Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

X-ray induced electron and ion fragmentation dynamics in IBr

Characterization of the inner-shell decay processes in molecules containing heavy elements is key to understanding x-ray damage of molecules and materials and for medical applications with Auger-electron-emitting radionuclides. The 1s hole states of heavy atoms can be produced by absorption of tunable x rays and the resulting vacancy decays characterized by recording emitted photons, electrons, and ions. The 1s hole states in heavy elements have large x-ray fluorescence yields that transfer the hole to intermediate electron shells that then decay by sequential Auger-electron transitions that increase the ion’s charge state until the final state is reached. In molecules, the charge is spread across the atomic sites, resulting in dissociation to energetic atomic ions. We have used x-ray/ion coincidence spectroscopy to measure charge states and energies of Iq+ and Brq′+ atomic ions following 1s ionization at the I and Br K-edges of IBr. We present the charge states and kinetic energies of the two correlated fragment ions associated with core-excited states produced during the various steps of the cascades. Here, to understand the dynamics leading to the ion data, we develop a computational model that combines Monte-Carlo/Molecular-Dynamics (MC/MD) simulations with a classical over-the-barrier model to track inner-shell cascades and redistribution of electrons in valence orbitals and nuclear motion of fragments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Subcloud Mesoscale Convergence in Sculpting Convective Updraft Width and Depth

The initiation of deep moist convection is governed in part by the horizontal width of updrafts near cloud base, which limits the deleterious effects of entrainment-driven dilution on buoyant thermals ascending through the free troposphere. However, the factors controlling cloud-base updraft width, which in turn dictates cloud depth, are not well understood. We track the evolving three-dimensional structure of the mesoscale subcloud forcing for vertical motion and near-cloud thermodynamic ingredients within a high-resolution ensemble of simulations of seven realistic daytime orographic convection initiation events to determine their relative roles in controlling cloud width and depth. Statistical analysis of approximately 5000 cloudy updraft samples indicates that the most important contributors to the width of cloudy updrafts across the ensemble are the depth and magnitude of the subcloud mesoscale ascent. However, the depth achieved by clouds is more consistently predicted by the near-cloud ambient relative humidity within the lower to middle free troposphere and convective available potential energy. Therefore, although the width of cloudy updrafts may be partly set at low levels by the mesoscale vertical mass and moisture flux, the likelihood of deep moist convection is governed by the generation of positive buoyancy within cumulus thermals and entrainment-driven dilution that reduces it. The persistence of the low-level mesoscale vertical forcing locally consolidates and vertically transports boundary layer moisture, helping to reduce updraft dilution. However, these factors vary in relative impacts on cloudy updrafts across individual cases, indicating multiple pathways for deep convection initiation.

Convective storms↗

LaplaceV1.0

Laplace is a electric field driven flow simulation program for detailed device design support. Transport processes include electrokinesis, dielectrophoresis, and diffusion. Laplace solves for the electric field in a microfluidic system and the liquid and particle flow that is produced by the electric field for the primary purpose of microfluidic design development and simulation. Laplace allows you to visualize the flow by tracking tracer particles, viewing flow streamlines, etc. Laplace can make movies of simulated particle motion to allow you to test and share the behavior of microfuidic designs. The electric field is calculated using an iterative linear solver and particle motion is solved by finite difference, finite-displacement simulation of particle trajectories. Laplace uses a bitmapped picture or drawing of a microsystem to infer the geometry. The channel depth is everywhere proportional to the magnitude of the blue channel of the image: 0 (black) = zero depth, or no channel, 256 (saturated blue) = deepest channel, and intermediate values correspond to intermediate depths. Laplace automatically applies various boundary conditions (applied voltage or current) to ports, where channels cross the edge of the image.

Cummings, Eric↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A role for myosin VI in retinal pigment epithelium phagocytosis

Highlights: • Quashing myosin VI activity reduces rates of phagosome trafficking in RPE cells. • Trafficked phagosomes in RPE cells undergo two modes of motion. • The more randomly directed mode of phagosome trafficking is myosin VI dependent. • The more directed mode of phagosome trafficking is myosin VI independent. The retinal pigment epithelium (RPE) is a monolayer of pigmented cells adjacent to the choroid coat, the vascular layer of the eye. Among other functions, these cells are responsible for the phagocytosis of rod and cone cell waste shed from the photoreceptor outer segments. We describe here studies to understand the involvement of the motor protein myosin VI in the trafficking of internalized microspheres by a human retinal pigment epithelium primary cell line (ARPE-19). We perturbed the myosin VI-actin interaction by overexpressing a dominant negative myosin VI construct in these cells. We used single particle tracking to characterize the trajectories of internalized fluorescent microspheres. Analysis of the speed of the microspheres' motions revealed that the magnitude of the average speed over short time scales is reduced in the presence of the dominant negative motor. Analysis of the mean-squared displacement of these trajectories demonstrated that trafficking of phagosomes involves two modes of motion, a rapid, more randomly directed motion that is myosin VI dependent and a slower, more directed motion that is independent of the motor. From these data, we posit that this trafficking process involves an interplay between myosin VI motors, which are involved in motion through the actin periphery of the cell, and microtubule motors.

60 APPLIED LIFE SCIENCES↗

4D tumor centroid tracking using orthogonal 2D dynamic MRI: Implications for radiotherapy planning

Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited “snapshot” in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and associated variability over durations more consistent with treatments, the authors have developed a practical dynamic MRI (dMRI) technique employing two orthogonal planes acquired in a continuous, interleaved fashion.Methods: 2D balanced steady-state free precession MRI was acquired continuously over 9–14 min at approximately 4 Hz in three healthy volunteers using a commercial 1.5 T system; alternating orthogonal imaging planes (sagittal, coronal, sagittal, etc.) were employed. The 2D in-plane pixel resolution was 2 × 2 mm{sup 2} with a 5 mm slice profile. Simultaneous with image acquisition, the authors monitored a 1D surrogate respiratory signal using a device available with the MRI system. 2D template matching-based anatomic feature registration, or tracking, was performed independently in each orientation. 4D feature tracking at the raw frame rate was derived using spline interpolation.Results: Tracking vascular features in the lung for two volunteers and pancreatic features in one volunteer, the authors have successfully demonstrated this method. Registration error, defined here as the difference between the sagittal and coronal tracking result in the SI direction, ranged from 0.7 to 1.6 mm (1σ) which was less than the acquired image resolution. Although the healthy volunteers were instructed to relax and breathe normally, significantly variable respiration was observed. To demonstrate potential applications of this technique, the authors subsequently explored the intrafraction stability of hypothetical tumoral internal target volumes and 3D spatial probability distribution functions. The surrogate respiratory information allowed the authors to show how this technique can be used to study correlations between internal and external (surrogate) information over these prolonged durations. However, compared against the gold standard of the time stamps in the dMRI frames, the temporal synchronization of the surrogate 1D respiratory information was shown to be likely unreliable.Conclusions: The authors have established viability of a novel and practical pretreatment, 4D tumor centroid tracking method employing a commercially available dynamic MRI sequence. Further developments from the vendor are likely needed to provide a reliably synchronized surrogate 1D respiratory signal, which will likely broaden the utility of this method in the pretreatment radiotherapy planning context.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed spiral imaging technique for an atomic force microscope using a linear quadratic Gaussian controller

This paper demonstrates a high-speed spiral imaging technique for an atomic force microscope (AFM). As an alternative to traditional raster scanning, an approach of gradient pulsing using a spiral line is implemented and spirals are generated by applying single-frequency cosine and sine waves of slowly varying amplitudes to the X and Y-axes of the AFM’s piezoelectric tube scanner (PTS). Due to these single-frequency sinusoidal input signals, the scanning process can be faster than that of conventional raster scanning. A linear quadratic Gaussian controller is designed to track the reference sinusoid and a vibration compensator is combined to damp the resonant mode of the PTS. An internal model of the reference sinusoidal signal is included in the plant model and an integrator for the system error is introduced in the proposed control scheme. As a result, the phase error between the input and output sinusoids from the X and Y-PTSs is reduced. The spirals produced have particularly narrow-band frequency measures which change slowly over time, thereby making it possible for the scanner to achieve improved tracking and continuous high-speed scanning rather than being restricted to the back and forth motion of raster scanning. As part of the post-processing of the experimental data, a fifth-order Butterworth filter is used to filter noises in the signals emanating from the position sensors and a Gaussian image filter is used to filter the images. A comparison of images scanned using the proposed controller (spiral) and the AFM PI controller (raster) shows improvement in the scanning rate using the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head

Purpose: The Vero4DRT system has the capability for dynamic tumor-tracking (DTT) stereotactic irradiation using a unique gimbaled x-ray head. The purposes of this study were to develop DTT conformal arc irradiation and to estimate its geometric and dosimetric accuracy. Methods: The gimbaled x-ray head, supported on an O-ring gantry, was moved in the pan and tilt directions during O-ring gantry rotation. To evaluate the mechanical accuracy, the gimbaled x-ray head was moved during the gantry rotating according to input command signals without a target tracking, and a machine log analysis was performed. The difference between a command and a measured position was calculated as mechanical error. To evaluate beam-positioning accuracy, a moving phantom, which had a steel ball fixed at the center, was driven based on a sinusoidal wave (amplitude [A]: 20 mm, time period [T]: 4 s), a patient breathing motion with a regular pattern (A: 16 mm, average T: 4.5 s), and an irregular pattern (A: 7.2–23.0 mm, T: 2.3–10.0 s), and irradiated with DTT during gantry rotation. The beam-positioning error was evaluated as the difference between the centroid position of the irradiated field and the steel ball on images from an electronic portal imaging device. For dosimetric accuracy, dose distributions in static and moving targets were evaluated with DTT conformal arc irradiation. Results: The root mean squares (RMSs) of the mechanical error were up to 0.11 mm for pan motion and up to 0.14 mm for tilt motion. The RMSs of the beam-positioning error were within 0.23 mm for each pattern. The dose distribution in a moving phantom with tracking arc irradiation was in good agreement with that in static conditions. Conclusions: The gimbal positional accuracy was not degraded by gantry motion. As in the case of a fixed port, the Vero4DRT system showed adequate accuracy of DTT conformal arc irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical Simulations of Strong Shock and Disturbance Interactions Using High-Order Shock-Fitting Algorithms

High order methods that can solve flows involving interactions of flow-disturbances with shock waves are critical for reliable numerical simulation of strong-shock and turbulence interaction problems. Such problems are not well understood due to limitations of numerical methods. For numerical simulation of compressible flows, shock capturing schemes have been the most popular choice. However, most of such methods are inherently dissipative and may incur numerical oscillations near the shock. Present paper focuses on developing and implementing new algorithms based on shock-fitting and front-tracking methodology which can solve the flow with high-order accuracy near as well as away from the shocks. The shock-fitting algorithm avoids dissipation and possible numerical oscillations incurred in shock-capturing methods by treating shocks sharply. We explore two ways for shock-fitting: conventional moving grid set-up and a new fixed grid set-up with front tracking. Conventionally, shock fitting is implemented on moving grid while shock forms a boundary of the computational domain. However, shock-fitted grid generation can be tedious for large and complex motions of the shock-front. Hence, we have also worked on developing a fixed grid set-up for shock-fitting method where shock is tracked using Lagrangian points and is free to move across underlying fixed grid. Using these shock-fitting algorithms we have solved one and two dimensional interactions of shock and vorticity/entropy disturbance waves and results have been found to be very satisfactory. We have also carried out a rate of convergence study to establish that, unlike shock-capturing schemes, the shock-fitting methods are high-order accurate near the shock. Although problems considered in this paper are relatively simple, the quality of results obtained from shock-fitting method provides good motivation to pursue it further for the problems of shock-turbulence interactions. In future, fixed grid shock-fitting methodology will be further developed with Immersed interface method of Zhong and more robust front-tracking algorithms so that more complex shock-turbulence interaction problems can be considered.

Rawat, Pradeep↗

Dosimetric Impact of Intrafractional Patient Motion in Pediatric Brain Tumor Patients

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 {+-} 1.5 treatment fractions; motion data were acquired for a mean of 26 {+-} 6.2 fractions. The mean age was 15.6 {+-} 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional direct numerical simulation of a turbulent lifted hydrogen jet flame in heated coflow: flame stabilization and structure

Direct numerical simulation (DNS) of the near field of a three-dimensional spatially developing turbulent lifted hydrogen jet flame in heated coflow is performed with a detailed mechanism to determine the stabilization mechanism and the flame structure. The DNS was performed at a jet Reynolds number of 11,000 with over 940 million grid points. The results show that auto-ignition in a fuel-lean mixture at the flame base is the main source of stabilization of the lifted jet flame. A chemical flux analysis shows the occurrence of near-isothermal chemical chain branching preceding thermal runaway upstream of the stabilization point, indicative of hydrogen auto-ignition in the second limit. The Damköhler number and key intermediate-species behaviour near the leading edge of the lifted flame also verify that auto-ignition occurs at the flame base. At the lifted-flame base, it is found that heat release occurs predominantly through ignition in which the gradients of reactants are opposed. Downstream of the flame base, both rich-premixed and non-premixed flames develop and coexist with auto-ignition. In addition to auto-ignition, Lagrangian tracking of the flame base reveals the passage of large-scale flow structures and their correlation with the fluctuations of the flame base. In particular, the relative position of the flame base and the coherent flow structure induces a cyclic motion of the flame base in the transverse and axial directions about a mean lift-off height. This is confirmed by Lagrangian tracking of key scalars, heat release rate and velocity at the stabilization point.

Mechanics↗

Three-dimensional direct numerical simulation of a turbulent lifted hydrogen jet flame in a heated coflow: flame stabilization and structure

Direct numerical simulation (DNS) of the near field of a three-dimensional spatially developing turbulent lifted hydrogen jet flame in heated coflow is performed with a detailed mechanism to determine the stabilization mechanism and the flame structure. The DNS was performed at a jet Reynolds number of 11,000 with over 940 million grid points. The results show that auto-ignition in a fuel-lean mixture at the flame base is the main source of stabilization of the lifted jet flame. A chemical flux analysis shows the occurrence of near-isothermal chemical chain branching preceding thermal runaway upstream of the stabilization point, indicative of hydrogen auto-ignition in the second limit. The Damkoehler number and key intermediate-species behaviour near the leading edge of the lifted flame also verify that auto-ignition occurs at the flame base. At the lifted-flame base, it is found that heat release occurs predominantly through ignition in which the gradients of reactants are opposed. Downstream of the flame base, both rich-premixed and non-premixed flames develop and coexist with auto-ignition. In addition to auto-ignition, Lagrangian tracking of the flame base reveals the passage of large-scale flow structures and their correlation with the fluctuations of the flame base. In particular, the relative position of the flame base and the coherent flow structure induces a cyclic motion of the flame base in the transverse and axial directions about a mean lift-off height. This is confirmed by Lagrangian tracking of key scalars, heat release rate and velocity at the stabilization point.

08 HYDROGEN↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

An interface tracking model for droplet electrocoalescence.

This report describes an Early Career Laboratory Directed Research and Development (LDRD) project to develop an interface tracking model for droplet electrocoalescence. Many fluid-based technologies rely on electrical fields to control the motion of droplets, e.g. microfluidic devices for high-speed droplet sorting, solution separation for chemical detectors, and purification of biodiesel fuel. Precise control over droplets is crucial to these applications. However, electric fields can induce complex and unpredictable fluid dynamics. Recent experiments (Ristenpart et al. 2009) have demonstrated that oppositely charged droplets bounce rather than coalesce in the presence of strong electric fields. A transient aqueous bridge forms between approaching drops prior to pinch-off. This observation applies to many types of fluids, but neither theory nor experiments have been able to offer a satisfactory explanation. Analytic hydrodynamic approximations for interfaces become invalid near coalescence, and therefore detailed numerical simulations are necessary. This is a computationally challenging problem that involves tracking a moving interface and solving complex multi-physics and multi-scale dynamics, which are beyond the capabilities of most state-of-the-art simulations. An interface-tracking model for electro-coalescence can provide a new perspective to a variety of applications in which interfacial physics are coupled with electrodynamics, including electro-osmosis, fabrication of microelectronics, fuel atomization, oil dehydration, nuclear waste reprocessing and solution separation for chemical detectors. We present a conformal decomposition finite element (CDFEM) interface-tracking method for the electrohydrodynamics of two-phase flow to demonstrate electro-coalescence. CDFEM is a sharp interface method that decomposes elements along fluid-fluid boundaries and uses a level set function to represent the interface.

Erickson, Lindsay Crowl↗

A Deliverable Four-Dimensional Intensity-Modulated Radiation Therapy-Planning Method for Dynamic Multileaf Collimator Tumor Tracking Delivery

Purpose: To develop a deliverable four-dimensional (4D) intensity-modulated radiation therapy (IMRT) planning method for dynamic multileaf collimator (MLC) tumor tracking delivery. Methods and Materials: The deliverable 4D IMRT planning method involves aligning MLC leaf motion parallel to the major axis of target motion and translating MLC leaf positions by the difference in the target centroid position between respiratory phases of the 4D CT scan. This method ignores nonlinear respiratory motion and deformation. A three-dimensional (3D) optimal method whereby an IMRT plan on each respiratory phase of the 4D CT scan was independently optimized was used for comparison. For 12 lung cancer patient 4D CT scans, individual phase plans and deformable dose-summed 4D plans using the two methods were created and compared. Results: For each of the individual phase plans, the deliverable method yielded similar isodose distributions and dose-volume histograms. The deliverable and 3D optimal methods yielded statistically equivalent dose-volume metrics for both individual phase plans and 4D plans (p > 0.05 for all metrics compared). The deliverable method was affected by 4D CT artifacts in one case. Both methods were affected by high vector field variations from deformable registration. Conclusions: The deliverable method yielded similar dose distributions for each of the individual phase plans and statistically equivalent dosimetric values compared with the 3D optimal method, indicating that the deliverable method is dosimetrically robust to the variations of fractional time spent in respiratory phases on a given 4D CT scan. Nonlinear target motion and deformation did not cause significant dose discrepancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of magnetic fields on HPGe tracking detectors

Here, we present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers. By solving the equations of motion for the electron and holes in the presence of both electric and magnetic fields, we analyzed the drift trajectories of the charge carriers to determine the deviations in the positions at the end point of the trajectories, as well as changes in drift lengths affecting the energy resolution and peak shift due to trapping. Our results show that the major effect is in the deviation of the transverse (to the electric field direction) position and suggest that, if no corrective action is taken in the pulse-shape and tracking data analysis procedures, a field strength ≳ 0.1 T will start to impact the intrinsic position resolution of 2 mm (RMS). At fields above ~1 T, the degradation of the energy response becomes observable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Room PET Scanner for Natural Environment Neuroscience Research

A room size PET scanner for neuroscience research is proposed in which subjects can move about freely in a natural environment. This scanner, termed RoomPET, would open new frontiers in the study of dynamic brain function. The key to a feasible system is PET detectors with a limited vertical dimension that may translate up and down to keep the brain in the field of view. Head position can be tracked by an array of video cameras, providing real-time data to guide detector motion and for motion-corrected image reconstruction. For a point in the center of the room and centered within the vertical field of view of the detectors, geometric sensitivity ranges between 4 and 18% for room widths of 2 to 3 m and detectors with vertical dimensions of 15 to 40 cm. Spatial resolution is dominated by annihilation photon non-colinearity due to the large detector separation. This non-colinearity contribution for F-18 is 4.4 and 6.6 mm full width at half maximum (FWHM) at the center of 2 ×2 and 3×3m 2 rooms, respectively, for a line of response orthogonal to the opposite walls. With pixelated scintillation crystal elements 2 mm on a side the system resolution for F-18 radiotracers is estimated at 4.5 and 6.7 mm FWHM for room widths of 2 and 3 m, respectively. A RoomPET system would advance the understanding of brain function in healthy humans and in those with neurological diseases, disorders and brain injury.

Smith, Mark F.↗