Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Combination Heat-Flux and Temperature Gage

Instrument measures both temperature and temperature gradient in confined areas. With thermopile embedded in epoxy close to thermocouple, single unit measures both temperature and heat flow. Epoxy selected for low thermal conductivity and compatibility with test environment.

Knox, E. C.↗

Solar Corona Explorer: A mission for the physical diagnosis of the solar corona

Mission objectives and spacecraft requirements for the Solar Corona Explorer (SCE), a proposed free flying, unmanned solar research craft to be tenatively launched in 1987, were defined. The SCE's purpose is to investigate structure, dynamics and evolution of the corona, globally and in the required physical detail, to study the close coupling between the inner corona and the heliosphere. Investigative objectives are: (1) to understand the corona as the source of varying interplanetary plasma and of varying solar X-ray and extreme ultraviolet fluxes; (2) to develop the capabilities to model the corona with sufficient precision to forecast the Earth's variable environment in space, on the scales from weeks to years; (3) to develop an understanding of the physical processes that determine the dynamics and physical state of the coronal plasma, particularly acceleration processes; and (4) to develop insight and test theory on the Sun applicable to stellar coronae and winds, and in particular, to understand why cool stars put such a large fraction of their energy into X-rays. Considered related factors are: (1) duration of the mission; (2) onboard measuring instrumentation; (3) ground support equipment and procedures; and (4) programs of interpretation and modeling.

Source record↗

Measurement Requirements for the Detection of Ozone Trends

The number of measurements and period of collection in order to detect a trend in the vertical distribution of ozone was studied. Specific issues considered include the impact of: (1) short term ozone variability over the measurement site, and (2) the precision of the measuring instrument on the ability to detect trends to a given confidence limit.

Frederick, J. E.↗

Seasonal and diurnal variation of the atmospheric NO2 at Syowa Station, Antarctica

Extensive attention has been directed to nitrogen dioxide (NO2) since its important role in the atmospheric chemistry relating to the stratospheric ozone (e.g., WMO, 1982) has been pointed out. However, the behavior of NO2 in the atmosphere has still not been fully confirmed, although ground-based, balloon and satellite measurements of NO2 have been reported by many scientists. Especially, only a few measurements made at high latitude in the Southern Hemisphere have been reported. The total atmospheric NO2 by ground-based visible absorption spectroscopy at Syowa Station (69 deg S, 39.6 deg E), Antarctica. The observation continued from March 1983, to January 1984. The principles of measurement, instrumentation and the method of data analysis are described in detail.

Shibasaki, K.↗

Element distribution and noble gas isotopic abundances in lunar meteorite Allan Hills A81005

Antarctic meteorite ALLAN HILLS A81005, an anorthositic breccia, is recognized to be of lunar origin. The noble gases in this meteorite were analyzed and found to be solar-wind implanted gases, whose absolute and relative concentrations are quite similar to those in lunar regolith samples. A sample of this meteorite was obtained for the analysis of the noble gas isotopes, including Kr(81), and for the determination of the elemental abundances. In order to better determine the volume derived from the surface correlated gases, grain size fractions were prepared. The results of the instrumental measurements of the gamma radiation are listed. From the amounts of cosmic ray produced noble gases and respective production rates, the lunar surface residence times were calculated. It was concluded that the lunar surface time is about half a billion years.

Kraehenbuehl, U.↗

Current-driven plasma instabilities and auroral-type particle acceleration at Venus

Above the ionosphere of Venus, several instruments on the Pioneer Orbiter detect correlated wave, field and particle phenomena suggestive of current-driven anomalous resistivity and auroral-type particle acceleration. In localized regions the plasma wave instrument measures intense mid-frequency turbulence levels together with strong field-aligned currents. Here the local parameters indicate that there is marginal stability for ion acoustic waves, and the electron temperature probe finds evidence that energetic primaries are present. This suggests an auroral-type energy deposition into the upper atmosphere of Venus. These results appear to be consistent with the direct measurements of auroral emissions from the Pioneer-Venus ultraviolet imaging spectrometer.

Scarf, F. L.↗

Biogeochemical cycling in terrestrial ecosystems - Modeling, measurement, and remote sensing

The use of modeling, remote sensing, and measurements to characterize the pathways and to measure the rate of biogeochemical cycling in forest ecosystems is described. The application of the process-level model to predict processes in intact forests and ecosystems response to disturbance is examined. The selection of research areas from contrasting climate regimes and sites having a fertility gradient in that regime is discussed, and the sites studied are listed. The use of remote sensing in determining leaf area index and canopy biochemistry is analyzed. Nitrous oxide emission is investigated by using a gas measurement instrument. Future research projects, which include studying the influence of changes on nutrient cycling in ecosystems and the effect of pollutants on the ecosystems, are discussed.

Peterson, D. L.↗

Noncoherent sampling technique for communications parameter estimations

This paper presents a method of noncoherent demodulation of the PSK signal for signal distortion analysis at the RF interface. The received RF signal is downconverted and noncoherently sampled for further off-line processing. Any mismatch in phase and frequency is then compensated for by the software using the estimation techniques to extract the baseband waveform, which is needed in measuring various signal parameters. In this way, various kinds of modulated signals can be treated uniformly, independent of modulation format, and additional distortions introduced by the receiver or the hardware measurement instruments can thus be eliminated. Quantization errors incurred by digital sampling and ensuing software manipulations are analyzed and related numerical results are presented also.

Su, Y. T.↗

Unified constitutive materials model development and evaluation for high-temperature structural analysis applications

Unified constitutive material models were developed for structural analyses of aircraft gas turbine engine hot section components with particular application to an isotropic material used for combustor liners. Differential forms of models independently developed were considered in this study. These models combine the interactions of time-dependent (creep) and time-independent (plasticity) inelastic behavior of a material. Predicted stress-strain responses from these models were evaluated against cyclic isothermal and nonisothermal test results for uniaxial specimens of a nickel-base superalloy. The unified models were implemented in a nonlinear structural analysis code. Two unique NASA Lewis test facilities were used in the evaluation of the models for complex geometry specimens and evaluation of advanced temperature and high-temperature strain measurement instrumentation. Predicted nonlinear structural responses from one of the models for a flat plate and a segment of a conventional combustor liner are presented.

Thompson, R. L.↗

Water-Cooled Optical Thermometer

Water-cooled optical probe measures temperature of nearby radiating object. Intended primarily for use in silicon-growing furnace for measuring and controlling temperatures of silicon ribbon, meniscus, cartridge surfaces, heaters, or other parts. Cooling water and flushing gas cool fiber-optic probe and keep it clean. Fiber passes thermal radiation from observed surface to measuring instrument.

Menna, A. A.↗

High temperature stress-strain analysis

The objectives are threefold: to assist in developing predictive tools needed to improve design analyses and procedures for the efficient and accurate prediction of burner liner structural performance and response; to calibrate, validate, and evaluate these predictive tools by comparing the predicted results with the experimental data; and to evaluate existing as well as advanced temperature and strain measurement instrumentation, through both contact and noncontact efforts, in a simulated turbine engine combustor environment. As the predictive tool, tests, test methods, instrumentation, and data acquisition and reduction methods are developed and evaluated, a proven, integrated analysis/experiment method will be developed that will permit the accurate prediction of the cyclic life of a burner liner.

Thompson, R. L.↗

Effects of non-spherical drops on a phase Doppler spray analyzer

A phase/Doppler spray analyzer (P/DSA) and a laser imaging system was used to study the response of a P/DSA to nonspherical particles. Methanol particles with an aspect ratio ranging from 0.7 to 1.4 were used in this investigation. Results indicated that the P/DSA was quite sensitive to particle shape. A Berglund-Liu generator was used to produce particles of 98 microns (volumetric diameter). The P/DSA instrument measured particle sizes ranging from 142 microns for a particle of aspect ratio 0.7, to 84 microns for an aspect ratio of 1.4. Particle diameters based on averaged x and y diameters for the laser imaging system ranged from 95 microns to 92 microns over the same range of aspect ratios.

Alexander, D. R.↗

High temperature stress-strain analysis

The objectives of the high temperature structures program are threefold: to assist in the development of analytical tools needed to improve design analysis and procedures for the efficient and accurate prediction of the nonlinear structural response of hot-section components; to aid in the calibration, validation, and evaluation of the analytical tools by comparing predictions with experimental data; and to evaluate existing as well as advanced temperature and strain measurement instrumentation.

Thompson, Robert L.↗

Measurement of micro-roughness and effects of detector bandwidth and finite width

Surface micro-roughness of grazing incidence optics has long been recognized as a critical parameter in the control of the scattered X-ray intensity and its effects on the point spread function half-energy width. Accurate knowledge of the amplitude of surface micro-roughness is vital to assess optic predicted performance during the final stages of fabrication. This requires not only a knowledge of the spatial bandwidth over which surface features must be measured, but also knowledge of the bandwidth of the measurement instrument. We show that the standard assumption that instruments respond up to their Nyquist limit is an oversimplification which neglects the finite detector size and its bandwidth limiting effects when sampling a real (i.e., two-dimensional) surface.

Reid, P. B.↗

High temperature stress-strain analysis

The objectives of the high-temperature structures program are threefold: to assist in the development of analytical tools needed to improve design analyses and procedures for the efficient and accurate prediction of the nonlinear structural response of hot-section components; to aid in the calibration, validation, and evaluation of the analytical tools by comparing predictions with experimental data; and to evaluate existing as well as advanced temperature and strain measurement instrumentation. As the analytical tools, test methods, tests, instrumentations, as well as data acquisition, management, and analysis methods are developed and evaluated, a proven, integrated analysis and experiment method will result in a more accurate prediction of the cyclic life of hot section components.

Thompson, Robert L.↗

Mapping of auroral kilometric radiation sources to the aurora

Auroral kilometric radiation (AKR) and optical auroral emissions are observed simultaneously using plasma wave instrumentation and auroral imaging photometers carried on the DE 1 spacecraft. The DE 1 plasma wave instrument measures the relative phase of signals from orthogonal electric dipole antennas, and from these measurements, apparent source directions can be determined with a high degree of precision. Wave data are analyzed for several strong AKR events, and source directions are determined for several emission frequencies. By assuming that the AKR originates at cyclotron resonant altitudes, a candidate source field line is identified. When the selected source field line is traced down to auroral altitudes on the concurrent DE 1 auroral image, a striking correspondece between the AKR source field line and localized auroral features is produced. The magnetic mapping study provides strong evidence that AKR sources occur on field lines associated with discrete auroral arcs, and it provides confirmation that AKR is generated near the electron cyclotron frequency.

Huff, R. L.↗

Spacelab Life Sciences 1 - The stepping stone

The Spacelab Life Sciences (SLS-1) mission scheduled for launch in March 1990 will study the effects of microgravity on physiological parameters of humans and animals. The data obtained will guide equipment design, performance of activities involving the use of animals, and prediction of human physiological responses during long-term microgravity exposure. The experiments planned for the SLS-1 mission include a particulate-containment demonstration test, integrated rodent experiments, jellyfish experiments, and validation of the small-mass measuring instrument. The design and operation of the Research Animal Holding Facility, General-Purpose Work Station, General-Purpose Transfer Unit, and Animal Enclosure Module are discussed and illustrated with drawings and diagrams.

Dalton, B. P.↗