Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Single-molecule imaging of lignocellulose deconstruction by SCATTIRSTORM microscopy

The goal of this project is to build a multimodal optical microscope to measure the binding, processive degradation, and pausing behaviors of cellulases as they interact with and degrade both synthetic and naturally occurring lignocellulosic walls. To achieve this, we will use high spatio-temporal single-molecule imaging to track cellulases, while visualizing specific molecular components of cellulose, lignin and hemicellulose, that make up their lignocellulose substrate. The microscope will combine Interferometric Scattering (iSCAT), which provides unprecedented spatiotemporal resolution; Total Internal Reflection Fluorescence (TIRF), which provides single-molecule resolution of multiple fluorophore-labeled molecules; and Stochastic Reconstruction (STORM), which allows for three-dimensional super-resolution imaging of intact plant cell walls during degradation. Initial studies will investigate cellulase dynamics on in vitro-assembled cell wall analogs, and later work will progress to using native plant cell walls.

09 BIOMASS FUELS↗

Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy

Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10 nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si{sub 3}N{sub 4}) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si{sub 3}N{sub 4} film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glycogen in the Nervous System: Methods for Light and Electron Microscopy - I

'l'he relative value of different methods for combined light and electron microscopical studies of glycogen in the nervous tissue was investigated. Picroalcoholic fixatives preserve glycogen in a considerable amount but give an inadequate morphological image of glycogen distribution and are unsuitable for ultrastructural studies. Fixation by perfusion, with Dalton's chromeosmic fluid seems adequate for ultrastructural cytochemistry of glycogen. Furthermore it permits routine paraffin embedding of brain slices adjacent to those used for electron microscopy. Dimedone blocking is a necessary step for a selective staining of glycogen with PAS after osmic fixation. Enzymatic removal of glycogen in osmic fixed nervous tissue can be done In paraffin-embedded tissue. It can also be performed in glycolmethacrylate-embedded tissue without removal of the embedding medium. Paraphenylenediamine stains glycogen following periodic acid oxidation.

Estable, Rosita F. De↗

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification, isolation, and characterization of a novel type of Fukushima-derived microparticle

Abstract In the course of the Fukushima nuclear accident, radionuclides were released in various forms, including so-called radiocesium-bearing microparticles (CsMP). So far, four types of CsMP were described: Type A is smaller in size (< 10 μm), Types B, C, and D are larger (> 100 μm). In this work, we present a novel type of CsMP (proclaimed Type E). Three particles of Type E were extracted from a contaminated blade of grass that was sampled 1.5 km from the Fukushima Daiichi nuclear power plant in late 2011. They were located using autoradiography, isolated using an optical microscope and micromanipulator, and characterized using scanning electron microscopy, energy dispersive x-ray spectroscopy, and low-level gamma-ray spectrometry. Type E CsMPs are 10–20 μm in size and exhibit an unusually low and barely detectable 137 Cs activity of only ≤ 10 mBq per particle. Their brittle and fragile character may indicate a high surface tension.

137Cs↗

Effect of Dual-Phase Heat Treatment on Microstructure and Mechanical Properties of S135 High-Strength Drill Pipe Steel

Effect of dual-phase heat treatment (DPHT) on microstructure and mechanical properties of S135 high-strength drill pipe steel was studied by means of optical microscope, scanning electron microscope and mechanical property testing. The results show that the ferrite–martensite dual-phase microstructures were obtained at 760-800 °C. With increase in DPHT temperature, the volume fraction of martensite increases and the ferrite decreases. When the DPHT temperature is low, martensite is distributed as an island on the ferrite matrix, and ferrite is distributed as an island on the martensite matrix when the DPHT temperature is high. The hardness and strength of the steel increase, the plasticity and toughness decrease, the steel changes from ductile fracture to brittle fracture and the micro-fracture morphology changes from dimple to cleavage with increase in DPHT temperature. The strain hardening exponent of the as-received steel shows one ‘n’ value, but exhibits two ‘n’ values after DPHT. When the DPHT temperature is 750 °C, the relative content of martensite in the duplex structure is 15-20%, and the impact energy of the steel is similar to that of the as-received S135 drill pipe steel, and the strength is increased by about 15%. Micropores and micro-cracks on the subsurface of tensile fracture surface are mainly formed at the martensite/ferrite phase boundary or in the martensite slit.

36 MATERIALS SCIENCE↗

Effect of Chromium Content on Microstructure, Hardness, and Wear Resistance of As-Cast Fe-Cr-B Alloy

The effects of chromium content on microstructure, hardness and wear resistance of as-cast Fe-xCr-1.0B (x = 0, 4, 8, 12, 16, 20) alloys were investigated by means of optical microscope (OM), scanning electron microscope (SEM), x-ray diffractometer (XRD), hardness tester and ring block wear tester. The results showed that the microstructures of chromium-free alloy were mainly composed of pearlite, ferrite, and eutectic borocarbides, and the hardness was very low, only 18.8 HRC. With the increase in chromium content, the matrix of as-cast Fe-Cr-B alloy gradually began to transform from pearlite and ferrite to lath martensite, and the type of borocarbides changed from Fe{sub 2}(B, C) to M{sub 2}(B, C), M{sub 7}(C, B){sub 3} and M{sub 23}(C, B){sub 6} (M = Fe, Cr). When the chromium content was 12 wt.%, the hardness of alloy reached the highest value of 61.1 HRC, and the wear resistance of alloy was the best. The results of worn surface analysis showed that the wear failure of as-cast Fe-Cr-B alloy was mainly caused by multiple plastic deformation and micro-cutting.

36 MATERIALS SCIENCE↗

Surface treated polypropylene (PP) fibres for reinforced concrete

Surface treatments on a polypropylene (PP) fibre have contributed to the improvement of fibre/concrete adhesion in fibre-reinforced concrete. The treatments to the PP fibre were characterized by contact angle measurements, ATR-IR and XPS to analyse chemical alterations. The surface topography and fibre/concrete interaction were analysed by several microscopic techniques, namely optical petrographic, and scanning electron microscopy. Treatment modified the surface chemistry and topography of the fibre by introducing sodium moieties and created additional fibre surface roughness. Modifications in the fibre surface led to an increase in the adhesion properties between the treated fibres and concrete and an improvement in the mechanical properties of the fibre-reinforced concrete composite as compared to the concrete containing untreated PP fibres. Compatibility with the concrete and increased roughness and mineral surface was also improved by nucleated portlandite and ettringite mineral association anchored on the alkaline PP fibre surface, which is induced during treatment.

36 MATERIALS SCIENCE↗

Characterization of boron carbide particulate reinforced in situ copper surface composites synthesized using friction stir processing

Friction stir processing has evolved as a novel solid state technique to fabricate surface composites. The objective of this work is to apply the friction stir processing technique to fabricate boron carbide particulate reinforced copper surface composites and investigate the effect of B{sub 4}C particles and its volume fraction on microstructure and sliding wear behavior of the same. A groove was prepared on 6 mm thick copper plates and packed with B{sub 4}C particles. The dimensions of the groove was varied to result in five different volume fractions of B{sub 4}C particles (0, 6, 12, 18 and 24 vol.%). A single pass friction stir processing was done using a tool rotational speed of 1000 rpm, travel speed of 40 mm/min and an axial force of 10 kN. Metallurgical characterization of the Cu/B{sub 4}C surface composites was carried out using optical microscope and scanning electron microscope. The sliding wear behavior was evaluated using a pin-on-disk apparatus. Results indicated that the B{sub 4}C particles significantly influenced the area, dispersion, grain size, microhardness and sliding wear behavior of the Cu/B{sub 4}C surface composites. When the volume fraction of B{sub 4}C was increased, the wear mode changed from microcutting to abrasive wear and wear debris was found to be finer. Highlights: • Fabrication of Cu/B{sub 4}C surface composite by friction stir processing • Analyzing the effect of B{sub 4}C particles on the properties of Cu/B4C surface composite • Increased volume fraction of B{sub 4}C particles reduced the area of surface composite. • Increased volume fraction of B{sub 4}C particles enhanced the microhardness and wear rate. • B{sub 4}C particles altered the wear mode from microcutting to abrasive.

36 MATERIALS SCIENCE↗

Microstructure and tensile properties of laser engineered net shaped reduced activation ferritic/martensitic steel

Highlights: • A RAFM steel has been successfully manufactured by laser engineered net shaping (LENS), which is one of laser additive manufacturing technologies. • Columnar dendrites in vertical section and a mixture of equiaxed and columnar grains in horizontal section have been observed. • The anisotropic tensile properties are induced by LENS process, which can be eliminated well through the heat treatment. - Abstract: A laser additive manufacturing technique, laser engineered net shaping (LENS), was successfully applied to manufacture a reduced activation ferritic/martensitic (RAFM) steel with nominal composition of Fe-9Cr-0.11C-1.5W-0.4Mn-0.2V-0.12Ta (wt%). The as-deposited LENS-RAFM steels were normalized and tempered. The microstructures of as-deposited and heat treated LENS-RAFM steels were characterized by using optical microscope (OM), scanning electron microscope (SEM) and transmission electron microscope (TEM). The tensile tests of as-deposited and heat treated samples in different directions were carried out at room temperature and 873 K. The results showed that columnar dendrites grow epitaxially along the direction of deposition in vertical section (YOZ) and a mixture of equiaxed and columnar grains appears in horizontal section (XOY). No precipitates are observed in the as-deposited sample while Cr-rich M{sub 23}C{sub 6} and Ta-rich MX type carbides appear in the heat treated sample. The as-deposited sample showed anisotropic tensile properties which could be eliminated by heat treatment. The tensile strength of the LENS-RAFM steel is similar to conventional RAFM steels such as EUROFER 97 and CLAM.

36 MATERIALS SCIENCE↗

Challenging endeavor to integrate gallium and carbon via direct bonding to evolve GaN on diamond architecture

Here this paper depicts efforts for fabricating GaN on diamond microstructure through direct bonding between Ga and C, while excluding the use of adhesive interlayer during spark plasma sintering (SPS) process. The resulting GaN on diamond architecture is seemingly successful, as suggested by macroscopic morphological observations. The microscopic inspection using high-resolution transmission electron microscopy (HRTEM), however, shows a unique, off-the-chart interlayer configuration, wherein the components are migrated, etched, or fused to tentatively form multiple crystal phases. These phases can be constructed based on their utmost stabilities among all possible phases thermodynamically driven under or near the SPS conditions.

36 MATERIALS SCIENCE↗

The effects of carbon coating on nanoripples induced by focused ion beam

The morphology and topography of self-assembled nanoripple structures on LaAlO{sub 3} (100) surface with and without carbon coating were characterized using focused ion beam (FIB)/scanning electron microscope, as well as ex situ atomic force microscopy and transmission electron microscopy. When the surface was not covered by carbon coating and had low roughness, well-ordered and highly uniform nanoripples self-assembled on the surface bombarded by FIB. In contrast, disordered nanoripples formed after carbon coating. The deposited carbon significantly influences the morphology of surface nanoripples due to its effect on the surface roughness that affect the dynamic competition between the roughening and smoothing processes. This discovery suggests a means for fabricating well-ordered and highly uniform nanoripples for nanoscale devices application.

36 MATERIALS SCIENCE↗

A compact surface decontamination system for surface-sensitive magnetic imaging

A surface decontamination system for application in surface sensitive magnetic imaging tools, such as a spin-polarized scanning electron microscope, is described. Adsorbed contaminant is chemically decomposed with the use of active oxygen in a compact vacuum chamber mounted in a microscope. The present method is especially suitable for fragile magnetic surfaces of complex oxide materials to which the conventional physical etching widely used for magnetic metals could cause serious structural damage. We have succeeded in detecting magnetic signals from a decontaminated oxide surface and visualizing domain images with sufficient magnetic contrast to analyze detailed domain structures.

36 MATERIALS SCIENCE↗

In vivo virtual intraoperative surgical photoacoustic microscopy

We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isothermal oxidation behavior of ternary Zr-Nb-Y alloys at high temperature

The effect of yttrium content on isothermal oxidation behavior of Zr-2,5%Nb-0,5%Y, Zr-2,5%Nb-1%Y Zr-2,5%Nb-1,5%Y alloy at high temperature has been studied. High temperature oxidation carried out at tube furnace in air at 600,700 and 800°C for 1 hour. Optical microscope is used for microstructure characterization of the alloy. Oxidized and un oxidized specimen was characterized by x-ray diffraction. In this study, kinetic oxidation of Zr-2,5%Nb with different Y content at high temperature has also been studied. Characterization by optical microscope showed that microstructure of Zr-Nb-Y alloys relatively unchanged and showed equiaxed microstructure. X-ray diffraction of the alloys depicted that the oxide scale formed during oxidation of zirconium alloys is monoclinic ZrO2 while unoxidised alloy showed two phase α and β phase. SEM-EDS examination shows that depletion of Zr composition took place under the oxide layer. Kinetic rate of oxidation of zirconium alloy showed that increasing oxidation temperature will increase oxidation rate but increasing yttrium content in the alloys will decrease oxidation rate.

36 MATERIALS SCIENCE↗

High temperature oxidation behavior of austenitic stainless steel AISI 304 in steam of nanofluids contain nanoparticle ZrO2

The objective of this study is to evaluate high temperature oxidation behavior of austenitic stainless steel SS 304 in steam of nanofluids contain nanoparticle ZrO{sub 2}. The oxidation was performed at high temperatures ranging from 600 to 800°C. The oxidation time was 60 minutes. After oxidation the surface of the samples was analyzed by different methods including, optical microscope, scanning electron microscope (SEM) and X-ray diffraction (XRD). X-ray diffraction examination show that the oxide scale formed during oxidation of stainless steel AISI 304 alloys is dominated by iron oxide, Fe{sub 2}O{sub 3}. Minor element such as Cr{sub 2}O{sub 3} is also appeared in the diffraction pattern. Characterization by optical microscope showed that cross section microstructure of stainless steel changed after oxidized with the oxide scale on the surface stainless steels. SEM and x-ray diffraction examination show that the oxide of ZrO{sub 2} appeared on the surface of stainless steel. Kinetic rate of oxidation of austenite stainless steel AISI 304 showed that increasing oxidation temperature and time will increase oxidation rate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Four-probe measurements with a three-probe scanning tunneling microscope

We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗