Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The FUNPET—a New Hybrid Ion Funnel-Ion Carpet Atmospheric Pressure Interface for the Simultaneous Transmission of a Broad Mass Range

An atmospheric pressure interface transports ions from ambient pressure to the low-pressure environment of a mass spectrometer. A capillary coupled to an ion funnel is widely used. However, conventional ion funnels do little to negate the large amount of energy picked up by high-mass ions from the gas flow through the capillary. There has been little work done on the effects of gas flow on ion transmission, and the previous studies have all been limited to low-mass, low-charge ions. In this work, we account for the effects of gas flow, diffusion, and electric fields (static and oscillating) on ion trajectories and use simulations to design a new hybrid ion funnel-ion carpet (FUNPET) interface that transmits a broad mass range with a single set of instrument conditions. The design incorporates a virtual jet disruptor where pressure buildup and counter flow dissipate the supersonic jet that results from gas flow into the interface. This, and the small exit aperture that can be used with the FUNPET, reduces the gas flow into the next stage of differential pumping. The virtual jet disruptor thermalizes ions with a broad range of masses (1 kDa to 1 GDa), and once thermalized, they are transmitted into next region of the mass spectrometer with low excess kinetic energy. The FUNPET interface is easy to fabricate from flexible printed circuit board and a support frame made by 3D printing. The performance of the interface was evaluated using charge detection mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stopping of relativistic heavy ions in various media

The residual ranges of (900 + or - 3)-MeV/amu gold nuclei accelerated at the Lawrence Berkeley Laboratory Bevalac have been measured in several different media. The energy of the beam of nuclei was measured directly using a new time-of-flight system. The ranges were measured by absorption in linear wedges of polyethylene, carbon, aluminum, copper, tin, and lead and in circular wedges of polystyrene, aluminum, and gold, and by total absorption in nuclear emulsion. The measured ranges were significantly different from those calculated from the best available theoretical estimates of the energy loss of highly charged nuclei. It is concluded that at present energy losses and residual ranges of relativistic heavy ions in an arbitrary medium cannot be predicted with better than an approximately 2 percent accuracy.

Waddington, C. J.↗

Evolution of ion distributions across the nearly perpendicular bow shock - Specularly and non-specularly reflected-gyrating ions

Data from ISEE 1 and 2 spacecraft were used to study the evolution of the ion distributions in the perpendicular terrestrial bow shock. The plasma data were taken during passage of the spacecraft downstream of and through the shock. Solar wind ions had velocities ranging from Mach 2-12.4, and reflected ions featured a relative density of 1-3 percent of the solar wind density at Mach 2 to 15-25 percent at Mach 8-12. Computer simulations have indicated that the ions provide essential dissipation at the shock and gyrate about the magnetic field lines in the plasma rest frame at a speed twice that of the normal incident solar wind flow. The ion density decreases by up to two orders of magnitude at the forward end of the foot of the shock profile, suggesting that the ions are reflected by the shock specularly, and may enhance downstream ion thermalization.

Sckopke, N.↗

Nanoscale Mechanical Behavior of Nuclear Materials

One of the primary performance objectives targeted for improved performance of nuclear fuels is fracture toughness. New materials or composite fuel architectures that offer greater resistance to cracking under the extreme environments encountered during nuclear reactor service would provide significant improvements to steady state (e.g. heat transfer, fuel redistribution) and transient (e.g. radionuclide release at elevated temperatures) conditions. Options currently under investigation include 'nontraditional' nuclear fuels designated around high uranium density. These include uranium silicides, uranium borides, and composite fuel materials constructed of these and uranium nitride or uranium dioxide. The increase uranium density compared with uranium dioxide (UO{sub 2}) has made them interesting to a new generation of nuclear fuels research driven by the renewed push for accident-tolerant light water reactor (LWR) fuels. Measurement of the thermophysical and thermodynamic properties of these constituent materials has progressed in recent years, but evaluation of mechanical properties at relevant temperatures is necessary to support further evaluations. While thermophysical properties such as thermal conductivity, heat capacity, and thermal expansion are generally the primary properties of interest, mechanical properties will play an important role in governing the deformation and fracture of the fuel during both normal operation and potential transients. It is therefore necessary to develop techniques capable of measuring these properties to predict the response of a candidate fuel form to anticipated thermal gradients. Nanoindentation techniques provide a demonstrated alternative to traditional mechanical test methods. Much work has also been carried out over the past few years to obtain stress-strain curves using a spherical nanoindentation approach. The techniques are expected to be useful for measurement of the mechanical properties of local structure of various materials. Nanomechanical test techniques have particular value in the area of nuclear materials, where numerous factors motivate limiting the sample volume to the extent possible. However, few attempts at application of nanoindentation to evaluate the mechanical properties of the nuclear fuels and cladding materials are reported in the literature. The effect of a limited set of variables (e.g. porosity, temperature dependence) on the mechanical properties of UO{sub 2} has been explored using early nanomechanical testing techniques. However, nanomechanical evaluation has not been extended to other nuclear fuels. In this work, we demonstrate the effectiveness of using instrumented spherical nanoindentation test techniques to capture the mechanical response of regions within individual grains in ion-irradiated W and Zr over a range of ion-irradiation conditions. As well as the nanomechanical response of U-Si and UO{sub 2} fuel materials Nanoindentation results obtained at room temperature will be used to express nano- and bulk- mechanical properties as a function of material stoichiometry. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interpretation of the ion mass spectra in the mass per charge range 25-35 amu/e obtained in the inner coma of Halley's comet by the HIS-sensor of the Giotto IMS experiment

The IMS-HIS double-focusing mass spectrometer that flew on the Giotto spacecraft covered the mass per charge range from 12 to 56 (amu/e). By comparing flight data, calibration data and results of model calculations of the ion population in the inner coma, the absolute mass scale is established, and ions in the mass range 25 to 35 are identified. Ions resulting from protonation of molecules with high proton affinity are relatively abundant, enabling us to estimate relative source strengths for H2CO, CH3OH, HCN, and H2S, providing for the first time a positive in situ measurement of methanol. Also, upper limits for NO and some hydrocarbons are derived.

Geiss, J.↗

Swelling resistance of advanced austenitic alloy A709 and its comparison with 316 stainless steel at high damage levels

Alloy A709 is an austenitic alloy developed for power boiler applications in thermal power plants and is being considered as a candidate structural material for Generation IV reactors and fusion reactors, based especially on its increased creep strength over Type 316 stainless steel. However, improved thermal creep properties would not necessarily imply improved radiation resistance, especially with respect to void swelling. Since there are currently no neutron irradiation data on A709 to high fluences, A709 and cold-worked 316 were irradiated in the present study under identical conditions to doses between 100 and 400 peak dpa using irradiation by 3.5 MeV Fe +2 ions. The swelling behavior of 316 is well-known for both neutron and ion irradiation, thus the relative swelling behavior of A709 and 316 under ion irradiation might provide an indication of the swelling behavior of A709 in neutron irradiation environment. Swelling of A709 under ion irradiation was observed over the range of 500-600 ⁰C, peaking at 575 ⁰C. Both A709 and 316 eventually swelled at a rate of ~1 %/dpa under ion irradiation at 575 ⁰C, consistent with the swelling of 316 observed during neutron irradiation. But A709 had a significantly longer transient regime than 316 at any given dpa rate, demonstrating enhanced swelling resistance of A709 over 316 under self-ion irradiation. The swelling levels reached at 400 peak dpa were 55% and 90% for A709 and 316, respectively. The assigned local dpa levels were adjusted both temporally and spatially at each dose for swelling-induced increases in the ion range and concomitant decreases in density. The duration of the transient regimes in each alloy was also observed to increase as the local dpa rate increased, an observation also consistent with neutron irradiation behavior of 316 stainless steel.

36 MATERIALS SCIENCE↗

WE-E-BRF-01: The ESTRO-AAPM Joint Symposium On Imaging for Proton Treatment Planning and Guidance

In this first inaugural joint ESTRO-AAPM session we will attempt to provide some answers to the problems encountered in the clinical application of particle therapy. Indeed the main advantage is that the physical properties of ion beams offer high ballistic accuracy for tightly conformal irradiation of the tumour volume, with excellent sparing of surrounding healthy tissue and critical organs, This also its Achilles' heel calling for an increasing role of imaging to ensure safe application of the intended dose to the targeted area during the entire course of fractionated therapy. We have three distinguished speakers addressing possible solutions. Katia Parodi (Ludwig Maximilians University, Munich, Germany) To date, Positron Emission Tomography (PET) is the only technique which has been already clinically investigated for in-vivo visualization of the beam range during or shortly after ion beam delivery. The method exploits the transient amount of β{sup 2}-activity induced in nuclear interactions between the primary beam and the irradiated tissue, depending on the ion beam species, the tissue elemental composition and physiological properties (in terms of biological clearance), as well as the time course of irradiation and imaging. This contribution will review initial results, ongoing methodological developments and remaining challenges related to the clinical usage of viable but often suboptimal instrumentation and workflows of PET-based treatment verification. Moreover, it will present and discuss promising new detector developments towards next-generation dedicated PET scanners relying on full-ring or dual-head designs for in-beam quasi real-time imaging. Denis Dauvergne (Institut de Physique Nucleaire de Lyon, Lyon, France) Prompt gamma radiation monitoring of hadron therapy presents the advantage of real time capability to measure the ion range. Both simulations and experiments show that millimetric verification of the range can be achieved at the pencil beam scale for active proton beam delivery in homogenous targets. The development of gamma cameras, that has been studied by several groups worldwide over the last years, now reaches - for some of them - the stage of being applicable in clinical conditions, with real size prototypes and count rate capability matching the therapeutic beam intensities. We will review the different concepts of gamma cameras, the advantages and limitations of this method, and the main challenges that should still be overcome before the widespread of prompt gamma quality assurance for proton and hadrontherapy. Jon Kruse (Mayo Clinic, Rochester, MN, USA) Treatment simulation images for proton therapy are used to determine proton stopping power and range in the patient. This talk will discuss the careful control of CT numbers and conversion of CT number to stopping power required in proton therapy. Imaging for treatment guidance of proton therapy also presents unique challenges which will be addressed. Among them are the enhanced relationship between internal anatomy changes and dosimetry, the need for imaging to support adaptive planning protocols, and high operational efficiency. Learning Objectives: To learn about the possibilities of using activation products to determine the range of particle beams in a patient treatment setting To be informed on an alternative methodology using prompt gamma detectors To understand the impact of the accuracy of the knowledge of the patient information with respect to the delivered treatment.

60 APPLIED LIFE SCIENCES↗

Influence of ion energy and ion species on ion channeling in LiNbO{sub 3}

Ion irradiation of LiNbO{sub 3} causes the formation of defects due to nuclear as well as electronic energy deposition {epsilon}{sub n} and {epsilon}{sub e}, respectively. However, the defect formation is influenced by the orientation of the crystal. If the irradiation is performed along a low index crystallographic direction (on-axis) the defect distributions are strongly affected by ion channeling because the ions are prevented from close collisions with the target atoms so that the penetration range of the impinging ions is increased. In order to investigate the effect of {epsilon}{sub n} and {epsilon}{sub e} on damage formation LiNbO{sub 3} crystals were irradiated on- and off-axes using Si{sup +} and Cu{sup +} ions with energies ranging from 550 keV to 2 MeV. We demonstrate for on-axis irradiation that at low ion energies where {epsilon}{sub n} dominates the formation of defects, the defect distribution is shifted to larger depths compared to off-axis irradiation. The investigation of the shift shows a square-root dependence on both ion energy and ion species. Furthermore, on-axis irradiation was done using high-ion energies where defects are formed in the near-surface region due to electronic energy loss. Compared to off-axis irradiation a thinner amorphous surface layer was formed as a result of the reduced electronic energy loss in the case of on-axis irradiation. For on-axis irradiation {epsilon}{sub e} could be estimated in two different ways considering the layer thickness and the penetration range of the incident ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

STORAGE RING CROSS-SECTION MEASUREMENTS FOR ELECTRON IMPACT SINGLE AND DOUBLE IONIZATION OF Fe{sup 9+} AND SINGLE IONIZATION OF Fe{sup 10+}

We have measured electron impact ionization from the ground state of Fe{sup 9+} and Fe{sup 10+} over the relative electron-ion collision energy ranges 200-1900 eV and 250-1800 eV, respectively. The ions were confined in an ion storage ring long enough for essentially all metastable levels to radiatively relax to the ground state. For single ionization, we find a number of discrepancies between the existing theoretical cross sections and our results. The calculations appear to neglect some excitation-autoionization (EA) channels, particularly from n = 3 to n' excitations, which are important near threshold, and those from n = 2 {yields} 3 excitations, which contribute at about 650 eV. Conversely, at higher energies the calculations appear to overestimate the importance of EA channels due to excitation into levels where n {>=} 4. The resulting experimental rate coefficients agree with the most recent theory for Fe{sup 9+} to within 16% and for Fe{sup 10+} to within 19% at temperatures where these ions are predicted to form in collisional ionization equilibrium. We have also measured double ionization of Fe{sup 9+} forming Fe{sup 11+} in the energy range 450-3000 eV and found that although there is an appreciable cross section for direct double ionization, the dominant mechanism appears to be through direct ionization of an inner shell electron producing an excited state that subsequently stabilizes through autoionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Beam Angular Divergence Effects in Ion Implantation

An important difference between monomer ion beams and heavy molecular beams is a significant reduction in beam angular divergence and increased on-wafer angular accuracy for molecular beams. This advantage in beam quality stems from a reduction in space-charge effects within the beam. Such improved angular accuracy has been shown to have a significant impact on the quality and yield of transistor devices [1,12]. In this study, B{sub 18}H{sub x}{sup +} beam current and angular divergence data collected on a hybrid scanned beam line that magnetically scans the beam across the wafer is presented. Angular divergence is kept below 0.5 deg from an effective boron energy of 200 eV to 3000 eV. Under these conditions, the beam current is shown analytically to be limited by space charge below about 1 keV, but by the matching of the beam emittance to the acceptance of the beam line above 1 keV. In addition, results of a beam transport model which includes variable space charge compensation are presented, in which a drift mode B{sub 18}H{sub x}{sup +} beam is compared to an otherwise identical boron beam after deceleration. Deceleration is shown to introduce significant space-charge blow up resulting in a large on-wafer angular divergence. The divergence effects introduced by wafer charging are also discussed.

36 MATERIALS SCIENCE↗

IMPROVING THE MODEL OF EMISSION FROM SPINNING DUST: EFFECTS OF GRAIN WOBBLING AND TRANSIENT SPIN-UP

Observations continue to support the interpretation of the anomalous microwave foreground as electric dipole radiation from spinning dust grains as proposed by Draine and Lazarian. In this paper, we present a refinement of the original model by improving the treatment of a number of physical effects. First, we consider a disk-like grain rotating with angular velocity at an arbitrary angle with respect to the grain symmetry axis (i.e., grain wobbling) and derive the rotational damping and excitation coefficients arising from infrared emission, plasma-grain interactions, and electric dipole emission. The angular velocity distribution and the electric dipole emission spectrum for disk-like grains is calculated using the Langevin equation, for cases both with and without fast internal relaxation. Our results show that for fast internal relaxation, the peak emissivity of spinning dust, compared to earlier studies, increases by a factor of {approx}2 for the warm neutral medium (WNM), the warm ionized medium (WIM), the cold neutral medium (CNM), and the photodissociation region, and by a factor {approx}4 for reflection nebulae. The frequency at the emission peak also increases by factors {approx}1.4 to {approx}2 for these media. Without internal relaxation, the increase of emissivity is comparable, but the emission spectrum is more extended to higher frequency. The increased emission results from the non-sphericity of grain shape and from the anisotropy in damping and excitation along directions parallel and perpendicular to the grain symmetry axis. Second, we provide a detailed numerical study including transient spin-up of grains by single-ion collisions. The range of grain size in which single-ion collisions are important is identified. The impulses broaden the emission spectrum and increase the peak emissivity for the CNM, WNM, and WIM, although the increases are not as large as those due to the grain wobbling. In addition, we present an improved treatment of rotational excitation and damping by infrared emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Field emission of cesium ions

Field emission of cesium ions from positive electrode formulated for electric field range that binds ions to electrode surface

Sama, N.↗

Heavy-ion physics with the ATLAS detector

The CERN LHC collider will operate with lead ions at {radical}s of 5.5 TeV/nucleon. The ATLAS detector, designed to study high-pT physics in the pp mode of the LHC, has the potential to study ultrarelativistic heavy-ion collisions in a full range of observables characterized extremely dense matter and the formation of a quark-gluon plasma. The ATLAS physics program includes global event measurements (particle multiplicities, transverse momentum), suppression of heavy-quarkonia production, jet quenching, and a study of ultraperipheral collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear physics program at HIRFL

With the commissioning of HIRFL-CSR, HIRFL can provide heavy ion beams with energy covering the range of several MeV/u to 1 GeV/u. In this talk, the experiments on nuclear physics at different energies to be carried out with different experimental setups at HIRFL will be introduced.

43 PARTICLE ACCELERATORS↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗