Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure Loading with In-Situ Permeability Measurement of SiC Ceramic Matrix Composite Tube

Silicon carbide fiber in a silicon carbide matrix composite (SiC-SiC) has been actively researched as a potential structural material to be used in advanced high temperature gas reactors (HTGR) and as an accident tolerant cladding material for light water reactors (LWR). This ceramic composite material demonstrates desirable properties for use in nuclear reactor core that include retention of strength from ambient to LWR and HTGR operating and accident temperatures and stability under neutron radiation. However, the ceramic composite material must be designed to meet all the necessary, application driven requirements before it could be implemented in a reactor design. As one of the requirements for a fuel cladding material, the composite has to maintain high level of impermeability as to retain fission gases throughout the fuel cycle. General Atomics (GA) had previously reported results on permeability levels obtained by CVI produced SiC-SiC composites. It has been determined that for LWR size cladding tube that is 51 mm long the permeability allocation equivalent to currently used claddings is 7.3 E-10 atm*cc/sec. With high level of attention to possible sources of leaks in a test setup, it has been demonstrated that a CVI SiC-SiC composites produced by GA can achieve a leak rate of 1 E-12 atm*cc/sec, and therefore it meets the permeability allocation for a fuel cladding. Further study showed that a particular SiC-SiC composite tube can remain impermeable after being pressure loaded well above LWR normal operating conditions. In the study done by Deck et al., hoop stress was applied to a composite tube using pressure load on the inside surface in a load-unload stepwise sequence with increasing maximum applied stress at each step and measuring permeability between steps. The tested composite comprised of 70% thickness of SiC-SiC composite which provides fracture toughness and bears a majority of the applied stress and a 30% thickness of monolithic SiC layer on the outside surface to provide an impermeable barrier. The composite remained impermeable up to internal pressure of 56 MPa which is more than 2.5 times greater than a typical pressure at the end of life in a fuel rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Efficient, Color-Stable, and Long-Lived White Organic Light-Emitting Diodes Utilizing Phosphorescent Molecular Aggregates

Highly efficient and stable single-stack hybrid white organic light-emitting diode (WOLED) devices are developed using two emissive layers: one with amber-colored phosphorescent molecular-aggregate emission from the Pd(II) complex, Pd(II) 7-(3-(pyridine-2-yl-κN)phenoxy-κC)(benzo-κC)([c]benzo[4,5]imidazo-κN)[1,2-a][1,5]naphthyridine, Pd3O8-Py5, and the other with blue fluorescence emission. Here, an optimized device structure achieves high color stability under various current densities, an external quantum efficiency (EQE) of 45.5%, a power efficiency of 97.4 Lm W -1 , and an estimated LT 95 (operational time to 95% of the initial luminance) of 50 744 h at an initial luminance of 1000 cd m -2 .

36 MATERIALS SCIENCE↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High internal inductance for steady-state operation in ITER and a reactor

Increased confinement and ideal stability limits at relatively high values of the internal inductance (ℓ i ) have enabled an attractive scenario for steady-state tokamak operation to be demonstrated in DIII-D. We achieved normalized plasma pressure in the range appropriate for a reactor in high elongation and triangularity double-null divertor discharges with beta(N) approximate to 5 at ℓ i approximate to 1.3, near the ideal n = 1 kink stability limit calculated without the effect of a stabilizing vacuum vessel wall, with the ideal-wall limit still higher at β N > 5.5. Moreover, confinement is above the H-mode level with H 98(y,H- 2) approximate to 1.8. At q 95 approximate to 7.5, the current is overdriven, with bootstrap current fraction f BS approximate to 0.8, noninductive current fraction f NI > 1 and negative surface voltage. For ITER (which has a single-null divertor shape), operation at ℓ i approximate to 1 is a promising option with f BS approximate to 0.5 and the remaining current driven externally near the axis where the electron cyclotron current drive efficiency is high. This scenario has been tested in the ITER shape in DIII-D at q 95 = 4.8, so far reaching f NI = 0.7 and f BS = 0.4 at beta N approximate to 3.5 with performance appropriate for the ITER Q=5 mission, H 89 beta N /q 2 95 approximate to 0.3. Finally, modeling studies explored how increased current drive power for DIII-D could be applied to maintain a stationary, fully noninductive high ℓ i discharge. Stable solutions in the double-null shape are found without the vacuum vessel wall at beta N = 4, ℓ i = 1.07 and f BS = 0.5, and at beta N = 5 with the vacuum vessel wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A liquid hydrogen target for the MUSE experiment at PSI

A 280 ml liquid hydrogen target has been constructed and tested here for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon–proton and elastic electron–proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This indicates a density stability at the 0.02% level, which is about a factor of ten better than required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Minimum stabilizing energy release for mixing processes

Diffusive operations, which mix the populations of different elements of phase space, can irreversibly transform a given initial state into any of a spectrum of different states from which no further energy can be extracted through diffusive operations. We call these ground states. Here, the lower bound of accessible ground-state energies represents the maximal possible release of energy. This lower bound, sometimes called the diffusively accessible free energy, is of interest in theories of instabilities and wave-particle interactions. On the other hand, the upper bound of accessible ground-state energies has escaped identification as a problem of interest. Yet, as demonstrated here, in the case of a continuous system, it is precisely this upper bound that corresponds to the paradigmatic “quasilinear plateau” ground state of the bump-on-tail distribution. Although for general discrete systems the complexity of calculating the upper bound grows rapidly with the number of states, using techniques adapted from treatments of the lower bound, the upper bound can in fact be computed directly for the three-state discrete system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Benchmarked Kinetic Resistive Wall Mode Stability Codes to ITER, Including Additional Physics

Leading resistive wall mode (RWM) stability codes MARS-K [Y. Liu, et al., Phys. Plasmas 15, 112503 (2008)] and MISK [B. Hu, et al., Phys. Plasmas 12, 057301 (2005)] have been previously benchmarked. The benchmarking has now been extended to include additional physics, and used to project the stability of ITER in a realistic operating space. Due to ITER's relatively low plasma rotation and collisionality, collisions and non-resonance rotational effects were both found to have little impact on stability, and these non-resonance rotational effects also will not self-consistently affect the ITER RWM eigenfunction. Resonances between thermal ions and electrons and the expected level of ITER toroidal rotation were found to be important to stability, as were alpha particles, which are not in rotational resonance. MISK calculations show that without alpha particles, ITER is projected to be unstable to the RWM, but the expected level of alphas is calculated to provide a sufficient level of stability.

Resistive Wall Mode Stability↗

Noise-Resilient Quantum Machine Learning for Stability Assessment of Power Systems

Transient stability assessment (TSA) is a cornerstone for resilient operations of todays interconnected power grids. This paper is a confluence of quantum computing, data science and machine learning to potentially address the power system TSA issue. Here, we devise a quantum TSA (QTSA) method to enable scalable and efficient data-driven transient stability prediction for bulk power systems, which is the first attempt to tackle the TSA issue with quantum computing. Our contributions are three-fold: 1) A high expressibility, low-depth (HELD) quantum circuit is designed for accurate and noise-resilient TSA; 2) A quantum natural gradient descent algorithm is developed for efficient HELD circuit training; 3) A systematical analysis on QTSAs performance under various quantum factors is per-formed. QTSA underpins a foundation of quantum-enabled and data-driven power grid stability analytics. It renders the intractable TSA straightforward and effortless in the Hilbert space, and therefore provides stability information for power system operations. Extensive experiments on quantum simulators and real quantum computers verify the accuracy, noise-resilience, scalability and universality of QTSA.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Energy Aqueous Lithium-Ion Batteries (Final Report)

Lithium-ion batteries (LIBs) are a widely used energy storage device. For decades, researchers have been studying aqueous electrolytes due to their non-flammability and environmental friendless. However, the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) of water greatly limit the voltage window of the aqueous electrolyte. The recent concept of ‘solvent-in-salt’ electrolytes, namely ‘water-in-salt’ electrolytes (WISE) for aqueous batteries and ‘super-concentrated’ electrolytes for non-aqueous batteries, greatly expands the electrochemical window of these battery systems and consequently their energy density. This expansion occurs because the large number of salt aggregates in ‘solvent-in-salt’ electrolytes enables preferential salt decomposition over solvent decomposition to form robust interphase layers on electrodes, thus enhancing their stability in a wide range of operating voltages. However, even when the salt concentration reached 63m, regardless of cost, the cathodic potential of the WISE expanded only to 1.75V with an overall electrochemical stability window of <3.25V. To design the next generation of high energy aqueous LIBs, electrolytes that possess a wider electrochemical stability window and lower cost but still maintain the merit of non-flammability are much needed. In this project, we designed the aqueous LIBs with widened voltage window. We reported a cheap and non-flammable ternary eutectic electrolyte that can form a robust solid electrolyte interface (SEI)so that the cathodic limiting potential can be decreased to <1.5 V for Li 4 Ti 5 O 12 anodes, while maintaining both a high ionic conductivity of >10 -3 S cm –1 and a low viscosity. We demonstrated the super-stable2.5V LiMn 2 O 4 ||Li 4 Ti 5 O 12 pouch cell with mass loading of 2.5 mAh/cm. Further, LiCl-LiBr-Graphite/Li full cells were designed with high energy density. Finally, we use a bi-layer design to enlarge the voltage window of aqueous electrolyte, which can endow the stable cycling of aqueous Lithium metal batteries.

25 ENERGY STORAGE↗

The Impact of Different Substituents in Fluorinated Cyclic Carbonates in the Performance of High Voltage Lithium-Ion Battery Electrolyte

Ethylene carbonate (EC) has been used as the Solid-Electrolyte Interphase (SEI) former in the conventional electrolyte for decades. However, its low anodic stability leads to severe capacity decay during cycling under high voltage operation. Therefore, finding a viable electrolyte with high anodic stability and the ability to form robust SEI for high voltage lithium-ion batteries is of primary importance. In this study, a series of electrolytes containing various fluorinated cyclic carbonates as the SEI former have been designed, synthesized and evaluated. Linear sweep voltammetry study suggested that fluorinated cyclic carbonates generally possess higher anodic stability than EC. Based on the cycling performance of LiNi 0.5 Co 0.2 Mn 0.3 O 2 (NMC532)/ graphite full cells, the electrolyte with DFEC/FEMC (1.0 M LiPF 6 ) inhibited the oxidation side reaction on the cathode and forms a vigorous SEI on the anode. The high voltage NMC532/Graphite cell utilizing the novel electrolyte exhibits excellent cycling durability under both room and elevated temperature. The superior performance of the DFEC based electrolyte was further unveiled by SEM, EDAX and XRD. Both the anode and cathode of the full cell employing DFEC based electrolyte retained their intrinsic structures after cycling while the electrodes cycled in conventional electrolyte showed severe degradation.

25 ENERGY STORAGE↗

Extending Lean and Exhaust Gas Recirculation-Dilute Operating Limits of a Modern Gasoline Direct-Injection Engine Using a Low-Energy Transient Plasma Ignition System

The efficiency improvement and emissions reduction potential of lean and exhaust gas recirculation (EGR)-dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nanosecond pulses and its performance compared to a conventional transistorized coil ignition (TCI) system operated on an automotive, gasoline direct-injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar indicated mean effective pressure (IMEP), where dilution tolerance is particularly critical to improving efficiency and emission performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ = 1.55 to 1.7) with the low-energy transient plasma ignition system.

33 ADVANCED PROPULSION SYSTEMS↗

EXTENDING LEAN AND EGR-DILUTE OPERATING LIMITS OF A MODERN GDI ENGINE USING A LOW-ENERGY TRANSIENT PLASMA IGNITION SYSTEM

The efficiency improvement and emissions reduction potential of lean and EGR dilute operation of spark-ignition gasoline engines is well understood and documented. However, dilute operation is generally limited by deteriorating combustion stability with increasing inert gas levels. The combustion stability decreases due to reduced mixture flame speeds resulting in significantly increased combustion initiation periods and burn durations. A study was designed and executed to evaluate the potential to extend lean and EGR-dilute limits using a low-energy transient plasma ignition system. The low-energy transient plasma was generated by nano-second pulses and its performance compared to a conventional transistorized coil ignition system operated on an automotive, gasoline direct injection (GDI) single-cylinder research engine. The experimental assessment was focused on steady-state experiments at the part load condition of 1500 rpm 5.6 bar IMEP, where dilution tolerance is particularly critical to improving efficiency and emissions performance. Experimental results suggest that the energy delivery process of the low-energy transient plasma ignition system significantly improves part load dilution tolerance by reducing the early flame development period. Statistical analysis of relevant combustion metrics was performed in order to further investigate the effects of the advanced ignition system on combustion stability. Results confirm that at select operating conditions EGR tolerance and lean limit could be improved by as much as 20% (from 22.7 to 27.1% EGR) and nearly 10% (from λ=1.55 to 1.7) with the low-energy transient plasma ignition system.

Sevik, James Michael↗

Performance and long-term stability of CO 2 conversion to formic acid using a three-compartment electrolyzer design

The electrochemical reduction of CO 2 to formate and formic acid has attracted a great amount of academic and commercial interest over the past five years. A number of experimental studies have generated data on the Faradaic performance and stability of various candidate catalyst materials in producing formate or formic acid. However, most of the data has been conducted at low current densities and over short time periods, typically hours to days. There is a critical need in providing long-term catalyst stability as well as electrolyzer-based operating data, which are needed for the commercial scale-up and operation of this technology, especially at high current densities. In this paper, the electrochemical CO 2 conversion to pure formic acid was conducted using a three-compartment design electrolyzer, demonstrating electrolyzer catalyst and performance stability for over 1000 h at current densities up to 200 mA cm -2 . Depending on the operation conditions, the electrolyzer directly produced a 6.03 to 12.92 wt% (1.3 to 2.8 M) formic acid product at Faradaic efficiencies ranging between 73.0 to 91.3%. Data on electrolyzer performance, including formic acid product generation rate, energy efficiency, and energy consumption are reported at three different current densities, 100, 200, and 250 mA cm -2 . Finally, a long term 1000 h electrolyzer stability run at 200 mA cm -2 is presented, providing information on the operating conditions required in obtaining stable electrolyzer performance. All the data will be extremely useful in the commercial scale-up of this technology.

10 SYNTHETIC FUELS↗

Projected global stability of high beta MAST-U spherical tokamak plasmas

Assessment of the limits of stability of tokamak plasmas is essential to operation in high fusion performance ranges without disruption of the plasma current. Projected equilibria have been generated for the MAST-U spherical tokamak experiment, an upgrade of the previous MAST device, in order to prepare for operation. These equilibria are scanned in pressure and current profiles, and assessed with the DCON and MARS-F stability codes to find the so-called 'no-wall' beta limit, above which resistive wall mode instabilities can be expected in the absence of other stabilising effects. The no-wall limit was generally found to increase as plasma internal inductance increased. The equilibria are also assessed for the 'with-wall' limit, theoretically the highest achievable performance point, again with the DCON and MARS-F codes, including different approximate axisymmetric walls, and with the VALEN code which includes a 3D model of the surrounding conducting structure. Similar limits were found, despite the difference between the 2D and 3D codes in the treatment of the wall. Conducting passive stabilisation plates, which were newly installed in MAST-U, are in a region of significant mode perturbation when the plasma β N is sufficiently high and eddy currents are driven in these structures. Due to the increased stabilising effect of the wall in MAST-U vs. MAST, a significant gap exists between the approximate no-wall limits of β N / l i = 6.71 and 7.13, found from DCON and MARS-F respectively, and the with-wall limits of β N / l i = 8.23 and 8.53 for the equilibrium profiles analysed in this study. This opens a region of high beta operating space in MAST-U for potentially stable operation if non-ideal effects or active control can stabilise the resistive wall mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How Fisheries Biologists Can Facilitate the Clean Energy Transition

Abstract Fisheries and aquatic biologists play a critical role in creating environmentally protective hydropower flow requirements that govern flow timing, frequency, magnitude, and rate of change. Hydropower's role in the U.S. electrical grid is expected to evolve in response to increased wind and solar generation as hydropower will be called upon to quickly ramp up and down in response to changes in wind and solar generation. For this reason, hydropower is expected to have increased value as fossil generation is phased out, even as rapid flow fluctuations linked with hydropower flexibility may strand fish, alter habitat, and create unsafe recreational conditions. We face a new challenge in facilitating the renewable energy transition—designing environmental flow requirements that protect against the impacts of flow fluctuations while allowing adequate hydropower flexibility to support a stable grid. In this paper, we discuss hydropower environmental flow requirements, operational flexibility, and electrical grid stability, their potential interactions, and opportunities to align environmental and power system needs to support healthy ecosystems, multiple water uses, and decarbonization of the electric grid.

13 HYDRO ENERGY↗

Degradation of solid oxide electrolysis cells: Phenomena, mechanisms, and emerging mitigation strategies—A review

Solid oxide electrolysis cell (SOEC) is a promising electrochemical device with high efficiency for energy storage and conversion. However, the degradation of SOEC is a significant barrier to commercial viability. In this review article, the typical degradation phenomena of SOEC are summarized, with great attention into the anodes/oxygen electrodes, including the commonly used and newly developed anode materials. Meanwhile, mechanistic investigations on the electrode/electrolyte interfaces are provided to unveil how the intrinsic factor, oxygen partial pressure , and the electrochemical operation conditions, affect the interfacial stability of SOEC. At last, this paper also presents some emerging mitigation strategies to circumvent long-term degradation, which include novel infiltration method, development of new anode materials and engineering of the microstructure.

36 MATERIALS SCIENCE↗