Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MUONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Latest results of the Muon g-2 experiment at Fermilab

The muon magnetic anomaly, aμ = g - 2/ 2, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. The Muon g − 2 experiment at Fermilab aims to measure aμ with a final accuracy of 140 parts per billion (ppb). The experiment is based on the measurement of the muon spin anomalous precession frequency, ωa, in a magnetic field. The first result of the experiment, based on the 2018 data-taking campaign, was published in 2021 and it confirmed the previous result obtained at Brookhaven National Laboratory with a similar sensitivity of 460 ppb. In this proceeding, the result based on the 2019 and 2020 datasets is presented and the improvement in the accuracy with respect to the 2018 dataset are discussed.

Sorbara, Matteo [INFN, Rome2; Rome U., Tor Vergata↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

The Reconstruction Software for the Muon Ionization Cooling Experiment Trackers

The international Muon Ionisation Cooling Experiment (MICE) is designed to demonstrate the principle of muon ionization cooling, for application to a future Neutrino Factory or Muon Collider. In order to measure the change in emittance, MICE is equipped with a pair of high precision scintillating fibre trackers. The trackers are required to measure a 10% change in emittance to 1% accuracy (giving an overall precision of 0.1%). This paper describes the tracker reconstruction software, as a part of the overall MICE software framework, MAUS. Channel clustering is described, proceeding to the formation of space-points, which are then associated with particle tracks using pattern recognition algorithms. Finally a full custom Kalman track fit is performed, to account for energy loss and multiple scattering. Exemplar results are shown for Monte Carlo data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light from cosmic-ray muons in liquid argon

This paper reports the results of an experiment to directly measure the time-resolved scintillation signal from the passage of cosmic-ray muons through liquid argon. Scintillation light from these muons is of value to studies of weakly-interacting particles in neutrino experiments and dark matter searches. The experiment was carried out at the TallBo dewar facility at Fermilab using prototype light guide detectors and electronics developed for the Deep Underground Neutrino Experiment. Two models are presented for the time structure of the scintillation light, a phenomenological model and a physically-motivated model. Both models find tT = 1:52 ms for the decay time constant of the Ar 2 triplet state. These models also show that the identification of the “early” light fraction in the phenomenological model, FE 25% of the signal, with the total light from singlet decays is an underestimate. The total fraction of singlet light is FS 36%, where the increase over FE is from singlet light emitted by the wavelength shifter through processes with long decay constants. The models were further used to compute the experimental particle identification parameter Fprompt, the fraction of light coming in a short time window after the trigger compared with the light in the total recorded waveform. The models reproduce quite well the typical experimental value 0.3 found by dark matter and double b-decay experiments, which suggests this parameter provides a robust metric for discriminating electrons and muons from more heavily ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Racetrack FFAG muon decay ring for nuSTORM with triplet focusing

The neutrino beam produced from muons decaying in a storage ring would be an ideal tool for precise neutrino cross section measurements and the search for sterile neutrinos due to its precisely known flavour content and spectrum. In the proposed nuSTORM facility, pions would be directly injected into a racetrack storage ring, where the circulating muon beam would be captured. In this paper we show that a muon decay ring based on a racetrack scaling FFAG (Fixed Field Alternating Gradient) with triplet focusing structures is a very promising option with potential advantages over the FODO based solution. Finally, we discuss the ring concept, machine parameters, linear optics design, beam dynamics and the injection system.

43 PARTICLE ACCELERATORS↗

The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics integration for the GE2/1 and ME0 GEM detector systems for the CMS phase-2 muon system upgrade

Abstract The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-gas electron multiplier detector, which has recently entered the mass production phase, and the ME0 triple-GEM detector system, which is in the late prototyping phase, are undergoing electronics integration. These proceedings briefly discuss the frontend electronics for the GE2/1 and ME0 detector systems, the electronics integration testing process, and the future plans for the frontend electronics of these two detector systems by the CMS GEM collaboration.

Instruments & Instrumentation↗

The potential of a TeV-scale muon-ion collider

We propose the development of a novel muon-proton and muon-nucleus collider facility at the TeV scale that is capable of performing precision deep inelastic scattering measurements in new regimes and providing a rich program in nuclear and particle physics. Such a facility could seed, or leverage, the development of a muon-antimuon collider and make use of the existing hadron accelerator infrastructure when sited at a facility such as Brookhaven National Laboratory, Fermilab, or CERN. Here, we discuss the possible energy and luminosity design parameters for several collider configurations, and illustrate the science potential with several studies on deep inelastic scattering kinematics, Higgs and vector boson production, top quark production, and beyond Standard Model leptoquark production. Detector design considerations and a possible road map toward development are also given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector

ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam line directly upstream of the MINOS Near Detector from September 2009 to February 2010, during which thousands of neutrino and antineutrino events were collected. The MINOS Near Detector was used to measure muons downstream of ArgoNeuT. Though ArgoNeuT is primarily an R&D project, the data collected provide a unique opportunity to measure neutrino cross sections in the 0.1-10 GeV energy range. Fully reconstructing the muon from these interactions is imperative for these measurements. This paper focuses on the complete kinematic reconstruction of neutrino-induced through-going muons tracks. Analysis of this high statistics sample of minimum ionizing tracks demonstrates the reliability of the geometric and calorimetric reconstruction in the ArgoNeuT detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for 𝑏-hadron decays to long-lived particles in the CMS endcap muon detectors

A search for long-lived particles originating from the decay of 𝑏 hadrons produced in proton-proton collisions with a center-of-mass energy of 13 TeV at the LHC is presented. The analysis is performed on a dataset recorded in 2018, corresponding to an integrated luminosity of 41.6 fb −1 . Interactions of the long-lived particles in the CMS endcap muon system would create hadronic or electromagnetic showers, producing clusters of detector hits. Selected events contain at least one such high-multiplicity cluster in the muon endcaps and require the presence of a displaced muon. The most stringent upper limits to date on the branching fraction ℬ⁡(𝐵 →𝐾⁢Φ), where the long-lived particle Φ decays to a pair of hadrons, are obtained for Φ masses of 0.3–3.0 GeV and Φ mean proper decay lengths in the range of 1–500 cm.

Hayrapetyan, A. [Yerevan Physics Institute]↗

Measurement of muon neutrino induced charged current interactions without charged pions in the final state using a new T2K off-axis near detector WAGASCI-BabyMIND

We report a flux-integrated cross section measurement of muon neutrino interactions on water and hydrocarbon via charged current reactions without charged pions in the final state with the WAGASCI-BabyMIND detector, which was installed in the T2K near detector hall in 2018. The detector is located 1.5° off-axis and is exposed to a more energetic neutrino flux than ND280, another T2K near detector, which is located at a different off-axis position. The total flux-integrated cross section is measured to be 1.26 ± 0.18⁢(stat+syst) × 10 −39 cm 2 /nucleon on CH and 1.44 ± 0.21⁢(stat+syst) × 10 −39 cm 2 /nucleon on H 2 ⁡O. These results are compared to model predictions provided by the neut v5.3.2 and genie v2.8.0 Monte Carlo generators and the measurements are compatible with these models. Differential cross sections in muon momentum and cosine of the muon scattering angle are also reported. This is the first such measurement reported with the WAGASCI-BabyMIND detector and utilizes the 2020 and 2021 datasets.

lepton-hadron interactions↗

Characterization of muon and electron beams in the Paul Scherrer Institute PiM1 channel for the MUSE experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the π/μ/e beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the intermediate focal plane and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. Finally, we conclude that the PiM1 channel can be used for high precision π, μ, and e scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diphoton signals of muon-philic scalars at DarkQuest

We analyze the capability of the DarkQuest proton beam-dump experiment at Fermilab to discover new light resonances decaying into photons. As an example model, we focus on muon-philic scalar particles that decay to photons. This is one of the few minimal models that can address the ( g − 2 ) μ anomaly at low mass. These scalars can be copiously produced by meson decays and muon bremsstrahlung. We point out that thanks to DarkQuest’s compact geometry, muons can propagate through the dump and efficiently produce dark scalars near the end of the dump. This mechanism enables DarkQuest to be sensitive to both long-lived and prompt scalars. At the same time, diphoton signatures are generically not background free, and we discuss in detail the different sources of background and strategies to mitigate them. We find that the backgrounds can be sufficiently reduced for DarkQuest to test currently viable ( g − 2 ) μ parameter space. Published by the American Physical Society 2024

Blinov, Nikita (ORCID:000000022845961X)↗

Neutrino-portal dark matter detection prospects at a future muon collider

With no concrete evidence for nongravitational interactions of dark matter to date, it is natural to wonder whether dark matter couples predominantly to the Standard Model (SM)’s neutrinos. Neutrino interactions (and the possible existence of additional neutrinophilic mediators) are substantially less understood than those of other SM particles, yet this picture will change dramatically in the coming decades with new neutrino sources. One potential new source arises with the construction of a high-energy muon collider (MuCol); due to muons’ instability, a MuCol is a source of high-energy collimated neutrinos. Importantly, since the physics of muon decays (into neutrinos) is very well-understood, this leads to a neutrino flux with systematic uncertainties far smaller than fluxes from conventional high-energy (proton-sourced) neutrino beams. In this work, we study the capabilities of a potential neutrino detector, “ MuCol ν ”, placed ∼ 100 m downstream of the MuCol interaction point. The MuCol ν detector would be especially capable of searching for a neutrinophilic mediator ϕ through the mononeutrino scattering process ν μ N → μ + ϕ X , exceeding searches from other terrestrial approaches for m ϕ in the ∼ few MeV- ten GeV range. Even with a 10 kg-yr exposure, MuCol ν is capable of searching for well-motivated classes of thermal freeze-out and freeze-in neutrino-portal dark matter. Published by the American Physical Society 2025

Adhikary, Jyotismita (ORCID:0000000253894170)↗

Search for the Higgs Boson Decaying to Two Muons in Proton-Proton Collisions at s = 13 TeV

Here, a search for the Higgs boson decaying to two oppositely charged muons is presented using data recorded by the CMS experiment at the CERN LHC in 2016 at a center-of-mass energy √s = 13 TeV, corresponding to an integrated luminosity of 35.9 fb -1 . Data are found to be compatible with the predicted background. For a Higgs boson with a mass of 125.09 GeV, the 95% confidence level observed (background-only expected) upper limit on the production cross section times the branching fraction to a pair of muons is found to be 3.0 (2.5) times the standard model expectation. In combination with data recorded at center-of-mass energies √s=7 and 8 TeV, the background-only expected upper limit improves to 2.2 times the standard model value with a standard model expected significance of 1.0 standard deviation. The corresponding observed upper limit is 2.9 with an observed significance of 0.9 standard deviation. This corresponds to an observed upper limit on the standard model Higgs boson branching fraction to muons of 6.4×10 -4 and to an observed signal strength of 1.0 ± 1.0(stat) ± 0.1(syst).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual Designs of Dipole Magnet for Muon Collider Storage Ring

Conceptual designs of a superconducting dipole magnet for a storage ring of a muon collider with a 1.5 TeV center of mass (c.o.m.) energy and an average luminosity of 10 34 cm -2 s -1 are presented. In contrast to proton machines, the dipoles for the muon collider should be able to handle ~0.5 kW/m of dynamic heat load from the muon beam decays. The magnets are based on Nb 3 Sn superconductor and designed to provide an operating field of 10 T in the 20-mm aperture with the critical current margin required for reliable machine operation. The magnet cross-sections were optimized to achieve the best possible field quality in the aperture occupied by beams. The developed mechanical structures provide adequate coil prestress and support at the maximum level of Lorentz forces in the coil. Magnet parameters are reported and compared with the requirements.

43 PARTICLE ACCELERATORS↗