Genomic and proteomic biases inform metabolic engineering strategies for anaerobic fungi
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Intensity-modulated radiation therapy (IMRT) is becoming the treatment of choice for many head and neck cancer patients. IMRT reduces some toxicities by reducing radiation dose to uninvolved normal tissue near tumor targets; however, other tissues not irradiated using previous 3D techniques may receive clinically significant doses, causing undesirable side effects including nausea and vomiting (NV). Irradiation of the brainstem, and more specifically, the area postrema and dorsal vagal complex (DVC), has been linked to NV. We previously reported preliminary hypothesis-generating dose effects associated with NV in IMRT patients. The goal of this study is to relate brainstem dose to NV symptoms. We retrospectively studied 100 consecutive patients that were treated for oropharyngeal cancer with IMRT. We contoured the brainstem, area postrema, and DVC with the assistance of an expert diagnostic neuroradiologist. We correlated dosimetry for the 3 areas contoured with weekly NV rates during IMRT. NV rates were significantly higher for patients who received concurrent chemotherapy. Post hoc analysis demonstrated that chemoradiation cases exhibited a trend towards the same dose-response relationship with both brainstem mean dose (p = 0.0025) and area postrema mean dose (p = 0.004); however, both failed to meet statistical significance at the p {<=} 0.002 level. Duration of toxicity was also greater for chemoradiation patients, who averaged 3.3 weeks with reported Common Terminology Criteria for Adverse Events (CTC-AE), compared with an average of 2 weeks for definitive RT patients (p = 0.002). For definitive RT cases, no dose-response trend could be ascertained. The mean brainstem dose emerged as a key parameter of interest; however, no one dose parameter (mean/median/EUD) best correlated with NV. This study does not address extraneous factors that would affect NV incidence, including the use of antiemetics, nor chemotherapy dose schedule specifics before and during RT. A prospective study will be required to depict exactly how IMRT dose affects NV.
ABSTRACT: Burnout and compassion fatigue (CF) adversely affect medical professionals, including those employed in radiation oncology. Previously conducted research acknowledged the presence of burnout in populations of radiation therapists, radiation oncologists, and oncology nursing staff. The aim of the following research was to measure the incidence of burnout or CF in the specific population of medical dosimetrists surveyed. As professional members of the radiation oncology team, this group had not been included in published research data to date. The hypothesis of the subsequent study stated that a comparable incidence of burnout would be observed among medical dosimetrists as had been reported by earlier researchers for a population of radiation therapists. A survey tool based on the Maslach Burnout Inventory (MBI) and distributed to full members of the American Association of Medical Dosimetrists (AAMD) was utilized as the research measurement method. Results obtained indicated an incidence rates of burnout or CF for medical dosimetrists were less than the rates previously measured for radiation therapists (53% vs 11% for emotional exhaustion [EE] and 45% vs 27% for depersonalization [DP]). The incidence of burnout was based on the Burnout Inventory (BI) developed for the research project. Each of the subscales, EE, DP, and decreased personal accomplishment (PA), was considered and analyzed independently. Although not as prevalent among medical dosimetrists as a variety of additional radiation oncology professionals, a significant portion of the population demonstrated signs of burnout or CF. Future concerns abound for the population of medical dosimetrists as a large number of members scored positive for intermediate risk of burnout and CF. Additionally, a large portion of the population was found to be rapidly approaching retirement.
The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam's central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued.
Stereotactic body radiation therapy (SBRT) delivers a high biologically effective dose while minimizing toxicities to surrounding tissues. Within the scope of clinical trials and local practice, there are inconsistencies in dosimetrics used to evaluate plan quality. The purpose of this critical review was to determine if dosimetric parameters used in SBRT plans have an effect on local control (LC), overall survival (OS), and toxicities. A database of relevant trials investigating SBRT for patients with early-stage non–small cell lung cancer was compiled, and a table of dosimetric variables used was created. These parameters were compared and contrasted for LC, OS, and toxicities. Dosimetric end points appear to have no effect on OS or LC. Incidences of rib fractures correlate with a lack of dose-volume constraints (DVCs) reported. This review highlights the great disparity present in clinical trials reporting dosimetrics, DVCs, and toxicities for lung SBRT. Further evidence is required before standard DVCs guidelines can be introduced. Dosimetric end points specific to stereotactic treatment planning have been proposed but require further investigation before clinical implementation.
With margin reduction common in head and neck radiotherapy, it is critical that the dosimetric effects of setup deviations are quantified. With past studies focusing on the quantification of positional and volumetric changes of organs at risk (OARs), this study aimed to measure the dose delivered to these the parotid gland (PG) and pharyngeal constrictor muscles (PCMs) using cone beam computed tomography (CBCT). Furthermore, this investigation sought to establish a potential time trend of change in dose delivered to target volumes secondary to ascertaining the need for daily image guidance (IG) to reduce the dose burden to these important OARs. Intensity modulated radiotherapy (IMRT) plans for 5 locally advanced head and neck patients' plans were created and mapped to weekly CBCTs. Each plan was recalculated without heterogeneity correction allowing for dosimetric comparison. Dosimetric endpoints recorded to assess the effect of positional variation were as per ICRU 83 and included D{sub 95} and D{sub 98} for the target volumes, mean dose (MD) and V{sub 30} {sub Gy} for the PGs, and V{sub 50} {sub Gy} and MD for the PCMs. Results were deemed statistically significant if p < 0.05. No significant time trends were established for these OARs. A significant decrease in V{sub 50} {sub Gy} was observed for all PCMs (p < 0.001) on all CBCTs relative to the original plan. Regarding target volumes, a highly significant decrease in MD (MD = 20 Gy, CI: −20.310 to −19.820) in D{sub 98} of the high-dose planning target volume (PTV [70 Gy]; PTVD{sub 98%} = 70 Gy) for case 3 was found (p ≤ 0.001). A nonpredictable, yet significant dosimetric effect was found. A clinically acceptable balance must be achieved between OAR dosimetry and target coverage as can be achieved by frequent IG.
The International Commission on Radiation Units & Measurements -83 recommends prescribing intensity-modulated radiation therapy (IMRT) in a dose-volume manner. Despite this, clinical variation still exists in how prostate IMRT plans are prescribed. This study aims to investigate the impact of different plan normalization methods for postprostatectomy IMRT. IMRT treatment plans were created retrospectively for 20 postprostatectomy patients. These were normalized such that the dose received by 98% (D98) of the planning target volume (PTV) was equal to 100% of the prescribed dose. All plans were individually optimized to achieve target coverage and organ at risk (OAR) dose constraints. Each patient's plan was then copied and normalized such that the mean dose (Dmean) received by the PTV was equal to 100% of the prescribed dose. The International Commission on Radiation Units & Measurements -83 recommended dosimetric end points were extracted for targets and Quantitative Analyses of Normal Tissue Effects in the Clinic or Radiation Therapy Oncology Group 0534 end points extracted for OARs. Statistical analysis using the Wilcoxon signed-rank test to measure the difference between data from plans normalized to D98 and Dmean was conducted. Extracted dosimetric end points of the targets and OARs were significantly higher in plans normalized to D98 than Dmean (p Normalization impacts on dosimetric end points of a plan. Hence, reporting the normalization method used is necessary to allow for meaningful interpretation of IMRT dosimetric studies.
A critical analysis comparing the diffusion selectivity, solubility selectivity, diffusivity, and solubility coefficients of thermally rearranged (TR) polymers and polymers of intrinsic microporosity (PIM), two types of polymers which consistently perform at or beyond the polymer upper bound for certain gas pairs (O 2 /N 2 and CO 2 /CH 4 ), is reported in this paper. Although most polymers in these two classes exhibit transport properties in the range of typical glassy polymers, several variants offer exceptional performance. The diffusivity selectivity for O 2 /N 2 and CO 2 /CH 4 for TR polymers and PIM lies outside the range of the glassy polymer database. The solubility coefficients for O 2 are at the upper end of the range of both TR and PIM polymers, as is also the case for CO 2 solubility coefficients for PIM polymers. The O 2 /N 2 and CO 2 /CH 4 solubility selectivities for both PIM and TR polymers are in the range of typical glassy polymers. Thus, unique separation values for these polymers are a manifestation of maximizing diffusivity selectivity combined with very high gas solubility. Additionally, the previously determined diffusion gas kinetic diameters, d g , were found to correlate best with diffusion coefficients of PIM and TR polymers and serve to better analyze transport properties of upper bound materials.
A method is described to discriminate between live and dead cells of the infectious fungi Aspergillus fumigatus, Aspergillus flavus, Aspergillus terreus, Mucor racemosus, Rhizopus stolonifer and Paecilomyces variotii. To test the method, conidial suspensions were heat inactivated at 85 °C or held at 5 °C (controls) for 1 h. Polycarbonate filters (25 mm diameter, 0.8 μm pore size) were placed on "welled" slides (14 mm diameter) and the filters treated with either PBS or PMA. Propidium monoazide (PMA), which enters dead cells but not live cells, was incubated with cell suspensions, exposed to blue wavelength light-emitting diodes (LED) to inactivate remaining PMA and secure intercalation of PMAwith DNA of dead cells. Treated cells were extracted and the live and dead cells evaluated with quantitative PCR (QPCR). After heat treatment and DNA modification with PMA, all fungal species tested showed an approximate 100- to 1000-fold difference in cell viability estimated by QPCR analysis which was consistent with estimates of viability based on culturing.
Abstract not provided
In Arabidopsis, RNA-dependent DNA methylation and transcriptional silencing involves three nuclear RNA polymerases that are biochemically undefined: the presumptive DNA-dependent RNA polymerases, Pol IV and Pol V and the putative RNA-dependent RNA polymerase, RDR2. Here, we demonstrate their RNA polymerase activities in vitro. Unlike Pol II, Pols IV and V require an RNA primer, are insensitive to alpha-amanitin and differ in their ability to displace non-template DNA during transcription. Biogenesis of 24 nt small interfering RNAs (siRNAs) requires both Pol IV and RDR2, which physically associate in vivo. Pol IV does not require RDR2 for activity, but RDR2 is nonfunctional in the absence of associated Pol IV, suggesting that their coupling explains the channeling of Pol IV transcripts into double-stranded RNAs that are then diced into 24 nt siRNAs.
N/A
Ultrathin solar cells reduce material usage and allow the use of lower-quality materials thanks to their one order of magnitude smaller thickness than their conventional counterparts. However, efficient photonic light-trapping is required to harvest the incident light efficiently for an otherwise insufficient absorber thickness. Quasi-random photonic crystals are predicted to have high efficient light-trapping while being more robust under angle and thickness variations than simple photonic crystals. In this study, we experimentally demonstrate a light-trapping solution based on quasi-random photonic crystals fabricated by polymer blend lithography. We control the average lattice parameter by modifying the spin-coating speed. We demonstrate an ultrathin GaAs cell of 260 nm with a rear quasi-random pattern with submicron features, and a J sc = 26.4 mA/cm 2 and an efficiency of 22.35% under the global solar spectrum.
Not Available
Jefferson Lab operates a pair of oscillator-based continuous-wave Free Electron Lasers (FELs) as a linac-based next generation light source with pulse repetition rates up to 75 MHz. The facility uses an energy recovered linac design for efficiency of operation. Recent advances in superconducting technology have been implemented to produce higher acceleration gradients in the linac to produce higher electron beam energies that result in higher photon energies. Thus, while the system originally operated only in the IR, it now covers the photon energy range from the UV to THz, with harmonics upwards of 10 eV with an average spectral flux that is calculated to be 5x10 17 photons/sec/0.1%BW. Pulse lengths are in the sub-picosecond regime, and the fully coherent nature of the source, both transversely and longitudinally, results in peak and average brightness values that are several orders of magnitude higher than storage rings. The system provides an R&D test-bed for studies of electron beam dynamics in a regime appropriate for next generation light sources operating at MHz repetition rates.
We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.
We measure the distribution of energy deposited in a 40 × 88 mm plastic scintillator by e + e – pair production of 4.44 MeV γ-rays. He, we observe the double-escape peak of 3.42 MeV from pair production by tagging 511 keV annihilation radiation in two high-Z scintillators. The source is a standard commercial neutron source using α-emitting 241 Am encapsulated with 9 Be, which has a reaction branch feeding the first I π = 2 + state of 12 C making the 4.44 MeV γ-rays. We demonstrate the extraction of the double-escape peak from the large neutron-produced backgound, and explore some of the features and difficulties of this technique with our apparatus.
The Los Alamos Isotope Production Facility (IPF) creates medical isotopes using a proton beam impinged on a target stack. Spallation neutrons are created in the interaction of the beam with target. The use of these spallation neutrons to produce additional radionuclides has been proposed in this paper. However, the energy distribution and magnitude of the flux is not well understood. Finally, a modified SAND-II spectral adjustment routine has been used with radioactivation foils to determine the differential neutron fluence for these spallation neutrons during a standard IPF production run.