Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Investigation of scrubbing and impingement noise

Tests were conducted in an acoustic wind tunnel to determine surface pressure spectra and far field noise caused by turbulence impinging on an airfoil and turbulence convected past a sharp trailing edge. Measured effects of flow velocity and turbulence intensity were compared with predictions from several theories. Also, tests were conducted in an anechoic chamber to determine surface pressure spectra and far field noise caused by a deflected airfoil scrubbed by a subsonic jet. This installation simulated both an under-the-wing and an upper-surface-blowing externally blown flap, depending on the deflection angle. Surface and far field spectra, and cross correlation coherence and delay time, were utilized to infer the major noise-producing mechanisms.

Fink, M. R.↗

Acoustic radiation and surface pressure characteristics of an airfoil due to incident turbulence

A theoretical and experimental investigation of the noise and unsteady surface pressure characteristics of an isolated airfoil in a uniform mean velocity, homogeneous, nearly-isotropic turbulence field was conducted. Wind tunnel experiments were performed with a 23 cm chord, two dimensional NACA 0012 airfoil over a free stream Mach number range of 0.1 to 0.5. Far-field noise spectra and directivity were measured in an anechoic chamber that surrounded the tunnel open jet test section. Spanwise and chordwise distribution of unsteady airfoil surface pressure spectra and surface pressure cross-spectra were obtained. Incident turbulence intensities, length scales, spectra, and spanwise cross-spectra, required in the calculation of far-field noise and surface pressure characteristics were also measured.

Paterson, R. W.↗

Line shape parameters of PH 3 transitions in the Pentad near 4–5 μm: Self-broadened widths, shifts, line mixing and speed dependence

Accurate knowledge of spectroscopic line parameters of PH 3 is important for remote sensing of the outer planets, especially Jupiter and Saturn. In a recent study, line positions and intensities for the Pentad bands of PH 3 have been reported from analysis of high-resolution, high signal-to noise room-temperature spectra recorded with two Fourier transform spectrometers (2014) [1]. The results presented in this study were obtained during the analysis of positions and intensities, but here we focus on the measurements of spectral line shapes (e.g. widths, shifts, line mixing) for the 2ν 4 , ν 2 + ν 4 , ν 1 and ν 3 bands. A multispectrum nonlinear least squares curve fitting technique employing a non-Voigt line shape to include line mixing and speed dependence of the Lorentz width was employed to fit the spectra simultaneously. The least squares fittings were performed on five room-temperature spectra recorded at various PH 3 pressures (~2–50 Torr) with the Bruker IFS-125HR Fourier transform spectrometer (FTS) located at the Pacific Northwest National Laboratory (PNNL), in Richland, Washington. Over 840 Lorentz self-broadened half-width coefficients, 620 self-shift coefficients and 185 speed dependence parameters were measured. Line mixing was detected for transitions in the 2ν 4 , ν 1 and ν 3 bands, and their values were quantified for 10 A+A- pairs of transitions via off-diagonal relaxation matrix element formalism. The dependences of the measured half-width coefficients on the J and K rotational quanta of the transitions are discussed. The self-width coefficients for the ν 1 and ν 3 bands from this study are compared to the self-width coefficients for transitions with the same rotational quanta (J, K) reported for the Dyad (ν 2 and ν 4 ) bands. The measurements from present study should be useful for the development of a reliable theoretical modeling of pressure-broadened widths, shifts and line mixing in symmetric top molecules with C 3v symmetry in general, and of PH 3 in particular.

Malathy Devi, V.↗

Optical re-injection in cavity-enhanced absorption spectroscopy

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

Volumetric Data Exploration with Machine Learning-Aided Visualization in Neutron Science

Recent advancements in neutron and X-ray sources, instrumentation and data collection modes have significantly increased the experimental data size (which could easily contain 108–1010 data points), so that conventional volumetric visualization approaches become inefficient for both still imaging and interactive OpenGL rendition in a 3D setting. We introduce a new approach based on the unsupervised machine learning algorithm, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), to efficiently analyze and visualize large volumetric datasets. Here we present two examples of analyzing and visualizing datasets from the diffuse scattering experiment of a single crystal sample and the tomographic reconstruction of a neutron scanning of a turbine blade. We found that by using the intensity as the weighting factor in the clustering process, DBSCAN becomes very effective in de-noising and feature/boundary detection, and thus enables better visualization of the hierarchical internal structures of the neutron scattering data.

Hui, Yawei↗

A multi-dimensional, moment-accelerated deterministic particle method for time-dependent, multi-frequency thermal radiative transfer problems

Thermal Radiative Transfer (TRT) is the dominant energy transfer mechanism in high-energy density physics with applications in inertial confinement fusion and astrophysics. The stiff interactions between the material and radiation fields make TRT problems challenging to model. In this study, we propose a multi-dimensional extension of the deterministic particle (DP) method. The DP method combines aspects from both particle and deterministic methods. If the emission source is known a priori, and no physical scattering is present, the intensity of a particle can be integrated analytically. This introduces no statistical noise compared to Monte-Carlo methods, while maintaining the flexibility of particle methods. The method is closely related to the popular method of long characteristics. The combination of the DP-method with a discretely-consistent, nonlinear, gray low-order system enables an efficient solution algorithm for multi-frequency TRT problems. Here, we demonstrate with numerical examples that the use of a linear-source approximation based on spatial moments improves the behavior of our method in the thick diffusion limit significantly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Almost perfect in-phase and anti-phase chaotic and periodic phase synchronization in large arrays of diode lasers

In this paper we study phase synchronization in large arrays of weakly coupled single mode semiconductor laser diodes. We show that if the coupling topology is chosen appropriately, the laser array exhibits robust phase synchrony (including chaotic and non-chaotic phase synchrony). Furthermore, one can define coupling topologies that lead to chaotic anti-phase synchronization. To the best of our knowledge, chaotic anti-phase synchronization has not been observed in large arrays of coupled nonlinear oscillators. Additionally, when diodes are coupled via a decayed non-local coupling scheme, the leading spatial mode can be stable. This leads to an almost-perfect phase synchronous state where the phases are synchronized, but the system is not set exactly on the synchronization manifold. This almost-perfect phase synchronous state is robust to noise and frequency disorder and can be realized under periodic (fixed-intensity limit cycle) continuous-wave and chaotic behavior. The presented result is an example of the broader phenomenon of linear transverse mode selection taking place in a coupled oscillator system with nonlinear dynamics.

47 OTHER INSTRUMENTATION↗

All-optical image denoising using a diffractive visual processor

Abstract Image denoising, one of the essential inverse problems, targets to remove noise/artifacts from input images. In general, digital image denoising algorithms, executed on computers, present latency due to several iterations implemented in, e.g., graphics processing units (GPUs). While deep learning-enabled methods can operate non-iteratively, they also introduce latency and impose a significant computational burden, leading to increased power consumption. Here, we introduce an analog diffractive image denoiser to all-optically and non-iteratively clean various forms of noise and artifacts from input images – implemented at the speed of light propagation within a thin diffractive visual processor that axially spans <250 × λ, where λ is the wavelength of light. This all-optical image denoiser comprises passive transmissive layers optimized using deep learning to physically scatter the optical modes that represent various noise features, causing them to miss the output image Field-of-View (FoV) while retaining the object features of interest. Our results show that these diffractive denoisers can efficiently remove salt and pepper noise and image rendering-related spatial artifacts from input phase or intensity images while achieving an output power efficiency of ~30–40%. We experimentally demonstrated the effectiveness of this analog denoiser architecture using a 3D-printed diffractive visual processor operating at the terahertz spectrum. Owing to their speed, power-efficiency, and minimal computational overhead, all-optical diffractive denoisers can be transformative for various image display and projection systems, including, e.g., holographic displays.

36 MATERIALS SCIENCE↗

Probing the subcellular nanostructure of engineered human cardiomyocytes in 3D tissue

Abstract The structural and functional maturation of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is essential for pharmaceutical testing, disease modeling, and ultimately therapeutic use. Multicellular 3D-tissue platforms have improved the functional maturation of hiPSC-CMs, but probing cardiac contractile properties in a 3D environment remains challenging, especially at depth and in live tissues. Using small-angle X-ray scattering (SAXS) imaging, we show that hiPSC-CMs matured and examined in a 3D environment exhibit a periodic spatial arrangement of the myofilament lattice, which has not been previously detected in hiPSC-CMs. The contractile force is found to correlate with both the scattering intensity ( R 2 = 0.44) and lattice spacing ( R 2 = 0.46). The scattering intensity also correlates with lattice spacing ( R 2 = 0.81), suggestive of lower noise in our structural measurement than in the functional measurement. Notably, we observed decreased myofilament ordering in tissues with a myofilament mutation known to lead to hypertrophic cardiomyopathy (HCM). Our results highlight the progress of human cardiac tissue engineering and enable unprecedented study of structural maturation in hiPSC-CMs.

36 MATERIALS SCIENCE↗

Emission features and expansion dynamics of nanosecond laser ablation plumes at different ambient pressures

The influence of ambient pressure on the spectral emission features and expansion dynamics of a plasma plume generated on a metal target has been investigated. The plasma plumes were generated by irradiating Cu targets using 6 ns, 1064 nm pulses from a Q-switched Nd:YAG laser. The emission and expansion dynamics of the plasma plumes were studied by varying air ambient pressure levels ranging from vacuum to atmospheric pressure. The ambient pressure levels were found to affect both the line intensities and broadening along with the signal to background and signal to noise ratios and the optimum pressure conditions for analytical applications were evaluated. The characteristic plume parameters were estimated using emission spectroscopy means and noticed that the excitation temperature peaked ∼300 Torr, while the electron density showed a maximum ∼100 Torr. Fast-gated images showed a complex interaction between the plume and background air leading to changes in the plume geometry with pressure as well as time. Surface morphology of irradiated surface showed that the pressure of the ambient gas affects the laser-target coupling significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Studies of Compensation of Beam-Beam Effects with Tevatron Electron Lenses

Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the results of various beam experiments with 'electron lenses', novel instruments developed for the beam-beam compensation at the Tevatron, which collides 980-GeV proton and antiproton beams. We study the dependencies of the particle betatron tunes on the electron beam current, energy and position; we explore the effects of electron-beam imperfections and noises; and we quantify the improvements of the high-energy beam intensity and the collider luminosity lifetime obtained by the action of the Tevatron Electron Lenses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DISCOVERY OF FINELY STRUCTURED DYNAMIC SOLAR CORONA OBSERVED IN THE Hi-C TELESCOPE

In the Summer of 2012, the High-resolution Coronal Imager (Hi-C) flew on board a NASA sounding rocket and collected the highest spatial resolution images ever obtained of the solar corona. One of the goals of the Hi-C flight was to characterize the substructure of the solar corona. We therefore examine how the intensity scales from AIA resolution to Hi-C resolution. For each low-resolution pixel, we calculate the standard deviation in the contributing high-resolution pixel intensities and compare that to the expected standard deviation calculated from the noise. If these numbers are approximately equal, the corona can be assumed to be smoothly varying, i.e., have no evidence of substructure in the Hi-C image to within Hi-C's ability to measure it given its throughput and readout noise. A standard deviation much larger than the noise value indicates the presence of substructure. We calculate these values for each low-resolution pixel for each frame of the Hi-C data. On average, 70% of the pixels in each Hi-C image show no evidence of substructure. The locations where substructure is prevalent is in the moss regions and in regions of sheared magnetic field. We also find that the level of substructure varies significantly over the roughly 160 s of the Hi-C data analyzed here. This result indicates that the finely structured corona is concentrated in regions of heating and is highly time dependent.

79 ASTRONOMY AND ASTROPHYSICS↗

Multifrequency Raman amplifiers

In its usual implementation, the Raman amplifier features only one pump carrier frequency. However, pulses with well-separated frequencies can also be Raman amplified while compressed in time. Amplification with frequency-separated pumps is shown to hold even in the highly nonlinear, pump-depletion regime, as derived through a fluid model, and demonstrated via particle-in-cell (PIC) simulations. The resulting efficiency is similar to single-frequency amplifiers, but, due to the beat-wave waveform of both the pump lasers and the amplified seed pulses, these amplifiers feature higher seed intensities with a shorter spike duration. Advantageously, these amplifiers also suffer less noise backscattering, because the total fluence is split between the different spectral components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propagation in a shearing plasma. II - Turbulence and the frequency range of pulsar microstructure

Numerical calculations are presented which explore the propagation of radio waves and pulses through a turbulent shearing plasma. A stochastic model is used to describe the turbulent velocity field, in which random fluctuations are superposed on a mean profile. Both Gaussian wave packets and shot-noise pulses polarized in the plane of shearing acquire quasi-periodic intensity modulations above the rest-frame plasma frequency. The frequency range over which these modulations appear is shown to depend on the spatial correlation length of the turbulent fluctuations and on their standard deviation from the mean velocity. The period of the modulations is variable from one realization of the random process to the next, and the average period is frequency dependent. The results of these calculations lend further support to a model for pulsar microstructure in which periodic micropulses are pure temporal modulations of the emitted radiation due to propagation effects in magnetospheric shearing regions. It is shown that turbulence on a scale of approximately 10 cm can produce these quasi-periodic modulations over a frequency range comparable to that of observed microstructure.

Harding, A. K.↗

Geometric moire methods with enhanced sensitivity by optical/digital fringe multiplication

A robust fringe-shifting and image processing scheme is applied to geometric moire experiments. High quality contour maps of U, V and W displacement fields are obtained with sensitivity enhanced by a factor of ten. The method is compatible with complicated intensity distributions, variable bar-to-space ratios of gratings, and optical noise. It is applicable to large fields for both in-plane moire and shadow moire measurements.

Han, B.↗

Application of Phase Shifted, Laser Feedback Interferometry to Fluid Physics

We have combined the principles of phase-shifting interferometry (PSI) and laser-feedback interferometry (LFI) to produce a new instrument that can measure both optical path length (OPL) changes and discern sample reflectivity variations. In LFI, coherent feedback of the incident light either reflected directly from a surface or reflected after transmission through a region of interest will modulate the output intensity of the laser. LFI can yield a high signal-to-noise ratio even for low reflectivity samples. By combining PSI and LFI, we have produced a robust instrument, based upon a HeNe laser, with high dynamic range that can be used to measure either static (dc) or oscillatory changes along the optical path. As with other forms of interferometry, large changes in OPL require phase unwrapping. Conversely, small phase changes are limited by the fraction of a fringe that can be measured. We introduce the phase shifts with an electro-optic modulator (EOM) and use either the Carre or Hariharan algorithms to determine the phase and visibility. We have determined the accuracy and precision of our technique by measuring both the bending of a cantilevered piezoelectric bimorph and linear ramps to the EOM. Using PSI, sub-nanometer displacements can be measured. We have combined our interferometer with a commercial microscope and scanning piezoelectric stage and have measured the variation in OPL and visibility for drops of PDMS (silicone oil) on coated single crystal silicon. Our measurement of the static contact angle agrees with the value of 68 deg stated in the literature.

Ovryn, Ben↗