Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASURING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Measurement of the B s 0 Lifetime in Fully and Partially Reconstructed B s 0 →D s - (Φπ⁻)X Decays in pp̄ Collisions at √s=1.96 TeV

We present a measurement of the BB s 0 lifetime in fully and partially reconstructed B s 0 →D s - (Φπ⁻)X decays in 1.3 fb⁻¹ collected in pp̄ collisions at √s=1.96 TeV by the CDF II detector at the Fermilab Tevatron. We measure τ(B s 0 )=1.518±0.041(stat)±0.027(syst) ps. The ratio of this result and the world average B⁰ lifetime yields τ(B s 0 )/τ(B⁰)=0.99±0.03, which is in agreement with recent theoretical predictions.

Aaltonen, T.↗

Measurements of WW and WZ Production in W+jets Final States in pp̄ Collisions

We study WW and WZ production with lνqq (l=e,μ) final states using data collected by the D0 detector at the Fermilab Tevatron Collider corresponding to 4.3 fb⁻¹ of integrated luminosity from pp̄ collisions at √s=1.96 TeV. Assuming the ratio between the production cross sections σ(WW) and σ(WZ) as predicted by the standard model, we measure the total WV (V=W,Z) cross section to be σ(WV)=19.6 +3.2 -3.0 pb and reject the background-only hypothesis at a level of 7.9 standard deviations. We also use b-jet discrimination to separate the WZ component from the dominant WW component. Simultaneously fitting WW and WZ contributions, we measure σ(WW)=15.9 +3.7 -3.2 pb and σ(WZ)=3.3 +4.1 -3.3 pb, which is consistent with the standard model predictions.

Abazov, V. M.↗

Measurement of the τ -lepton Lifetime at Belle

We report that the lifetime of the τ lepton is measured using the process e + e - → τ + τ - , where both τ leptons decay to 3 π ν τ . The result for the mean lifetime, based on 711 fb - 1 of data collected with the Belle detector at the Y ( 4 S ) resonance and 60 MeV below, is τ = ( 290 . 17 ± 0.53 ( stat ) ± 0.33 ( syst ) ) × 10 - 15 s . The first measurement of the lifetime difference between τ + and τ - is performed. The upper limit on the relative lifetime difference between positive and negative τ leptons is | Δ τ | / τ < 7.0 × 10 - 3 at 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Branching Fraction B ( Λ c + → p K - π + )

In this work, we present the first model-independent measurement of the absolute branching fraction of the Λ c + → p K - π + decay using a data sample of 978 fb - 1 collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. The number of Λ c + baryons is determined by reconstructing the recoiling D ( * ) - p ¯ π + system in events of the type e + e - → D ( * ) - p ¯ π + Λ c + . Lastly, the branching fraction is measured to be B ( Λ c + → p K - π + ) = ( 6.84 ± 0.24 - 0.27 + 0.21 ) % , where the first and second uncertainties are statistical and systematic, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the $B_s^0$ Lifetime in the Flavor-Specific Decay Channel $B_s^0 \to D_s^- \mu^+\nu X$

We present an updated measurement of the B s 0 lifetime using the semileptonic decays B s 0 → D s - μ + ν X , with D s - → ϕ π - and ϕ → K + K - (and the charge conjugate process). This measurement uses the full Tevatron Run II sample of proton-antiproton collisions at s = 1.96 TeV , comprising an integrated luminosity of 10.4 fb − 1 . We find a flavor-specific lifetime τ fs ( B s 0 ) = 1.479 ± 0.010 ( stat ) ± 0.021 ( syst ) ps . This technique is also used to determine the B 0 lifetime using the analogous B 0 → D - μ + ν X decay with D - → ϕ π - and ϕ → K + K - , yielding τ ( B 0 ) = 1.534 ± 0.019 ( stat ) ± 0.021 ( syst ) ps . Both measurements are consistent with the current world averages, and the B s 0 lifetime measurement is one of the most precise to date. Taking advantage of the cancellation of systematic uncertainties, we determine the lifetime ratio τ fs ( B s 0 ) / τ ( B 0 ) = 0.964 ± 0.013 ( stat ) ± 0.007 ( syst ) .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the direct CP asymmetry in B¯->Xs+dy decays with a lepton tag

We report the measurement of the direct CP asymmetry in the radiative B¯?Xs+d? decay using a data sample of (772±11)×106 BB¯ pairs collected at the ?(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The CP asymmetry is measured as a function of the photon energy threshold. For E*?=2.1 GeV, where E*? is the photon energy in the center-of-mass frame, we obtain ACP(B¯?Xs+d?)=(2.2±3.9±0.9)%, consistent with the Standard Model prediction.

Pesantez, L↗

First Observation of the Hadronic Transition Υ ( 4 S ) → η h b ( 1 P ) and New Measurement of the h b ( 1 P ) and η b ( 1 S ) Parameters

Using a sample of 771.6 × 10 6 Υ Υ ( 4 S ) decays collected by the Belle experiment at the KEKB e + e - collider, we observe, for the first time, the transition Υ ( 4 S ) → η h b ( 1 P ) with the branching fraction B [ Υ ( 4 S ) → η h b ( 1 P ) ] = ( 2.18 ± 0.11 ± 0.18 ) × 10 - 3 and we measure the h b ( 1 P ) mass M h b ( 1 P ) = ( 9899.3 ± 0.4 ± 1.0 ) MeV / c 2 , corresponding to the hyperfine (HF) splitting Δ M HF ( 1 P ) = ( 0.6 ± 0.4 ± 1.0 ) MeV / c 2 . Using the transition h b ( 1 P ) → γ η b ( 1 S ) , we measure the η b ( 1 S ) mass M η b ( 1 S ) = ( 9400.7 ± 1.7 ± 1.6 ) MeV / c 2 , corresponding to Δ M HF ( 1 S ) = ( 59.6 ± 1.7 ± 1.6 ) MeV / c 2 , the η b ( 1 S ) width Γ η b ( 1 S ) = ( 8 - 5 + 6 ± 5 ) MeV / c 2 and the branching fraction B [ h b ( 1 P ) → γ η b ( 1 S ) ] = ( 56 ± 8 ± 4 ) % .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Inelastic Proton-Proton Cross Section at s = 13 TeV with the ATLAS Detector at the LHC

This Letter presents a measurement of the inelastic proton-proton cross section using 60 μ b -1 of p p collisions at a center-of-mass energy √ s of 13 TeV with the ATLAS detector at the LHC. Inelastic interactions are selected using rings of plastic scintillators in the forward region ( 2.07 < | η | < 3.86 ) of the detector. A cross section of 68.1 ± 1.4 mb is measured in the fiducial region ξ = M $2\atop{X}$ / s > 10 - 6 , where M X is the larger invariant mass of the two hadronic systems separated by the largest rapidity gap in the event. In this ξ range the scintillators are highly efficient. For diffractive events this corresponds to cases where at least one proton dissociates to a system with M X > 13 GeV . The measured cross section is compared with a range of theoretical predictions. When extrapolated to the full phase space, a cross section of 78.1 ± 2.9 mb is measured, consistent with the inelastic cross section increasing with center-of-mass energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the τ Lepton Polarization and R ( D * ) in the Decay B ¯ → D * τ - ν ¯ τ

Here, we discuss the first measurement of the τ lepton polarization P τ ( D * ) in the decay B ¯ → D * τ - ν ¯ τ as well as a new measurement of the ratio of the branching fractions R ( D * ) = B ( B ¯ → D * τ - ν ¯ τ ) / B ( B ¯ → D * ℓ - ν ¯ ℓ ) , where ℓ - denotes an electron or a muon, and the τ is reconstructed in the modes τ - → π - ν τ and τ - → ρ - ν τ . We use the full data sample of 772 × 1 0 6 B B ¯ pairs recorded with the Belle detector at the KEKB electron-positron collider. Our findings, P τ ( D * ) = - 0.38 ± 0.51 ( stat ) - 0.16 + 0.21 ( syst ) and R ( D * ) = 0.270 ± 0.035 ( stat ) - 0.025 + 0.028 ( syst ) , are consistent with the theoretical predictions of the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Assessing Gaussian Assumption of PMU Measurement Error Using Field Data

Gaussian PMU measurement noise has been assumed for many power system applications, such as state estimation, oscillatory modes monitoring, voltage stability analysis, to cite a few. This letter proposes a simple yet effective approach to validate this assumption by using the stability property of a probability distribution and the concept of redundant measurement. Extensive results using field PMU data from WECC system reveal that the Gaussian assumption is questionable.

Wang, Shaobu (ORCID:0000000236073573)↗

Photonic Doppler velocimetry probe used to measure grain boundaries of dynamic shocked materials

Material scientists have developed computational modeling to predict the dynamic response of materials undergoing stress, but there is still a need to make precision measurements of surfaces undergoing shock compression. Miniature photonic Doppler velocimetry (PDV) probes have been developed to measure the velocity distribution from a moving surface traveling tens of kilometers per second. These probes use hundreds of optical fibers imaged by optical relays onto different regions of this moving surface. While previous work examined large surface areas, we have now developed a PDV microscope that can interrogate 37 different spots within a field of view of <1 mm, with a standoff distance of 17 mm, to analyze the motion differences across grain boundaries of the material undergoing dynamic stress. Each PDV fiber interrogates a 10 μm spot size on the moving surface. A separate imaging system using a coherent bundle records the location of the PDV spots relative to the grain boundaries prior to the dynamic event. Designing the mounting structures for the lenses, fibers, and coherent bundle was a challenge. To minimize back reflections, the fibers are index matched onto the first relay lens, which is made of fused silica. The PDV fibers are aligned normal to the moving surface. The imaging probe views the surface at an 18° angle. The coherent bundle is tilted 11° to its optical relay. All components are assembled into a single probe head assembly. The coherent bundle is removed from the probe head to be used for the next dynamic event. Alignment issues will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗