Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

A Handheld Medical Diagnostic Device for Harsh Environments

Medical diagnostic capabilities for extreme environments, are currently limited in nature to single marker type assays. We propose to develop a handheld device for medical diagnostics in extreme environments that provide sensitive and specific detection of biomarkers with an emphasis initially on radiation exposure. Such a device will have multiple uses, and will be easily adaptable to many applications. For example, first responders, the battlefield, in low resource settings in developing countries facing emerging disease outbreaks, and during long-duration space flights. To this end, we will develop highly adaptable microfluidic devices (cards) for profiling different biomarkers with an emphasis on those related to radiation exposure. We will leverage the previous centrifugal separator work from LLNL and Sandia National Laboratory. The radiation exposure biomarker work at LLNL will provide a biological platform for demonstrating the utility of the device. We will develop a fluidic system using a pump-less mechanical method (centrifugal) to move, control, order and layer fluids in the platform. This decreases complexity, while enabling simultaneous cell separation and plasma generation for two uses: the first is differential blood cell counts and the second is biomarker assay panels. This work will be accomplished in three Aims: Aim 1) Test multiplex microfluidic cards and integrated reader. Aim 2) Demonstrate system capabilities to take and process blood samples for multi-endpoint analysis. Aim 3) Test multiplex detection based on measuring differential blood cell counts, while measuring plasma protein biomarkers. The proposed work addresses the mission research challenge of chemical and biological countermeasure in that our work aims to provide new research capabilities to respond to man-made or natural outbreaks of pandemic diseases in particular in low resource and triage environments.

60 APPLIED LIFE SCIENCES↗

TURBO: Terabits/s Using Reconfigurable Bandwidth Optics (Final Report)

Large scale, big science applications are generating petabytes of data that need to be shared among multiple locations. Moving a petabyte of data at 100 Gb/s takes 22 hours. Reducing this to single digit hours or below is clearly attractive and with future applications anticipating exabyte scale transfers, multi-terabit per second capacities are needed. This scale of capacity is available using optical systems. Core optical systems have aggregate per fiber capacities on the order of 10 Tb/s and more than 100 Tb/s system experiments have been realized in the lab. But large optical capacities are not just reserved for the core as similar system capacities are available in metro networks right up to the enterprise, campus, or data center. In general, the same technology is used today in the metro area as in the long-haul networks—reconfigurable optical add drop multiplexing (ROADM) node-based wavelength division multiplexing (WDM) systems. Data centers already support massive internal capacities on the scale of 100’s of Tb/s. As new photonic integrated technologies mature, for example through initiatives such as the Integrated Photonics Innovative Manufacturing Institute (IP-IMI), the cost of optical interfaces is expected to decrease, and higher capacity and higher performance interfaces will become more affordable. This set of circumstances creates the potential that Tb/s capacities will be available at the enterprise and campus level to support large scale science network applications.

42 ENGINEERING↗

High Brightness High Duty Factor Negative Ion Beam Injector [Slides]

The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.

43 PARTICLE ACCELERATORS↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

Agilent CRADA (Abstract)

The CRADA between Agilent Technologies Inc. and Battelle will focus on five software components as listed below: Prototype 4D Feature Finding functionality with a particular focus on recovering low level features and extending the bottom end dynamic range of IM-MS technology. Compare and contrast developments to current 4D Feature Finding capabilities. Highlight important algorithmic aspects employed. Implement the PNNL saturation correction algorithm. Agilent will give PNNL the needed data file access API and assistance in understanding it implementation and any needed instrumental aspects. Supported high resolution products to include Agilent’s TOF, QTOF and IM-QTOF mass spectrometers. PNNL will then work with Agilent to benchmark performance. Implementation of the PNNL Hadamard de-multiplexing algorithm. Agilent will give provide PNNL the needed date file access API access and as needed assistance in understanding the current Agilent multiplexed IM offering. PNNL will then work with Agilent on benchmark performance. Add ion mobility collision cross sections to existing and new metabolomic libraries for data analysis with Agilent’s informatics program MPP/ID Browser. PNNL will work with Agilent to create a software pipeline that takes data from chemical and metabolic standards and properly formats it for inclusion in MPP accessible libraries, using the collision cross section as a new separation dimension. Improvements of MPP multidimensional matching to identify metabolomic features using multiple characteristics beyond retention time and accurate mass. Most significantly matching will include analyte collision cross section with proposed support for sample fraction or RapidFire cartridge and fragmentation spectra. PNNL will work with Agilent to modify and improve the current MPP analysis pipeline to allow for creating, aligning, and identifying MS features defined by accurate mass, collision cross section and chromatographic retention time. As additional criteria such as fraction or RapidFire cartridge type are supported in the identification process, then they also will become part of the automation workflow. This includes the automation of said system to work with command line program (i.e. not a GUI) sufficient for programmatic execution in a pipeline.

97 MATHEMATICS AND COMPUTING↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

The EBEX Balloon-borne Experiment—Detectors and Readout

EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilopixel array of transition edge sensor bolometers aboard a balloon platform. We determine the design and characterization of the array and the readout system. From the lowest to highest frequency, the median measured detectors' average thermal conductances were 39, 53, and 63 pW/K, the medians of transition temperatures were 0.45, 0.48, and 0.47 K, and the medians of normal resistances were 1.9, 1.5, and 1.4 Ω; moreover, we give the measured distributions. With the exception of the thermal conductance at 150 GHz, all measured values are within 30% of their design. We measure median low-loop-gain time constants τ 0 = 88, 46, and 57 ms. Two measurements of bolometer absorption efficiency gave results consistent within 10% and showing high (~0.9) efficiency at 150 GHz and medium (~0.35 and ~0.25) efficiency at the two higher bands. We calculate a median total optical power absorbed of 3.6, 5.3, and 5.0 pW. EBEX pioneered the use of the digital version of the frequency domain multiplexing system. We multiplexed the bias and readout of 16 bolometers onto two wires. The median per-detector noise-equivalent temperatures are 400, 920, and 14,500 $\mu {{\rm{K}}}_{{\rm{cmb}}}\sqrt{{\rm{s}}}$. We compare these values to our preflight predictions and to a previous balloon payload. We report on the sources of excess noise and the path for a future payload to make full use of the balloon environment.

instrumentation: polarimeters↗

Flow cytometric detection method for DNA samples

Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

59 BASIC BIOLOGICAL SCIENCES↗

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A↗

Testing and operating a multiprocessor chip with processor redundancy

A system and method for improving the yield rate of a multiprocessor semiconductor chip that includes primary processor cores and one or more redundant processor cores. A first tester conducts a first test on one or more processor cores, and encodes results of the first test in an on-chip non-volatile memory. A second tester conducts a second test on the processor cores, and encodes results of the second test in an external non-volatile storage device. An override bit of a multiplexer is set if a processor core fails the second test. In response to the override bit, the multiplexer selects a physical-to-logical mapping of processor IDs according to one of: the encoded results in the memory device or the encoded results in the external storage device. On-chip logic configures the processor cores according to the selected physical-to-logical mapping.

97 MATHEMATICS AND COMPUTING↗

Derivation of GFDM Based on OFDM Principles

This paper starts with discussing the principle based on which the celebrated orthogonal frequency division multiplexing (OFDM) signals are constructed. It then extends the same principle to construct the newly introduced generalized frequency division multiplexing (GFDM) signals. This novel derivation sheds light on some interesting properties of GFDM. In particular, our derivation seamlessly leads to an implementation of GFDM transmitter which has significantly lower complexity than what has been reported so far. Our derivation also facilitates a trivial understanding of how GFDM (similar to OFDM) can be applied in MIMO channels.

5G↗

Integrated circuit test-port architecture and method and apparatus of test-port generation

A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

97 MATHEMATICS AND COMPUTING↗

Robust Ceramic Coaxial Cable Down-Hole Sensors for Long-Term In Situ Monitoring of Geologic CO 2 Injection and Storage

Energy generation by use of fossil fuels produces large volumes of CO 2 and other greenhouse gases, whose accumulation in the atmosphere is widely seen as undesirable. CO 2 Capture followed by sequestration has been identified as the solution. Subsurface geologic formations offer a potential location for long-term storage of CO 2 because of their requisite size. Unfortunately, the inaccessibility and complexity of the subsurface, the wide range of scales of variability, and the coupled nonlinear processes, impose tremendous challenges to determine the transport and predict the fate of the stored CO 2 . Among the various monitoring approaches, in situ down-hole monitoring of the various state parameters provides critical and direct data points that can be used to validate the models, optimize the injection, detect leakage and track the CO 2 plume. However, down-hole sensors that can withstand the harsh conditions and operate over decades of the project lifecycle remain unavailable. Given that the widespread of carbon capture and storage will be the necessity and reality in the future, fundamental and applied research is required to address the significant challenges and technological gaps in lack of long-term reliable down-hole sensors This project focused on the development and demonstration of a novel, low-cost, distributed, robust ceramic coaxial cable sensor platform for in situ down-hole monitoring of geologic CO 2 injection and storage with high spatial and temporal resolutions. The coaxial cable Fabry-Perot interferometer (CCFPI) has been studied as a general sensor platform for in situ, long-term, measurement of temperature, pressure and strain, which are critical to CO 2 injection and storage. A novel signal processing scheme has been developed and demonstrated for dense multiplexing of the sensors for low-cost distributed sensing with high spatial resolution. The developed temperature, pressure and strain sensors have been extensively tested under laboratory conditions that are similar to the downhole CO 2 storage environment, showing excellent capability for in situ monitoring the various parameters that are important to model, optimize the injection, detect leakage and track the CO 2 plume. In addition, the interactions between the sensor datum and the geological models have been investigated in details for the purposes of model validation, guiding sensor installation/placement, enhancement of model prediction capability and optimization of the injection processes. This project has resulted in the successful development of new ceramic coaxial cable based sensor systems that can monitor directly the changes in pressure, temperature, and strain caused by increased reservoir pressure and reduced reservoir temperature due to the supercritical CO 2 injection. Integrated with geological models, the sensors and measurement data can improve the possibility to identify plume movement and leakage in the cap rock and wells with higher precision and more accuracy. The low cost, ease of deployment, small size and dense multiplexing features of the new sensing technology will allow a large number of sensors to be deployed to address the objective to demonstrate that 99% of the CO 2 remains in the injection zone.

01 COAL, LIGNITE, AND PEAT↗

Self-balanced modulation and magnetic rebalancing method for parallel multilevel inverters

A self-balanced modulation method and a closed-loop magnetic flux rebalancing control method for parallel multilevel inverters. The combination of the two methods provides for balancing of the magnetic flux of the inter-cell transformers (ICTs) of the parallel multilevel inverters without deteriorating the quality of the output voltage. In various embodiments a parallel multi-level inverter modulator is provide including a multi-channel comparator to generate a multiplexed digitized ideal waveform for a parallel multi-level inverter and a finite state machine (FSM) module coupled to the parallel multi-channel comparator, the FSM module to receive the multiplexed digitized ideal waveform and to generate a pulse width modulated gate-drive signal for each switching device of the parallel multi-level inverter. The system and method provides for optimization of the output voltage spectrum without influence the magnetic balancing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microfluidic Cell-based Assays in Stem Cell and Other Rare Cell Type Research

Microfluidics is a technology defined by the engineered precise manipulation of minute amount of liquids through channels with dimensions in the micron scale. Much of microfluidic devices used for biomedical purposes are produced in the form of so called “lab-on-a-chip” format, where multiple steps of conventional biochemical analyses such as staining, washing, and signal collection are miniaturized and integrated into chips fabricated from polymer or glass. Cell-based microfluidic lab-on-achip technology provides some obvious advantages: 1) drastically reduced sample and reagent requirement, and 2) separation and detection with improved sensitivity due to fluid properties at the microscale, i.e. laminar flow. Based on these two advantages, the obvious place where microfluidic cell assays will provide the most benefit is wherescientists must gather much information from precious little sample. Stem cells and other precious cell types such as circulating tumor cells (CTCs), and rare immune subsets are the perfect match for microfluidic multiplex assays. The recent demonstration that multiple cellular changes such as surface receptor activation, protein translocation, long and short RNA, and DNA changes can all be extracted from intact single cells paves the way to systems level understanding of cellular states during development or disease. Finally, with the ability to preserve cell integrity in a microfluidic device during multiplexed analysis, one also preserves the single cell resolution, where information regarding the cell-to-cell heterogeneity during differentiation or response to stimuli is vitally important.

59 BASIC BIOLOGICAL SCIENCES↗

Method and system for high performance real time pattern recognition

Systems and methods supporting high performance real time pattern recognition by including time and regional multiplexing using high bandwidth, board-to-board communications channels, and 3D vertical integration. An array of processing boards can each be coupled a rear transition board, the array achieving time and regional multiplexing using high bandwidth board-to-board communications channels and 3D vertical integration.

42 ENGINEERING↗