Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

I.1 Heavy-Duty Diesel Combustion (Sandia National Laboratories)

Regulatory drivers and market demands for lower pollutant emissions, lower carbon dioxide emissions, and lower fuel consumption motivate the development of cleaner and more fuel-efficient engine operating strategies. Most current production heavy-duty diesel engines use a combination of both in-cylinder and exhaust emissions-control strategies to achieve these goals. The emissions and efficiency performance of in-cylinder strategies depend strongly on flow and mixing processes that can be influenced by using multiple fuel injections. Past work performed under this project showed that adding a second injection can reduce soot to levels below what would have been produced by an unchanged first injection, thereby increasing load while decreasing soot and potentially reducing brake specific fuel consumption. Information characterizing the important in-cylinder processes with multiple injections has been gleaned from ensemble-averaged planar laser-induced incandescence (PLII) imaging visualizing the soot cloud and planar induced fluorescence (PLIF) of OH characterizing the soot oxidation regions. PLII showed a consistent disruption of the first injection soot cloud by the second injection. In conjunction with OH-PLIF, differences in soot oxidation patterns for multiple injections compared to single injections were observed. This understanding was further enhanced in FY20, when high-speed imaging resolving the above-mentioned effects in a single cycle were combined with direct numerical simulations investigating the multiple-injection ignition process on the microscopic level of turbulence and chemistry interaction. In FY21, these findings in conjunction with findings from other researchers published in the scientific literature were composed into a preliminary multiple-injection conceptual model of fuel-mixing, injection and ignition processes. Remaining key research questions were also highlighted. In addition, wall heat flux was investigated experimentally and with numerical simulations to understand the potential of multiple injections to reduce the engine heat losses and further enhance the efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

Testing of Helium Cooled Metal Molybdenum Disk Target System

NorthStar Medical Radioisotopes LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through a photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess as high a tensile strength as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and the high thermal stress from beam heating.

42 ENGINEERING↗

Congestion levels on existing infrastructure

Congestion occurs when available least-cost energy cannot be delivered to some loads because transmission facilities do not have sufficient capacity to deliver the energy. When a transmission constraint is binding (i.e., its limit is reached) it has an associated shadow price – the marginal value of relieving the constraint (i.e., of increasing the asset’s flow limit). This report contains one page dedicated to each ISO and RTO in the U.S. documenting empirical outcomes related to binding constraints during 2022 through 2024 for both the day-ahead and real-time markets. For each system operator and market timeline, the report contains two maps of infrastructure elements that are color-coded based on congestion characteristics. The first map provides information on how often each element has a binding constraint, that is, the frequency of congestion on the element. The second map reflects the intensity of congestion, measured as the sum of shadow prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence N - Raw Data

Sequence N: Sin AOA, Rotating (P) This sequence was designed to quantify the blade 3-D unsteady aerodynamic response in the presence of rotational influences by varying blade pitch angle. Test sequence N used an upwind, rigid turbine with a 0° cone angle. The wind speed was 15 m/s, and the yaw angle was 0° throughout the sequence. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. Sinusoidal angle-of-attack histories were designed to emulate 2-D S809 dynamic data obtained at the Ohio State University (OSU) wind tunnel (Reuss Ramsey et al. 1995) and the 1P yawed flow angle-of-attack variations the turbine could be expected to encounter in routine operation. The reduced frequency (K), mean angle of attack (αm), and oscillation amplitude (αω) were computed for each of the five primary span locations. The file lengths varied according to the time required to complete 40 oscillations at the specified frequency. The file name convention used the sequence designation N, followed by two digits for the span location (30, 47, 63, 80, or 95), followed by two digits representing the condition specified in the test matrix, followed by the repetition digit. Due to time constraints, most of the test conditions corresponding to the 63% span location were eliminated. Test points with a static pitch angle of 3° were collected throughout the sequence to ascertain instrumentation fidelity.

17 WIND ENERGY↗

Tidal Turbine Benchmarking Project: Stage I - Steady Flow Blind Predictions: Preprint

This paper presents the first blind prediction stage of the Tidal Turbine Benchmarking Project being conducted and funded by the UK's EPSRC and Supergen ORE Hub. In this first stage, only steady flow conditions, at low and elevated turbulence (3.1%) levels, were considered. Prior to the blind prediction stage, a large laboratory scale experiment was conducted in which a highly instrumented 1.6m diameter tidal rotor was towed through a large towing tank in well-defined flow conditions with and without an upstream turbulence grid. Details of the test campaign and rotor design were released as part of this community blind prediction exercise. Participants were invited to use a range of engineering modelling approaches to simulate the performance and loads of the turbine. 26 submissions were received from 12 groups from across academia and industry using solution techniques ranging from blade resolved computational fluid dynamics through actuator line, boundary integral element methods, vortex methods to engineering Blade Element Momentum methods. The comparisons between experiments and blind predictions were extremely positive helping to provide validation and uncertainty estimates for the models, but also validating the experimental tests themselves. The exercise demonstrated that the experimental turbine data provides a robust data set against which researchers and design engineers can test their models and implementations to ensure robustness in their processes, helping to reduce uncertainty and provide increased confidence in engineering processes. Furthermore, the data set provides the basis by which modellers can evaluate and refine approaches.

benchmarking↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

A Two-Stage Decomposition Approach for AC Optimal Power Flow

The alternating current optimal power flow (AC-OPF) problem is critical to power system operations and planning, but it is generally hard to solve due to its nonconvex and large-scale nature. Furthermore, this paper proposes a scalable decomposition approach in which the power network is decomposed into a master network and a number of subnetworks, where each network has its own AC-OPF subproblem. This formulates a two-stage optimization problem and requires only a small amount of communication between the master and subnetworks. The key contribution is a smoothing technique that renders the response of a subnetwork differentiable with respect to the input from the master problem, utilizing properties of the barrier problem formulation that naturally arises when subproblems are solved by a primal-dual interior-point algorithm. Consequently, existing efficient nonlinear programming solvers can be used for both the master problem and the subproblems. The advantage of this framework is that speedup can be obtained by processing the subnetworks in parallel, and it has convergence guarantees under reasonable assumptions. The formulation is readily extended to instances with stochastic subnetwork loads. Numerical results show favorable performance and illustrate the scalability of the algorithm which is able to solve instances with more than 11 million buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Optimal Solutions for Extremely Fast AC Optimal Power Flow

We develop, in this paper, a machine learning approach to optimize the real-time operation of electric power grids. In particular, we learn feasible solutions to the AC optimal power flow (OPF) problem with negligible optimality gaps. The AC OPF problem aims at identifying optimal operational conditions of the power grids that minimize power losses and/or generation costs. Due to the computational challenges with solving this nonconvex problem, many efforts have focused on linearizing or approximating the problem in order to solve the AC OPF on faster timescales. However, many of these approximations can be fairly poor representations of the actual system state and still require solving an optimization problem, which can be time consuming for large networks. In this work, we learn a mapping between the system loading and optimal generation values, enabling us to find near-optimal and feasible AC OPF solutions. This allows us to bypass solving the traditionally nonconvex AC OPF problem, resulting in a significant decrease in computational burden for grid operators.

machine learning↗

Learning Optimal Solutions for Extremely Fast AC Optimal Power Flow: Preprint

We develop, in this paper, a machine learning approach to optimize the real-time operation of electric power grids. In particular, we learn feasible solutions to the AC optimal power flow (OPF) problem with negligible optimality gaps. The AC OPF problem aims at identifying optimal operational conditions of the power grids that minimize power losses and/or generation costs. Due to the computational challenges with solving this nonconvex problem, many efforts have focused on linearizing or approximating the problem in order to solve the AC OPF on faster timescales. However, many of these approximations can be fairly poor representations of the actual system state and still require solving an optimization problem, which can be time consuming for large networks. In this work, we learn a mapping between the system loading and optimal generation values, enabling us to find near-optimal and feasible AC OPF solutions. This allows us to bypass solving the traditionally nonconvex AC OPF problem, resulting in a significant decrease in computational burden for grid operators.

machine learning↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synergistic Solvent-Surface Interactions Enable Alkyne Semihydrogenation at Palladium

Enabling higher yield and better selectivity for fine-chemical synthesis through heterogeneous catalysis is intricately linked to the interplay of active sites, reaction conditions, and mass transfer influence provided by the catalyst. Alkyne semihydrogenation is ubiquitous in the production of bulk chemicals in the pharmaceutical, polymer, or fine-chemical industries, but product selectivity remains a major challenge. Here, in this study, we demonstrate that the design of catalysts encompassing nickel (Ni) foams as contiguous monolith supports, decorated with ultralow loading of Pd/PdO x nanoparticles on a carbonized polydopamine interface and tuned with a thin layer of Al 2 O 3 , in conjunction with an optimized reaction environment leads to highly selective alkyne semihydrogenation. The reactions demonstrate good functional group tolerance and applicability to flow reactor systems. Combined computational and experimental studies are presented to describe the synergistic effect between the solvent-surface interaction and the degree of Pd surface reduction that are necessary to promote this selectivity. The system highlights the opportunity for catalyst-solvent codesign as a benign alternative to more complex reactants featuring extrinsic poisons or less-favored dopants.

atomic layer deposition↗

Design and Engineering of LUPIN: A Test-Bed Radio-Frequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is a radio-frequency (RF) inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D neutral beam injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa ⋅ L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Finally, results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

ORPC RivGen 2.0 at Igiugig, AK Operational Data 2019 and 2020

Information enclosed includes operational data from the ORPC RivGen 2.0 deployed at Igiugig, AK in 2019 and 2020. Flow velocities and device performance metrics are recorded along with a report detailing flow speed characterization where Igiugig river flow data is aggregated into a single flow velocity.

16 TIDAL AND WAVE POWER↗

MITR DDE End Fitting Structural Rigidity Analysis

As a part of the design of the MITR Design Demonstration Element (DDE), a new design for the end fittings must be considered to meet specific experiment needs, e.g., compatibility with the geometrical restrictions of the DDE testing location (BR2 test reactor located in Mol, Belgium), and to allow for proper inspection of these test elements during the experiments. The design of the MITR DDE end fittings is substantially different from the design of the end fittings of the MITR LEU fuel elements, with the DDE end fittings considerably smaller in overall size and weight. Consequently, the stiffness of the end fittings as well as of the entire fuel element is affected. The end fittings in the MITR LEU fuel element are designed primarily for proper handling and flow distribution. The stiffness of the end fittings also constitutes a fraction of the total stiffness of the entire fuel element. It is debatable to what extent the end fittings provide the structural rigidity necessary for the fuel element to properly respond to potential loadings. It is presumed that the bulk of the overall stiffness of the element is derived from swaging multiple fuel plates into the side plates. However, the contribution of stiffness from various components of the MITR LEU fuel element and MITR DDE has not been determined so far. The primary objective of the work presented in this report was to assess the extent to which the stiffness of the end fitting in the MITR DDE contributes to the stiffness of the entire fuel element, and how it compares to the equivalent stiffness of the end fitting in the MITR LEU fuel element. Several simplified load cases were analyzed for that purpose using the geometries of the MITR LEU fuel element, MITR DDE, as well as that of the MITR DDE without the top end fitting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and Engineering of LUPIN: A Test-Bed Radiofrequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D Neutral Beam Injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10 s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa·L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Multilevel Graph Partitioning for Three-Dimensional Discrete Fracture Network Flow Simulations

We present a topology-based method for mesh-partitioning in three-dimensional discrete fracture network (DFN) simulations that takes advantage of the intrinsic multi-level nature of a DFN. DFN models are used to simulate flow and transport through low-permeability fractured media in the subsurface by explicitly representing fractures as discrete entities. The governing equations for flow and transport are numerically integrated on computational meshes generated on the interconnected fracture networks. Modern high-fidelity DFN simulations require high-performance computing on multiple processors where performance and scalability depends partially on obtaining a high-quality partition of the mesh to balance work-loads and minimize communication across all processors. The discrete structure of a DFN naturally lends itself to various graph representations, which can be thought of as coarse-scale representations of the computational mesh. Using this concept, we develop two applications of the multilevel graph partitioning algorithm to partition the mesh of a DFN. In the first, we project a partition of the graph based on the DFN topology onto the mesh of the DFN and in the second, this DFN-based projection is used as the initial condition for further partitioning refinement of the mesh. We compare the performance of these methods with standard multi-level graph partitioning using graph-based metrics (cut, imbalance, partitioning time), computational-based metrics (FLOPS, iterations, solver time), and total run time. The DFN-based and the mesh-based partitioning methods are comparable in terms of the graph-based metrics, but the time required to obtain the partition is several orders of magnitude faster using the DFN-based partitions. The computation-based metrics show comparable performance between both methods so, in combination, the DFN-based partitions are several orders of magnitude faster than the mesh-based partition. Furthermore, the method which uses the DFN-partition solution as the initial condition of the mesh partition provided cut and imbalance values that were close to the mesh-based partition but in a fraction of the time. In turn, this hybrid method outperformed both of the other methods in terms of the total run time.

58 GEOSCIENCES↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗