Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC BEARINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Sound velocities of compressed Fe{sup 3}c from simultaneous synchrotron x-ray diffraction and nuclear resonant scattering measurements.

The applications of nuclear resonant scattering in laser-heated diamond anvil cells have provided an important probe for the magnetic and vibrational properties of {sup 57}Fe-bearing materials under high pressure and high temperature. Synchrotron X-ray diffraction is one of the most powerful tools for studying phase stability and equation of state over a wide range of pressure and temperature conditions. Recently an experimental capability has been developed for simultaneous nuclear resonant scattering and X-ray diffraction measurements using synchrotron radiation. Here the application of this method to determine the sound velocities of compressed Fe{sub 3}C is shown. The X-ray diffraction measurements allow detection of microscale impurities, phase transitions and chemical reactions upon compression or heating. They also provide information on sample pressure, grain size distribution and unit cell volume. By combining the Debye velocity extracted from the nuclear resonant inelastic X-ray scattering measurements and the structure, density and elasticity data from the X-ray diffraction measurements simultaneously obtained, more accurate sound velocity data can be derived. Our results on few-crystal and powder samples indicate strong anisotropy in the sound velocities of Fe{sub 3}C under ambient conditions.

43 PARTICLE ACCELERATORS↗

Crustal Magnetic Fields

Cosmos 49, Polar Orbit Geophysical Observatory (POGO) (Orbiting Geophysical Observatory (OGO-2, 4 and 6)) and Magsat have been the only low-earth orbiting satellites to measure the crustal magnetic field on a global scale. These missions revealed the presence of long- wavelength (> 500 km) crustal anomalies predominantly located over continents. Ground based methods were, for the most part, unable to record these very large-scale features; no doubt due to the problems of assembling continental scale maps from numerous smaller surveys acquired over many years. Questions arose as to the source and nature of these long-wave length anomalies. As a result there was a great stimulant given to the study of the magnetic properties of the lower crust and upper mantle. Some indication as to the nature of these deep sources has been provided by the recent results from the deep crustal drilling programs. In addition, the mechanism of magnetization, induced or remanent, was largely unknown. For computational ease these anomalies were considered to result solely from induced magnetization. However, recent results from Mars Orbiter Laser Altimeter (MOLA), a magnetometer-bearing mission to Mars, have revealed crustal anomalies with dimensions similar to the largest anomalies on Earth. These Martian features could only have been produced by remanent magnetization, since Mars lacks an inducing field. The origin of long-wavelength crustal anomalies, however, has not been completely determined. Several large crustal magnetic anomalies (e.g., Bangui, Kursk, Kiruna and Central Europe) will be discussed and the role of future satellite magnetometer missions (Orsted, SUNSAT and Champ) in their interpretation evaluated.

Taylor, Patrick T.↗

Multistage Magnetic Separator of Cells and Proteins

The multistage electromagnetic separator for purifying cells and magnetic particles (MAGSEP) is a laboratory apparatus for separating and/or purifying particles (especially biological cells) on the basis of their magnetic susceptibility and magnetophoretic mobility. Whereas a typical prior apparatus based on similar principles offers only a single stage of separation, the MAGSEP, as its full name indicates, offers multiple stages of separation; this makes it possible to refine a sample population of particles to a higher level of purity or to categorize multiple portions of the sample on the basis of magnetic susceptibility and/or magnetophoretic mobility. The MAGSEP includes a processing unit and an electronic unit coupled to a personal computer. The processing unit includes upper and lower plates, a plate-rotation system, an electromagnet, an electromagnet-translation system, and a capture-magnet assembly. The plates are bolted together through a roller bearing that allows the plates to rotate with respect to each other. An interface between the plates acts as a seal for separating fluids. A lower cuvette can be aligned with as many as 15 upper cuvette stations for fraction collection during processing. A two-phase stepping motor drives the rotation system, causing the upper plate to rotate for the collection of each fraction of the sample material. The electromagnet generates a magnetic field across the lower cuvette, while the translation system translates the electromagnet upward along the lower cuvette. The current supplied to the electromagnet, and thus the magnetic flux density at the pole face of the electromagnet, can be set at a programmed value between 0 and 1,400 gauss (0.14 T). The rate of translation can be programmed between 5 and 2,000 m/s so as to align all sample particles in the same position in the cuvette. The capture magnet can be a permanent magnet. It is mounted on an arm connected to a stepping motor. The stepping motor rotates the arm to position the capture magnet above the upper cuvette into which a fraction of the sample is collected. The electronic unit includes a power switch, power-supply circuitry that accepts 110-Vac input power, an RS-232 interface, and status lights. The personal computer runs the MAGSEP software and controls the operation of the MAGSEP through the RS-232 interface. The status of the power, the translating electromagnet, the capture magnet, and the rotation of the upper plate are indicated in a graphical user interface on the computer screen.

Barton, Ken↗

A lunar metal core

Recent work generally supports the hypothesis of a centrally condensed lunar core. Data regarding the axial moment on the basis of laser tracking and satellite orbit analyses place an upper limit of about 500 km on an Fe core, or 700 km upon an Fe/FeS core, if differentiation in the lithosphere is ignored. Whether a metallized core exists in the moon has a profound bearing upon the question of the origin of the magnetic fields responsible for the present day magnetization on the lunar surface. Recent efforts to examine in detail signals arising from lunar induction at very low frequency are discussed. The discussion represents an extension of a study reported by Wiskerchen et al. (1976). The present data base consists of all Apollo 12 data which fulfill the requirement that the surface magnetometer be on the sunward side of the moon and at least 10 deg from the lunar optical terminator. It is found that only marginal evidence exists for a metallized core at a radius of 400 km in the moon.

Wiskerchen, M. J.↗

High-stability Shuttle pointing system

It was recognized that precision pointing provided by the Orbiter's attitude control system would not be good enough for Shuttle payload scientific experiments or certain Defense department payloads. The Annular Suspension Pointing System (ASPS) is being developed to satisfy these more exacting pointing requirements. The ASPS is a modular pointing system which consists of two principal parts, including an ASPS Gimbal System (AGS) which provides three conventional ball-bearing gimbals and an ASPS Vernier System (AVS) which magnetically isolates the payload. AGS performance requirements are discussed and an AGS system description is given. The overall AGS system consists of the mechanical hardware, sensors, electronics, and software. Attention is also given to system simulation and performance prediction, and support facilities.

Van Riper, R.↗

Fiber-Optic Lateral-Displacement Sensor

Proposed fiber-optic sensor monitors axial position of shaft or bearing in turbomachine. Device senses position of non-magnetic as well as magnetic material and calibrates before assembly in machine. More compact. Concept extends to measure rotational speed of shaft.

Roschak, Edmund J.↗

Arcsecond grating drive mechanism for operation at 4 K

A grating drive mechanism that achieves arcsecond positional control at both room temperature and 4 K is described. The mechanism accommodates eight equally spaced facets on a 360-deg drum, with each facet having arcsecond control over an angular range of +/-3 deg. The cryogenic portion consists of dry lubricated angular contact bearings, a dc brushless torque motor, and a compact magnetic position sensor capable of less than 1 arcsec rms resolution. Test results demonstrate angular repeatability of less than 2 arcsec rms at 4 K and static power dissipation to the helium bath of less than 100 microW.

Downey, C. H.↗

Recovering rare earth metals from magnet scrap

A method is provided for treating a rare earth metal-bearing scrap material by melting an extractant selected from the group consisting of bismuth (Bi) and lead (Pb) and contacting the melted extractant and the scrap material at a temperature and time to recover at least one of the light rare earth metal content and the heavy rare earth metal content as a metallic extractant alloy, which can be subjected to vacuum distillation or sublimation to recover the rare earth metal(s). The method can be practiced to recover the light rare earth metal content and the heavy rare earth metal content concurrently in a one-step process or separately and sequentially in a two-step process.

Ott, Ryan T.↗

Nickel-Titanium Alloys: Corrosion "Proof" Alloys for Space Bearing, Components and Mechanism Applications

An intermetallic nickel-titanium alloy, 60NiTi (60wt%Ni, 40wt%Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high titanium content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of titanium and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of titanium alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is studied.

DellaCorte, Christopher↗

Nickel-Titanium Alloys: Corrosion "Proof" Alloys for Space Bearing, Components and Mechanism Applications

An intermetallic nickel-titanium alloy, 60NiTi (60 wt% Ni, 40 wt% Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high Ti content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of Ti and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of Ti alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is presented.

DellaCorte, Christopher↗

Combining paleointensity methods - A dual-valued determination on lunar sample 10017,135

A single-heating procedure for the determination of two partially independent values of paleofield intensity for one sample is presented. The procedure combines data for Shaw-type and 'ARM-method' determinations furnishing the ratio thermoremanent magnetization (TRM) to ARM acquisition efficiency corrected for physicochemical alteration to the magnetic carriers. Applicability of the Shaw-method to Fe-bearing samples is demonstrated by simulated paleointensity determinations on synthetic samples containing multidomain grains. The combined Shaw-ARM procedure was applied to a linear basalt sample, but the Thellier-Thellier method could not provide a meaningful determination of the neighboring chip. These conflicting findings may be explained by multiple step-wise heatings causing more damage to carriers than a single heating procedure, and by the natural remanent magnetization in this lunar basalt not being a simple TRM.

Hoffman, K. A.↗

Current Status of Hybrid Bearing Damage Detection

Advances in material development and processing have led to the introduction of ceramic hybrid bearings for many applications. The introduction of silicon nitride hybrid bearings into the high pressure oxidizer turbopump, on the space shuttle main engine, led NASA to solve a highly persistent and troublesome bearing problem. Hybrid bearings consist of ceramic balls and steel races. The majority of hybrid bearings utilize Si3N4 balls. The aerospace industry is currently studying the use of hybrid bearings and naturally the failure modes of these bearings become an issue in light of the limited data available. In today s turbine engines and helicopter transmissions, the health of the bearings is detected by the properties of the debris found in the lubrication line when damage begins to occur. Current oil debris sensor technology relies on the magnetic properties of the debris to detect damage. Since the ceramic rolling elements of hybrid bearings have no metallic properties, a new sensing system must be developed to indicate the system health if ceramic components are to be safely implemented in aerospace applications. The ceramic oil debris sensor must be capable of detecting ceramic and metallic component damage with sufficient reliability and forewarning to prevent a catastrophic failure. The objective of this research is to provide a background summary on what is currently known about hybrid bearing failure modes and to report preliminary results on the detection of silicon nitride debris, in oil, using a commercial particle counter.

Dempsey, Paula J.↗

Interpretation of CHAMP Magnetic Anomaly Data over the Pannonian Basin Region Using Lower Altitude Horizontal Gradient Data

The ESA SWARM mission will have three earth orbiting magnetometer bearing satellites one in a high orbit and two side-by-side in lower orbits. These latter satellites will record a horizontal magnetic gradient. In order to determine how we can use these gradient measurements for interpretation of large geologic units we used ten years of CHAMP data to compute a horizontal gradient map over a section of southeastern Europe with our goal to interpret these data over the Pannonian Basin of Hungary.

CHAMP↗

The initiation of coronal mass ejections by newly emerging magnetic flux

We present observational evidence that eruptions of quiescent filaments and associated coronal mass ejections (CMEs) occur as a consequence of the destabilization of large-scale coronal arcades due to interactions between these structures and new and growing active regions. Both statistical and case studies have been carried out. In a case study of a 'bulge' observed by the High-Altitude Observatory Solar Maximum Mission coronagraph, the high-resolution magnetograms from the Big Bear Solar Observatory show newly emerging and rapidly changing flux in the magnetic fields that apparently underlie the bugle. For other case studies and in the statistical work the eruption of major quiescent filaments was taken as a proxy for CME eruption. We have found that two thirds of the quiescent-filament-associated CMEs occurred after substantial amounts of new magnetic flux emerged in the vicinity of the filament. In addition, in a study of all major quiescent filaments and active regions appearing in a 2-month period we found that 17 of the 22 filaments that were associated with new active regions erupted and 26 of the 31 filaments that were not associated with new flux did not erupt. In all cases in which the new flux was oriented favorably for reconnection with the preexisting large-scale coronal arcades; the filament was observed to erupt. The appearance of the new flux in the form of new active regions begins a few days before the eruption and typically is still occurring at the time of the eruption. A CME initiation scenario taking account of these observational results is proposed.

Feynman, J.↗

Hybrid lubrication system and bearing Patent

Development of hybrid bearing lubrication system with combination of standard type lubrication and magnetic flux field for earth atmosphere and space environment operation

Sauer, L. S.↗