambient pressure XPS setup for in situ plasma environment measurements, allowing plasma-surface interactions to be studied in operando rather than using the traditional before-and-after analysis approach. This new “plasma-XPS” technique facilitates the identification of reaction intermediates critical for understanding plasma-assisted surface processes relevant to semiconductor nanomanufacturing, such as physical vapor deposition, etching, atomic layer deposition, and many other plasma applications. In this paper, we apply the plasma-XPS approach to monitor real-time surface chemical changes on a model Ag(111) single crystal exposed to oxidizing and reducing plasmas. We correlate surface-sensitive data with concurrent gas-phase XPS measurements and residual gas mass-spectrum analysis of species generated during plasma exposure, highlighting the significant role of plasma-induced chamber wall reactions. Ultimately, we demonstrate that plasma-XPS provides comprehensive insights into both surface and gas-phase chemistry, establishing it as a versatile and dynamic characterization tool with broad applications in microelectronics research. Finally, we outline potential enhancements and future metrology directions to advance plasma-XPS investigations further.

36 MATERIALS SCIENCE↗