Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Estimation of Modal Parameters Using a Wavelet-Based Approach

Modal stability parameters are extracted directly from aeroservoelastic flight test data by decomposition of accelerometer response signals into time-frequency atoms. Logarithmic sweeps and sinusoidal pulses are used to generate DAST closed loop excitation data. Novel wavelets constructed to extract modal damping and frequency explicitly from the data are introduced. The so-called Haley and Laplace wavelets are used to track time-varying modal damping and frequency in a matching pursuit algorithm. Estimation of the trend to aeroservoelastic instability is demonstrated successfully from analysis of the DAST data.

Lind, Rick↗

SU-E-I-83: Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom

Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement errors during the animal study.

60 APPLIED LIFE SCIENCES↗

Model updating based on sensitivities of system matrices

A new approach, which allows the physical parameters to be adjusted and preserves the structural connectivity condition, is developed in this paper. This approach is based on the sensitivities of the mass and stiffness matrices with respect to physical parameters in an attempt to use test data to correct the analytical model. The analytical mass and stiffness matrices can be corrected simultaneously. The modal data of the updated model dramatically converges to that of the test model. A numerical example is presented to illustrate the feasibility of this approach. Comparisons with the other methods are also given.

Huang, Hsin-Hsen↗

A modal separation measurement technique for broadband noise propagating inside circular ducts

A measurement technique which separates broadband noise propagating inside circular ducts into the acoustic duct modes is developed. The technique is also applicable to discrete frequency noise. The acoustic modes are produced by weighted combinations of the instantaneous outputs of microphones spaced around the duct circumference. The technique is compared with the cross spectral density approach presently available and found to have certain advantages, and disadvantages. Considerable simplification of both the new technique and the cross spectral density approach occurs when no correlation exists between different circumferential mode orders. The properties leading to uncorrelated modes and experimental tests which verify this condition are discussed. The modal measurement technique is applied to the case of broadband noise generated by flow through a coaxial obstruction (nozzle or orifice) in a pipe. Different circumferential mode orders are shown to be uncorrelated for this type of noise source.

Kerschen, E. J.↗

Required developments in structural dynamics

The finite element method, modal component synthesis, and the use of fast Fourier transformation were key developments in structural dynamics in the past 15 to 20 years. Current areas requiring additional effort include: (1) the correct calculation of modal shape and natural frequencies for complex structures; (2) the correlation of math models with test data; (3) the establishment of a criteria for "goodness" of the correlation between analysis and test; (4) the selection of the correct displacement functions when using computer programs for modal synthesis; (5) accuracy of response calculations; and (6) the inverse problem of determining the force problem from the response data. Trends identified include the use of distributed computing, greater reliance on analysis, and the possible use of artificial intelligence techniques, or some way of feeding back information, to provide solution guidance to engineers.

Wada, B. K.↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-03: Workshop [ Advancements in high intensity focused ultrasound ]

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Thermal Vacuum Testing of ICPTA RCS at Plum Brook B-2

Vacuum and thermal vacuum testing of the Integrated Cryogenic Propulsion Test Article (ICPTA) was performed at the Plum Brook B-2 facility as a part of a system checkout and facility characterization effort. Multiple test objectives included: integrated Reaction Control System (RCS) characterization, cold helium pressurization system characterization, modal propellant gaging experiment (Orion), CFM propellant loading experiments, main engine characterization. The ICPTA is a test bed for LOX/LCH4 technologies built in 2016 using new components and hardware from the former Morpheus vehicle and other projects.

Atwell, M. J.↗

Method for Real-Time State Estimation of Structural Modes for an Aeroelastic Wind Tunnel Model

A method for estimating displacements, velocities, and accelerations of structural modes in generalized coordinates from measured sensor data in real time is developed and demonstrated. Data from conventional strain gauges and fiber optic strain sensors (FOSS) were combined with strain mode shapes to produce least-squares estimates of the structural mode displacements. Similarly, accelerometer data were combined with displacement mode shapes to estimate structural mode accelerations. Estimates were then combined using a Kalman filter to refine the displacement estimates and produce structural mode velocity estimates. The approach was demonstrated using simulation data for the NASA-Boeing collaboration called the Integrated Adaptive Wing Technology Maturation (IAWTM) project in both a stable open-loop condition and an unstable condition where estimated displacement and velocity states were used for feedback control. Results supported the feasibility of using this approach for feedback control and system identification applications for wind tunnel tests.

Aeroservoelasticity↗

Single-Mode Projection Filters for Modal Parameter Identification for Flexible Structures

Single-mode projection filters are developed for eigensystem parameter identification from both analytical results and test data. Explicit formulations of these projection filters are derived using the orthogonal matrices of the controllability and observability matrices in the general sense. A global minimum optimization algorithm is applied to update the filter parameters by using the interval analysis method. The updated modal parameters represent the characteristics of the test data. For illustration of this new approach, a numerical simulation for the MAST beam structure is shown by using a one-dimensional global optimization algorithm to identify modal frequencies and damping. Another numerical simulation of a ten-mode structure is also presented by using a two-dimensional global optimization algorithm to illustrate the feasibility of the new method. The projection filters are practical for parallel processing implementation.

Huang, Jen-Kuang↗

Single-mode projection filters for modal parameter identification for flexible structures

Single-mode projection filters are developed for eigensystem parameter identification from both analytical results and test data. Explicit formulations of these projection filters are derived using the orthogonal matrices of the controllability and observability matrices in the general sense. A global minimum optimization algorithm is applied to update the filter parameters by using the interval analysis method. The updated modal parameters represent the characteristics of the test data. For illustration of this new approach, a numerical simulation for the MAST beam structure is shown by using a one-dimensional global optimization algorithm to identify modal frequencies and damping. The projection filters are practical for parallel processing implementation.

Huang, Jen-Kuang↗

Shake Test of a Propeller Test Rig in the 40- by 80-Foot Wind Tunnel

A shake test was conducted to determine the dynamic characteristics of a propeller test rig in the Ames 40- by 80-Foot Wind Tunnel. The rotor off hub transfer function (acceleration per unit force as a function of frequency) was measured in the longitudinal, lateral, and vertical directions for shaft angles of 0 and 90 deg corresponding to propeller and helicopter operation, respectively. The dynamic data are summarized for the configurations tested, giving the following properties for each mode identified: the natural frequency, the hub response at resonance, the damping coefficient, the damping ratio, and the modal mass. The complete transfer functions are presented, and the detailed test results are included.

Johnson, W.↗

Data-Driven Method for Nonlinear Modal Interaction Identification in Fighter Aircraft

The purpose of this paper is to report a new data-driven analysis methodology for identifying nonlinear modal interactions and its application to aeroelastic wind-tunnel data from a generic fighter configuration, which reveals global modal interactions in this system caused by multiple resonance capture events initiated by local nonlinearities. It is shown that during supersonic testing at the Transonic Dynamics Tunnel, vibro-impacts at the embedded external fuel tank shakers on the inboard underwing stations of the generic fighter introduce strong nonlinearity that gives rise to nonlinear modal interactions. Specifically, time–frequency analysis of the acceleration data demonstrates that 6∶5 and 7∶6 transient resonance captures occur across the aircraft exclusively during this vibro-impact forcing window. Further analysis suggests that these resonance captures are dependent on Mach number. These results show experimentally that local vibro-impacts can cause global nonlinear effects in an aeroelastic system and that these effects can be identified using the new methodology herein. The data-driven analysis scheme employed shows applicability to full-aircraft flight test data for identifying nonlinear modal interactions without knowledge of the precise nonlinear contributors.

nonlinear dynamics↗

On-line structural parameter identification

Algorithms are presented for on-line parameter identification of structural dynamic systems. As an example, they are used to calculate the parameters of a modal model of a flexible beam. The algorithms are tested using hardware consisting of a 12 ft. beam with four voice coil actuators and nine noncontacting displacement sensors. They are programmed in a CDC Cyber 175 digital computer which provides input command signals for the actuators, reads the sensor data, and processes the algorithm to calculate consistent estimates of the modal parameters of the beam. Experimental results are compared with those of simulation analysis.

Thau, F. E.↗

Moving Beyond the Standard of Care: Accelerate Testing of Radiation-Drug Combinations

Radiation therapy is a major treatment modality used in > 60% of cancer patients as definitive local treatment for inoperable locoregionally confined tumors and as palliative therapy. Although cytotoxic chemotherapy enhances the effectiveness of treatment, the benefit over radiation therapy alone is modest. There is a need to enhance the effectiveness of local tumor control over what sequentially or concurrently administered cytotoxic chemotherapy provides. Although many biological pathways are known to enhance the effectiveness of radiation therapy, there is currently a paucity of drugs approved for use in combination. Several clinical trials have tested the effectiveness of combining targeted agents or immunotherapies with radiation therapy, but the results of these trials have been negative, likely stemming from the relative lack of preclinical evidence using appropriate experimental standardization or model systems. Accelerating the identification of agents tested in an appropriate clinical context and experimental systems or models would greatly enhance the potential to bring forward early testing of drugs that would not only be safe but also more effective. This article provides an overview of the opportunities and challenges of developing therapeutics to combine with radiation therapy, and some guidance toward preclinical and early clinical testing to improve the chance that advanced phase testing of drug-radiation combinations would be successful in the long term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity of Space Station Alpha Joint robust controller to structural modal parameter variations

The baseline design of the photovoltaic-array sun-tracking control system is presented with special attention given to the optimization of design variables related to stability and performance. The procedures utilized to attenuate control/structure interaction are described, and controller sensitivity to variations in structural modal parameters is examined. Constrained optimization techniques determine the stability margin and tracking capability, which are then tested for sensitivity to variations in natural frequency, mode-shape amplitudes, and modal-damping ratios. The effect of variations in the modal parameters of the dominant modes on performance indicators is also examined to optimize tracking-performance responsiveness and satisfy the design requirements. It is concluded that accurate on-orbit modal data are necessary to make the reoptimization procedure effective in improving the performance of the control system.

Kumar, Renjith R.↗