Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Effect of Urban Heat Island and Global Warming Countermeasures on Heat Release and Carbon Dioxide Emissions from a Detached House

Urban air temperature rises induced by the urban heat island (UHIE) effect or by global warming (GW) can be beneficial in winter but detrimental in summer. The SCIENCE-Outdoor model was used to simulate changes to sensible heat release and CO 2 emissions from buildings yielded by four UHIE countermeasures and five GW countermeasures. This model can evaluate the thermal condition of building envelope surfaces, both inside and outside. The results showed that water-consuming UHIE countermeasures such as evaporative space cooling and roof water showering provided positive effects (decreasing sensible heat release and CO 2 emissions related to space conditioning) in summer. Additionally, they had no negative (unwanted cooling) effects in winter since they can be turned off in the heating season. Roof greening can provide the greatest space- conditioning CO 2 emissions reductions among four UHIE countermeasures, and it reduces the amount of heat release slightly in the heating season. Since the effect on reducing carbon dioxide (CO 2 ) emissions by UHIE countermeasures is not very significant, it is desirable to introduce GW countermeasures in order to reduce CO 2 emissions. The significance of this study is that it constructed the new simulation model SCIENCE-Outdoor and applied it to show the influence of countermeasures upon both heat release and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Impact of Solid State Roadway Lighting on Melatonin in Humans

Introduction: In 2009, the World Health Organization identified vehicle crashes, both injury-related and fatal, as a public health hazard. Roadway lighting has long been used to reduce crashes and improve the safety of all road users. Ocular light exposure at night can suppress melatonin levels in humans. At sufficient light levels, all visible light wavelengths can elicit this response, but melatonin suppression is maximally sensitive to visible short wavelength light. With the conversion of roadway lighting to solid state sources that have a greater short wavelength spectrum than traditional sources, there is a potential negative health impact through suppressed melatonin levels to roadway users and those living close to the roadway. This paper presents data on the impact of outdoor roadway lighting on salivary melatonin in three cohorts of participants: drivers, pedestrians, and those experiencing light trespass in their homes. Methods: In an outdoor naturalistic roadway environment, healthy participants (N = 29) each being assigned to a cohort of either pedestrian, driver, or light trespass experiment, were exposed to five different solid state light sources with differing spectral emissions and one no lighting condition. Salivary melatonin measurements were made under an average roadway luminance of 1.0 cd/m2 (IES RP-18 Roadway Lighting Requirements for expressway roads) with a corneal melanopic Equivalent Daylight Illuminances (EDI) ranging from 0.22 to 0.86 lux. Results: The results indicate that compared to the no roadway lighting condition, the roadway light source spectral content did not significantly impact salivary melatonin levels in the participants in any of the cohorts. Conclusions: These data show that recommended levels of street lighting for expressway roads do not elicit an acute suppression of salivary melatonin and suggest that the health benefit of roadway lighting for traffic safety is not compromised by an acute effect on salivary melatonin.

60 APPLIED LIFE SCIENCES↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A New Black Carbon Sensor for Dense Air Quality Monitoring Networks

Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)—a major component of particulate matter pollution associated with adverse human health risks—is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD’s sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval).

47 OTHER INSTRUMENTATION↗

Radiological Scouting, Monitoring and Inspection Using Drones

Human populations and natural ecosystems are bound to be exposed to ionizing radiation from the deposition of artificial radionuclides resulting from nuclear accidents, nuclear devices or radiological dispersive devices (“dirty bombs”). On the other hand, Naturally Occurring Radioactive Material industries such as phosphate production or uranium mining, contribute to the on site storage of residuals with enhanced concentrations of natural radionuclides. Therefore, in the context of the European agreements concerning nuclear energy, namely the European Atomic Energy Community Treaty, monitoring is an essential feature of the environmental radiological surveillance. In this work, we obtain 3D maps from outdoor scenarios, and complete such maps with measured radiation levels and with its radionuclide signature. In such scenarios, we face challenges such as unknown and rough terrain, limited number of sampled locations and the need for different sensors and therefore different tasks. We propose a radiological solution for scouting, monitoring and inspecting an area of interest, using a fleet of drones and a controlling ground station. First, we scout an area with a Light Detection and Ranging sensor onboard a drone to accurately 3D-map the area. Then, we monitor that area with a Geiger–Müller Counter at a low-vertical distance from the ground to produce a radiological (heat)map that is overlaid on the 3D map of the scenario. Next, we identify the hotspots of radiation, and inspect them in detail using a drone by landing on them, to reveal its radionuclide signature using a Cadmium–Zinc–Telluride detector. We present the algorithms used to implement such tasks both at the ground station and on the drones. The three mission phases were validated using actual experiments in three different outdoor scenarios. We conclude that drones can not only perform the mission efficiently, but in general they are faster and as reliable as personnel on the ground.

Pinto, Luís Ramos (ORCID:0000000319975484)↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Cold Weather

When operated, the climate control system is the largest auxiliary load on a vehicle. This load has significant impact on fuel economy for conventional and hybrid vehicles, and it drastically reduces the driving range of all electric vehicles (EVs). Heating is even more detrimental to EV range than cooling because no engine waste heat is available. Reducing the thermal loads on the heating, ventilating, and air conditioning system will extend driving range and increase the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have evaluated strategies for vehicle climate control load reduction with special attention toward grid connected electric vehicles. Outdoor vehicle thermal testing and computational modeling were used to assess potential strategies for improved thermal management and to evaluate the effectiveness of thermal load reduction technologies. A human physiology model was also used to evaluate the impact on occupant thermal comfort. Experimental evaluations of zonal heating strategies demonstrated a 5.5% to 28.5% reduction in cabin heating energy over a 20-minute warm-up. Vehicle simulations over various drive cycles show a 6.9% to 18.7% improvement in EV range over baseline heating using the most promising zonal heating strategy investigated. A national-level analysis was conducted to determine the overall national impact. If all vehicles used the best zonal strategy, the range would be improved by 7.1% over the baseline heating range. This is a 33% reduction in the range penalty for heating.

30 DIRECT ENERGY CONVERSION↗

A forward speed effects study on jet noise from several suppressor nozzles in the NASA/Ames 40- by 80-foot wind tunnel

A test program was conducted in a 40 by 80 foot wind tunnel to evaluate the effect of relative velocity on the jet noise signature of a conical ejector, auxiliary inlet ejector, 32 spokes and 104 tube nozzle with and without an acoustically treated shroud. The freestream velocities in the wind tunnel were varied from 0 to 103.6 m/sec (300 ft/sec) for exhaust jet velocities of 259.1 m/sec (850 ft/sec) to 609.6 m/sec (2000 ft/sec). Reverberation corrections for the wind tunnel were developed and the procedure is explained. In conjunction with wind tunnel testing the nozzles were also evaluated on an outdoor test stand. The wind tunnel microphone arrays were duplicated during the outdoor testing. The data were then extrapolated for comparisons with data measured using a microphone array placed on a 30.5 meter (100 ft) arc. Using these data as a basis, farfield to nearfield arguments are presented with regards to the data measured in the wind tunnel. Finally, comparisons are presented between predictions made using existing methods and the measured data.

Beulke, M. R.↗

A generalized correlation of experimental flat-plate collector performance

A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

Simon, F. F.↗

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.↗

Judgements of relative noisiness of a supersonic transport and several commercial-service aircraft

Two laboratory experiments were conducted on the relative noisiness of takeoff and landing operations of a supersonic transport and several other aircraft in current commercial service. A total of 96 subjects made noisiness judgments on 120 tape-recorded flyover noises in the outdoor-acoustic-simulation experiment; 32 different subjects made judgments on the noises in the indoor-acoustic-simulation experiment. The judgments were made by using the method of numerical category scaling. The effective perceived noise level underestimated the noisiness of the supersonic transport by 3.5 db. For takeoff operations, no difference was found between the noisiness of the supersonic transport and the group of other aircraft for the A-weighted rating scale; however, for landing operations, the noisiness of the supersonic transport was overestimated by 3.7 db. Very high correlation was found between the outdoor-simulation experiment and the indoor-simulation experiment.

Powell, C. A.↗

Verification test of the MSFC solar simulator using a Honeywell double-covered liquid solar collector

Additional verification data to support the utilization of the MSFC Solar Simulator for testing solar collectors was obtained. The Honeywell double-covered liquid solar collector number 2 for which thermal performance data under natural outdoor conditions had been previously obtained was installed on the Solar Simulator and subjected to a series of eight tests under various conditions of wind flow rate. Although these test conditions were not absolutely identical to those of the outdoor tests, they are considered to be sufficiently representative to provide a basis for an accurate comparative analysis of the data recorded for both test programs.

Shih, K., Sr.↗

Thermal performance of MSFC hot air collectors under natural and simulated conditions

The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.

Shih, K., Sr.↗

Endurance testing of first generation (Block 1) commercial solar cell modules

To determine lifetimes of the first generation (Block 1) commercial solar cell modules used in solar cell arrays, a program was initiated to expose these modules to a range of environments. The conditions endured by these modules encompassed hot and dry, hot and humid, tropical rain forests, sea-air, urban industrial and urban clean. Exposures were for periods up to 1 year. The effect of outdoor exposure on the performance of the modules was determined using current-voltage curves. Short-circuit current (I sub sc) and maximum power (P sub max) were the parameters monitored. In all cases, there was a loss of performance of the modules with outdoor exposure.

Anagnostou, E.↗

A mobile apparatus for solar collector testing

The design, construction, and operation of a mobile apparatus for solar collector testing (MASCOT) is described. The MASCOT is a self-contained test unit costing about $10,000 whose only external requirement for operation is electrical power and which is capable of testing two water-cooled flat-plate solar collectors simultaneously. The MASCOT is small enough and light enough to be transported to any geographical site for outdoor tests at the location of collector usage. It has been used in both indoor solar simulator tests and outdoor tests.

Hotchkiss, G. B.↗

Large-scale fiber release and equipment exposure experiments

Outdoor tests were conducted to determine the amount of fiber released in a full scale fire and trace its dissemination away from the fire. Equipment vulnerability to fire released fibers was assessed through shock tests. The greatest fiber release was observed in the shock tube where the composite was burned with a continuous agitation to total consumption. The largest average fiber length obtained outdoors was 5 mm.

Pride, R. A.↗

Analytical study of the effects of wind tunnel turbulence on turbofan rotor noise

The influence of tunnel turbulence on turbofan rotor noise was carried out to evaluate the effectiveness of the NASA Ames 40 by 80 foot tunnel in simulating flight levels of fan noise. A previously developed theory for predicting rotor/turbulence interaction noise was refined and extended to include first-order effects of inlet turbulence anisotropy. This theory was then verified by carrying out extensive data/theory comparisons. The resulting model computer program was then employed to carry out a parametric study of the effects of fan size, blade number, and operating line on rotor/turbulence noise for outdoor test stand. NASA Ames wind tunnel, and flight inlet turbulence conditions. A major result of this study is that although wind tunnel rotor/turbulence noise levels are not as low as flight levels they are substantially lower than the outdoor test stand levels and do not mask other sources of fan noise.

Gliebe, P. R.↗

Analytical study of the effects of wind tunnel turbulence on turbofan rotor noise

An analytical study of the effects of wind tunnel turbulence on turbofan rotor noise was carried out to evaluate the effectiveness of the NASA Ames 40 by 80-foot wind tunnel in simulating flight levels of fan noise. A previously developed theory for predicting rotor/turbulence interaction noise, refined and extended to include first-order effects of inlet turbulence anisotropy, was employed to carry out a parametric study of the effects of fan size, blade number, and operating line for outdoor test stand, NASA Ames wind tunnel, and flight inlet turbulence conditions. A major result of this study is that although wind tunnel rotor/turbulence noise levels are not as low as flight levels, they are substantially lower than the outdoor test stand levels and do not mask other sources of fan noise.

Gliebe, P. R.↗